Inphochhuak
Damlo chu standard midline posterior cervical incision ang bawkin prone position-ah dah a ni. Occipital bone, atlas hnunglam arch, leh articular mass leh cervical segment arch fuse ngai te chu pholang rawh.
Occipitocervical, upper cervical leh lower cervical stabilization hmanna tur titanium posterior spinal fixation system a ni.
Titanium a ni
3.5mm fixed rod a ni
Screw-rod hmanga hnunglam fixation
He system hi occipital fixation method hrang hrang, low-profile 3.5mm rod design, clinical habit hrang hrang atana optional instruments, leh flexible construct adjustment atana polyaxial screw structure hmanga present a ni.
Surgeon duh dan leh case mamawh dan azirin occipital fixation method hrang hrang thlan theih a ni.
He system hian 3.5mm diameter fixed rod a hmang a, lower-profile posterior fixation construct a hmang bawk.
Clinical habit hrang hrang leh surgical workflow duhzawngte thlawp turin optional tools a awm bawk.
Low-profile design hian construct chhehvela soft tissue awmte stimulation tihtlem nan a pui a ni.
Negative-angle thread design hian screw arm a zau loh nan a pui a ni.
Special-structure polyaxial screw design hian unidirectional motion sang ber 55° thleng a support thei a ni.
He section hi professional-facing product summary atan hmang rawh. Thumal hman dan chu tihchhuah hmain local IFU pawm tawh nen thlirlet hmasak tur a ni.
Occipitocervical position leh upper cervical instability te a awm bawk.
Lower cervical spine degeneration emaw, traumatic hnua thil danglam emaw a awm thei.
Lower cervical spine a nghet lo.
Front fusion cage hi a hnunglam cage chhungah stabilise leh tihchak a ngai a ni.
Procedure content hi visual card anga dah a nih avangin original PDF spread aiin online-ah a chhiar tha zawk. Thuchhuah hunah he section chunga professional-use notice hi vawng reng ang che.
Damlo chu standard midline posterior cervical incision ang bawkin prone position-ah dah a ni. Occipital bone, atlas hnunglam arch, leh articular mass leh cervical segment arch fuse ngai te chu pholang rawh.
Entry point leh entry angle an hriat hnuah cortical bone chu open drill hmangin an drill a, hole chu an ti lian a ni.
Screw entry point chu side mass lai takah chhung lam hawiin leh chunglam 2mm anga sawi a ni. Entry angle chu pawn lam 20°-25° leh head end lam 30°-40°-a tilt a ni a, a kianga articular surface nen a inmil hle.
Lower cervical C3-C7 screws dah dik hian vertebral artery leh nerve risk a tih tlem theih nan a pui a, chutih rualin screw sei ber leh fixation tha ber a pe bawk.
Lower cervical C3-C7: screw entry point chu side block pawn lam kil chhungah 2-5mm a ni a, upper facet articular surface base hnuaiah 2-3mm a ni. Entry angle chu coronal plane chhungah 30°-45° a ni a, sagittal plane chu upper endplate nen parallel a ni.
Upper cervical C1-C2: C1 lateral mass screw entry hi atlas hnunglam tubercle midpoint bulah 18-20mm vel a ni tih sawi a ni a, depth control chu 28mm vel a ni. C2 pedicle screw entry hi lateral mass lai takah vertical line lai takah tarlan a ni a, a thuk zawng chu a tlangpuiin 24-26mm vel a ni.
Heng screw entry description te hi IFU atanga professional reference content a ni a, surgical situation bik a innghat a ni.
Drill bit leh guide hmangin drill la, drill tur thuk zawng chu teh rawh. Guide chu a thuk zawng tihtlem nan a inmil scale-ah siamrem rawh.
Drilling speed leh depth chu measured data angin khauh takin control rawh. Vertebral cortex a luh tam lutuk loh nan leh peripheral nerve emaw vascular tissue emaw a tihchhiat loh nan a thuk tur ruat lawk a thlen veleh drilling kha titawp nghal rawh.
Hole siam zawh hnuah drill bit chu la chhuakin pilot hole chhunga ruh chhe awmte chu tifai rawh.
Screw path thuk zawng chu depth gauge hmangin teh a ni a, a sei zawng tur screw thlan a ni.
Ruh a khauh chuan tapping hman theih a ni.
He section hian implant insertion page te chu web layout chiang takah a chantir a, procedural card hrang hrang leh a kaihhnawih images te a awm bawk.
Screwdriver hmangin screw implant rawh. Screwdriver hexagon chu screw chhungah dah vek la, chutah chuan locking sleeve-ah screw hmangin screw chu implant rawh.
Screw dahna leh dahna tur atana pui turin screw-holding forceps hmang ang che. Screw la awmte chu a hnungzuiin identical procedural template zawm chungin dah rawh.
Damlo taksa peng hrang hrang (anatomical curvature) a zirin rod sei zawng tur dik tak thlang rawh. Rod chu rod movement angin cut leh prebent a ni a, chu chu spine sagittal curve a awm theih nan a ni.
Material integrity vawng reng turin bending tam lutuk leh tih nawn fo loh tur a ni. Rod hi dah hmain a chhiat leh chhiat loh uluk taka enfiah tur a ni.
Rod-holding forceps hmangin rod chu chelh la, implanted screw-a U-shaped slot-ah dah rawh.
Preload wrench hmangin screw plug chu U ang maia threaded slot-ah dah la. A tirah chuan set screw pakhat chu hexagonal wrench hmangin tighten la, rod chu provisionally secure rawh.
Spinal rod chu pedicle screw-a U-shaped slot-ah dah a nih hnuah reduction leh contouring maneuver tih theih a ni.
Compression: compression forceps te chu pedicle screw inhnaih takah dah la, inward closing force hmangin vertebrae pahnih chu rod linkage hmangin hnaih zawkah hruai rawh.
Distraction: screw inhnaih tak pahnih inkarah distractor dah la, rod zawhin distract la, intervertebral height hloh chu la let lehin compressed nerve roots te chu chhuah tir rawh.
Rotation: rod rotator hmangin rod chu man la, screw U-slot chhungah spinal rod chu rotate la, sagittal curvature siamrem la, screw opening te chu align rawh.
Anti-rotation sleeve hmangin screw plug chu screw U-shaped slot-ah dah la, hexagonal wrench hmangin provisionally tighten rawh.
Occipital leh cervical screw zawng zawng chu a chung atanga a hnuai thlengin lock vek la, a tul angin transverse connector implant rawh.
Alignment duh leh implant position i confirm hnuah torque-limiting wrench tarlan hmangin set screw zawng zawng final tightening ti rawh.
Hliam khar hmain component zawng zawng chu him taka lock a nih leh construct a stable em tih enfiah hmasa phawt ang che.
Note: torque-limiting wrench hi optional accessory a ni a, a hranin hralh a ni.
Alignment, implant position, component locking leh construct stability te chu khar hmain confirm hmasa phawt ang che.
A hnuaia table-te hian PDF product information chu responsive website table-ah an chantir a, chu chuan browsing leh index awlsam zawkin a siam thei a ni.
| REF | Diameter | a sei zawng |
|---|---|---|
| CPPS3512 a ni | Φ3.5 a ni | 12mm a ni |
| CPPS3514 a ni | Φ3.5 a ni | 14mm a ni |
| CPPS3516 a ni | Φ3.5 a ni | 16mm a ni |
| CPPS3518 a ni | Φ3.5 a ni | 18mm a ni |
| CPPS3520 a ni | Φ3.5 a ni | 20mm a ni |
| CPPS3522 a ni | Φ3.5 a ni | 22mm a ni |
| CPPS3524 a ni | Φ3.5 a ni | 24mm a ni |
| CPPS3526 a ni | Φ3.5 a ni | 26mm a ni |
| CPPS3528 a ni | Φ3.5 a ni | 28mm a ni |
| CPPS3530 a ni | Φ3.5 a ni | 30mm a ni |
| CPPS4010 a ni | Φ4.0 a ni | 10mm a ni |
| CPPS4012 a ni | Φ4.0 a ni | 12mm a ni |
| CPPS4014 a ni | Φ4.0 a ni | 14mm a ni |
| CPPS4016 a ni | Φ4.0 a ni | 16mm a ni |
| CPPS4018 a ni | Φ4.0 a ni | 18mm a ni |
| CPPS4020 a ni | Φ4.0 a ni | 20mm a ni |
| CPPS4022 a ni | Φ4.0 a ni | 22mm a ni |
| CPPS4024 a ni | Φ4.0 a ni | 24mm a ni |
| CPPS4026 a ni | Φ4.0 a ni | 26mm a ni |
| CPPS4028 a ni | Φ4.0 a ni | 28mm a ni |
| CPPS4030 a ni | Φ4.0 a ni | 30mm a ni |
| REF | chungchang sawifiahna |
|---|---|
| RJHHL35 a ni | 35mm a ni |
| RJHHL40 a ni | 40mm a ni |
| RJHHL45 a ni | 45mm a ni |
| REF | A sei zawng |
|---|---|
| TB35100 a ni | 100mm a ni |
| TB35200 a ni | 200mm a ni |
| REF | chungchang sawifiahna |
|---|---|
| RJHZG chuan a ti a | / |
Instrument set information hi PDF table original atang khan balanced, web-friendly configuration layout ah dah a ni.
Instrument listed tin hi original instrument set table angin quantity 1 nen supply a ni.
Product specification, instrument set information, catalog details, leh posterior spinal fixation solutions atana distributor support te hriat duh chuan XC Medico zawhfiah theih a ni.
I mamawh specification, target market, registration mamawh, leh estimated order volume te share rawh. Kan team hian product configuration dik tak confirm turin kan pui ang.
Min rawn biak theih reng eInbepawp