RP3G2KZC ezali
XCmedico oyo ezali na
Femur ya makolo
1 Pcs(72 Heures Livraison)
Alliage ya Titane
CE/ISO:9001/ISO13485.Etc., mpe bongo na bongo
Custom-Made 15 Mikolo Livraison(Kolongola Tango ya Envoi)
FedEx. DHL.TNT.EMS.Etc., mpe bongo na bongo
| Bozali na yango: | |
|---|---|
| Mingi: | |
| Eloko | Pic | Visi | REF. | Spec. |
| Plaque ya Condylus fémoral ya kokangama-III | ![]() |
HA 4,5 HB 6,5 |
RP3G2KZC5HL ezali | 5H L. Ezali na ntina mingi |
| RP3G2KZC6HL ezali | 6H L | |||
| RP3G2KZC7HL ezali | 7H L | |||
| RP3G2KZC8HL ezali | 8H L. Ezali na ntina mingi | |||
| RP3G2KZC9HL ezali | 9H L | |||
| RP3G2KZC10HL ezali na ntina mingi | 10H L. Ezali na ntina mingi | |||
| RP3G2KZC11HL ezali | 11H L. Ezali na ntina mingi | |||
| RP3G2KZC5HR ezali | 5H R | |||
| RP3G2KZC6HR ezali na ntina | 6H R | |||
| RP3G2KZC7HR ezali na ntina mingi | 7H R | |||
| RP3G2KZC8HR ezali na ntina mingi | 8H R | |||
| RP3G2KZC9HR, oyo ezali na kati | 9H R | |||
| RP3G2KZC10HR ezali na ntina | 10H R | |||
| RP3G2KZC11HR, oyo ezali na kati | 11H R |
CNC Traitement ya liboso Technologie ya contrôle numérique ya ordinateur esalelamaka mpo na kosala na bosikisiki biloko ya orthopédie. Processus oyo ezali na bizaleli ya précision ya likolo, efficacité ya likolo, mpe ya kozongela. Ekoki nokinoki kobimisa baaparɛyi ya monganga oyo ebongisami na kolanda bamposa ya bato mpe oyo ekokani na ndenge oyo nzoto ya moto esalaka mpe kopesa bato ya maladi myango ya kosalisa oyo ebongisami mpo na moto ye moko. |
Polisage ya Produit Ntina ya ko poliser biloko ya orthopédique ezali ya kobongisa contact entre implant na tissus ya moto, ko réduire concentration ya stress, mpe ko améliorer stabilité ya longue durée ya implant. |
Botali ya lolenge ya malamu Momekano ya bizaleli ya masini ya biloko ya orthopédique esalemi mpo na komekola makambo ya mpasi ya mikuwa ya moto, kotalela makoki ya komema mikumba mpe bowumeli ya biloko oyo batyaka na nzoto ya moto, mpe kosala ete ezala na likama te mpe ezala na bondimi. |
Forfait ya Biloko Biloko ya orthopédique ekangamaka na kati ya chambre stérile mpo na kosala ete produit ezala encapsulé na esika ya peto mpe stérile mpo na kopekisa contamination microbienne mpe kosala ete lipaso ezala na likama te. |
Bobombi ya biloko ya orthopédique esengaka gestion ya makasi ya in-and-out mpe contrôle ya qualité mpo na ko assurer traçabilité ya produit mpe kopekisa expiration to envoi ya mabe. |
Salle ya échantillon esalelamaka pona kobomba, kolakisa pe ko gérer ba échantillons ya ba produits orthopédiques ndenge na ndenge pona ba échanges ya technologie ya produit pe formation. |
1. Tuna Xc Medico Team Pona Catalogue ya Produit Plaque-III ya Condylus Fémoral Contrainte.
2. Pona Produit Plaque-III ya Condylus Fémorale oyo osepeli na yango.
3. Senga Échantillon Pona Ko Meka Condylus Fémorale Contrainte Plaque-III.
4.Kosala Ordre Ya Plaque Ya Condylus Fémorale Ya XC Medico-III.
5.Kokoma Motɛkisi Ya Plaque-III ya Condylus Fémorale ya XC Medico.
1.Mieux Ba prix Ya Somba Ya Condylus Fémoral Buttress Plaque-III.
2.100% Plaque ya Condylus fémorale ya qualité ya likolo-III.
