RG2NXSD
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Titanium Alloy Or Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | REF Titanium Alloy | Specification |
Reversed Femoral Intramedullary Nail match 4.5mm locking screw Full-threaded | RG2NXSD09200 | Ф9×200 | |
RG2NXSD09220 | Ф9×220 | ||
RG2NXSD09240 | Ф9×240 | ||
RG2NXSD09260 | Ф9×260 | ||
RG2NXSD09280 | Ф9×280 | ||
RG2NXSD09300 | Ф9×300 | ||
RG2NXSD10200 | Ф10×200 | ||
RG2NXSD10220 | Ф10×220 | ||
RG2NXSD10240 | Ф10×240 | ||
RG2NXSD10260 | Ф10×260 | ||
RG2NXSD10280 | Ф10×280 | ||
RG2NXSD10300 | Ф10×300 | ||
RG2NXSD11200 | Ф11×200 | ||
RG2NXSD11220 | Ф11×220 | ||
RG2NXSD11240 | Ф11×240 | ||
RG2NXSD11260 | Ф11×260 | ||
RG2NXSD11280 | Ф11×280 | ||
RG2NXSD11300 | Ф11×300 |
Reversed Nail Insert from the kneeThe injury of soft tissue and periosteum around the fracture is reduced by inserting the Reversed Femoral intramedullary nail from the knee joint. |
More ChoicesMaterial, Diameter, Length ·Material: Titanium & Stainless Steel ·Diameter: From 9mm/10mm/11mm .Length: From 200mm/220mm/240mm/260mm/280mm/ 300mm ·Screw:4.5mm Full-threaded Locking Screw |
Cannulated DesignBy drilling the solid nail into a cannulated one, ensures the strength and hardness of the Reversed Femoral intramedullary nail. |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask XC Medico team for Reversed Femoral intramedullary nail product catalog.
2. Choose your interested Reversed Femoral intramedullary nail product.
3. Ask for a sample to test Reversed Femoral intramedullary nail quality.
4.Make an order of XC Medico's Reversed Femoral intramedullary nail.
5.Become a dealer of XC medico's Reversed Femoral intramedullary nail.
1. Better Purchase Prices Of Reversed Femoral intramedullary nail.
2.100% The Highest Quality Reversed Femoral intramedullary nail.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Reversed Femoral intramedullary nail Inventory
6. Quick And Easy Assessment Of XC Medico's Reversed Femoral intramedullary nail.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Reversed Femoral intramedullary nail is a special type of intramedullary nail used to treat distal femoral fractures. It has good mechanical stability and can effectively control the posterior displacement and rotational displacement of the distal end of the fracture. Unlike traditional femoral intramedullary nails that are inserted from the distal end of the femur (knee), the reverse nail is inserted from the proximal end (hip).
The nail is inserted from the proximal end (hip) of the femur, allowing for better stability in fractures near the hip joint.
Reversed nails often have a slightly different design or curvature to accommodate the proximal insertion point and provide optimal alignment.
They may use the same locking mechanisms as traditional nails, such as locking screws, to secure the nail to the bone.
Reversed nails are typically made of the same materials as traditional nails, such as stainless steel or titanium, ensuring strength and biocompatibility.
Like traditional nails, reversed nails can be customized in terms of size, length, and design to suit the individual patient's needs and fracture pattern.
The proximal insertion point can provide better stability in fractures near the hip joint, especially in cases where traditional nails may struggle to maintain alignment.
In some cases, the reversed approach may reduce the risk of complications such as nonunion or malunion, particularly in complex fractures.
The reversed approach may require fewer surgical steps compared to traditional nails, potentially reducing the risk of complications and improving patient outcomes.
The reversed approach can sometimes promote better bone healing in certain f
The femoral intramedullary (IM) nail is an orthopedic implant used to stabilize fractures in the femur, the thigh bone. This concept relies on placing a long metal rod within the hollow medullary canal of the femur, which helps align and stabilize the bone during the healing process.
A small incision is made near the hip joint.
The reversed intramedullary nail is inserted into the medullary canal, the hollow center of the femur.
Locking screws are placed above and below the fracture site to secure the nail and prevent it from moving.
The incision is closed with stitches or surgical glue.
Infection
Non-union or Delayed Union
Anterior Knee Pain and Stiffness
Nerve and Vascular Injury
Compartment Syndrome
Thrombosis (Blood Clots)
Hip Joint Involvement
Gradual Weight-Bearing and Mobility
Physical Therapy
Monitoring for Compartment Syndrome
Blood Clot Prevention
Avoiding High-impact Activities
Postoperative care following reversed femoral intramedullary (IM) nail surgery is crucial for promoting healing, reducing complications, and ensuring a successful recovery. The focus is Pain Management、 Wound Care、Weight-Bearing and Mobility、Physical Therapy、 Activity Restrictions、Monitoring for Complications、Follow-up Appointments、Nutrition and Lifestyle、Long-term Recovery and Rehabilitation.
The timeline for returning to activity after reversed femoral intramedullary nail surgery depends on the type of fracture, stability of the repair, and individual healing progress. Generally, recovery and activity levels are guided by your surgeon and physical therapist, Normal activities can be resumed after 6 months.
According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including reversed femoral intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers.
