GX301004 a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Hming | AIH. | Milem | Hlawm khat | |||
Tibial leh femur fracture ring fixator a awm bawk. | GX301001 a ni. | ![]() |
Ruahman | |||
Lower limb hian pawn lam fixator a ti sei a . | GX301003 a ni. | ![]() |
Ruahman | |||
Tibial leh femur fracture ring fixator-l . | GX301004 a ni. | ![]() |
Ruahman | |||
Pawn lam elbow joint fixator . | GX301005 a ni. | ![]() |
Ruahman | |||
Tibia leh femur fixation a awm a, a khelh dan tur pawh a hriat theih. | GX301006 a ni. | ![]() |
Ruahman | |||
Taylor pawn lam fixator a ni. | GX301007 a ni. | ![]() |
Ruahman | |||
Knee joint fixator a awm bawk. | GX301008 a ni. | ![]() |
Ruahman | |||
Ankle joint fixator a awm bawk. | GX301009 a ni. | ![]() |
Ruahman |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah tibial leh femur fracture ring fixator-l product catalogue dil rawh.
2. I ngaihven tibial leh femur fracture ring fixator-l product thlang rawh.
3. Tibial leh femur fracture ring fixator-l test turin sample dil rawh.
4.A order chu XC Medico-a tibial leh femur fracture ring fixator-l.
5.XC Medico-a tibial leh femur fracture ring fixator-l a hralhtu ni rawh.
1.tibial leh femur fracture ring fixator-l lei man tha zawk.
2.100% Tibial leh femur fracture ring fixator-l quality sang ber a ni.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. Tibial leh femur fracture ring fixator-l a tling.
6. XC Medico-a tibial leh femur fracture ring fixator-l te awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Orthopaedic innovation hian complex fractures enkawlna chu a tidanglam a, ruh stabilization leh healing-ah precision leh efficacy a pe a ni. Tibial leh femur fracture ring fixator-L hi tibia leh femur-a hliam na tak tak leh deformities enkawlna atana siam, external fixation device cutting-edge a ni. He guide hian a features, benefits, applications, leh hmalam hun atana a hmalam hun tur te ngun taka zirchian a ni a, orthopedic surgeons, medical students, leh healthcare researchers te tan a ni.
Tibial leh femur fracture ring fixator-L hi pawn lam atanga ruh tliakte tihngheh nan leh controlled process hmanga ruh siam thar awlsamna atana hman thin a ni. Tibia leh femur-a complex, open, leh multi-fragmented fracture-te tan bik a engineer a, deformity correction leh limb lengthening atan pawh a bik takin engineer a ni bawk.
Rod, wire, leh screw hmanga inzawm, circular emaw semi-circular ring hmanga siam a ni a, he fixator hian multidirectional stability a tichiang a ni. A modular design hian damloin taksa peng hrang hrang leh ruh tliak a mamawh dan azirin customization a siam thei a ni. He model-a 'l' variant hian a locking mechanism hmasawn tak a kawk a, biomechanical property a ti mawi bawk.
Fixation stability a ti tha a, screw loosening a ti tlem bawk.
Fractures te chu complexity leh anatomical location hrang hrang neiin a awm thei.
High-strength titanium emaw stainless steel emaw hmanga design a ni a, a chhe thei lo turin a rit lutuk belh lovin.
Plane tam takah stabilization a pe a, alignment leh healing outcome tha zawk a siam thei.
Modular components hmang hian surgeon te chuan damlo mamawh ang zela construct chu an siam thei a ni.
Radiolucent components hian X-ray emaw CT scan hmangin fracture alignment leh healing dik taka enfiah a ti awlsam a ni.
Acute fracture leh chronic deformities pahnih enkawlna atan a tangkai hle.
Internal fixation method nena khaikhin chuan soft tissue chhiatna a tihziaawm.
Pawn lam dahna chuan nerve leh thisen kalna kawng hrang hrang hnuaia awm structure-te nena inzawmna a ti tlem a ni.
Surgical intervention dang tih belh ngai lovin postoperative modification a phalsak.
Fracture hmuna controlled stress vawng rengin osteogenesis a tichak.
Pawn lam nature hian deep infection a ti tlem a, a bik takin open fractures ah chuan.
Exposure leh contamination avanga internal fixation contraindicated a nih chuan a tha ber.
Multi-fragmented fractures a stabilize a, chutih rualin anatomical alignment a vawng reng bawk.
Fracture inpumkhat thei lote damna awlsam zawka siam theihna tura puihna mamawh a pe.
Bridges gaps leh bone regeneration a tichak a, defect lian tak tak a awm bawk.
Zawi zawiin inthlak danglamna hmangin ruhro misaligned emaw, dik lo taka rotated emaw a siam ha hin.
Pin emaw wire emaw entry point-a natna kai lo tur venna atan hian enkawlna leh thianghlimna mumal tak neih a pawimawh hle.
Device hmuh theih leh bulky nature hian rilru leh taksa lama harsatna a thlen thei a ni.
Suboptimal adjustment emaw damlo zawm loh emaw chuan union emaw un-union emaw a tlai thei.
Hun rei tak hman chuan a chhehvel tissue te chu a ti na emaw, a ti na thei emaw a ni thei.
A tlem hle nachungin, wire breakage emaw frame instability emaw ang chi issue a awm thei.
Kawngpuiah lirthei accident leh infiamna lama hliam a pun zel avangin advanced fixation device mamawhna a sang hle.
Kum upa lam mipui pung zel chuan osteoporotic fracture leh non-union case tam zawk a thlen thin.
Smart fixator te chu automated adjustment leh real-time monitoring capabilities te nena inzawmkhawm hian device functionality a tichak a ni.
Limb tih sei, deformity correction, leh reconstructive surgery-a pawn lam fixator-te pawm zau zawk.
Ram thang mek zinga healthcare investment sang zel hian market thanna tur kawng thar a siam mek a ni.
Tibial leh femur fracture ring fixator-L hi state-of-the-art device a ni a, tibia leh femur-a fracture leh deformities complex tak tak te sutkian nana siam a ni. A feature hmasawn tak tak, multiplanar fixation, enhanced locking mechanisms, leh modular design te nen chuan stability leh adaptability tluk loh a pe a ni. A hmanna nena inzawm hlauhawmna a awm laiin, taima taka surgical planning leh patient compliance chuan a rah chhuah tha ber a siam a ni. Innovative orthopedic solutions mamawhna a san chhoh zel chuan tibial leh femur fracture ring fixator-L hi tunlai fracture management-ah chuan hmanraw pawimawh tak a la ni reng dawn a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | AIH. | Milem | Hlawm khat | |||
Tibial leh femur fracture ring fixator a awm bawk. | GX301001 a ni. | ![]() |
Ruahman | |||
Lower limb hian pawn lam fixator a ti sei a . | GX301003 a ni. | ![]() |
Ruahman | |||
Tibial leh femur fracture ring fixator-l . | GX301004 a ni. | ![]() |
Ruahman | |||
Pawn lam elbow joint fixator . | GX301005 a ni. | ![]() |
Ruahman | |||
Tibia leh femur fixation a awm a, a khelh dan tur pawh a hriat theih. | GX301006 a ni. | ![]() |
Ruahman | |||
Taylor pawn lam fixator a ni. | GX301007 a ni. | ![]() |
Ruahman | |||
Knee joint fixator a awm bawk. | GX301008 a ni. | ![]() |
Ruahman | |||
Ankle joint fixator a awm bawk. | GX301009 a ni. | ![]() |
Ruahman |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah tibial leh femur fracture ring fixator-l product catalogue dil rawh.
2. I ngaihven tibial leh femur fracture ring fixator-l product thlang rawh.
3. Tibial leh femur fracture ring fixator-l test turin sample dil rawh.
4.A order chu XC Medico-a tibial leh femur fracture ring fixator-l.
5.XC Medico-a tibial leh femur fracture ring fixator-l a hralhtu ni rawh.
1.tibial leh femur fracture ring fixator-l lei man tha zawk.
2.100% Tibial leh femur fracture ring fixator-l quality sang ber a ni.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. Tibial leh femur fracture ring fixator-l a tling.
6. XC Medico-a tibial leh femur fracture ring fixator-l te awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Orthopaedic innovation hian complex fractures enkawlna chu a tidanglam a, ruh stabilization leh healing-ah precision leh efficacy a pe a ni. Tibial leh femur fracture ring fixator-L hi tibia leh femur-a hliam na tak tak leh deformities enkawlna atana siam, external fixation device cutting-edge a ni. He guide hian a features, benefits, applications, leh hmalam hun atana a hmalam hun tur te ngun taka zirchian a ni a, orthopedic surgeons, medical students, leh healthcare researchers te tan a ni.
Tibial leh femur fracture ring fixator-L hi pawn lam atanga ruh tliakte tihngheh nan leh controlled process hmanga ruh siam thar awlsamna atana hman thin a ni. Tibia leh femur-a complex, open, leh multi-fragmented fracture-te tan bik a engineer a, deformity correction leh limb lengthening atan pawh a bik takin engineer a ni bawk.
Rod, wire, leh screw hmanga inzawm, circular emaw semi-circular ring hmanga siam a ni a, he fixator hian multidirectional stability a tichiang a ni. A modular design hian damloin taksa peng hrang hrang leh ruh tliak a mamawh dan azirin customization a siam thei a ni. He model-a 'l' variant hian a locking mechanism hmasawn tak a kawk a, biomechanical property a ti mawi bawk.
Fixation stability a ti tha a, screw loosening a ti tlem bawk.
Fractures te chu complexity leh anatomical location hrang hrang neiin a awm thei.
High-strength titanium emaw stainless steel emaw hmanga design a ni a, a chhe thei lo turin a rit lutuk belh lovin.
Plane tam takah stabilization a pe a, alignment leh healing outcome tha zawk a siam thei.
Modular components hmang hian surgeon te chuan damlo mamawh ang zela construct chu an siam thei a ni.
Radiolucent components hian X-ray emaw CT scan hmangin fracture alignment leh healing dik taka enfiah a ti awlsam a ni.
Acute fracture leh chronic deformities pahnih enkawlna atan a tangkai hle.
Internal fixation method nena khaikhin chuan soft tissue chhiatna a tihziaawm.
Pawn lam dahna chuan nerve leh thisen kalna kawng hrang hrang hnuaia awm structure-te nena inzawmna a ti tlem a ni.
Surgical intervention dang tih belh ngai lovin postoperative modification a phalsak.
Fracture hmuna controlled stress vawng rengin osteogenesis a tichak.
Pawn lam nature hian deep infection a ti tlem a, a bik takin open fractures ah chuan.
Exposure leh contamination avanga internal fixation contraindicated a nih chuan a tha ber.
Multi-fragmented fractures a stabilize a, chutih rualin anatomical alignment a vawng reng bawk.
Fracture inpumkhat thei lote damna awlsam zawka siam theihna tura puihna mamawh a pe.
Bridges gaps leh bone regeneration a tichak a, defect lian tak tak a awm bawk.
Zawi zawiin inthlak danglamna hmangin ruhro misaligned emaw, dik lo taka rotated emaw a siam ha hin.
Pin emaw wire emaw entry point-a natna kai lo tur venna atan hian enkawlna leh thianghlimna mumal tak neih a pawimawh hle.
Device hmuh theih leh bulky nature hian rilru leh taksa lama harsatna a thlen thei a ni.
Suboptimal adjustment emaw damlo zawm loh emaw chuan union emaw un-union emaw a tlai thei.
Hun rei tak hman chuan a chhehvel tissue te chu a ti na emaw, a ti na thei emaw a ni thei.
A tlem hle nachungin, wire breakage emaw frame instability emaw ang chi issue a awm thei.
Kawngpuiah lirthei accident leh infiamna lama hliam a pun zel avangin advanced fixation device mamawhna a sang hle.
Kum upa lam mipui pung zel chuan osteoporotic fracture leh non-union case tam zawk a thlen thin.
Smart fixator te chu automated adjustment leh real-time monitoring capabilities te nena inzawmkhawm hian device functionality a tichak a ni.
Limb tih sei, deformity correction, leh reconstructive surgery-a pawn lam fixator-te pawm zau zawk.
Ram thang mek zinga healthcare investment sang zel hian market thanna tur kawng thar a siam mek a ni.
Tibial leh femur fracture ring fixator-L hi state-of-the-art device a ni a, tibia leh femur-a fracture leh deformities complex tak tak te sutkian nana siam a ni. A feature hmasawn tak tak, multiplanar fixation, enhanced locking mechanisms, leh modular design te nen chuan stability leh adaptability tluk loh a pe a ni. A hmanna nena inzawm hlauhawmna a awm laiin, taima taka surgical planning leh patient compliance chuan a rah chhuah tha ber a siam a ni. Innovative orthopedic solutions mamawhna a san chhoh zel chuan tibial leh femur fracture ring fixator-L hi tunlai fracture management-ah chuan hmanraw pawimawh tak a la ni reng dawn a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp