RG2GMSD
XC Medico
Femur
1 Pcs(Pangiriman 72 Jam)
Femoral
Titanium Alloy Utawa Stainless Steel
CE/ISO:9001/ISO13485
Pangiriman Custom-Made 15 Dina (Kajaba Wektu Pengiriman)
FedEx. DHL.TNT.EMS.etc
| Kasedhiyan: | |
|---|---|
| Jumlah: | |
| produk | Gambar | Paduan REFTitanium | Spesifikasi |
| Femoral Rekonstruksi Intramedullary Nail match 4.5mm/6.0mm Sekrup Pengunci Full-Threaded | ![]() |
RG2GMSD09180 | Ф9×180 |
| RG2GMSD09200 | Ф9×200 | ||
| RG2GMSD09220 | Ф9×220 | ||
| RG2GMSD09240 | Ф9×240 | ||
| RG2GMSD09260 | Ф9×260 | ||
| RG2GMSD09280 | Ф9×280 | ||
| RG2GMSD10180 | Ф10×180 | ||
| RG2GMSD10200 | Ф10×200 | ||
| RG2GMSD10220 | Ф10×220 | ||
| RG2GMSD10240 | Ф10×240 | ||
| RG2GMSD10260 | Ф10×260 | ||
| RG2GMSD10280 | Ф10×280 | ||
| RG2GMSD11180 | Ф11×180 | ||
| RG2GMSD11200 | Ф11×200 | ||
| RG2GMSD11220 | Ф11×220 | ||
| RG2GMSD11240 | Ф11×240 | ||
| RG2GMSD11260 | Ф11×260 | ||
| RG2GMSD11280 | Ф11×280 |
End CapInner screw thread desain ing mburi pucuk ndadekake luwih gampang kanggo menyuling kukumenengSaben pucuk karo 4 free ngawut-awut ngunci lan full-thread ngawut-awut ngunci Kanggo stabilitas rotasi bener. Sudut5'offset lateral kanggo entri trochanteric invasif minimal.Desain CannulatedCannulated, geometri bunder kanggo ease saka selipan nggunakake teknik reamed utawa undreamed.Lubang ngunci elips distalkanggo kompresi dinamis.Desain buntutUjung kuku distal sing fleksibel nyuda konsentrasi stres. |
Bahan baku padhet digunakake kanggo ngebor bolongan, lan bahan campuran (TC4) utawa stainless steel medis (317L) dipilih kanggo njamin kekuatan lan kekerasan kuku intramedullary. |
Cocog kanggo gulu femoral, fraktur femoral proksimal, tengah lan distal. |
Multiple specifications: Kanggo nampung anatomi pasien individu. |
Pengolahan Awal CNC Teknologi kontrol numerik komputer digunakake kanggo ngolah produk ortopedi kanthi tepat. Proses iki nduweni karakteristik presisi dhuwur, efisiensi dhuwur, lan bisa diulang. Bisa kanthi cepet ngasilake piranti medis khusus sing cocog karo struktur anatomi manungsa lan menehi rencana perawatan khusus kanggo pasien. |
Polishing produk Tujuan polishing produk ortopedi yaiku kanggo nambah kontak antarane implan lan jaringan manungsa, nyuda konsentrasi stres, lan nambah stabilitas implan jangka panjang. |
Inspeksi Kualitas Tes sifat mekanik produk ortopedi dirancang kanggo simulasi kahanan stres balung manungsa, ngevaluasi kapasitas beban lan daya tahan implan ing awak manungsa, lan njamin safety lan linuwih. |
Paket Produk Produk ortopedi dikemas ing kamar sing resik kanggo mesthekake yen produk kasebut dibungkus ing lingkungan sing resik lan steril kanggo nyegah kontaminasi mikroba lan njamin safety bedhah. |
Panyimpenan produk ortopedi mbutuhake manajemen in-and-out lan kontrol kualitas sing ketat kanggo mesthekake traceability produk lan nyegah kadaluwarsa utawa pengiriman sing salah. |
Ruang sampel digunakake kanggo nyimpen, nampilake lan ngatur macem-macem conto produk ortopedi kanggo ijol-ijolan teknologi produk lan latihan. |
1. Takon Xc Medico Team Kanggo Femoral Reconstruction Intramedullary Nail-Short Product Katalog.
2. Pilih Interested Femoral Reconstruction Intramedullary Nail-Short Product.
3. Nyuwun Sampel Kanggo Nguji Femoral Rekonstruksi Intramedullary Nail-Short Quality.
4. Nggawe Pesenan Xc Medico kang Femoral Reconstruction Intramedullary Nail-Short.
5. Dadi Dealer saka Xc Medico kang Femoral Reconstruction Intramedullary Nail-Short.
1. Prices Tuku Luwih saka Femoral Reconstruction Intramedullary Nail-Short.
2.100% Rekonstruksi Femoral Intramedullary Kuku-Short.
3. Kurang Upaya Mesen.
4. Stabilitas Price Kanggo Periode Agreement.
5. Cukup Rekonstruksi Femoral Intramedullary Nail-Short.
6. Assessment cepet lan gampang saka Xc Medico kang Femoral Reconstruction Intramedullary Nail-Short.
7. Merk sing diakoni sacara global - Xc Medico.
8. Wektu Akses Cepet Kanggo Tim Sales Xc Medico.
9. Test Quality Tambahan Miturut Xc Medico Team.
10. Lacak Pesenan Xc Medico Saka Mulai nganti Rampung.
Rekonstruksi femoral nggunakake kuku intramedullary cendhak wis dadi landasan ing operasi trauma ortopedi, nyedhiyakake stabilisasi sing luwih apik kanggo fraktur femoral. Pandhuan iki nylidiki konsep, karakteristik, kaluwihan, indikasi, risiko, lan tren pasar ing mangsa ngarep saka Femoral Reconstruction Intramedullary Nail-Short (FRIN-S), menehi wawasan sing penting kanggo para profesional ortopedi.
The Femoral Reconstruction Intramedullary Nail-Short (FRIN-S) minangka implan ortopedi khusus sing dirancang kanggo nyedhiyakake stabilisasi internal kanggo fraktur femoral. Iki minangka rod logam, biasane digawe saka titanium utawa stainless steel, dilebokake ing kanal medullary femur kanggo njaga keselarasan sing tepat lan ningkatake penyembuhan balung sing efisien. Versi cendhak saka IMN femoral utamané cocok kanggo fraktur ing femur proksimal lan pilih kasus fraktur midshaft, nawakake alternatif minimally invasif kanggo cara fiksasi tradisional.
Pre-contoured kanggo cocog karo lengkungan femoral alam kanggo alignment apik.
Akeh bolongan ngunci nyedhiyakake stabilitas rotasi lan aksial sing luwih apik.
Nyuda trauma jaringan alus nalika njaga pasokan getih periosteal.
Ngidini selipan sing dipandu kanthi gangguan minimal kanggo integritas balung.
Sawetara kuku nggabungake lapisan kayata hydroxyapatite kanggo nambah osseointegration.
Ngidini bobote lan rehabilitasi sing luwih cepet.
Kuku sing luwih cendhek mbutuhake paparan bedah sing kurang lan wektu kanggo implantasi.
Nyedhiyakake fiksasi sing stabil, nyuda kemungkinan penyembuhan sing ora bener.
Teknik invasif minimal njaga vaskularitas lan nyuda risiko infeksi.
Efektif ing macem-macem fraktur femoral lan bisa disesuaikan karo kabutuhan anatomi khusus pasien.
Becik kanggo fraktur intertrochanteric lan subtrochanteric.
Nyedhiyakake stabilitas sing nyukupi kanggo fraktur diaphyseal sing dipilih.
Digunakake ing kasus penyakit balung metastatik kanggo nyedhiyakake stabilisasi paliatif.
Bisa digunakake ing kasus nalika fiksasi ing sekitar implan dibutuhake.
Cocog kanggo kasus nalika fiksasi sadurunge gagal.
Fiksasi sing ora nyukupi bisa nyebabake pamindahan kuku.
Teknik sing ora bener bisa nyebabake malrotasi femur.
Stress risers ing ujung distal bisa nyebabake fraktur anyar.
Resiko karusakan kanggo struktur sakubenge nalika nglebokake.
Ing kasus kualitas balung sing kurang utawa stabilitas sing ora nyukupi.
Implan khusus pasien kanggo pas anatomi sing luwih apik.
Integrasi sensor kanggo ngawasi wektu nyata penyembuhan fraktur.
Terusake pangembangan pendekatan bedah perkutan.
Infrastruktur kesehatan sing mundhak ing wilayah berkembang sing nyebabake permintaan.
Bahan biokompatibel anyar sing nambah umur dawa lan integrasi.
Femoral Reconstruction Intramedullary Nail-Short (FRIN-S) wis muncul minangka solusi sing efektif banget kanggo nyetabilake fraktur femoral. Kanthi kaluwihan biomekanik, aplikasi invasif minimal, lan adaptasi kanggo macem-macem jinis fraktur, terus dadi pilihan sing disenengi ing antarane ahli bedah ortopedi. Minangka teknologi maju, masa depan FRIN-S bakal weruh inovasi luwih lanjut, ningkatake asil pasien lan efisiensi bedhah.
Pangeling-eling: Artikel iki mung kanggo referensi lan ora bisa ngganti saran profesional dhokter. Yen sampeyan duwe pitakon, hubungi dokter sing nekani.
Kontak