RG2CJSD
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Titanium Alloy Or Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | REFTitanium Alloy | Specification |
Femoral Reconstruction Intramedullary Nail match 4.5mm locking screw6.0mm locking screw Full-threaded | RG2CJSD09320L | Ф9×320 L | |
RG2CJSD09340L | Ф9×340 L | ||
RG2CJSD09360L | Ф9×360 L | ||
RG2CJSD09380L | Ф9×380 L | ||
RG2CJSD09400L | Ф9×400 L | ||
RG2CJSD09420L | Ф9×420 L | ||
RG2CJSD09320R | Ф9×320 R | ||
RG2CJSD09340R | Ф9×340 R | ||
RG2CJSD09360R | Ф9×360 R | ||
RG2CJSD09380R | Ф9×380 R | ||
RG2CJSD09400R | Ф9×400 R | ||
RG2CJSD09420R | Ф9×420 R | ||
RG2CJSD10320L | Ф10×320 L | ||
RG2CJSD10340L | Ф10×340 L | ||
RG2CJSD10360L | Ф10x360 L | ||
RG2CJSD10380L | Ф10×380 L | ||
RG2CJSD10400L | Ф10×400 L | ||
RG2CJSD10420L | Ф10×420 L | ||
RG2CJSD10320R | Ф10×320 R | ||
RG2CJSD10340R | Ф10×340 R | ||
RG2CJSD10360R | Ф10x360 R | ||
RG2CJSD10380R | Ф10×380 R | ||
RG2CJSD10400R | Ф10×400 R | ||
RG2CJSD10420R | Ф10×420 R | ||
RG2CJSD11320L | Ф11x320 L | ||
RG2CJSD11340L | Ф11x340 L | ||
RG2CJSD11360L | Ф11x360 L | ||
RG2CJSD11380L | Ф11x380 L | ||
RG2CJSD11400L | Ф11x400 L | ||
RG2CJSD11420L | Ф11x420 L | ||
RG2CJSD11320R | Ф11x320 R | ||
RG2CJSD11340R | Ф11x340 R | ||
RG2CJSD11360R | Ф11x360 R | ||
RG2CJSD11380R | Ф11x380 R | ||
RG2CJSD11400R | Ф11x400 R | ||
RG2CJSD11420R | Ф11x420 R |
Standard Locking IndicationsThe Antegrade Femoral Nail with standard locking is indicated for fractures in the femoral shaft. |
Recon Locking IndicationsThe Antegrade Femoral Nail with recon locking is indicated for fractures in the femoral shaft in case of combination with femoral neck fractures. Additionally, the Antegrade Femoral Nail is indicated for fractures in the subtrochanteric section. |
AFN Implants:Standard locking implantsProximal diameters:9-11mm 4.7 mm Locking Bolt Lengths 26-84mm (in 2 mm increments) Anatomical 6 MLangle 1500 mm bending radius Cannulated for reamed/undreamed insertion Lengths 320-420 mm (in 20mm increments) The Antegrade Femoral Nail(AFN) is available in titanium alloy A choice of static or dynamic interlocking. |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask XC Medico team for femoral reconstruction intramedullary nail product catalog.
2. Choose your interested femoral reconstruction intramedullary nail product.
3. Ask for a sample to test femoral reconstruction intramedullary nail quality.
4.Make an order of XC Medico's femoral reconstruction intramedullary nail.
5.Become a dealer of XC medico's femoral reconstruction intramedullary nail.
1. Better Purchase Prices Of femoral reconstruction intramedullary nail.
2.100% The Highest Quality femoral reconstruction intramedullary nail.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient femoral reconstruction intramedullary nail.
6. Quick And Easy Assessment Of XC Medico's femoral reconstruction intramedullary nail.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Femoral reconstruction intramedullary (IM) nail surgery is an orthopedic procedure used to treat complex fractures or reconstruct the femur (thigh bone) when its structure is compromised. This surgery involves inserting a long metal rod, called a reconstruction IM nail, into the central cavity (medullary canal) of the femur to stabilize the bone, allowing it to heal properly. It is typically used for fractures that involve both the shaft and proximal (upper) part of the femur, such as those near the hip or in cases where previous fractures have failed to heal.
These nails often incorporate advanced locking mechanisms, such as dual-locking or self-locking screws, to ensure the nail remains securely in place and prevent implant failure.
They are made of biocompatible materials, such as titanium or stainless steel, to minimize the risk of allergic reactions or tissue irritation.
Femoral reconstruction nails can often be customized to fit the specific needs of the patient and the fracture pattern, enhancing the accuracy and effectiveness of the procedure.
These nails are designed to withstand higher loads and stresses, making them suitable for complex fractures and demanding activities.
By providing optimal stability and support, femoral reconstruction nails can help restore normal function and mobility to the affected leg.
Some nails may incorporate anti-rotation features to prevent the nail from rotating within the femur, which can be important in certain fracture patterns.
Distal locking options may be available to provide additional stability and prevent the nail from migrating within the bone.
Femoral reconstructive intramedullary nail surgery often involves smaller incisions compared to other surgical options.
These nails can promote faster bone healing and reduce recovery time.
In many cases, patients may be able to start bearing weight on the affected leg sooner after surgery.
Femoral reconstructive intramedullary nails provide excellent stability to the fractured bone.
Compared to other fixation methods, these nails can lower the risk of complications, such as non-union or malunion.
First things first, the patient is anesthetized, and then they’re carefully positioned, often lying on their back. The surgeon will determine the best entry point for the nail, which is typically near the hip.
Next, the surgeon makes a small incision, creating an opening in the top of the femur. This is where the nail will be inserted. A guidewire is then used to ensure precise placement.
The medullary canal (the hollow part inside your femur) is reamed out to make space for the nail. Think of this step as creating a perfectly-sized tunnel for the nail to fit inside.
Once the tunnel is ready, the intramedullary nail is carefully inserted. It’s threaded down into the femur with the help of fluoroscopy (a live X-ray) to ensure everything’s aligned properly.
The final step involves securing the nail with screws at both ends. This “locks” the nail into position, ensuring the bone fragments don’t move during healing.
Maintaining a clean wound and following post-surgical care instructions is crucial.
If the bone doesn't heal properly, further surgery may be needed.
In rare cases, the implant may break or loosen.
There's a risk of nerve injury during the surgery.
The leg may be immobilized in a cast or brace.
Rehabilitation exercises are essential for regaining strength and range of motion.
Gradual weight-bearing is typically allowed as the bone heals.
Keep the incision clean and dry. Your doctor will give you instructions on how to take care of it. You’ll also need to monitor the site for any signs of infection, like redness or swelling.
During this period, you’ll be doing light movement with partial weight-bearing, likely with the help of crutches or a walker. Don’t push yourself too hard—this is the time to rest and let the bone start healing.
You'll start to put more weight on your leg as the healing progresses. This is where physical therapy really kicks in, focusing on strengthening and increasing your range of motion.
By now, you should be able to walk without assistance and resume many of your normal activities. High-impact activities like running, however, are still off the table.
Full recovery can take up to a year, especially for severe fractures.
According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including femoral reconstruction intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers.
The demand for femoral reconstructive intramedullary nails is expected to continue growing due to factors like an aging population and increasing rates of bone fractures.With advancements in materials, design, and surgical techniques, the demand for these nails is expected.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | REFTitanium Alloy | Specification |
Femoral Reconstruction Intramedullary Nail match 4.5mm locking screw6.0mm locking screw Full-threaded | RG2CJSD09320L | Ф9×320 L | |
RG2CJSD09340L | Ф9×340 L | ||
RG2CJSD09360L | Ф9×360 L | ||
RG2CJSD09380L | Ф9×380 L | ||
RG2CJSD09400L | Ф9×400 L | ||
RG2CJSD09420L | Ф9×420 L | ||
RG2CJSD09320R | Ф9×320 R | ||
RG2CJSD09340R | Ф9×340 R | ||
RG2CJSD09360R | Ф9×360 R | ||
RG2CJSD09380R | Ф9×380 R | ||
RG2CJSD09400R | Ф9×400 R | ||
RG2CJSD09420R | Ф9×420 R | ||
RG2CJSD10320L | Ф10×320 L | ||
RG2CJSD10340L | Ф10×340 L | ||
RG2CJSD10360L | Ф10x360 L | ||
RG2CJSD10380L | Ф10×380 L | ||
RG2CJSD10400L | Ф10×400 L | ||
RG2CJSD10420L | Ф10×420 L | ||
RG2CJSD10320R | Ф10×320 R | ||
RG2CJSD10340R | Ф10×340 R | ||
RG2CJSD10360R | Ф10x360 R | ||
RG2CJSD10380R | Ф10×380 R | ||
RG2CJSD10400R | Ф10×400 R | ||
RG2CJSD10420R | Ф10×420 R | ||
RG2CJSD11320L | Ф11x320 L | ||
RG2CJSD11340L | Ф11x340 L | ||
RG2CJSD11360L | Ф11x360 L | ||
RG2CJSD11380L | Ф11x380 L | ||
RG2CJSD11400L | Ф11x400 L | ||
RG2CJSD11420L | Ф11x420 L | ||
RG2CJSD11320R | Ф11x320 R | ||
RG2CJSD11340R | Ф11x340 R | ||
RG2CJSD11360R | Ф11x360 R | ||
RG2CJSD11380R | Ф11x380 R | ||
RG2CJSD11400R | Ф11x400 R | ||
RG2CJSD11420R | Ф11x420 R |
Standard Locking IndicationsThe Antegrade Femoral Nail with standard locking is indicated for fractures in the femoral shaft. |
Recon Locking IndicationsThe Antegrade Femoral Nail with recon locking is indicated for fractures in the femoral shaft in case of combination with femoral neck fractures. Additionally, the Antegrade Femoral Nail is indicated for fractures in the subtrochanteric section. |
AFN Implants:Standard locking implantsProximal diameters:9-11mm 4.7 mm Locking Bolt Lengths 26-84mm (in 2 mm increments) Anatomical 6 MLangle 1500 mm bending radius Cannulated for reamed/undreamed insertion Lengths 320-420 mm (in 20mm increments) The Antegrade Femoral Nail(AFN) is available in titanium alloy A choice of static or dynamic interlocking. |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask XC Medico team for femoral reconstruction intramedullary nail product catalog.
2. Choose your interested femoral reconstruction intramedullary nail product.
3. Ask for a sample to test femoral reconstruction intramedullary nail quality.
4.Make an order of XC Medico's femoral reconstruction intramedullary nail.
5.Become a dealer of XC medico's femoral reconstruction intramedullary nail.
1. Better Purchase Prices Of femoral reconstruction intramedullary nail.
2.100% The Highest Quality femoral reconstruction intramedullary nail.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient femoral reconstruction intramedullary nail.
6. Quick And Easy Assessment Of XC Medico's femoral reconstruction intramedullary nail.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Femoral reconstruction intramedullary (IM) nail surgery is an orthopedic procedure used to treat complex fractures or reconstruct the femur (thigh bone) when its structure is compromised. This surgery involves inserting a long metal rod, called a reconstruction IM nail, into the central cavity (medullary canal) of the femur to stabilize the bone, allowing it to heal properly. It is typically used for fractures that involve both the shaft and proximal (upper) part of the femur, such as those near the hip or in cases where previous fractures have failed to heal.
These nails often incorporate advanced locking mechanisms, such as dual-locking or self-locking screws, to ensure the nail remains securely in place and prevent implant failure.
They are made of biocompatible materials, such as titanium or stainless steel, to minimize the risk of allergic reactions or tissue irritation.
Femoral reconstruction nails can often be customized to fit the specific needs of the patient and the fracture pattern, enhancing the accuracy and effectiveness of the procedure.
These nails are designed to withstand higher loads and stresses, making them suitable for complex fractures and demanding activities.
By providing optimal stability and support, femoral reconstruction nails can help restore normal function and mobility to the affected leg.
Some nails may incorporate anti-rotation features to prevent the nail from rotating within the femur, which can be important in certain fracture patterns.
Distal locking options may be available to provide additional stability and prevent the nail from migrating within the bone.
Femoral reconstructive intramedullary nail surgery often involves smaller incisions compared to other surgical options.
These nails can promote faster bone healing and reduce recovery time.
In many cases, patients may be able to start bearing weight on the affected leg sooner after surgery.
Femoral reconstructive intramedullary nails provide excellent stability to the fractured bone.
Compared to other fixation methods, these nails can lower the risk of complications, such as non-union or malunion.
First things first, the patient is anesthetized, and then they’re carefully positioned, often lying on their back. The surgeon will determine the best entry point for the nail, which is typically near the hip.
Next, the surgeon makes a small incision, creating an opening in the top of the femur. This is where the nail will be inserted. A guidewire is then used to ensure precise placement.
The medullary canal (the hollow part inside your femur) is reamed out to make space for the nail. Think of this step as creating a perfectly-sized tunnel for the nail to fit inside.
Once the tunnel is ready, the intramedullary nail is carefully inserted. It’s threaded down into the femur with the help of fluoroscopy (a live X-ray) to ensure everything’s aligned properly.
The final step involves securing the nail with screws at both ends. This “locks” the nail into position, ensuring the bone fragments don’t move during healing.
Maintaining a clean wound and following post-surgical care instructions is crucial.
If the bone doesn't heal properly, further surgery may be needed.
In rare cases, the implant may break or loosen.
There's a risk of nerve injury during the surgery.
The leg may be immobilized in a cast or brace.
Rehabilitation exercises are essential for regaining strength and range of motion.
Gradual weight-bearing is typically allowed as the bone heals.
Keep the incision clean and dry. Your doctor will give you instructions on how to take care of it. You’ll also need to monitor the site for any signs of infection, like redness or swelling.
During this period, you’ll be doing light movement with partial weight-bearing, likely with the help of crutches or a walker. Don’t push yourself too hard—this is the time to rest and let the bone start healing.
You'll start to put more weight on your leg as the healing progresses. This is where physical therapy really kicks in, focusing on strengthening and increasing your range of motion.
By now, you should be able to walk without assistance and resume many of your normal activities. High-impact activities like running, however, are still off the table.
Full recovery can take up to a year, especially for severe fractures.
According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including femoral reconstruction intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers.
The demand for femoral reconstructive intramedullary nails is expected to continue growing due to factors like an aging population and increasing rates of bone fractures.With advancements in materials, design, and surgical techniques, the demand for these nails is expected.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact