rpykl a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Hming | Milem | Item no. | Specification 100 a ni. |
1.5mm orbital plate chi hrang hrang(thickness:0.6mm) | ![]() |
RPYKL1506 a ni. | l a ni. |
RPYKR1506 a ni. | R 10 a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico team te chu 1.5mm orbital plate product catalog ah zawt rawh.
2. I duh ber 1.5mm orbital plate product thlang rawh.
3. 1.5mm orbital plate test tur sample dil rawh.
4.XC Medico 1.5mm orbital plate order siam rawh.
5.XC Medico-a 1.5mm orbital plate-a dealer ni rawh.
1.1.5mm orbital plate a lei man tha zawk.
2.100% Quality sang ber 1.5mm orbital plate a ni.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. 1.5mm orbital plate tling tak a ni.
6. XC Medico-a 1.5mm orbital plate hman dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
1.5mm orbital plate hi orbital fracture enkawlna atana hman thin, a bik takin orbital floor leh bangte nghawng thei tur, orthopedic implant pawimawh tak a ni. A hna ber chu mit socket (orbit) anatomical structure siam that leh a ni a, hei hi visual function leh facial aesthetics pahnih humhalh nan a pawimawh hle. He guide kimchang tak hian 1.5mm orbital plate-a a features, advantages, treatment applications, risks, leh market outlook te a zirchiang a, chu chuan medical professionals te chu surgical outcome hlawhtling tak tak pui turin hriatna chipchiar tak pek a tum a ni.
1.5mm orbital plate hi orbital fracture siamthatna atana hman thin titanium implant te tak te, siam dik tak a ni. Orbital fracture hi thil thleng rapthlak tak tak, blunt force hliam, motor accident, emaw sports-related trauma te avanga lo awm a ni fo thin. Heng ruh tliakte hian harsatna a thlen thei a, chu chu double vision, restricted eye movement, leh facial deformities te a ni. 1.5mm orbital plate hi orbital structure integrity siam that leh, ruh tliakte thlawpna leh mit socket vel a awmna hmun tihngheh nan siam a ni.
Plate hi titanium atanga siam a ni a, biocompatible material a ni a, a chakna, a chhe thei lo, a chhe thei lo tih hriat a ni. 1.5mm thickness hian plate chu minimally invasive a nih theih nan a enkawl a, hei hian incisions te zawk leh recovery time tihtlem hmangin enkawlna tha tak a pe thei a ni. Implant’s anatomical shape chu orbital cavity natural curvature nen a inmil a, damlo outcome fit leh tihchangtlunna dik tak a pe a ni.
Plate hi orbital floor leh wall-a natural curvature mirror tura siam a ni. Hei hian fit dik zawk leh ruh structure hmasa ber siamthatna tha zawk a siamsak a ni.
A chakna, a rit lo hle a, biocompatibility a neih avangin hriat lar a ni a, Titanium hi mit chhehvela hmun nalh takah dah implant siamna atana hman tur thil tha ber a ni. Infection hlauhawmna a ti tlem a, hun rei tak chhung dinhmun nghet tak a siamsak bawk.
Titanium hi radiolucent a ni a, chu chu x-ray emaw CT scan emaw ang chi imaging technique a tibuai lo tihna a ni. Hei hi damna enfiah leh operation hnua harsatna awm thei hmuhchhuahna atan a pawimawh hle.
Plate hi orbital region nena inmil turin pre-formed a ni a, operation neih chhunga implant siam dan tur atana hun leh tha mamawh a tlem phah a ni. Mahse, plate hian a tul angin adjustment tenau te pawh a awm theih nan flexibility level a nei reng a ni.
Plate-ah hian implant chu a chhehvel ruh thlenga nghet taka dah theihna tur screw holes a awm a ni. Hei hian stability tihpun a pe a, dam chhunga implant displacement awm theihna a ti tlem bawk.
A profile thin avangin plate hian minimally invasive surgery a siam thei a, hei hian soft tissue trauma a ti tlem a, recovery process a ti chak bawk.
