RJSG
XcMedico
1 tk (72 tundi kohaletoimetamine)
Õlavarre
Titaansulam või roostevaba teras
CE/ISO: 9001/ISO13485.ETC
Eritellimusel valmistatud 15-päevane kohaletoimetamine (välja arvatud saatmisaja)
FedEx. Dhl.tnt.ems.etc
Saadavus: | |
---|---|
Kogus: | |
Tooted | Pilt | Konkreetsed mudelid | Spetsifikatsioon |
Õlavarre multi Lukustus intramedullaarselt Küüned |
![]() |
RJSG18160R | 8,0 × 160R |
RJSG18160L | 8,0 × 160L | ||
RJSG19160R | 9,0 × 160R | ||
RJSG19160L | 9,0 × 160L | ||
RJSG17180R | 7,0 × 180 | ||
RJSG17195R | 7,0 × 195 | ||
RJSG17210R | 7,0 × 210 | ||
RJSG17225R | 7,0 × 225 | ||
RJSG17240R | 7,0 × 240 | ||
RJSG17255R | 7,0 × 255 | ||
RJSG18180R | 8,0 × 180 | ||
RJSG18195R | 8,0 × 195 | ||
RJSG18210R | 8,0 × 210 | ||
RJSG18225R | 8,0 × 225 | ||
RJSG18240R | 8,0 × 240 | ||
RJSG18255R | 8,0 × 255 | ||
RJSG17180L | 7,0 × 180 | ||
RJSG17195L | 7,0 × 195 | ||
RJSG17210L | 7,0 × 210 | ||
RJSG17225L | 7,0 × 225 | ||
RJSG17240L | 7,0 × 240 | ||
RJSG17255L | 7,0 × 255 | ||
RJSG18180L | 8,0 × 180 | ||
RJSG18195L | 8,0 × 195 | ||
RJSG18210L | 8,0 × 210 | ||
RJSG18225L | 8,0 × 225 | ||
RJSG18240L | 8,0 × 240 | ||
RJSG18255L | 8,0 × 255 | ||
Kruvimutter | ![]() |
Rjsg1wm0 | 0 |
Rjsg1wm2 | 2 | ||
Rjsg1wm5 | 5 | ||
RJSG1WM10 | 10 | ||
RJSG1WM15 | 15 | ||
Lukustuskruvi-i | ![]() |
RJSG1ld4530 | 4,5 × 30 |
RJSG1LD4532 | 4,5 × 32 | ||
RJSG1LD4534 | 4,5 × 34 | ||
RJSG1LD4536 | 4,5 × 36 | ||
RJSG1LD4538 | 4,5 × 38 | ||
RJSG1LD4540 | 4,5 × 40 | ||
RJSG1LD4542 | 4,5 × 42 | ||
RJSG1LD4544 | 4,5 × 44 | ||
RJSG1LD4546 | 4,5 × 46 | ||
RJSG1LD4548 | 4,5 × 48 | ||
RJSG1LD4550 | 4,5 × 50 | ||
RJSG1LD4552 | 4,5 × 52 | ||
RJSG1LD4554 | 4,5 × 54 | ||
RJSG1LD4556 | 4,5 × 56 | ||
RJSG1LD4558 | 4,5 × 58 | ||
Rjsg1ld4560 | 4,5 × 60 | ||
Lukustuskruvi-ii | ![]() |
RJSG1LD3526 | 3,5 × 26 |
RJSG1LD3528 | 3,5 × 28 | ||
RJSG1LD3530 | 3,5 × 30 | ||
RJSG1LD3532 | 3,5 × 32 | ||
RJSG1LD3534 | 3,5 × 34 | ||
RJSG1LD3536 | 3,5 × 36 | ||
RJSG1LD3538 | 3,5 × 38 | ||
RJSG1LD3540 | 3,5 × 40 | ||
RJSG1LD3542 | 3,5 × 42 | ||
RJSG1LD3544 | 3,5 × 44 | ||
RJSG1LD3546 | 3,5 × 46 | ||
RJSG1LD3548 | 3,5 × 48 | ||
RJSG1LD3550 | 3,5 × 50 | ||
Lukustuskruvi-iii | ![]() |
RJSG1LD4018 | 4,0 × 18 |
RJSG1LD4020 | 4,0 × 20 | ||
RJSG1LD4022 | 4,0 × 22 | ||
RJSG1LD4024 | 4,0 × 24 | ||
RJSG1LD4026 | 4,0 × 26 | ||
RJSG1LD4028 | 4,0 × 28 | ||
RJSG1LD4030 | 4,0 × 30 | ||
RJSG1LD4032 | 4,0 × 32 | ||
RJSG1LD4034 | 4,0 × 34 | ||
RJSG1LD4036 | 4,0 × 36 | ||
RJSG1LD4038 | 4,0 × 38 | ||
RJSG1LD4040 | 4,0 × 40 | ||
RJSG1LD4042 | 4,0 × 42 | ||
RJSG1LD4044 | 4,0 × 44 | ||
RJSG1LD4046 | 4,0 × 46 | ||
RJSG1LD4048 | 4,0 × 48 | ||
RJSG1LD4050 | 4,0 × 50 | ||
RJSG1LD4052 | 4,0 × 52 | ||
RJSG1LD4054 | 4,0 × 54 | ||
RJSG1LD4056 | 4,0 × 56 | ||
RJSG1LD4058 | 4,0 × 58 | ||
RJSG1LD4060 | 4,0 × 60 |
1.Straight küünte kujundus keskse sisestuspunkti jaoks.
|
CNC esialgne töötlemine Arvuti numbrilist juhtimistehnoloogiat kasutatakse ortopeediliste toodete täpseks töötlemiseks. Sellel protsessil on kõrge täpsuse, suure efektiivsuse ja korratavuse omadused. See võib kiiresti toota kohandatud meditsiiniseadmeid, mis vastavad inimese anatoomilisele struktuurile ja pakkuda patsientidele isikupärastatud raviplaane. |
Toote poleerimine Ortopeediliste toodete poleerimise eesmärk on parandada implantaadi ja inimkudede vahelist kontakti, vähendada stressi kontsentratsiooni ja parandada implantaadi pikaajalist stabiilsust. |
Kvaliteedikontroll Ortopeediliste toodete mehaaniliste omaduste test on loodud simuleerimiseks inimese luude pingetingimustest, hindamiseks inimkehas implantaatide koormuse kandmisvõimet ja vastupidavust ning tagama nende turvalisuse ja usaldusväärsuse. |
Tootepakett Ortopeedilised tooted on pakendatud steriilsesse ruumi, et tagada toode puhtasse ja steriilsesse keskkonda, et vältida mikroobide saastumist ja tagada kirurgiline ohutus. |
Ortopeediliste toodete ladustamine nõuab ranget sisse- ja väljajuhtimis- ja kvaliteedikontrolli, et tagada toodete jälgitavus ja vältida aegumist või valet saatmist. |
Prooviruumi kasutatakse erinevate ortopeediliste toodete proovide hoidmiseks, kuvamiseks ja haldamiseks tootetehnoloogia vahetamiseks ja koolituseks. |
1. Küsige XC Medico meeskonnalt mitme lukuga õlavarre intramedullaarse küünte toodete kataloogi.
2. Valige oma huvitatud mitmelukk-õlavarre intramedullaarne küünte toode.
3. Paluge proovi testida mitmelukilise õlavarre intramedullaarse küünte kvaliteedi testimiseks.
4. Tehke XC Medico mitmelukilise õlavarre intramedullaarse küünte tellimus.
5.Become XC Medico mitmelukilise õlavarre intramedullaarse küünte edasimüüja.
1. Paremad ostuhinnad mitmelukiliste õlavarraste intramedullaarsete küünte paremad.
2,100% kõrgeima kvaliteediga mitmelukiga õlavarre intramedullaarsed küüned.
3. Vähem tellimispüüdlusi.
4. kokkuleppeperioodi hinnastabiilsus.
5. Piisav mitmelukk-õlavarre intramedullaarne küünte.
6. XC Medico mitme lukuga õlavarre intramedullaarse küünte kiire ja lihtne hindamine.
7. Globaalselt tunnustatud bränd - XC Medico.
8. Kiire juurdepääsu aeg XC Medico müügimeeskonnale.
9. XC Medico meeskonna täiendav kvaliteeditest.
10. Jälgige oma XC Medico tellimust algusest lõpuni.
Hurvese multi-lock intramedullaarne küünte on kirurgiline implantaat, mis on loodud õlavarre õlavarre luumurdude stabiliseerimiseks. See on pikk, sihvakas varras, mis on valmistatud titaanist või roostevabast terasest, mis on sisestatud õlavarre medullaarsesse õõnsusse. Küün kinnitatakse oma kohale lukustuskruvidega, mis on sisestatud luu ja küünte ise.
Küün sisaldab mitut proksimaalset ja distaalset lukustuspunkti, mis tagavad turvalise fikseerimise. See funktsioon võimaldab paindlikkust mitmesuguste luumurdude, sealhulgas põiki, kaldus ja moodustatud luumurdude käitlemisel.
Ergonoomilise disainiga, mis hõlbustab sisestamise ja positsioneerimise lihtsust, vähendab küünte kirurgilist aega ja võimaldab täpset joondamist minimaalsete reguleerimisega.
Kõrgekvaliteedilisest titaanist ehitatud küünte on kerge, korrosioonikindla ja biosoblik, mis on valmistatud biosobitavatest materjalidest, mis on keha hästi sallitud, vähendades postoperatiivsete komplikatsioonide riski ja tagades pikaealisuse.
Vähendab kudede ärrituse ja nakatumise riski.
Mitme lukustumise süsteem tagab suurenenud stabiilsuse, vähendades pöörlemis ebastabiilsuse riski ja tagades turvalise luumurdude fikseerimise, eriti kasulikud murdude korral.
Selle minimaalselt invasiivne olemus vähendab pehmete kudede häireid, mille tulemuseks on vähem operatsioonijärgne valu, madalam nakkuserisk ja patsientide kiirem taastumine.
Patsiendid taastavad liikuvuse sageli küünte koormuse jagamise võimaluste tõttu, mis toetavad varajast kaalu kandmist, mis on hädavajalik pikaajalise immobiliseerimisega seotud komplikatsioonide vähendamiseks.
Selle ühilduvus erinevate luumurdude ja humaraalsete anatoomiatega muudab selle traumakirurgide jaoks mitmekülgseks valikuks, tagades paljude juhtumite suure edukuse.
Sealhulgas üksikasjalik haiguslugu, füüsiline läbivaatus, kujutise uurimine (röntgenikiirgus, CT jne), et hinnata luumurdude tüüpi ja astet ning ümbritseva pehmete kudede seisundit.
Kujutise andmete kohaselt koostatakse üksikasjalik kirurgiline plaan, sealhulgas lähenemisviisi valimine, intramedullaarne küünte mudel, lukustuskruvide arv ja asukoht jne.
Tavaliselt kasutatakse brachial plexus plokki või üldne anesteesiat.
See on kõige sagedamini kasutatav lähenemisviis, mis on läbi sisselõigete eesmise deltoidse lihase, proksimaalne õlavorm paljastatakse.
Mõnede spetsiaalsete luumurdude korral võib olla vajalik ka muid lähenemisviise, näiteks subkorakoidne lähenemisviis.
C-Armi röntgenikiirguse masina juhendamisel vähendatakse luumurdunud luufragmendid anatoomilisse asendisse manipuleerimise või instrumentide abil.
Keerukate luumurdude korral võib väikese sisselõike kaudu vajada avatud vähendamist.
Medullaarset õõnsust suurendatakse järk -järgult, kasutades medullaarset õõnsust laiendaja, et mahutada intramedullaarse küünte läbimõõt.
C-Armi röntgenikiirguse masina juhendamisel sisestatakse juhtnõel medullaarsesse õõnsusse või suuremat tuberosity kuni luumurdu distaalse otsa.
Sisestage intramedullaarne küünte piki juhtnõela, kuni see jõuab etteantud asendisse.
C-armi röntgenikiirguse masina juhendamisel puuritakse auk humaraalse peaga või suuremat tuberosity läbi spetsiaalse puurimiskarruka ja seejärel sisestatakse lukustuskruvi.
Puurige luumurru distaalses otsas auk ja sisestage lukustuskruvi.
Kruvi tugevdamine: lukustuskruvide arvu saab suurendada vastavalt luumurru tüübile ja stabiilsusele.
Pärast põhjalikku hemostaasi suletakse pehmete kude kihiga.
Vajadusel asetage drenaažitoru.
Sibage haav steriilse kastmega.
Pärast operatsiooni tuleb kahjustatud jäseme fikseerida tavaliselt kolmnurksele sidemele või kasutada õla traksidega.
Õlaliigese funktsionaalseid harjutusi alustatakse liigese jäikuse vältimiseks varakult pärast operatsiooni.
Nakkuse vältimiseks antakse antibiootikumid pärast operatsiooni.
Regulaarne järelkontroll luumurdude paranemise jälgimiseks.
Kuigi haruldane, võib küünte migratsioon tekkida, kui mitte kindlalt lukustatud, seetõttu peavad kirurgid kontrollima, kas kõik lukustuspunktid on operatsiooni ajal korralikult hõivatud.
Operatsioonijärgsete infektsioonide vältimiseks tuleb rangelt järgida õigeid steriliseerimisprotokolle, eriti arvestades protseduuri minimaalselt invasiivset olemust.
Kontrollitud jõu kasutamine sisestamise ajal aitab vältida luude kildumist või kanali liigset laienemist, mis võib põhjustada komplikatsioone või hilinenud paranemist.
MSPVA-sid ja muid valuvaigijaid kasutatakse operatsioonijärgse valu haldamiseks tavaliselt koos vajadusega täiendavate ravimeetoditega patsiendi mugavuse tagamiseks.
Lihase tugevuse, paindlikkuse ja liikumisvahemiku taastamiseks võib pärast 4-6 nädalat kasutusele võetud füsioteraapiat kasutusele võtta, aidates patsiendil taastada Normaalne ARM-i funktsioon.
Patsientidel on soovitatav jälgida sisselõike kohas nakatumise tunnuseid, näiteks punetust või turset ning jälgida regulaarseid kontrollimisi.
Luu paranemise jälgimiseks ja küünte püsimiseks õiges asendis on regulaarne pildistamine, mis on eduka taastumise jaoks ülioluline.
Normaalse aktiivsuse juurde naasmise ajaskaala varieerub sõltuvalt konkreetsest luumurdust, individuaalse paranemise kiirusest ja kirurgilisest protseduurist. Esialgses paranemisfaasis on oluline järgida oma kirurgi nõuandeid ja vältida liigset füüsilist aktiivsust. Kui luu paraneb, saate järk -järgult suurendada oma aktiivsuse taset, sealhulgas õrna liikumisharjutuste ja tugevdamisharjutuste.
HUMRUSE MULTI LOCKI INGEMEMEMEMEMEMULLARY NAYSI TUREVUSE TURE MÕNEKS MEIE MÄRKUSEKS, MIS ARUKOHTA ORTOROPEDIA TEHNOLOOGIA EDENDUSED, kasvav nõudlus minimaalselt invasiivsete lahenduste järele ja laienemist arenevatel turgudel.
Õhumusega mitmelukilised intramedullaarsed küüned on efektiivsed kirurgilised implantaadid õlavarruste stabiliseerimiseks. Need pakuvad mitmeid eeliseid, sealhulgas minimaalne invasiivsus, kiirem paranemine ja paremad funktsionaalsed tulemused. Siiski on oluline mõista selle protseduuriga seotud võimalikke riske ja tüsistusi. Järgides õigeid kirurgilisi tehnikaid ja operatsioonijärgset ravi, saavad patsiendid saavutada optimaalse paranemise ja taastumise.
Soe meeldetuletus: see artikkel on mõeldud ainult ja ei saa asendada arsti ametialast nõu. Kui teil on küsimusi, pöörduge oma arsti poole.
Tooted | Pilt | Konkreetsed mudelid | Spetsifikatsioon |
Õlavarre multi Lukustus intramedullaarselt Küüned |
![]() |
RJSG18160R | 8,0 × 160R |
RJSG18160L | 8,0 × 160L | ||
RJSG19160R | 9,0 × 160R | ||
RJSG19160L | 9,0 × 160L | ||
RJSG17180R | 7,0 × 180 | ||
RJSG17195R | 7,0 × 195 | ||
RJSG17210R | 7,0 × 210 | ||
RJSG17225R | 7,0 × 225 | ||
RJSG17240R | 7,0 × 240 | ||
RJSG17255R | 7,0 × 255 | ||
RJSG18180R | 8,0 × 180 | ||
RJSG18195R | 8,0 × 195 | ||
RJSG18210R | 8,0 × 210 | ||
RJSG18225R | 8,0 × 225 | ||
RJSG18240R | 8,0 × 240 | ||
RJSG18255R | 8,0 × 255 | ||
RJSG17180L | 7,0 × 180 | ||
RJSG17195L | 7,0 × 195 | ||
RJSG17210L | 7,0 × 210 | ||
RJSG17225L | 7,0 × 225 | ||
RJSG17240L | 7,0 × 240 | ||
RJSG17255L | 7,0 × 255 | ||
RJSG18180L | 8,0 × 180 | ||
RJSG18195L | 8,0 × 195 | ||
RJSG18210L | 8,0 × 210 | ||
RJSG18225L | 8,0 × 225 | ||
RJSG18240L | 8,0 × 240 | ||
RJSG18255L | 8,0 × 255 | ||
Kruvimutter | ![]() |
Rjsg1wm0 | 0 |
Rjsg1wm2 | 2 | ||
Rjsg1wm5 | 5 | ||
RJSG1WM10 | 10 | ||
RJSG1WM15 | 15 | ||
Lukustuskruvi-i | ![]() |
RJSG1ld4530 | 4,5 × 30 |
RJSG1LD4532 | 4,5 × 32 | ||
RJSG1LD4534 | 4,5 × 34 | ||
RJSG1LD4536 | 4,5 × 36 | ||
RJSG1LD4538 | 4,5 × 38 | ||
RJSG1LD4540 | 4,5 × 40 | ||
RJSG1LD4542 | 4,5 × 42 | ||
RJSG1LD4544 | 4,5 × 44 | ||
RJSG1LD4546 | 4,5 × 46 | ||
RJSG1LD4548 | 4,5 × 48 | ||
RJSG1LD4550 | 4,5 × 50 | ||
RJSG1LD4552 | 4,5 × 52 | ||
RJSG1LD4554 | 4,5 × 54 | ||
RJSG1LD4556 | 4,5 × 56 | ||
RJSG1LD4558 | 4,5 × 58 | ||
Rjsg1ld4560 | 4,5 × 60 | ||
Lukustuskruvi-ii | ![]() |
RJSG1LD3526 | 3,5 × 26 |
RJSG1LD3528 | 3,5 × 28 | ||
RJSG1LD3530 | 3,5 × 30 | ||
RJSG1LD3532 | 3,5 × 32 | ||
RJSG1LD3534 | 3,5 × 34 | ||
RJSG1LD3536 | 3,5 × 36 | ||
RJSG1LD3538 | 3,5 × 38 | ||
RJSG1LD3540 | 3,5 × 40 | ||
RJSG1LD3542 | 3,5 × 42 | ||
RJSG1LD3544 | 3,5 × 44 | ||
RJSG1LD3546 | 3,5 × 46 | ||
RJSG1LD3548 | 3,5 × 48 | ||
RJSG1LD3550 | 3,5 × 50 | ||
Lukustuskruvi-iii | ![]() |
RJSG1LD4018 | 4,0 × 18 |
RJSG1LD4020 | 4,0 × 20 | ||
RJSG1LD4022 | 4,0 × 22 | ||
RJSG1LD4024 | 4,0 × 24 | ||
RJSG1LD4026 | 4,0 × 26 | ||
RJSG1LD4028 | 4,0 × 28 | ||
RJSG1LD4030 | 4,0 × 30 | ||
RJSG1LD4032 | 4,0 × 32 | ||
RJSG1LD4034 | 4,0 × 34 | ||
RJSG1LD4036 | 4,0 × 36 | ||
RJSG1LD4038 | 4,0 × 38 | ||
RJSG1LD4040 | 4,0 × 40 | ||
RJSG1LD4042 | 4,0 × 42 | ||
RJSG1LD4044 | 4,0 × 44 | ||
RJSG1LD4046 | 4,0 × 46 | ||
RJSG1LD4048 | 4,0 × 48 | ||
RJSG1LD4050 | 4,0 × 50 | ||
RJSG1LD4052 | 4,0 × 52 | ||
RJSG1LD4054 | 4,0 × 54 | ||
RJSG1LD4056 | 4,0 × 56 | ||
RJSG1LD4058 | 4,0 × 58 | ||
RJSG1LD4060 | 4,0 × 60 |
1.Straight küünte kujundus keskse sisestuspunkti jaoks.
|
CNC esialgne töötlemine Arvuti numbrilist juhtimistehnoloogiat kasutatakse ortopeediliste toodete täpseks töötlemiseks. Sellel protsessil on kõrge täpsuse, suure efektiivsuse ja korratavuse omadused. See võib kiiresti toota kohandatud meditsiiniseadmeid, mis vastavad inimese anatoomilisele struktuurile ja pakkuda patsientidele isikupärastatud raviplaane. |
Toote poleerimine Ortopeediliste toodete poleerimise eesmärk on parandada implantaadi ja inimkudede vahelist kontakti, vähendada stressi kontsentratsiooni ja parandada implantaadi pikaajalist stabiilsust. |
Kvaliteedikontroll Ortopeediliste toodete mehaaniliste omaduste test on loodud simuleerimiseks inimese luude pingetingimustest, hindamiseks inimkehas implantaatide koormuse kandmisvõimet ja vastupidavust ning tagama nende turvalisuse ja usaldusväärsuse. |
Tootepakett Ortopeedilised tooted on pakendatud steriilsesse ruumi, et tagada toode puhtasse ja steriilsesse keskkonda, et vältida mikroobide saastumist ja tagada kirurgiline ohutus. |
Ortopeediliste toodete ladustamine nõuab ranget sisse- ja väljajuhtimis- ja kvaliteedikontrolli, et tagada toodete jälgitavus ja vältida aegumist või valet saatmist. |
Prooviruumi kasutatakse erinevate ortopeediliste toodete proovide hoidmiseks, kuvamiseks ja haldamiseks tootetehnoloogia vahetamiseks ja koolituseks. |
1. Küsige XC Medico meeskonnalt mitme lukuga õlavarre intramedullaarse küünte toodete kataloogi.
2. Valige oma huvitatud mitmelukk-õlavarre intramedullaarne küünte toode.
3. Paluge proovi testida mitmelukilise õlavarre intramedullaarse küünte kvaliteedi testimiseks.
4. Tehke XC Medico mitmelukilise õlavarre intramedullaarse küünte tellimus.
5.Become XC Medico mitmelukilise õlavarre intramedullaarse küünte edasimüüja.
1. Paremad ostuhinnad mitmelukiliste õlavarraste intramedullaarsete küünte paremad.
2,100% kõrgeima kvaliteediga mitmelukiga õlavarre intramedullaarsed küüned.
3. Vähem tellimispüüdlusi.
4. kokkuleppeperioodi hinnastabiilsus.
5. Piisav mitmelukk-õlavarre intramedullaarne küünte.
6. XC Medico mitme lukuga õlavarre intramedullaarse küünte kiire ja lihtne hindamine.
7. Globaalselt tunnustatud bränd - XC Medico.
8. Kiire juurdepääsu aeg XC Medico müügimeeskonnale.
9. XC Medico meeskonna täiendav kvaliteeditest.
10. Jälgige oma XC Medico tellimust algusest lõpuni.
Hurvese multi-lock intramedullaarne küünte on kirurgiline implantaat, mis on loodud õlavarre õlavarre luumurdude stabiliseerimiseks. See on pikk, sihvakas varras, mis on valmistatud titaanist või roostevabast terasest, mis on sisestatud õlavarre medullaarsesse õõnsusse. Küün kinnitatakse oma kohale lukustuskruvidega, mis on sisestatud luu ja küünte ise.
Küün sisaldab mitut proksimaalset ja distaalset lukustuspunkti, mis tagavad turvalise fikseerimise. See funktsioon võimaldab paindlikkust mitmesuguste luumurdude, sealhulgas põiki, kaldus ja moodustatud luumurdude käitlemisel.
Ergonoomilise disainiga, mis hõlbustab sisestamise ja positsioneerimise lihtsust, vähendab küünte kirurgilist aega ja võimaldab täpset joondamist minimaalsete reguleerimisega.
Kõrgekvaliteedilisest titaanist ehitatud küünte on kerge, korrosioonikindla ja biosoblik, mis on valmistatud biosobitavatest materjalidest, mis on keha hästi sallitud, vähendades postoperatiivsete komplikatsioonide riski ja tagades pikaealisuse.
Vähendab kudede ärrituse ja nakatumise riski.
Mitme lukustumise süsteem tagab suurenenud stabiilsuse, vähendades pöörlemis ebastabiilsuse riski ja tagades turvalise luumurdude fikseerimise, eriti kasulikud murdude korral.
Selle minimaalselt invasiivne olemus vähendab pehmete kudede häireid, mille tulemuseks on vähem operatsioonijärgne valu, madalam nakkuserisk ja patsientide kiirem taastumine.
Patsiendid taastavad liikuvuse sageli küünte koormuse jagamise võimaluste tõttu, mis toetavad varajast kaalu kandmist, mis on hädavajalik pikaajalise immobiliseerimisega seotud komplikatsioonide vähendamiseks.
Selle ühilduvus erinevate luumurdude ja humaraalsete anatoomiatega muudab selle traumakirurgide jaoks mitmekülgseks valikuks, tagades paljude juhtumite suure edukuse.
Sealhulgas üksikasjalik haiguslugu, füüsiline läbivaatus, kujutise uurimine (röntgenikiirgus, CT jne), et hinnata luumurdude tüüpi ja astet ning ümbritseva pehmete kudede seisundit.
Kujutise andmete kohaselt koostatakse üksikasjalik kirurgiline plaan, sealhulgas lähenemisviisi valimine, intramedullaarne küünte mudel, lukustuskruvide arv ja asukoht jne.
Tavaliselt kasutatakse brachial plexus plokki või üldne anesteesiat.
See on kõige sagedamini kasutatav lähenemisviis, mis on läbi sisselõigete eesmise deltoidse lihase, proksimaalne õlavorm paljastatakse.
Mõnede spetsiaalsete luumurdude korral võib olla vajalik ka muid lähenemisviise, näiteks subkorakoidne lähenemisviis.
C-Armi röntgenikiirguse masina juhendamisel vähendatakse luumurdunud luufragmendid anatoomilisse asendisse manipuleerimise või instrumentide abil.
Keerukate luumurdude korral võib väikese sisselõike kaudu vajada avatud vähendamist.
Medullaarset õõnsust suurendatakse järk -järgult, kasutades medullaarset õõnsust laiendaja, et mahutada intramedullaarse küünte läbimõõt.
C-Armi röntgenikiirguse masina juhendamisel sisestatakse juhtnõel medullaarsesse õõnsusse või suuremat tuberosity kuni luumurdu distaalse otsa.
Sisestage intramedullaarne küünte piki juhtnõela, kuni see jõuab etteantud asendisse.
C-armi röntgenikiirguse masina juhendamisel puuritakse auk humaraalse peaga või suuremat tuberosity läbi spetsiaalse puurimiskarruka ja seejärel sisestatakse lukustuskruvi.
Puurige luumurru distaalses otsas auk ja sisestage lukustuskruvi.
Kruvi tugevdamine: lukustuskruvide arvu saab suurendada vastavalt luumurru tüübile ja stabiilsusele.
Pärast põhjalikku hemostaasi suletakse pehmete kude kihiga.
Vajadusel asetage drenaažitoru.
Sibage haav steriilse kastmega.
Pärast operatsiooni tuleb kahjustatud jäseme fikseerida tavaliselt kolmnurksele sidemele või kasutada õla traksidega.
Õlaliigese funktsionaalseid harjutusi alustatakse liigese jäikuse vältimiseks varakult pärast operatsiooni.
Nakkuse vältimiseks antakse antibiootikumid pärast operatsiooni.
Regulaarne järelkontroll luumurdude paranemise jälgimiseks.
Kuigi haruldane, võib küünte migratsioon tekkida, kui mitte kindlalt lukustatud, seetõttu peavad kirurgid kontrollima, kas kõik lukustuspunktid on operatsiooni ajal korralikult hõivatud.
Operatsioonijärgsete infektsioonide vältimiseks tuleb rangelt järgida õigeid steriliseerimisprotokolle, eriti arvestades protseduuri minimaalselt invasiivset olemust.
Kontrollitud jõu kasutamine sisestamise ajal aitab vältida luude kildumist või kanali liigset laienemist, mis võib põhjustada komplikatsioone või hilinenud paranemist.
MSPVA-sid ja muid valuvaigijaid kasutatakse operatsioonijärgse valu haldamiseks tavaliselt koos vajadusega täiendavate ravimeetoditega patsiendi mugavuse tagamiseks.
Lihase tugevuse, paindlikkuse ja liikumisvahemiku taastamiseks võib pärast 4-6 nädalat kasutusele võetud füsioteraapiat kasutusele võtta, aidates patsiendil taastada Normaalne ARM-i funktsioon.
Patsientidel on soovitatav jälgida sisselõike kohas nakatumise tunnuseid, näiteks punetust või turset ning jälgida regulaarseid kontrollimisi.
Luu paranemise jälgimiseks ja küünte püsimiseks õiges asendis on regulaarne pildistamine, mis on eduka taastumise jaoks ülioluline.
Normaalse aktiivsuse juurde naasmise ajaskaala varieerub sõltuvalt konkreetsest luumurdust, individuaalse paranemise kiirusest ja kirurgilisest protseduurist. Esialgses paranemisfaasis on oluline järgida oma kirurgi nõuandeid ja vältida liigset füüsilist aktiivsust. Kui luu paraneb, saate järk -järgult suurendada oma aktiivsuse taset, sealhulgas õrna liikumisharjutuste ja tugevdamisharjutuste.
HUMRUSE MULTI LOCKI INGEMEMEMEMEMEMULLARY NAYSI TUREVUSE TURE MÕNEKS MEIE MÄRKUSEKS, MIS ARUKOHTA ORTOROPEDIA TEHNOLOOGIA EDENDUSED, kasvav nõudlus minimaalselt invasiivsete lahenduste järele ja laienemist arenevatel turgudel.
Õhumusega mitmelukilised intramedullaarsed küüned on efektiivsed kirurgilised implantaadid õlavarruste stabiliseerimiseks. Need pakuvad mitmeid eeliseid, sealhulgas minimaalne invasiivsus, kiirem paranemine ja paremad funktsionaalsed tulemused. Siiski on oluline mõista selle protseduuriga seotud võimalikke riske ja tüsistusi. Järgides õigeid kirurgilisi tehnikaid ja operatsioonijärgset ravi, saavad patsiendid saavutada optimaalse paranemise ja taastumise.
Soe meeldetuletus: see artikkel on mõeldud ainult ja ei saa asendada arsti ametialast nõu. Kui teil on küsimusi, pöörduge oma arsti poole.