RP3G2KZC rehegua .
Xcmedico rehegua .
1 pcs(72 aravo'i ñeme'ẽ) .
Aleación de Titanio rehegua .
CE/ISO:9001/ISO13485.ETC
Ojejapo por encargo 15 días de entrega(Ojeexclui tiempo de envío)
FedEx rehegua. dhl.tnt.ems.etc rehegua .
Disponibilidad: . | |
---|---|
Hetakue: | |
Mba'eapopyre | Ta'angambyry . | Kutujereha | Ref. rehegua. | Espec. |
Femoral Condilus Confuerte Chapa-III . | ![]() |
HA 4,5 hb 6,5. |
RP3G2KZC5HL rehegua. | 5h l rehegua . |
RP3G2KZC6HL rehegua. | 6h l rehegua . | |||
RP3G2KZC7HL rehegua . | 7h l rehegua . | |||
RP3G2KZC8HL rehegua . | 8h l rehegua . | |||
RP3G2KZC9HL rehegua . | 9h l rehegua . | |||
RP3G2KZC10HL rehegua . | 10h L rehegua . | |||
RP3G2KZC11HL rehegua . | 11h L rehegua . | |||
RP3G2KZC5h. | 5h r rehegua . | |||
RP3G2KZC6hr. | 6h r rehegua . | |||
RP3G2KZC7hr. | 7h r rehegua . | |||
RP3G2KZC8h. | 8h r rehegua . | |||
RP3G2KZC9h. | 9h r rehegua . | |||
RP3G2KZC10hr. | 10h r rehegua . | |||
RP3G2KZC11h. | 11h r rehegua . |
CNC Ñemboguata Ñe’ẽtekuaa rehegua . Pe tecnología de control numérico informático ojepuru ojejapo hag̃ua precisamente umi producto ortopédico. Ko proceso oreko umi característica alta precisión, alta eficiencia ha repetibilidad. Ikatu pya’e ojapo umi dispositivo médico personalizado oñemoĩva estructura anatómica humana rehe ha ome’ẽ umi paciente-pe umi plan de tratamiento personalizado. |
pulido de producto rehegua . Hembipotápe umi producto ortopédico pulido ha'e omohenda porãve haguã contacto implante ha tejido humano, omboguejy concentración estrés, ha omohenda porãve estabilidad a largo plazo implante. |
Inspección de Calidad rehegua . Pe prueba de propiedades mecánicas umi producto ortopédico rehegua ojejapo oñesimula haguã umi condición de estrés yvypóra hueso rehegua, ojeevalua haguã capacidad de carga ha durabilidad umi implante yvypóra retepýpe, ha oasegura seguridad ha confiabilidad. |
Paquete de Producto rehegua . Umi producto ortopédico oñembohyru peteî koty estéril-pe ikatu haguã oñeencapsula producto peteî ambiente ipotîva ha estéril-pe, ani haguã oî contaminación microbiana ha oasegura seguridad quirúrgica. |
Ko almacenamiento umi producto ortopédico oikotevëva estricto gestión in-and-out ha control de calidad oasegura haguã trazabilidad producto ha ohapejokóvo vencimiento térã envío equivocado. |
Koty muestra ojeporu oñeñongatu haguã, ojehechauka ha oñemboguata haguã opaichagua muestra producto ortopédico umi intercambio tecnología producto ha capacitación-pe guarã. |
1. Eporandu XC Medico Team-pe guarã Femoral Condylus Confuerno Chapa-III Catálogo de Productos rehegua.
2. Eiporavo nde producto Femoral Condylus Confuerte-III interesado.
3. Jajerure petet muestra ojehecha hagua placa de contrabajo Condylus femoral-III.
4.Ojapo peteî orden de XC Medico's Femoral Condilus Confuerte chapa-III.
5.Oiko peteĩ concesionario XC Medico-gua Femoral Condilus Confuerte Chapa-III.
1.Iporãve ojejogua umi precio femoral Condylus Confuerno chapa-III.
2.100% Pe Chapa de Confuerte Femoral de Calidad ijyvatevéva-III.
3. Ñeha’ã sa’ive oñembosako’íva.
4. Estabilidad precio rehegua upe periodo de acuerdo rehegua.
5. Suficiente Femoral Condilus Confuerte Chapa-III.
6. Evaluación pya’e ha ndahasýiva XC Medico’s Femoral Condylus Confuerzo Chapa-III rehegua.
7. Peteĩ marca ojehechakuaáva globalmente - XC Medico.
8. Tiempo de acceso pya’e XC Medico Ventas Equipo-pe.
9. Prueba de calidad adicional ojapova’ekue XC Medico Team.
10. Ejapo seguimiento nde orden XC Medico rehegua oñepyrũ guive opa peve.
Pe placa femoral Condilus Buttress-III ohechauka peteî solución avanzada tratamiento umi fractura cóndilo femoral rehegua. Umi fractura umi cóndilo femoral ha'e lesiones críticas ikatúva oreko tuicha impacto función articular rodilla ha movilidad general paciente. Pe Femoral Condilus Buttress Plate-III ojejapo ome'ê haguã fijación superior, oaseguráva alineación ha estabilidad hekoitépe proceso de curación jave. Ko guía integral ohesa'ÿijóta umi característica, ventaja ha aplicaciones clínicas chapa femoral Condilus Buttress-III, avei umi riesgo potencial ha tendencia mercado futuro.
Placa Femoral Condilus Buttress-III ha'e peteî implante ortopédico especialmente diseñado ojeporúva oestabiliza haguã fracturas cóndilo femoral, ha'éva umi área redondeada fémur oarticuláva tibia ha oforma parte articulación rodilla. Umi fractura ko región-pe ojehu jepi resultado trauma de alto impacto, ha'eháicha ho'a, accidente automovilístico térã lesiones relacionadas deportivas, ha oikotevëva intervención quirúrgica precisa ani haguã complicaciones ha'eháicha artritis postraumática térã malalineación.
Ko chapa ojejapo ome'ë haguã mokõive compresión ha estabilidad hueso fracturado, ohapejokóvo desplazamiento ambue proceso de curación jave. Oguereko peteĩ rol crucial omoĩjey haĝua función articular hekopete, omboguejývo hasy ha omoporãve haĝua pe paciente calidad de vida general.
Pe chapa oñecontornea anatómicamente ombojoaju haĝua precisamente pe cóndilo femoral forma, ominimisa haĝua tekotevẽha umi ajuste complejo cirugía aja.
Pe diseño contrafuerte pe chapa rehegua ome’ẽ peteĩ mecanismo de apoyo robusto oresisti umi fuerza compresión ha ojokóva pe cóndilo ani haĝua ho’a térã oñemoambue okuera jave.
Pe chapa oipuru umi tornillo de bloqueo oaseguráva peteĩ conexión mbarete pe chapa ha hueso apytépe. Ko mba'e ojehecharamovéva umi kangue osteoporótico-pe, omboguejy rupi riesgo ojeafloja térã ojeipe'a haguã tornillo.
Oĩ versión pe chapa rehegua ha’e radiolucente, opermitíva ojejapo peteĩ monitoreo ndahasýiva pe proceso de curación fractura rehegua umi rayos X rupive interferencia’ỹre pe material implante-gui.
Pe pláncha ojejapo ikatu hag̃uáicha oñembogue irritación umi tejidos blandos ijerére. Iestructura de bajo perfil oasegura ani haguã osê hetaiterei, omboguejývo riesgo complicaciones postoperatorias ha'eháicha dehiscencia herida térã inflamación tejido blando.
Ko chapa oikuave'ë opáichagua agujero tornillo, opermitíva umi cirujano oadapta fijación tipo de fractura específica ha calidad hueso.
Pe chapa diseño anatómico ha mecanismo de bloqueo ome'ë estabilidad iporãitereíva, ha'éva esencial ohapejokóvo malalineación térã no unión fase de curación jave.
Oñemotenondévo fijación fractura, umi paciente ikatu oñepyrü ejercicios de redacción de peso ha rehabilitación temprana, omboguejýva significativamente tiempo de recuperación ha riesgo de complicaciones ha'eháicha atrofia muscular térã rigidez articular.
Pe naturaleza de bajo perfil pe chapa rehegua omboguejy tekotevẽha ojejapo disección extensa umi tejidos blandos ijerére, oñeñongatu umi músculo, tendones ha ligamentos oĩva pe área de rodilla-pe.
Oñemoĩ jeývo alineación ha estabilidad cóndilo femoral rehegua, pe chapa oipytyvõ omantene haĝua pe funcionalidad a largo plazo pe articulación de rodilla, opermitíva umi paciente ohupyty jey movilidad ha oho jey pya’eve umi actividad normal-pe.
Oguerekóva fijación segura, chapa femoral Condilus Buttress-III omboguejy probabilidad complicaciones ha'eháicha falla implante, infección ha unión retardada.
Pe pláncha ningo ideprovéchoiterei oñepohano hag̃ua umi fractura comminuida, upépe oñembyai pe kangue heta hendápe. Pe diseño de confuerzo ome’ẽ compresión ha estabilización oñeikotevẽva omantene haĝua alineación cura jave.
Umi fractura oimehápe lado de tensión hueso-pe, chapa femoral Condilus contrafuerte-III oipytyvõ ohapejokóvo desplazamiento ambue ome'ëvo apoyo adicional umi fuerza externa rehe.
Umi fractura ohypýiva mokõive cóndilo femoral, ojehecha jepi trauma de alta energía-pe, ikatu ojeporu pe chapa ojeestabiliza haguã mokõive cóndilo, omoĩ jey haguã estabilidad rodilla-pe.
Umi paciente orekóva densidad ósea comprometida, mecanismo de bloqueo chapa oasegura fijación segura, jepénte umi hueso osteoporótico, orekóva propensión implante falla.
Pe Femoral Condilus Buttress Plate-III ojejapo omaneha haguã umi fractura ojepysóva espacio articular-pe, omboguejýva riesgo inestabilidad articular a largo plazo ha artritis omoî jeývo hendaitépe superficie articular.
Opaichagua procedimiento quirúrgico-icha, oî riesgo de infección, particularmente umi paciente orekóva sistema inmunológico comprometido térã práctica de higiene vai postoperatoriamente.
Sa’i sa’ípe, pe chapa térã tornillo ikatu ofalla, particularmente noñemboguejýiramo hekopete pe fractura térã ojejapóramo pe tensión mecánica hetaiterei pe junta rehe.
Pe cóndilo femoral oĩ umi nervio crítico ha tuguy rape ypýpe. Umi cirujano oreko va'erã cautela ani haguã oî daño inadvertido ko'ã estructura cirugía jave.
Jepémo pe placa ojejapo omokyre’ỹ haguã ósea ñemonguera hekopete, ikatu gueteri oiko pe no unión (fractura de la fractura a heal) térã maluro (poriahuvereko peteĩ posición hekope’ỹvape), especialmente umi fractura compleja-pe térã umi paciente orekóva capacidad de curación comprometida.
Oĩ hasýva ikatúva ohasa hasy térã incomodidad pe implante rendaguépe, ko’ýte pe chapa oike ramo en contacto umi tejidos blandos ijerére térã oĩramo inflamación pe sitio quirúrgico-pe.
Oñemotenondévo accidente de tránsito vial, lesiones deportivas ha ho'a, oñemohenda demanda umi dispositivo de fijación avanzada ha'eháicha Placa Femoral Condylus Buttress-III.
Población mundial oñemomba'eguasúvo, incidencia fractura, particularmente fracturas osteoporóticas, ojupíva ohóvo, omboguatáva tekotevê orekóva soluciones de fijación de fractura confiable, duradera.
Oñemotenondévo mejora ciencia de materiales ha diseño implante, ha'eháicha desarrollo de placas bioresorbibles térã mecanismos de bloqueo mejorado, omotenondéta innovación mercado de fijación fractura femoral-pe.
Pe movimiento cirugía mínimamente invasiva gotyo, ombohetavéta pe demanda de implantes de bajo perfil, altamente efectivo ikatúva ojeporu umi procedimiento menos invasivo-pe umi tiempo de recuperación pya’eve reheve.
Pe Femoral Condilus Buttress Plate-III ha'e peteî implante ipyahúva oikuave'êva solución efectiva oestabiliza haguã fracturas cóndilo femoral. Idiseño anatómicamente contorneado, mecanismo tornillo de bloqueo, ha construcción de bajo perfil, ome'ë fijación fractura omombaretéva ominimisávo interrupción tejido blando. Ko chapa omohenda porãve estabilidad, omokyre'ÿ rehabilitación pya'eve, ha omboguejy riesgo complicaciones ha'eháicha no unión, maldición ha falla implante. Opytáramo jepe umi riesgo quirúrgico, umi ventaja orekóva pe placa femoral Condilus Buttress-III ojapo chugui peteî tembiporu indispensable tratamiento umi fractura condilar femoral complejo-pe. Ojesarekóva tenonde gotyo, mercado ko'ãichagua dispositivo oñeha'ãrõ okakuaa, impulsado ojupívo umi káso trauma, población envejecimiento, ha umi avance oñemotenondéva tecnología implante ortopédico.
Recordatorio caliente: Ko artículo ha’e referencia-rãnte ha ndaikatúi omyengovia pe médico consejo profesional. Oiméramo reguereko mba’e porandu, eñe’ẽmi nde pohanohára asistente rehe.
Mba'eapopyre | Ta'angambyry . | Kutujereha | Ref. rehegua. | Espec. |
Femoral Condilus Confuerte Chapa-III . | ![]() |
HA 4,5 hb 6,5. |
RP3G2KZC5HL rehegua. | 5h l rehegua . |
RP3G2KZC6HL rehegua. | 6h l rehegua . | |||
RP3G2KZC7HL rehegua . | 7h l rehegua . | |||
RP3G2KZC8HL rehegua . | 8h l rehegua . | |||
RP3G2KZC9HL rehegua . | 9h l rehegua . | |||
RP3G2KZC10HL rehegua . | 10h L rehegua . | |||
RP3G2KZC11HL rehegua . | 11h L rehegua . | |||
RP3G2KZC5h. | 5h r rehegua . | |||
RP3G2KZC6hr. | 6h r rehegua . | |||
RP3G2KZC7hr. | 7h r rehegua . | |||
RP3G2KZC8h. | 8h r rehegua . | |||
RP3G2KZC9h. | 9h r rehegua . | |||
RP3G2KZC10hr. | 10h r rehegua . | |||
RP3G2KZC11h. | 11h r rehegua . |
CNC Ñemboguata Ñe’ẽtekuaa rehegua . Pe tecnología de control numérico informático ojepuru ojejapo hag̃ua precisamente umi producto ortopédico. Ko proceso oreko umi característica alta precisión, alta eficiencia ha repetibilidad. Ikatu pya’e ojapo umi dispositivo médico personalizado oñemoĩva estructura anatómica humana rehe ha ome’ẽ umi paciente-pe umi plan de tratamiento personalizado. |
pulido de producto rehegua . Hembipotápe umi producto ortopédico pulido ha'e omohenda porãve haguã contacto implante ha tejido humano, omboguejy concentración estrés, ha omohenda porãve estabilidad a largo plazo implante. |
Inspección de Calidad rehegua . Pe prueba de propiedades mecánicas umi producto ortopédico rehegua ojejapo oñesimula haguã umi condición de estrés yvypóra hueso rehegua, ojeevalua haguã capacidad de carga ha durabilidad umi implante yvypóra retepýpe, ha oasegura seguridad ha confiabilidad. |
Paquete de Producto rehegua . Umi producto ortopédico oñembohyru peteî koty estéril-pe ikatu haguã oñeencapsula producto peteî ambiente ipotîva ha estéril-pe, ani haguã oî contaminación microbiana ha oasegura seguridad quirúrgica. |
Ko almacenamiento umi producto ortopédico oikotevëva estricto gestión in-and-out ha control de calidad oasegura haguã trazabilidad producto ha ohapejokóvo vencimiento térã envío equivocado. |
Koty muestra ojeporu oñeñongatu haguã, ojehechauka ha oñemboguata haguã opaichagua muestra producto ortopédico umi intercambio tecnología producto ha capacitación-pe guarã. |
1. Eporandu XC Medico Team-pe guarã Femoral Condylus Confuerno Chapa-III Catálogo de Productos rehegua.
2. Eiporavo nde producto Femoral Condylus Confuerte-III interesado.
3. Jajerure petet muestra ojehecha hagua placa de contrabajo Condylus femoral-III.
4.Ojapo peteî orden de XC Medico's Femoral Condilus Confuerte chapa-III.
5.Oiko peteĩ concesionario XC Medico-gua Femoral Condilus Confuerte Chapa-III.
1.Iporãve ojejogua umi precio femoral Condylus Confuerno chapa-III.
2.100% Pe Chapa de Confuerte Femoral de Calidad ijyvatevéva-III.
3. Ñeha’ã sa’ive oñembosako’íva.