Orbital floor emaw wall emaw siam that hian implant hian mit socket natural shape leh function a humhim thei a, chu chuan mit lama harsatna leh hmel lanna a ti tlem thei a ni.
1.5mm orbital plate pre-shaped nature hian intraoperative bending emaw customization emaw mamawhna a ti tlem a, chu chuan surgery hun chhung a ti tawi a ni.
Minimally invasive approach, plate design dik tak nen chuan recovery time rang zawk, postoperative pain tlem zawk, leh normal activities-a kir leh thuai a thlen thei a ni.
Titanium’s corrosion resistance hian plate hian hun kal zelah a chakna leh a dinhmun a vawng reng thei a, chu chuan implant a chhiat theihna leh revision surgery a mamawhna a ti tlem a ni.
Implant’s design leh a hman dan tha tak tak hman hian natna kai theihna a ti tlem a, chu chu infection, plate migration, emaw tissue chhiatna te a ni.
Heng ruh tliakte hi thil bengchheng tak tak (blunt) in orbit a tihchhiat chuan a lo awm a, chu chuan orbital floor emaw wall emaw a ti chhe thin. 1.5mm orbital plate hian blowout fractures enkawlna kawngah a thawk tha hle a, a chhan chu ruh tliakte chu a ti nghet a, a chhehvela thil awmte, ruh tliakna hmuna awm thei, taksa ruh emaw thau emaw a tihchhiat belh loh nan a pui a ni.
Chungte chu orbit-a ruh perimeter-a break awmte a ni. Chutiang hunah chuan 1.5mm plate hian orbital floor-ah structural reinforcement a pe a, orbital architecture pumpui a thlawp bawk.
Thil henkhatah chuan orbital floor leh bang pahnih nghawng thei tam tak a awm a. 1.5mm orbital plate hi surgical implant dang nen a inzawm thei a, chu chuan complex fractures te chu a hmachhawn thei a, orbital structure chu a siam thar leh vek theih bawk.
Orbital floor chu a tam thei ang bera a inthlak chuan plate hian ruh fragment te chu a stabilize thei a, displacement a veng thei a, damna dik tak a fuih thei bawk.
Implant hmanga surgical procedure dang ang bawkin, natna kai theihna a awm bawk. Hetiang hlauhawmna tihziaawmna tur hian sterilization technique dik tak, antibiotic prophylaxis, leh post-operative care te hi a pawimawh hle.
Plate chu dik lo taka dah emaw, a dam chhunga a inthlak emaw chuan, a rah chhuah ha lo, orbital bones-a malalignment emaw, symptoms persistent, double vision ang chi emaw a thlen thei a ni.
Plate chu ruha nghet taka dah theihna tur screw te chu hun kal zelah a migrate thei a, chu chuan instability emaw revision surgery mamawhna a thlen thei a ni.
Minimally invasive ni mah se, surgery hian a chhehvel tissue, thau, nerve, emaw thisen kalna kawngte pawh a tichhia thei tho a ni. Hetiang hlauhawmna hi tih tlem nan ruahmanna fel tak siam leh surgical technique hman a ngai a ni.
A then phei chuan implant hian hrehawmna emaw natna rei tak emaw a thlen thei a, a bik takin a bul hnaia nerve emaw tissue emaw nena inzawm a nih chuan.
Scarring hi a hlauhawm thei hle a, a bik takin a luh theihna tur emaw, a dam chhunga harsatna a thlen chuan emaw incision lian zawk a ngai a nih chuan.
Khawvel mipui an pun zel avangin accident leh trauma case awm tam zel a nih avangin 1.5mm orbital plate ang chi solution tha tak tak mamawhna a sang chho zel dawn a ni.
Minimally invasive technique leh surgical tools lama thil thar chhuah chhunzawm zel chuan thin, anatomically designed implants hman a tipung ang a, 1.5mm orbital plate pawh a tel ang.
Cosmetic leh reconstructive surgery mamawhna a sang chho zel a, a bik takin face trauma repairs atan a mamawh a ni. 1.5mm orbital plate hian function leh appearance pahnih siamthatna kawngah hmun pawimawh tak a chang a, aesthetic surgery-ah pawh hmanraw hlu tak a ni.
Material thar zawk leh implant design tha zawk chuan orbital plate te hnathawh a tichak zawk ngei ang. 3D printing technology leh custom-designed implant te hian orbital fracture enkawlna chu a tidanglam lehzual thei a ni.
Emerging market-a healthcare technology hmasawn tak tak hman theihna a pun zel avangin khawvel pumah 1.5mm orbital plate ang chi specialized implant hman a nih beisei a ni.
1.5mm orbital plate hi orbital fracture enkawlna atana pawimawh tak a ni. A anatomical design, durable titanium atanga siam hian fit dik tak a pe a, orbital bones fractured te tan stable support a pe bawk. A thin profile hmang hian plate hian minimally invasive surgery a siam thei a, chu chuan recovery time a ti tlem a, complication a ti tlem a, functional leh aesthetic outcome tha zawk a thlen bawk.
Implant nena inzawm hlauhawmna chu a hniam hle nachungin, natna kai, plate malposition, emaw tissue chhiatna ang chi harsatna awm lo turin surgical technique dik tak leh post-operative care te hi a pawimawh hle. Facial trauma surgery mamawhna a san chhoh zel chuan 1.5mm orbital plate market chu a zau zel tura ngaih a ni a, hei hi trauma thil thleng tam tak, surgical technique lama hmasawnna te, leh cosmetic leh reconstructive surgery mamawhna a pun zel vang te a ni.
A pum puiin, 1.5mm orbital plate hi orthopedic surgeon-te tan chuan hmanraw pawimawh tak a la ni reng a, damlote mit hnathawh leh hliam na tak tak an tawh hnua an mit hnathawh leh an hmai aesthetics an neih leh theih nan a pui a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | Milem | Item no. | Specification 100 a ni. |
1.5mm orbital plate chi hrang hrang(thickness:0.6mm) | ![]() |
RPYKL1506 a ni. | l a ni. |
RPYKR1506 a ni. | R 10 a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico team te chu 1.5mm orbital plate product catalog ah zawt rawh.
2. I duh ber 1.5mm orbital plate product thlang rawh.
3. 1.5mm orbital plate test tur sample dil rawh.
4.XC Medico 1.5mm orbital plate order siam rawh.
5.XC Medico-a 1.5mm orbital plate-a dealer ni rawh.
1.1.5mm orbital plate a lei man tha zawk.
2.100% Quality sang ber 1.5mm orbital plate a ni.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. 1.5mm orbital plate tling tak a ni.
6. XC Medico-a 1.5mm orbital plate hman dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
1.5mm orbital plate hi orbital fracture enkawlna atana hman thin, a bik takin orbital floor leh bangte nghawng thei tur, orthopedic implant pawimawh tak a ni. A hna ber chu mit socket (orbit) anatomical structure siam that leh a ni a, hei hi visual function leh facial aesthetics pahnih humhalh nan a pawimawh hle. He guide kimchang tak hian 1.5mm orbital plate-a a features, advantages, treatment applications, risks, leh market outlook te a zirchiang a, chu chuan medical professionals te chu surgical outcome hlawhtling tak tak pui turin hriatna chipchiar tak pek a tum a ni.
1.5mm orbital plate hi orbital fracture siamthatna atana hman thin titanium implant te tak te, siam dik tak a ni. Orbital fracture hi thil thleng rapthlak tak tak, blunt force hliam, motor accident, emaw sports-related trauma te avanga lo awm a ni fo thin. Heng ruh tliakte hian harsatna a thlen thei a, chu chu double vision, restricted eye movement, leh facial deformities te a ni. 1.5mm orbital plate hi orbital structure integrity siam that leh, ruh tliakte thlawpna leh mit socket vel a awmna hmun tihngheh nan siam a ni.
Plate hi titanium atanga siam a ni a, biocompatible material a ni a, a chakna, a chhe thei lo, a chhe thei lo tih hriat a ni. 1.5mm thickness hian plate chu minimally invasive a nih theih nan a enkawl a, hei hian incisions te zawk leh recovery time tihtlem hmangin enkawlna tha tak a pe thei a ni. Implant’s anatomical shape chu orbital cavity natural curvature nen a inmil a, damlo outcome fit leh tihchangtlunna dik tak a pe a ni.
Plate hi orbital floor leh wall-a natural curvature mirror tura siam a ni. Hei hian fit dik zawk leh ruh structure hmasa ber siamthatna tha zawk a siamsak a ni.
A chakna, a rit lo hle a, biocompatibility a neih avangin hriat lar a ni a, Titanium hi mit chhehvela hmun nalh takah dah implant siamna atana hman tur thil tha ber a ni. Infection hlauhawmna a ti tlem a, hun rei tak chhung dinhmun nghet tak a siamsak bawk.
Titanium hi radiolucent a ni a, chu chu x-ray emaw CT scan emaw ang chi imaging technique a tibuai lo tihna a ni. Hei hi damna enfiah leh operation hnua harsatna awm thei hmuhchhuahna atan a pawimawh hle.
Plate hi orbital region nena inmil turin pre-formed a ni a, operation neih chhunga implant siam dan tur atana hun leh tha mamawh a tlem phah a ni. Mahse, plate hian a tul angin adjustment tenau te pawh a awm theih nan flexibility level a nei reng a ni.
Plate-ah hian implant chu a chhehvel ruh thlenga nghet taka dah theihna tur screw holes a awm a ni. Hei hian stability tihpun a pe a, dam chhunga implant displacement awm theihna a ti tlem bawk.
A profile thin avangin plate hian minimally invasive surgery a siam thei a, hei hian soft tissue trauma a ti tlem a, recovery process a ti chak bawk.
Orbital floor emaw wall emaw siam that hian implant hian mit socket natural shape leh function a humhim thei a, chu chuan mit lama harsatna leh hmel lanna a ti tlem thei a ni.
1.5mm orbital plate pre-shaped nature hian intraoperative bending emaw customization emaw mamawhna a ti tlem a, chu chuan surgery hun chhung a ti tawi a ni.
Minimally invasive approach, plate design dik tak nen chuan recovery time rang zawk, postoperative pain tlem zawk, leh normal activities-a kir leh thuai a thlen thei a ni.
Titanium’s corrosion resistance hian plate hian hun kal zelah a chakna leh a dinhmun a vawng reng thei a, chu chuan implant a chhiat theihna leh revision surgery a mamawhna a ti tlem a ni.
Implant’s design leh a hman dan tha tak tak hman hian natna kai theihna a ti tlem a, chu chu infection, plate migration, emaw tissue chhiatna te a ni.
Heng ruh tliakte hi thil bengchheng tak tak (blunt) in orbit a tihchhiat chuan a lo awm a, chu chuan orbital floor emaw wall emaw a ti chhe thin. 1.5mm orbital plate hian blowout fractures enkawlna kawngah a thawk tha hle a, a chhan chu ruh tliakte chu a ti nghet a, a chhehvela thil awmte, ruh tliakna hmuna awm thei, taksa ruh emaw thau emaw a tihchhiat belh loh nan a pui a ni.
Chungte chu orbit-a ruh perimeter-a break awmte a ni. Chutiang hunah chuan 1.5mm plate hian orbital floor-ah structural reinforcement a pe a, orbital architecture pumpui a thlawp bawk.
Thil henkhatah chuan orbital floor leh bang pahnih nghawng thei tam tak a awm a. 1.5mm orbital plate hi surgical implant dang nen a inzawm thei a, chu chuan complex fractures te chu a hmachhawn thei a, orbital structure chu a siam thar leh vek theih bawk.
Orbital floor chu a tam thei ang bera a inthlak chuan plate hian ruh fragment te chu a stabilize thei a, displacement a veng thei a, damna dik tak a fuih thei bawk.
Implant hmanga surgical procedure dang ang bawkin, natna kai theihna a awm bawk. Hetiang hlauhawmna tihziaawmna tur hian sterilization technique dik tak, antibiotic prophylaxis, leh post-operative care te hi a pawimawh hle.
Plate chu dik lo taka dah emaw, a dam chhunga a inthlak emaw chuan, a rah chhuah ha lo, orbital bones-a malalignment emaw, symptoms persistent, double vision ang chi emaw a thlen thei a ni.
Plate chu ruha nghet taka dah theihna tur screw te chu hun kal zelah a migrate thei a, chu chuan instability emaw revision surgery mamawhna a thlen thei a ni.
Minimally invasive ni mah se, surgery hian a chhehvel tissue, thau, nerve, emaw thisen kalna kawngte pawh a tichhia thei tho a ni. Hetiang hlauhawmna hi tih tlem nan ruahmanna fel tak siam leh surgical technique hman a ngai a ni.
A then phei chuan implant hian hrehawmna emaw natna rei tak emaw a thlen thei a, a bik takin a bul hnaia nerve emaw tissue emaw nena inzawm a nih chuan.
Scarring hi a hlauhawm thei hle a, a bik takin a luh theihna tur emaw, a dam chhunga harsatna a thlen chuan emaw incision lian zawk a ngai a nih chuan.
Khawvel mipui an pun zel avangin accident leh trauma case awm tam zel a nih avangin 1.5mm orbital plate ang chi solution tha tak tak mamawhna a sang chho zel dawn a ni.
Minimally invasive technique leh surgical tools lama thil thar chhuah chhunzawm zel chuan thin, anatomically designed implants hman a tipung ang a, 1.5mm orbital plate pawh a tel ang.
Cosmetic leh reconstructive surgery mamawhna a sang chho zel a, a bik takin face trauma repairs atan a mamawh a ni. 1.5mm orbital plate hian function leh appearance pahnih siamthatna kawngah hmun pawimawh tak a chang a, aesthetic surgery-ah pawh hmanraw hlu tak a ni.
Material thar zawk leh implant design tha zawk chuan orbital plate te hnathawh a tichak zawk ngei ang. 3D printing technology leh custom-designed implant te hian orbital fracture enkawlna chu a tidanglam lehzual thei a ni.
Emerging market-a healthcare technology hmasawn tak tak hman theihna a pun zel avangin khawvel pumah 1.5mm orbital plate ang chi specialized implant hman a nih beisei a ni.
1.5mm orbital plate hi orbital fracture enkawlna atana pawimawh tak a ni. A anatomical design, durable titanium atanga siam hian fit dik tak a pe a, orbital bones fractured te tan stable support a pe bawk. A thin profile hmang hian plate hian minimally invasive surgery a siam thei a, chu chuan recovery time a ti tlem a, complication a ti tlem a, functional leh aesthetic outcome tha zawk a thlen bawk.
Implant nena inzawm hlauhawmna chu a hniam hle nachungin, natna kai, plate malposition, emaw tissue chhiatna ang chi harsatna awm lo turin surgical technique dik tak leh post-operative care te hi a pawimawh hle. Facial trauma surgery mamawhna a san chhoh zel chuan 1.5mm orbital plate market chu a zau zel tura ngaih a ni a, hei hi trauma thil thleng tam tak, surgical technique lama hmasawnna te, leh cosmetic leh reconstructive surgery mamawhna sang zel te a ni.
A pum puiin, 1.5mm orbital plate hi orthopedic surgeon-te tan chuan hmanraw pawimawh tak a la ni reng a, damlote mit hnathawh leh hliam na tak tak an tawh hnua an mit hnathawh leh an hmai aesthetics an neih leh theih nan a pui a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp