OLIF hian lumbar intervertebral disc space-ah oblique lateral retroperitoneal approach a pe a, chutih rualin psoas muscle, posterior musculature leh neural structure-te tihbuai a ti tlem hle. He procedure hian disc san zawng siamthatna, sagittal alignment, indirect decompression leh lumbar interbody fusion rintlak tak a pui a ni.
L2–L5 leh L5–S1 case thlan chhuah te a ni
OLIF approach hian oblique lateral corridor kaltlangin indirect decompression leh interbody fusion a pe a, chutih rualin posterior spinal structures te chu a humhim a, a chhehvel muscle leh soft tissue te tihbuai a tihtlem bawk.
Psoas muscle kaltlangin direct-a kal lovin retroperitoneal corridor kaltlangin lumbar disc space-ah luh theihna a pe.
Footprint lian tak nei OLIF cage hian disc san zawng, segmental alignment leh foraminal dimensions siamthatna a pui a ni.
Lordotic cage configurations hian lumbar alignment a siam tha leh a, controlled anterior column reconstruction a pe bawk.
OLIF cage hi open posterior fixation, cement-augmented MIS fixation emaw percutaneous pedicle screw emaw hmanga inzawm theih a ni.
OLIF interbody cage hi lumbar condition, surgical approach, ruh quality leh fixation strength mamawh angin posterior stabilization system tam tak nen paired theih a ni.
Lumbar degenerative diseases, instability, deformity leh spondylolisthesis case thlan bikte tan OLIF cage leh 6.0 mm pedicle screw-rod system inzawmkhawmna rigid posterior fixation configuration.
Enhanced screw anchoring mamawh damlo thlan bikte tan OLIF cage leh MIS 5.5 cement-augmented fenestrated screws inzawmkhawmna, minimally invasive configuration.
Percutaneous posterior fixation option, OLIF cage stabilization pui thei tura duan a ni a, chutih rualin posterior muscle leh soft-tissue tihbuai lohna tur a tihtlem bawk.
6.0 mm pedicle screw-rod system hian OLIF siam tharna atan rigid posterior stabilization a pe a, cage stability, spinal alignment leh multi-level lumbar fixation te a thlawp a ni.
Fixation procedure thlan biktea controlled bone cement delivery atana siam fenestrated pedicle screw.
Screw dahna leh cement thawn chhuahna hnathawh dan tur, minimally invasive instruments matching.
MIS 5.5 cement-augmented fenestrated screw system hian minimally invasive posterior stabilization a support a, ruh quality tlahniam damlo thlan bikteah screw anchoring a tichak thei bawk.
5.5 MIS Spinal System II hian percutaneous pedicle screw fixation leh OLIF cage a hmang dun a, lumbar reconstruction a pui a, chutih rualin posterior muscle leh soft-tissue disruption a tihziaawm bawk.
Percutaneous pedicle screw solution chu a hnunglam lumbar fixation invasive tlem ber atan siam a ni.
Percutaneous screw dahna tur, rod luhtirna leh final construct fixation atana hmanraw bikte.
A hnuaia workflow hian OLIF surgical sequence tlangpui a tarlang a ni. Final approach, implant thlan dan leh posterior fixation strategy te chu surgeon chuan mimal case a zirin a ruat tur a ni.
OLIF hian coordinated interbody, access, leh a tam zawkah chuan supplemental fixation theihna a mamawh a, hei hian supplier evaluation chu cage geometry chauh aiin a zau zawk a ni. Multi-approach lumbar portfolio siamtu distributor te chuan hmahruaitu an tehkhin thei lumbar fusion implant supplier te an ni . TLIF, PLIF, ALIF, OLIF, posterior fixation, leh matched instrumentation hrang hranga
Minimally invasive oblique lateral approach hmangin indirect decompression leh interbody fusion a pe a, chutih rualin posterior spinal structures te chu a humhim bawk.
Damlo chu lateral decubitus position-ah dah a ni. Target disc level thleng tur chuan minimally invasive oblique lateral retroperitoneal approach an ti a.
Disc natna chu lakchhuah a ni a, cartilaginous endplate te chu uluk taka buatsaih a ni a, endplate integrity vawng reng chungin fusion bed dik tak siam a ni.
Graft material thlan chhuah hmanga khat OLIF cage chu disc space-ah dahin disc san zawng a siam ṭha leh a, sagittal alignment a thlawp a, anterior column support a pe bawk.
Surgical plan angin open emaw minimally invasive pedicle screw-rod system hman a ni a, hei hian supplemental stability a pe a, spinal alignment a vawng reng thei bawk.
Fluoroscopic imaging hmangin cage position, implant stability leh spinal alignment te chu final wound closure hmain an finfiah thin.
XC Medico hian OLIF cage, posterior fixation system, cement-augmented screw leh matching surgical instrument te chu coordinated lumbar fusion solution pakhat angin a configure thei a ni.
Cage, pedicle screw leh matching instrument te chu coordinated product solution pakhat chhunga supply a ni.
Open, MIS leh cement-augmented fixation option hrang hrangte chu procedural requirement angin buatsaih a ni.
I mamawh cage size leh fixation configuration te thawn la, coordinated implant leh instrument pricing atan.
Product catalog, specification leh distributor presentation material te a awm bawk.
Implant configuration thlan bikte, packaging leh branding service hrang hrangte sawiho theih a ni.
OLIF cage size mamawh te, lumbar level te, posterior fixation option leh instrument configuration te min hrilh teh. Kan team chuan i distributor, hospital emaw OEM project atan implant leh instrument quotation kimchang tak kan buatsaih ang.
Inbepawp