Reverse femoral intramedullary nailing is an effective treatment method, especially for certain types of femoral fractures. It has the advantages of good stability and low risk of complications. However, whether to choose to use a reverse nail needs to be decided by the orthopedic surgeon based on the patient's specific situation.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | REF Titanium Alloy | Specification |
Reversed Femoral Intramedullary Nail match 4.5mm locking screw Full-threaded | RG2NXSD09200 | Ф9×200 | |
RG2NXSD09220 | Ф9×220 | ||
RG2NXSD09240 | Ф9×240 | ||
RG2NXSD09260 | Ф9×260 | ||
RG2NXSD09280 | Ф9×280 | ||
RG2NXSD09300 | Ф9×300 | ||
RG2NXSD10200 | Ф10×200 | ||
RG2NXSD10220 | Ф10×220 | ||
RG2NXSD10240 | Ф10×240 | ||
RG2NXSD10260 | Ф10×260 | ||
RG2NXSD10280 | Ф10×280 | ||
RG2NXSD10300 | Ф10×300 | ||
RG2NXSD11200 | Ф11×200 | ||
RG2NXSD11220 | Ф11×220 | ||
RG2NXSD11240 | Ф11×240 | ||
RG2NXSD11260 | Ф11×260 | ||
RG2NXSD11280 | Ф11×280 | ||
RG2NXSD11300 | Ф11×300 |
Reversed Nail Insert from the kneeThe injury of soft tissue and periosteum around the fracture is reduced by inserting the Reversed Femoral intramedullary nail from the knee joint. |
More ChoicesMaterial, Diameter, Length ·Material: Titanium & Stainless Steel ·Diameter: From 9mm/10mm/11mm .Length: From 200mm/220mm/240mm/260mm/280mm/ 300mm ·Screw:4.5mm Full-threaded Locking Screw |
Cannulated DesignBy drilling the solid nail into a cannulated one, ensures the strength and hardness of the Reversed Femoral intramedullary nail. |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask XC Medico team for Reversed Femoral intramedullary nail product catalog.
2. Choose your interested Reversed Femoral intramedullary nail product.
3. Ask for a sample to test Reversed Femoral intramedullary nail quality.
4.Make an order of XC Medico's Reversed Femoral intramedullary nail.
5.Become a dealer of XC medico's Reversed Femoral intramedullary nail.
1. Better Purchase Prices Of Reversed Femoral intramedullary nail.
2.100% The Highest Quality Reversed Femoral intramedullary nail.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Reversed Femoral intramedullary nail Inventory
6. Quick And Easy Assessment Of XC Medico's Reversed Femoral intramedullary nail.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Reversed Femoral intramedullary nail is a special type of intramedullary nail used to treat distal femoral fractures. It has good mechanical stability and can effectively control the posterior displacement and rotational displacement of the distal end of the fracture. Unlike traditional femoral intramedullary nails that are inserted from the distal end of the femur (knee), the reverse nail is inserted from the proximal end (hip).
The nail is inserted from the proximal end (hip) of the femur, allowing for better stability in fractures near the hip joint.
Reversed nails often have a slightly different design or curvature to accommodate the proximal insertion point and provide optimal alignment.
They may use the same locking mechanisms as traditional nails, such as locking screws, to secure the nail to the bone.
Reversed nails are typically made of the same materials as traditional nails, such as stainless steel or titanium, ensuring strength and biocompatibility.
Like traditional nails, reversed nails can be customized in terms of size, length, and design to suit the individual patient's needs and fracture pattern.
The proximal insertion point can provide better stability in fractures near the hip joint, especially in cases where traditional nails may struggle to maintain alignment.
In some cases, the reversed approach may reduce the risk of complications such as nonunion or malunion, particularly in complex fractures.
The reversed approach may require fewer surgical steps compared to traditional nails, potentially reducing the risk of complications and improving patient outcomes.
The reversed approach can sometimes promote better bone healing in certain f
The femoral intramedullary (IM) nail is an orthopedic implant used to stabilize fractures in the femur, the thigh bone. This concept relies on placing a long metal rod within the hollow medullary canal of the femur, which helps align and stabilize the bone during the healing process.
A small incision is made near the hip joint.
The reversed intramedullary nail is inserted into the medullary canal, the hollow center of the femur.
Locking screws are placed above and below the fracture site to secure the nail and prevent it from moving.
The incision is closed with stitches or surgical glue.
Infection
Non-union or Delayed Union
Anterior Knee Pain and Stiffness
Nerve and Vascular Injury
Compartment Syndrome
Thrombosis (Blood Clots)
Hip Joint Involvement
Gradual Weight-Bearing and Mobility
Physical Therapy
Monitoring for Compartment Syndrome
Blood Clot Prevention
Avoiding High-impact Activities
Postoperative care following reversed femoral intramedullary (IM) nail surgery is crucial for promoting healing, reducing complications, and ensuring a successful recovery. The focus is Pain Management、 Wound Care、Weight-Bearing and Mobility、Physical Therapy、 Activity Restrictions、Monitoring for Complications、Follow-up Appointments、Nutrition and Lifestyle、Long-term Recovery and Rehabilitation.
The timeline for returning to activity after reversed femoral intramedullary nail surgery depends on the type of fracture, stability of the repair, and individual healing progress. Generally, recovery and activity levels are guided by your surgeon and physical therapist, Normal activities can be resumed after 6 months.
According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including reversed femoral intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers.
Reverse femoral intramedullary nailing is an effective treatment method, especially for certain types of femoral fractures. It has the advantages of good stability and low risk of complications. However, whether to choose to use a reverse nail needs to be decided by the orthopedic surgeon based on the patient's specific situation.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact