You are here: Home » Products » Trauma System » Intramedullary Nail » Intramedullary Nail Implant » Reversed Femoral Intramedullary Nail

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Reversed Femoral Intramedullary Nail

  • RG2NXSD

  • XCmedico

  • 1 Pcs(72 Hours Delivery)

  • Femoral

  • Titanium  Alloy Or Stainless Steel

  • CE/ISO:9001/ISO13485.Etc

  • Custom-Made 15 Days Delivery(Excluding Shipping Time)

  • FedEx. DHL.TNT.EMS.Etc

Availability:
Quantity:

Reversed Femoral Intramedullary Nail Video


Reversed Femoral Intramedullary Nail PDF


Reversed Femoral Intramedullary Nail Specification

Product Picture REF Titanium Alloy Specification
Reversed Femoral Intramedullary Nail match 4.5mm locking screw Full-threaded Reversed Femoral Intramedullary Nail RG2NXSD09200 Ф9×200
RG2NXSD09220 Ф9×220
RG2NXSD09240 Ф9×240
RG2NXSD09260 Ф9×260
RG2NXSD09280 Ф9×280
RG2NXSD09300 Ф9×300
RG2NXSD10200 Ф10×200
RG2NXSD10220 Ф10×220
RG2NXSD10240 Ф10×240
RG2NXSD10260 Ф10×260
RG2NXSD10280 Ф10×280
RG2NXSD10300 Ф10×300
RG2NXSD11200 Ф11×200
RG2NXSD11220 Ф11×220
RG2NXSD11240 Ф11×240
RG2NXSD11260 Ф11×260
RG2NXSD11280 Ф11×280
RG2NXSD11300 Ф11×300


Reversed Femoral Intramedullary Nail Description

Reversed Femoral Intramedullary Nail-2


Reversed Nail Insert from the knee

The injury of soft tissue and periosteum around the fracture is reduced by inserting the Reversed Femoral intramedullary nail from the knee joint.

Reversed Femoral Intramedullary Nail-3


More Choices

Material, Diameter, Length


·Material: Titanium & Stainless Steel

·Diameter: From 9mm/10mm/11mm

.Length: From 200mm/220mm/240mm/260mm/280mm/ 300mm

·Screw:4.5mm Full-threaded Locking Screw

Reversed Femoral Intramedullary Nail-4


Cannulated Design

By drilling the solid nail into a cannulated one, ensures the strength and hardness of the Reversed Femoral intramedullary nail.



Advantages of  XC Medico's Products

Initial product processing

      CNC  preliminary processing


The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans.


Polishing products

          Product polishing


The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant.

Quality Inspection

         Quality Inspection


The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability.

Product package

     Product package


Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety.

Productwarehouse     Product Warehouse


The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment.

sample room     Sample Room


The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training.



The Process To Cooperate With XC Medico 

1. Ask XC Medico team for Reversed Femoral intramedullary nail  product catalog.


2. Choose your interested Reversed Femoral intramedullary nail product.


3. Ask for a sample to test Reversed Femoral intramedullary nail quality.


4.Make an order of XC Medico's Reversed Femoral intramedullary nail.


5.Become a dealer of  XC medico's Reversed Femoral intramedullary nail.



The Advantages To Be A Dealer Or Wholesaler Of  XC Medico

1. Better Purchase Prices Of Reversed Femoral intramedullary nail.


2.100% The Highest Quality Reversed Femoral intramedullary nail.


3. Less Ordering Efforts.


4. Price Stability For The Period Of Agreement.


5. Sufficient Reversed Femoral intramedullary nail Inventory


6. Quick And Easy Assessment Of XC Medico's Reversed Femoral intramedullary nail.


7. A Globally Recognized Brand - XC medico.


8. Fast Access Time To XC Medico Sales Team.


9. Additional Quality Test By XC Medico Team.


10. Track Your XC Medico Order From Start To Finish.



Reversed Femoral Intramedullary Nail Concept

Reversed Femoral intramedullary nail is a special type of intramedullary nail used to treat distal femoral fractures. It has good mechanical stability and can effectively control the posterior displacement and rotational displacement of the distal end of the fracture. Unlike traditional femoral intramedullary nails that are inserted from the distal end of the femur (knee), the reverse nail is inserted from the proximal end (hip).



Reversed Femoral Intramedullary Nail Features

Proximal Insertion

The nail is inserted from the proximal end (hip) of the femur, allowing for better stability in fractures near the hip joint.

Specialized Design

Reversed nails often have a slightly different design or curvature to accommodate the proximal insertion point and provide optimal alignment.

Locking Mechanisms

They may use the same locking mechanisms as traditional nails, such as locking screws, to secure the nail to the bone.

Material

Reversed nails are typically made of the same materials as traditional nails, such as stainless steel or titanium, ensuring strength and biocompatibility.

Customization

Like traditional nails, reversed nails can be customized in terms of size, length, and design to suit the individual patient's needs and fracture pattern.



Reversed Femoral Intramedullary Nail Advantages

Improved Stability

The proximal insertion point can provide better stability in fractures near the hip joint, especially in cases where traditional nails may struggle to maintain alignment.

Reduced Risk of Complications

In some cases, the reversed approach may reduce the risk of complications such as nonunion or malunion, particularly in complex fractures.

Fewer Surgical Steps

The reversed approach may require fewer surgical steps compared to traditional nails, potentially reducing the risk of complications and improving patient outcomes.

Better Bone Healing

The reversed approach can sometimes promote better bone healing in certain f

Reversed Femoral Intramedullary Nail Surge

The femoral intramedullary (IM) nail is an orthopedic implant used to stabilize fractures in the femur, the thigh bone. This concept relies on placing a long metal rod within the hollow medullary canal of the femur, which helps align and stabilize the bone during the healing process.


Incision

A small incision is made near the hip joint.

Nail Insertion

The reversed intramedullary nail is inserted into the medullary canal, the hollow center of the femur.

Locking

Locking screws are placed above and below the fracture site to secure the nail and prevent it from moving.

Closure

The incision is closed with stitches or surgical glue.



Reversed Femoral Intramedullary Nail Complications And Precautions

Potential Complications

Infection

Non-union or Delayed Union

Anterior Knee Pain and Stiffness

Nerve and Vascular Injury

Compartment Syndrome

Thrombosis (Blood Clots)

Hip Joint Involvement

Precautions

Gradual Weight-Bearing and Mobility

Physical Therapy

Monitoring for Compartment Syndrome

Blood Clot Prevention

Avoiding High-impact Activities



Reversed Femoral Intramedullary Nail Postoperative Care

Postoperative care following reversed femoral intramedullary (IM) nail surgery is crucial for promoting healing, reducing complications, and ensuring a successful recovery. The focus is Pain Management、 Wound Care、Weight-Bearing and Mobility、Physical Therapy、 Activity Restrictions、Monitoring for Complications、Follow-up Appointments、Nutrition and Lifestyle、Long-term Recovery and Rehabilitation.



How Soon After Reversed Femoral Intramedullary Nail Postoperative Surgery Can I Be Active?

The timeline for returning to activity after reversed femoral intramedullary nail surgery depends on the type of fracture, stability of the repair, and individual healing progress. Generally, recovery and activity levels are guided by your surgeon and physical therapist, Normal activities can be resumed after 6 months.



The Future Market For Reversed Femoral Intramedullary Nail

According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including reversed femoral intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers‌.


Summary

Reverse femoral intramedullary nailing is an effective treatment method, especially for certain types of femoral fractures. It has the advantages of good stability and low risk of complications. However, whether to choose to use a reverse nail needs to be decided by the orthopedic surgeon based on the patient's specific situation.


Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.

Previous: 
Next: 

Contact With Us Now!

We have an extremely strict delivery process,from sample approval to final product delivery, and then to shipment confirmation, which allow us more close to your accurate demand and requirement.
XC Medico is leading orthopedic implants and instruments distributor and manufacturer in China. We provide trauma systems, spine systems, CMF/maxillofacial systems, sport medicine systems, joint systems, external fixator systems, orthopedic instruments, and medical power tools.

Quick Links

Contact

Tianan Cyber City, Changwu Middle Road, Changzhou, China
86-18961187889

Keep In Touch

To know more about XC Medico, please subscribe our Youtube channel, or follow us on Linkedin or Facebook. We’ll keep updating our information for you.
© COPYRIGHT 2024 CHANGZHOU XC MEDICO TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.