RPZTS
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | Ref | Specification | Screw |
Oblique-angled T-shaped Locking Plate | RPZTS4HR | 4 H R | HA3.5 HC3.5 | |
RPZTS4HL | 4 H L | HA3.5 HC3.5 | ||
RPZTS5HR | 5 H R | HA3.5 HC3.5 | ||
RPZTS5HL | 5 H L | HA3.5 HC3.5 | ||
RPZTS6HR | 6 H R | HA3.5 HC3.5 | ||
RPZTS6HL | 6 H L | HA3.5 HC3.5 | ||
RPZTS7HR | 7 H R | HA3.5 HC3.5 | ||
RPZTS7HL | 7 H L | HA3.5 HC3.5 | ||
RPZTS8HR | 8 H R | HA3.5 HC3.5 | ||
RPZTS8HL | 8 H L | HA3.5 HC3.5 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Oblique-angled T-shaped Locking Plate Product Catalog.
2. Choose Your Interested Oblique-angled T-shaped Locking Plate Product.
3. Ask For A Sample To Test Oblique-angled T-shaped Locking Plate.
4.Make An Order Of XC Medico's Oblique-angled T-shaped Locking Plate.
5.Become A Dealer Of XC Medico's Oblique-angled T-shaped Locking Plate.
1.Better Purchase Prices Of Oblique-angled T-shaped Locking Plate.
2.100% The Highest Quality Oblique-angled T-shaped Locking Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Oblique-angled T-shaped Locking Plate.
6. Quick And Easy Assessment Of XC Medico's Oblique-angled T-shaped Locking Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The Oblique-angled T-shaped Locking Plate is a versatile orthopedic implant designed to stabilize complex fractures with oblique and T-shaped geometries. With advanced engineering, this implant addresses the challenges of achieving secure fixation in anatomically demanding areas. This guide provides a detailed understanding of its concept, features, advantages, and applications in modern fracture management.
The Oblique-angled T-shaped Locking Plate is a specialized implant used for internal fixation of fractures in bones with oblique orientations or intersecting planes.
- Anatomical design: The plate shape accommodate radius anatomy,fits close to minimize soft tissue irration.
- Combination locking and compression holes(combi holes):using angular stability or compression according to the requirements.
- LCP lengthen compression holes are used for adjusting the bone plates postion.
- Tapered end is used for insertion to keep tissue viability.
locking screw holes.
Anatomic shape fits close to thevolar ridge with rounded edges tominimize soft tissue irritation.
Combi-holes combine a DCU hole with a threaded locking hole.
Elongated LCP Combi hole for plate positioning and radius length adjustment.
Ensures stable fixation of oblique fractures in long bones, preventing displacement during healing.
Effectively reconstructs and stabilizes joint surfaces in fractures with intersecting planes, such as intra-articular fractures.
The locking mechanism and multi-point fixation provide secure stabilization in fragmented bone fractures.
Surgical site infections can occur, requiring diligent aseptic techniques and post-operative care.
Improper screw placement or excessive plate prominence can lead to soft tissue irritation or nerve compression.
Rare instances of screw loosening or plate breakage may necessitate revision surgery.
An aging population and increasing traumatic injuries drive the need for implants capable of managing complex fractures.
Emerging technologies, such as 3D printing and bioabsorbable materials, promise to enhance the functionality and application of such implants.
Increased adoption in developing countries, supported by improved healthcare infrastructure, is expected to boost market growth.
The Oblique-angled T-shaped Locking Plate is a game-changer in orthopedic trauma management. Its advanced design, anatomical compatibility, and robust fixation capabilities make it indispensable for treating oblique and multi-plane fractures. While challenges persist, ongoing innovations and increasing demand ensure a bright future for this implant in global orthopedic practices.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | Ref | Specification | Screw |
Oblique-angled T-shaped Locking Plate | RPZTS4HR | 4 H R | HA3.5 HC3.5 | |
RPZTS4HL | 4 H L | HA3.5 HC3.5 | ||
RPZTS5HR | 5 H R | HA3.5 HC3.5 | ||
RPZTS5HL | 5 H L | HA3.5 HC3.5 | ||
RPZTS6HR | 6 H R | HA3.5 HC3.5 | ||
RPZTS6HL | 6 H L | HA3.5 HC3.5 | ||
RPZTS7HR | 7 H R | HA3.5 HC3.5 | ||
RPZTS7HL | 7 H L | HA3.5 HC3.5 | ||
RPZTS8HR | 8 H R | HA3.5 HC3.5 | ||
RPZTS8HL | 8 H L | HA3.5 HC3.5 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Oblique-angled T-shaped Locking Plate Product Catalog.
2. Choose Your Interested Oblique-angled T-shaped Locking Plate Product.
3. Ask For A Sample To Test Oblique-angled T-shaped Locking Plate.
4.Make An Order Of XC Medico's Oblique-angled T-shaped Locking Plate.
5.Become A Dealer Of XC Medico's Oblique-angled T-shaped Locking Plate.
1.Better Purchase Prices Of Oblique-angled T-shaped Locking Plate.
2.100% The Highest Quality Oblique-angled T-shaped Locking Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Oblique-angled T-shaped Locking Plate.
6. Quick And Easy Assessment Of XC Medico's Oblique-angled T-shaped Locking Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The Oblique-angled T-shaped Locking Plate is a versatile orthopedic implant designed to stabilize complex fractures with oblique and T-shaped geometries. With advanced engineering, this implant addresses the challenges of achieving secure fixation in anatomically demanding areas. This guide provides a detailed understanding of its concept, features, advantages, and applications in modern fracture management.
The Oblique-angled T-shaped Locking Plate is a specialized implant used for internal fixation of fractures in bones with oblique orientations or intersecting planes.
- Anatomical design: The plate shape accommodate radius anatomy,fits close to minimize soft tissue irration.
- Combination locking and compression holes(combi holes):using angular stability or compression according to the requirements.
- LCP lengthen compression holes are used for adjusting the bone plates postion.
- Tapered end is used for insertion to keep tissue viability.
locking screw holes.
Anatomic shape fits close to thevolar ridge with rounded edges tominimize soft tissue irritation.
Combi-holes combine a DCU hole with a threaded locking hole.
Elongated LCP Combi hole for plate positioning and radius length adjustment.
Ensures stable fixation of oblique fractures in long bones, preventing displacement during healing.
Effectively reconstructs and stabilizes joint surfaces in fractures with intersecting planes, such as intra-articular fractures.
The locking mechanism and multi-point fixation provide secure stabilization in fragmented bone fractures.
Surgical site infections can occur, requiring diligent aseptic techniques and post-operative care.
Improper screw placement or excessive plate prominence can lead to soft tissue irritation or nerve compression.
Rare instances of screw loosening or plate breakage may necessitate revision surgery.
An aging population and increasing traumatic injuries drive the need for implants capable of managing complex fractures.
Emerging technologies, such as 3D printing and bioabsorbable materials, promise to enhance the functionality and application of such implants.
Increased adoption in developing countries, supported by improved healthcare infrastructure, is expected to boost market growth.
The Oblique-angled T-shaped Locking Plate is a game-changer in orthopedic trauma management. Its advanced design, anatomical compatibility, and robust fixation capabilities make it indispensable for treating oblique and multi-plane fractures. While challenges persist, ongoing innovations and increasing demand ensure a bright future for this implant in global orthopedic practices.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact