RP2JGPW
XCmedico
I-Tibia
IiPC ezi-1 (iiyure ezingama-72 zokuhanjiswa)
Ingxubevange yeTitanium
CE/ISO:9001/ISO13485.Etc
Ukuhanjiswa kweentsuku ezili-15 ngokweSiko (Ngaphandle kweXesha lokuHamba)
FedEx. DHL.TNT.EMS.Etc
| Ubukho: | |
|---|---|
| Ubuninzi: | |
| Imveliso | Pic | Screw | I-REF. | Spec. |
| I-Tibial Platform Lateral Plate-II | ![]() |
HA 4.5 HB 6.5 |
RP2JGPW5HL | 5H L |
| RP2JGPW6HL | 6H L | |||
| RP2JGPW7HL | 7H L | |||
| RP2JGPW8HL | 8H L | |||
| RP2JGPW9HL | 9H L | |||
| Umfanekiso we-RP2JGPW10HL | 10H L | |||
| RP2JGPW11HL | 11H L | |||
| RP2JGPW5HR | 5H R | |||
| RP2JGPW6HR | 6H R | |||
| RP2JGPW7HR | 7H R | |||
| RP2JGPW8HR | 8H R | |||
| RP2JGPW9HR | 9H R | |||
| RP2JGPW10HR | 10H R | |||
| RP2JGPW11HR | 11H R |
I-CNC Preliminary Processing Itekhnoloji yolawulo lwamanani ekhompyuter isetyenziselwa ukusetyenzwa ngokuchanekileyo kweemveliso ze-orthopedic. Le nkqubo ineempawu zokuchaneka okuphezulu, ukusebenza kakuhle okuphezulu, kunye nokuphindaphinda. Inokuvelisa ngokukhawuleza izixhobo zonyango ezilungelelanisiweyo ezihambelana nesakhiwo somntu kunye nokubonelela izigulane ngezicwangciso zonyango lomntu. |
Ukulungiswa kwemveliso Injongo yeemveliso ze-orthopedic zokupholisa kukuphucula uqhagamshelwano phakathi kokufakelwa kunye nezicubu zomntu, ukunciphisa uxinzelelo loxinzelelo, kunye nokuphucula ukuzinza kwexesha elide lokufakelwa. |
Ukuhlolwa koMgangatho Uvavanyo lweepropathi zemishini yeemveliso ze-orthopedic zenzelwe ukulinganisa iimeko zoxinzelelo lwamathambo omntu, ukuvavanya umthamo wokuthwala umthwalo kunye nokuqina kokufakelwa emzimbeni womntu, kunye nokuqinisekisa ukhuseleko nokuthembeka kwabo. |
Iphakheji yeMveliso Iimveliso ze-Orthopedic zipakishwe kwigumbi eliyinyumba ukuze kuqinisekiswe ukuba imveliso ifakwe kwindawo ecocekileyo, eyinyumba ukuthintela ukungcoliseka kwe-microbial kunye nokuqinisekisa ukhuseleko lotyando. |
Ukugcinwa kweemveliso zamathambo kufuna ulawulo olungqongqo lwangaphakathi nangaphandle kunye nolawulo lomgangatho ukuze kuqinisekiswe ukulandelwa kwemveliso kunye nokuthintela ukuphela okanye ukuthunyelwa okungalunganga. |
Igumbi lesampulu lisetyenziselwa ukugcina, ukubonisa nokulawula iisampulu ezahlukeneyo zeemveliso ze-orthopedic ukwenzela utshintshiselwano lweteknoloji yemveliso kunye noqeqesho. |
1. Buza iQela le-Xc Medico nge-Tibial Platform Lateral Plate-II Catalog Product.
2. Khetha i-Tibial Platform yakho enomdla kwi-Lateral Plate-II Product.
3. Cela iSampulu yokuvavanya i-Tibial Platform Lateral Plate-II.
4.Yenza i-Order ye-XC Medico's Tibial Platform Lateral Plate-II.
5.Yiba ngumthengisi we-XC Medico's Tibial Platform Lateral Plate-II.
1.Amaxabiso aNgcono okuthenga kwi-Tibial Platform Lateral Plate-II.
2.100% Elona qonga liPhakamileyo leTibial Platform Lateral Plate-II.
3. Iinzame zoku-odola ezingaphantsi.
4. Uzinzo lwexabiso ngeXesha leSivumelwano.
5. I-Tibial Platform eyaneleyo yeLateral Plate-II.
6. UVavanyo oluKhawulezayo noLulula lwe-XC Medico's Tibial Platform Lateral Plate-II.
7. I-Brand eyaziwayo kwihlabathi- XC Medico.
8. Ixesha lokuFikelela ngokukhawuleza ukuya kwiQela le-XC Medico yokuthengisa.
9. Uvavanyo olongezelelweyo loMgangatho weQela le-XC Medico.
10. Landela umkhondo wakho we-XC Medico Order ukusuka ekuqaleni ukuya ekugqibeleni.

Ukuvela kwe-orthopedic implants iyaqhubeka nokuguqula ulawulo lwe-fracture, inika izisombululo eziphuculweyo zokulimala okunzima. I-Tibial Platform Lateral Plate-II ime njengesixhobo esisulungekisiweyo esilungiselelwe ukuphuka kwe-lateral tibial plateau fractures, ukudibanisa iimpawu ezinqamlekileyo kunye nokuguquguquka kwekliniki. Eli nqaku linika inkcazo enzulu ye-Tibial Platform Lateral Plate-II, ixoxa ngeempawu zayo, iingenelo, izicelo zeklinikhi, iingozi ezinxulumene nazo, kunye neendlela ezizayo zemarike.
I-Tibial Platform Lateral Plate-II isizukulwana esilandelayo se-orthopedic implant eyenzelwe unyango lwe-lateral tibial plateau fractures. Ezi fractures zihlala zibandakanya ubunzima obunobunzima bamadolo kwaye zifuna ukulungiswa ngokuchanekileyo kwe-anatomical ukubuyisela umsebenzi odibeneyo kunye nokukhusela iingxaki zexesha elide njenge-arthritis.
Le pleyiti yakhela phezu koyilo olusisiseko lomanduleli wayo, izisa iimpawu eziphambili eziphucula uzinzo lwe-biomechanical, ukusebenza kakuhle kotyando, kunye neziphumo zesigulana. Ngokukwazi ukuzinzisa iifractures ezinzima ngelixa ugcina izicubu ezithambileyo ezijikelezayo, i-Tibial Platform Lateral Plate-II sisixhobo esibalulekileyo kwi-orthopedic operation yanamhlanje.
I-plate i-pre-contoured ukuze ihambelane ngokusondeleyo ne-curvature yendalo ye-lateral tibial plateau, iqinisekisa ukulungelelaniswa okuchanekileyo kunye nokunciphisa imfuno yokugoba kwe-intraoperative.
Inikezela ngokuhambelana nezikrufu zokutshixa ze-polyaxial, ezivumela ukuguquguquka okukhulu ekufezekiseni ukubekwa kwesikruphu okona kulungileyo.
Ukunciphisa ukucaphuka kwizicubu ezithambileyo ezijikelezayo, ukuphucula intuthuzelo yesigulane kunye nokunciphisa iingxaki emva kokuhlinzwa.
Kubandakanya i-screw trajectories ezikhethekileyo zokuqinisa ithambo le-subchondral, ukuthintela ukudilika kwendawo edibeneyo.
Ifumaneka kwiindidi ezahlukeneyo zobude kunye nobukhulu ukulungiselela iipateni ezahlukeneyo zokuphuka kunye ne-anatomies yesigulane.
Yakhiwe nge-titanium alloy, ipleyiti inika amandla abalaseleyo, ukuxhathisa ukubola, kunye ne-biocompatibility.
Uyilo lwayo lwe-screw yokutshixa luqinisekisa ukulungiswa okuqinileyo, nakwi-osteoporotic okanye i-fractures edibeneyo.
Ipleyiti iququzelela ukwakhiwa ngokutsha kwe-anatomical echanekileyo, ukugcina i-joint conngruity kunye nokuthintela isifo samathambo sesibini.
I-pre-contoured and modular, ipleyiti iyanciphisa ixesha lokulungiselela i-intraoperative, ivumela iinkqubo ezisebenzayo.
Uyilo olusezantsi lunciphisa umngcipheko wokucaphuka kwezicubu ezithambileyo, ngakumbi kwiindawo ezinokhuselo oluncinci lwezicubu ezithambileyo.
Ukulungiswa okuqinileyo kuvumela izigulane ukuba ziqale imisebenzi yokuthwala ubunzima ngokukhawuleza, ukukhuthaza ukubuyiswa ngokukhawuleza kunye neziphumo ezingcono zokusebenza.
Ilungele iipateni ezahlukeneyo zokuqhekeka, kubandakanya ukwaphuka, ukudakumba, kunye nokwaphuka okuntsonkothileyo.
Uzinzisa amaqhekeza ahlukeneyo, ukugcina ulungelelwaniso kunye nokuqinisekisa ukudibanisa okufanelekileyo okudibeneyo.