4. Estabilidad precio rehegua upe periodo de acuerdo rehegua.
5. Suficiente Femoral Condilus Confuerte Chapa-III.
6. Evaluación pya’e ha ndahasýiva XC Medico’s Femoral Condylus Confuerzo Chapa-III rehegua.
7. Peteĩ marca ojehechakuaáva globalmente - XC Medico.
8. Tiempo de acceso pya’e XC Medico Ventas Equipo-pe.
9. Prueba de calidad adicional ojapova’ekue XC Medico Team.
10. Ejapo seguimiento nde orden XC Medico rehegua oñepyrũ guive opa peve.
Pe placa femoral Condilus Buttress-III ohechauka peteî solución avanzada tratamiento umi fractura cóndilo femoral rehegua. Umi fractura umi cóndilo femoral ha'e lesiones críticas ikatúva oreko tuicha impacto función articular rodilla ha movilidad general paciente. Pe Femoral Condilus Buttress Plate-III ojejapo ome'ê haguã fijación superior, oaseguráva alineación ha estabilidad hekoitépe proceso de curación jave. Ko guía integral ohesa'ÿijóta umi característica, ventaja ha aplicaciones clínicas chapa femoral Condilus Buttress-III, avei umi riesgo potencial ha tendencia mercado futuro.
Placa Femoral Condilus Buttress-III ha'e peteî implante ortopédico especialmente diseñado ojeporúva oestabiliza haguã fracturas cóndilo femoral, ha'éva umi área redondeada fémur oarticuláva tibia ha oforma parte articulación rodilla. Umi fractura ko región-pe ojehu jepi resultado trauma de alto impacto, ha'eháicha ho'a, accidente automovilístico térã lesiones relacionadas deportivas, ha oikotevëva intervención quirúrgica precisa ani haguã complicaciones ha'eháicha artritis postraumática térã malalineación.
Ko chapa ojejapo ome'ë haguã mokõive compresión ha estabilidad hueso fracturado, ohapejokóvo desplazamiento ambue proceso de curación jave. Oguereko peteĩ rol crucial omoĩjey haĝua función articular hekopete, omboguejývo hasy ha omoporãve haĝua pe paciente calidad de vida general.
Pe chapa oñecontornea anatómicamente ombojoaju haĝua precisamente pe cóndilo femoral forma, ominimisa haĝua tekotevẽha umi ajuste complejo cirugía aja.
Pe diseño contrafuerte pe chapa rehegua ome’ẽ peteĩ mecanismo de apoyo robusto oresisti umi fuerza compresión ha ojokóva pe cóndilo ani haĝua ho’a térã oñemoambue okuera jave.
Pe chapa oipuru umi tornillo de bloqueo oaseguráva peteĩ conexión mbarete pe chapa ha hueso apytépe. Ko mba'e ojehecharamovéva umi kangue osteoporótico-pe, omboguejy rupi riesgo ojeafloja térã ojeipe'a haguã tornillo.
Oĩ versión pe chapa rehegua ha’e radiolucente, opermitíva ojejapo peteĩ monitoreo ndahasýiva pe proceso de curación fractura rehegua umi rayos X rupive interferencia’ỹre pe material implante-gui.
Pe pláncha ojejapo ikatu hag̃uáicha oñembogue irritación umi tejidos blandos ijerére. Iestructura de bajo perfil oasegura ani haguã osê hetaiterei, omboguejývo riesgo complicaciones postoperatorias ha'eháicha dehiscencia herida térã inflamación tejido blando.
Ko chapa oikuave'ë opáichagua agujero tornillo, opermitíva umi cirujano oadapta fijación tipo de fractura específica ha calidad hueso.
Pe chapa diseño anatómico ha mecanismo de bloqueo ome'ë estabilidad iporãitereíva, ha'éva esencial ohapejokóvo malalineación térã no unión fase de curación jave.
Oñemotenondévo fijación fractura, umi paciente ikatu oñepyrü ejercicios de redacción de peso ha rehabilitación temprana, omboguejýva significativamente tiempo de recuperación ha riesgo de complicaciones ha'eháicha atrofia muscular térã rigidez articular.
Pe naturaleza de bajo perfil pe chapa rehegua omboguejy tekotevẽha ojejapo disección extensa umi tejidos blandos ijerére, oñeñongatu umi músculo, tendones ha ligamentos oĩva pe área de rodilla-pe.
Oñemoĩ jeývo alineación ha estabilidad cóndilo femoral rehegua, pe chapa oipytyvõ omantene haĝua pe funcionalidad a largo plazo pe articulación de rodilla, opermitíva umi paciente ohupyty jey movilidad ha oho jey pya’eve umi actividad normal-pe.
Oguerekóva fijación segura, chapa femoral Condilus Buttress-III omboguejy probabilidad complicaciones ha'eháicha falla implante, infección ha unión retardada.
Pe pláncha ningo ideprovéchoiterei oñepohano hag̃ua umi fractura comminuida, upépe oñembyai pe kangue heta hendápe. Pe diseño de confuerzo ome’ẽ compresión ha estabilización oñeikotevẽva omantene haĝua alineación cura jave.
Umi fractura oimehápe lado de tensión hueso-pe, chapa femoral Condilus contrafuerte-III oipytyvõ ohapejokóvo desplazamiento ambue ome'ëvo apoyo adicional umi fuerza externa rehe.
Umi fractura ohypýiva mokõive cóndilo femoral, ojehecha jepi trauma de alta energía-pe, ikatu ojeporu pe chapa ojeestabiliza haguã mokõive cóndilo, omoĩ jey haguã estabilidad rodilla-pe.
Umi paciente orekóva densidad ósea comprometida, mecanismo de bloqueo chapa oasegura fijación segura, jepénte umi hueso osteoporótico, orekóva propensión implante falla.
Pe Femoral Condilus Buttress Plate-III ojejapo omaneha haguã umi fractura ojepysóva espacio articular-pe, omboguejýva riesgo inestabilidad articular a largo plazo ha artritis omoî jeývo hendaitépe superficie articular.
Opaichagua procedimiento quirúrgico-icha, oî riesgo de infección, particularmente umi paciente orekóva sistema inmunológico comprometido térã práctica de higiene vai postoperatoriamente.
Sa’i sa’ípe, pe chapa térã tornillo ikatu ofalla, particularmente noñemboguejýiramo hekopete pe fractura térã ojejapóramo pe tensión mecánica hetaiterei pe junta rehe.
Pe cóndilo femoral oĩ umi nervio crítico ha tuguy rape ypýpe. Umi cirujano oreko va'erã cautela ani haguã oî daño inadvertido ko'ã estructura cirugía jave.
Jepémo pe placa ojejapo omokyre’ỹ haguã ósea ñemonguera hekopete, ikatu gueteri oiko pe no unión (fractura de la fractura a heal) térã maluro (poriahuvereko peteĩ posición hekope’ỹvape), especialmente umi fractura compleja-pe térã umi paciente orekóva capacidad de curación comprometida.
Oĩ hasýva ikatúva ohasa hasy térã incomodidad pe implante rendaguépe, ko’ýte pe chapa oike ramo en contacto umi tejidos blandos ijerére térã oĩramo inflamación pe sitio quirúrgico-pe.
Oñemotenondévo accidente de tránsito vial, lesiones deportivas ha ho'a, oñemohenda demanda umi dispositivo de fijación avanzada ha'eháicha Placa Femoral Condylus Buttress-III.
Población mundial oñemomba'eguasúvo, incidencia fractura, particularmente fracturas osteoporóticas, ojupíva ohóvo, omboguatáva tekotevê orekóva soluciones de fijación de fractura confiable, duradera.
Oñemotenondévo mejora ciencia de materiales ha diseño implante, ha'eháicha desarrollo de placas bioresorbibles térã mecanismos de bloqueo mejorado, omotenondéta innovación mercado de fijación fractura femoral-pe.
Pe movimiento cirugía mínimamente invasiva gotyo, ombohetavéta pe demanda de implantes de bajo perfil, altamente efectivo ikatúva ojeporu umi procedimiento menos invasivo-pe umi tiempo de recuperación pya’eve reheve.
Pe Femoral Condilus Buttress Plate-III ha'e peteî implante ipyahúva oikuave'êva solución efectiva oestabiliza haguã fracturas cóndilo femoral. Idiseño anatómicamente contorneado, mecanismo tornillo de bloqueo, ha construcción de bajo perfil, ome'ë fijación fractura omombaretéva ominimisávo interrupción tejido blando. Ko chapa omohenda porãve estabilidad, omokyre'ÿ rehabilitación pya'eve, ha omboguejy riesgo complicaciones ha'eháicha no unión, maldición ha falla implante. Opytáramo jepe umi riesgo quirúrgico, umi ventaja orekóva pe placa femoral Condilus Buttress-III ojapo chugui peteî tembiporu indispensable tratamiento umi fractura condilar femoral complejo-pe. Ojesarekóva tenonde gotyo, mercado ko'ãichagua dispositivo oñeha'ãrõ okakuaa, impulsado ojupívo umi káso trauma, población envejecimiento, ha umi avance oñemotenondéva tecnología implante ortopédico.
Recordatorio caliente: Ko artículo ha’e referencia-rãnte ha ndaikatúi omyengovia pe médico consejo profesional. Oiméramo reguereko mba’e porandu, eñe’ẽmi nde pohanohára asistente rehe.
Jekuaaverã