3. Milende ya kosala komande mingi te.
4. Stabilité Ya Prix Pona Eleko Ya Boyokani.
5. Plaque ya Condylus Fémorale oyo ekoki-III.
6. Evaluation Noki Et Facile Ya Plaque-III Ya Condylus Fémorale Ya XC Medico.
7. Marque oyo eyebani na mokili mobimba - XC Medico.
8. Tango ya Accès Noki Na XC Medico Sales Team.
9. Momekano ya Qualité ya kobakisa Na Equipe ya XC Medico.
10. Bolanda Commande Na Yo ya XC Medico Depuis Ebandeli Ti Na Suka.
Plaque-III ya Condylus fémorale ezali komonisa solution ya liboso na traitement ya ba fractures ya condyle fémoral. Fractures ya ba condyles fémorales ezali ba blessures critiques oyo ekoki ko impacter makasi fonctionnement ya articulation ya genoux mpe mobilité mobimba ya malade. Plaque-III ya Condylus Femoral Buttress-III esalemi mpo na kopesa fixation ya likolo, ko assurer alignment mpe stabilité malamu na tango ya processus ya kobika. Buku oyo ya monene ekotala makambo, matomba, mpe bosaleli ya kliniki ya Plaque-III ya Condylus Fémoral Buttress, bakisa mpe makama na yango oyo ekoki kobima mpe makambo oyo ekosalema na zando na mikolo mizali koya.
Plaque-III ya Condylus fémoral ezali implant orthopédique oyo esalemi spécialement oyo esalelamaka mpo na ko stabiliser ba fractures ya ba condyles fémorales, oyo ezali bisika ya rond ya fémur oyo e articuler na tibia mpe esalaka eteni ya articulation ya genoux. Ba fractures na etuka oyo esalemaka mingi mingi mpo na ba traumatismes ya impact makasi, lokola kokweya, makama ya motuka, to ba blessures oyo etali masano, mpe esengaka intervention ya lipaso ya sikisiki mpo na koboya ba complications lokola arthrite post-traumatique to malalignement.
Plaque oyo esalemi mpo na kopesa ezala compression mpe stabilité na mokuwa oyo ebukani, kopekisa déplacement mosusu na tango ya processus ya kobika. Ezali na mokumba monene mpo na kozongisa mosala malamu ya matonga, kokitisa mpasi, mpe kobongisa lolenge ya bomoi ya mobɛli mobimba.
Plaque yango ezali na contour anatomique mpo ekokana mpenza na lolenge ya condyle fémoral, mpe yango ekosala ete bábongola makambo ya mindɔndɔmindɔndɔ mingi te na ntango ya lipaso.
Conception ya buttress ya plaque epesaka mécanisme ya soutien robuste oyo ezo résister ba forces compressions mpe epekisaka condyle ekweya to ebalukaka na tango ya kobika.
Plaque esalelaka ba vis ya blocage oyo e assurer connexion makasi entre plaque na mokuwa. Ezaleli yango ezali na litomba mingimingi na mikuwa oyo ezali na maladi ya mikuwa, mpamba te ekitisaka likama ya kolɛmba to kobimisa vis.
Ba versions mosusu ya plaque ezali radiolucentes, permettant na suivi facile ya processus ya guérison ya fracture na nzela ya ba rayons X sans interférence ya matériel implant.
Plaque yango esalemi mpo na kosala ete ba tissus doux oyo ezali zingazinga esilikisa mingi te. Structure na yango ya ba profils moke esalaka que ebima mingi te, ekitisaka risque ya ba complications post-opératoires lokola déhiscence ya ba mpota to inflammation ya tissus doux.
Plaque yango epesaka mabulu ndenge na ndenge ya ba vis, oyo epesaka minganga ya lipaso nzela ya kobongisa fixation na ndenge ya sikisiki ya fracture mpe qualité ya mikuwa.
Design anatomique ya plaque mpe mécanisme ya blocage epesaka stabilité excellent, oyo ezali essentiel mpo na kopekisa malalignement to nonunion na phase ya kobika.
Na fixation ya fracture oyo ebongisami, ba malades bakoki kobanda ba exercices ya kozua kilo na ebandeli mpe ya réadaptation, oyo ekitisaka mingi temps ya récupération mpe risque ya ba complications lokola atrophie ya muscle to rigidité ya articulation.
Lokola plaque ezali na profil moke ekitisaka mposa ya kokatakata mingi ba tissus doux oyo ezali zingazinga, mpe kobatela misisa, misisa mpe misisa oyo ezali na esika ya mabɔlɔngɔ.
Na kozongisaka alignment mpe stabilité ya condyle fémoral, plaque esalisaka kobatela fonctionnement ya articulation ya genoux na tango molayi, ko permettre ba malades bazonga mobility mpe bazonga na ba activités normales noki.
Na fixation na yango ya securité, Plaque-III ya Condylus Femoral Buttress ekitisaka probabilité ya ba complications lokola panne ya implant, infection, mpe retardé union.
Plaque yango ezali malamu mingi mpo na kosalisa ba fractures comminutes, epai mokuwa ebukanaka na biteni mingi. Conception ya buttress epesaka compression mpe stabilisation oyo esengeli mpo na kobatela alignment na tango ya guérison.
Na ba fractures oyo etali côté ya tension ya mokuwa, Plaque-III ya Buttress ya Condylus Fémoral esalisaka mpo na kopekisa déplacement mosusu na kopesaka soutien supplémentaire contre ba forces ya libanda.
Mpo na ba fractures oyo ezo affecter ba condyles fémorales nionso mibale, mbala mingi emonanaka na traumatisme ya énergie makasi, plaque ekoki kosalelama pona ko stabiliser ba condyles nionso mibale, kozongisa stabilité ya genoux.
Na ba maladi oyo bazali na densité ya mikuwa oyo ezali na likama, mécanisme ya blocage ya plaque esalaka que ekangama malamu, ata na mikuwa oyo ezali na osteoporose, oyo ekoki kozala na panne ya implant.
Plaque-III ya Condylus Fémorale esalemi mpo na ko gérer ba fractures oyo epanzani na esika ya matonga, kokitisa likama ya instabilité ya matonga ya ntango molai mpe ya arthrite na kozongisaka likolo ya matonga na bosikisiki.
Lokola na lipaso nyonso, ezali na likama ya kozwa mikrobe, mingimingi epai ya bato ya maladi oyo bazali na ebongiseli ya nzoto oyo ebundisaka maladi to oyo bazali na bopɛto ya mabe nsima ya lipaso.
Na makambo oyo esalemaka mingi te, plaque to ba vis ekoki kozanga, mingimingi soki fracture ekitisami malamu te to soki ba tension mécanique eleki ndelo na articulation.
Condyle fémoral ezali pene na misisa ya critique mpe misisa ya makila. Minganga oyo basalaka lipaso basengeli kokeba mpo na koboya kobebisa biloko yango na kozanga koyeba ntango bazali kosala lipaso.
Atako plaque esalemi mpo na kolendisa kobika ya mikuwa malamu, nonunion (kozanga kobika ya fracture) to malunion (kobika na position ya mabe) ekoki kaka kosalema, mingi mingi na ba fractures complexes to na ba malades oyo bazali na makoki ya kobika na ndenge ya mabe.
Bato mosusu ya maladi bakoki koyoka mpasi to kozanga komiyoka malamu na esika oyo batye yango, mingimingi soki plaque yango ekutanaki na biloko ya pɛtɛɛ oyo ezali zingazinga to soki ezali na kovimba na esika oyo basali lipaso.
Lokola motango ya makama ya nzela, bazoka ya masano, mpe kokweya ezali se kobakisama, bosenga ya bisaleli ya fixation ya liboso lokola Femoral Condylus Buttress Plate-III esengelaki komata.
Lokola bato ya mokili mobimba bazali kokóma mibange, motángo ya bato oyo babukaka mikuwa, mingimingi ba fractures osteoporose, ezali se kobakisama, mpe yango ezali kotinda bato bázala na mposa ya ba solutions ya kotyela motema mpe oyo eumelaka mpo na kokanga ba fractures.
Bobongisi oyo ezali kokoba na science ya matériaux mpe design ya implant, lokola développement ya ba plaques bioresorbables to ba mécanismes ya blocage améliorés, ekolanda ko diriger innovation na marché ya fixation ya fracture fémorale.
Kokende epai ya lipaso oyo ekɔtaka mingi te ekobakisa lisusu mposa ya biloko oyo bizali na ntina mingi te, oyo bizali na matomba mingi, oyo bikoki kosalelama na lipaso oyo ekɔtaka mingi te mpe ntango ya kobika nokinoki.
Plaque-III ya Condylus fémoral ezali implant innovateur oyo epesaka solution efficace pona ko stabiliser ba fractures ya condyle fémoral. Na design na yango ya contour anatomique, mécanisme ya vis ya blocage, mpe construction ya ba profils ya nse, epesaka fixation ya fracture améliorée tout en minimiant détérioration ya ba tissus doux. Plaque oyo ebongisaka stabilité, elendisaka réadaptation noki, mpe ekitisaka risque ya ba complications lokola nonunion, malunion, mpe panne ya implant. Atako makama ya lipaso etikali, matomba ya Plaque-III ya Condylus Femoral Buttress esalaka ete ezala esaleli oyo esengeli mpenza mpo na kosalisa ba fractures complexes condylaires fémorales. Soki totaleli liboso, ekanisami ete zando ya baaparɛyi motindo wana ekokola, mpo na bokóli ya bato oyo bazali na mpasi ya motema, motángo ya bato oyo bazali kokóma mibange, mpe bokóli oyo ezali se kokola na mayele ya kotya biloko na nzoto na mikuwa.
Rappel ya molunge: Lisolo oyo ezali kaka mpo na référence mpe ekoki te kozwa esika ya toli ya monganga ya monganga. Soki ozali na mituna, tosɛngi yo otuna monganga oyo azali kosalisa yo.
Kokutana