Ibonelela ngenkxaso ye-subchondral yokulungisa nokuzinzisa amacandelo amathambo acinezelekileyo, ukubuyisela indawo ye-articular.
Ukulawula ngokufanelekileyo iifractures ezibandakanya amaqhekeza amaninzi, ukunika ukuzinza ngexesha lenkqubo yokuphilisa.
Indlela yokutshixa iqinisekisa ukulungiswa okuthembekileyo kwithambo eliphantsi, ukunciphisa umngcipheko wokungaphumeleli kokufakelwa.
Uyilo oluguquguqukayo luvumela iipateni zokuqhekeka ezicela umngeni, kubandakanywa nezo zibangelwa ngumonzakalo wamandla aphezulu okanye amandla ajikelezayo.
Njengayo nayiphi na inkqubo yotyando, kukho umngcipheko wokosuleleka, ngakumbi kwizigulana ezinokhuselo lomzimba okanye iimeko eziphantsi.
Kwiimeko ezinqabileyo, izikrufu okanye iipleyiti zinokukhulula okanye zingaphumeleli, ngakumbi ukuba i-fracture ayiphili njengoko kulindelwe.
Ezinye iifractures zinokuphilisa ngokukhawuleza okanye zisilele ukudibanisa, zifuna ukungenelela okongeziweyo.
Ukubekwa ngokungafanelekanga kunokukhokelela ekungakhululeki okanye ukucaphuka kwezicubu ezijikelezileyo, okunokuthi kufuneke ukususwa kwe-hardware.
Ukubekwa kwesijivu ngokungafanelekanga okanye ubuchule botyando bunokubangela umonakalo kwimithambo-luvo ekufutshane okanye imithambo yegazi.
Nangona ingaqhelekanga, i-hypersensitivity kwizinto zokufakelwa kwezinto zinokwenzeka kwizigulana ezithintekayo.
Ukudityaniswa koshicilelo lwe-3D kunye noyilo oluqhutywa yi-AI kulindeleke ukuba luphucule uphuhliso lofakelo oluthile lwesigulane.
Ukonyuka kokwaphuka okunxulumene nobudala ngenxa ye-osteoporosis kuqhuba imfuno yezixhobo zokulungiswa eziphambili.
Ukunyuka kobuchwephesha obungenabuxhakaxhaka bokwandisa imfuno yokufakelwa kwe-anatomically contoured, iprofayile ephantsi.
Ukwandisa iziseko zoncedo lwezempilo kwimimandla ephuhlayo kudala amathuba amatsha okwamkelwa kokufakelwa.
Uphando kwizinto ezinokubolisa izinto eziphilayo kunye ne-bioresorbable lusetelwe ukuguqula ishishini lokufakelwa, ukunciphisa iingxaki zexesha elide kunye nefuthe lokusingqongileyo.
I-Tibial Platform Lateral Plate-II imele ukuqhubela phambili okuphawulekayo kunyango lwe-lateral tibial plateau fractures, ukudibanisa iimpawu ezinqamlekileyo kunye nokuguquguquka kwekliniki. Ikhono layo lokubonelela uzinzo oluphuculweyo, ukwakhiwa ngokutsha ngokubambisana okuchanekileyo, kunye nokuhlanganisa kwangethuba kwenza kube sisixhobo esixabisekileyo kuqhaqho lwamathambo.
Ngelixa kukho imingcipheko enxulumene nokusetyenziswa kwayo, izibonelelo zodlula kude iintsilelo ezinokubakho, ziqinisekisa iziphumo eziphuculweyo zezigulane kunye nokuhamba komsebenzi okulungelelanisiweyo koogqirha botyando. Njengoko imarike yokufakelwa kwe-orthopedic implants iqhubeka nokuguquka, i-Tibial Platform Lateral Plate-II kulindeleke ukuba idlale indima ebalulekileyo ekubunjweni kwekamva lolawulo lokuphuka, ukubonelela ngononophelo oluphezulu kunye neziphumo kwizigulane emhlabeni jikelele.
Isikhumbuzo esifudumeleyo: Eli nqaku lenzelwe ireferensi kuphela kwaye alinakuthatha indawo yen kokukhubazeka okubandakanya i-bilateral sagittal split osteotomy (BSSO). I-BSSO yinkqubo yotyando apho i-mandible yahlulwe ecaleni kwendiza ye-sagittal ukuvumela ukubekwa kwakhona. Emva kwe-osteotomy, iziqwenga zamathambo zikhuselekile ngokusebenzisa iiplate kunye nezikrufu ukufezekisa ukulungelelaniswa okufanelekileyo kunye nokuqinisekisa ukuzinza ngexesha lenkqubo yokuphulukisa.
Qhagamshelana