RP2FGY a ni
XCmedico a ni
Fibula a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Thilsiam | Pic | Inherh | REF. | Spec. |
| Distal Fibula Plate-II-ah chuan a awm a | ![]() |
HA 3.5 HB 4.0 a ni |
RP2FGY3HL a ni | 3H L. a ni |
| RP2FGY4HL a ni | 4H L. a ni | |||
| RP2FGY5HL a ni | 5H L. a ni | |||
| RP2FGY6HL a ni | 6H L. a ni | |||
| RP2FGY7HL a ni | 7H L. a ni | |||
| RP2FGY8HL a ni | 8H L. a ni | |||
| RP2FGY3HR a ni | 3H R. a ni | |||
| RP2FGY4HR a ni | 4H R. a ni | |||
| RP2FGY5HR a ni | 5H R. a ni | |||
| RP2FGY6HR a ni | 6H R. a ni | |||
| RP2FGY7HR a ni | 7H R. a ni | |||
| RP2FGY8HR a ni | 8H R. a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team te hnenah Distal Fibula Plate-II Product Catalog zawt rawh.
2. I duhzawng Distal Fibula Plate-II Product thlang rawh.
3. Distal Fibula Plate-II Test turin Sample Dil rawh.
4.XC Medico-a Distal Fibula Plate-II Order siam rawh.
5.XC Medico-a Distal Fibula Plate-II Dealer ni rawh.
1.Distal Fibula Plate-II lei man tha zawk.
2.100% A quality sang ber Distal Fibula Plate-II.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Distal Fibula Plate-II tling tawk.
6. XC Medico-a Distal Fibula Plate-II-a tehna rang leh awlsam tak.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.

Orthopaedic hmasawnna chuan fracture fixation methods tihchangtlun a tum chhunzawm zel a, surgeon leh damlote tan pawh outcome tha zawk siam a ni. Heng thil thar chhuah zingah hian Distal Fibula Plate-II hi complex distal fibula fracture enkawlna atana hmanraw pawimawh takah a lo chhuak ta a ni. He thuziak hian Distal Fibula Plate-II chungchang chipchiar takin a chhui a, a features, a thatna, fracture application leh thil dang tam tak a tarlang a, medical professional leh zirlai te tan hriatthiamna zau tak a tichiang a ni.
Distal Fibula Plate-II hi second-generation orthopedic implant a ni a, distal fibula region-a ruh tliak, a bik takin lateral malleolus bula ruh tliak te chiang taka enkawlna atana siam a ni. A hmaa a hlawhtlinnate chu siamin, he plate hian anatomical contouring tihchangtlun, fixation option tha zawk, leh surgical technique hmasawn tak takte nena inmilna a rawn keng tel a ni.
He implant hi lateral malleolar fracture, bimalleolar fracture, leh hliam dang complex tak tak, stable fixation leh optimal anatomical alignment mamawhna hmunah te hman a ni fo thin. A design-ah hian harsatna tihziaawmna tur, damna awlsam zawk siamna tur leh damlo taksa peng hrang hrangte awm theihna tur features a keng tel a ni.
He plate hi fibula natural curvature ang deuha siam a ni a, a fit dik tak a ni a, intraoperative adjustment mamawhna a ti tlem bawk.
Locking leh non-locking screw pahnih tan option a pe a, stable fixation neih theihna kawngah flexibility a pe a, a bik takin osteoporotic bones-ah.
Ultra-thin design hian a chhehvel soft tissue-te irritation a ti tlem a, postoperative complications a ti tlem a ni.
Plate hian screw te chu angle hrang hranga dah theihna a siam a, hei hian surgeon te tan screw positioning tha ber neih theihna turin zalenna nasa zawk a pe a ni.
Heng holes te hi strategically positioned an ni a, screw tam tak awm theihna turin comminuted emaw challenging fractures ah stabilization tha zawk neih theih nan.
Titanium alloy hmanga siam niin, plate hi a rit lo a, a chhe thei lo a, biocompatible a ni a, hun rei tak chhunga hlawhtlinna a tichiang a, hnawl theihna a tlem hle.
A locking mechanism hmasawn tak hian stabilization rintlak tak a siam a, fracture pattern harsa emaw ruh quality tha lo emaw pawh nise.
Low-profile design hian peroneal tendons leh a chhehvel tissue-te irritation a veng a, damlote chu operation hnua an thlamuanna a tichiang a ni.
Plate hian screw chi hrang hrang leh screw angle hrang hrang a dah theihna avangin fracture configuration hrang hrang leh ruh anatomy hrang hrang atan a tha hle.
Pre-contoured leh anatomically designed, plate hian intraoperative shaping zau tak mamawhna a ti tlem a, surgical time a ti tawi a, intraoperative stress a ti tlem bawk.
A fixation property chak tak avang hian damlote chu weight-bearing activities te chu an tan thuai thei a, hei hian dam chak zawk a tichak a, immobilization avanga harsatna awmte a tiziaawm bawk.
Plate hian ankle lateral side chu a stabilize a, joint alignment dik tak a vawng reng a, optimal healing atan.
Fracture-ah hian malleoli tam tak a awm chuan plate hian lateral component tan fixation him tak a pe a, medial leh posterior malleoli surgical management chu a tichak hle.
Tibial plafond thlenga high-energy injury-ah chuan Distal Fibula Plate-II hian fibula stabilize-na kawngah a pui a, complex reconstruction-ah outcome tha zawk a awm thei a ni.
Damlo tar ruh chhe thei lo tan chuan locking screw mechanism hian lei leh nghet zawk a pe a ni.
Plate hi ruh tumor emaw cyst emaw avanga pathological fracture a awm pawhin hman theih a ni a, ruh structure tihchhiat te tan pawh support nghet tak a pe a ni.
Surgical implant dang ang bawkin, natna kai theihna a awm a, a bik takin comorbidities nei emaw, postoperative care mumal lo emaw nei damlote tan chuan a hlauhawm hle.
A tlem berah chuan screw emaw plate emaw chu stress nasa lutuk a nih chuan emaw, a ruh chu a dam tawk lo a nih chuan a lo chhuak emaw, a chhe emaw thei.
Fracture thenkhat chu beisei aia hniam zawkin a dam thei a, a dam vek thei lo a, chu chuan inrawlh belh a ngai a ni.
A dah dik loh emaw, soft tissue clearance tling lo emaw chuan a ti na thei a, a hring thei a, tendon pawh a tichhia thei bawk.
A awm lo nain, titanium ang chi implant material-a hypersensitivity hi a vei thei zingah a awm thei a ni.
Surgery technique ha lo emaw, taksa peng hrang hrang (anatomy) harsa tak emaw chuan a bul hnaia nerve emaw thisen kalna kawng emaw chu accident-in a tichhia thei a ni.
Patient-specific implant atana 3D printing inzawmkhawm leh bioresorbable materials siam chhuah hian nakin lawka design-te a tichangtlung hle tura ngaih a ni.
Kum upa tawhte chu ruh natna leh ruh tliak vei an nih avangin fixation device rintlak mamawhna a sang chho hle tura ngaih a ni.
Minimally invasive surgery chu standard a nih chhoh zel avangin Distal Fibula Plate-II ang chi low-profile, anatomically contoured plate te hian mi tam takin an pawm a rinawm.
Asia-Pacific, Latin America leh Middle East-a healthcare infrastructure lo thang zel hian orthopaedic device siamtute tan an thlen theihna tur kawng a siam mek a ni.
Eco-friendly manufacturing leh biocompatible materials lama ngaih pawimawh zual zel hian orthopedic implants hmalam hun tur a siam mek a ni.
Distal Fibula Plate-II hian orthopedic fracture fixation lama hmasawnna nasa tak a entir a, stability, adaptability leh damlote thlamuanna tluk loh a pe a ni. A thil thar, polyaxial locking system leh anatomical contouring te hian fracture chi hrang hrangah outcome tha zawk a siam thei a ni. A hmanna avanga hlauhawmna awm thei chu a tlem hle a, enkawl theih a nih laiin, a dam thuai theihna te, harsatna a tihziaawmna te, leh damlote lungawina tihpunna te hian tunlai ruh lam surgery-a hmanraw pawimawh tak a nihna a tichak a ni.
Technology lama hmasawnna leh khawvel pum huapa healthcare mamawhna a lo thang zel a, Distal Fibula Plate-II hian fracture management hmalam hun siamna kawngah hmun pawimawh tak a chang dawn a, damlo leh healthcare provider-te tan pawh result tha zawk a pe thei dawn a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp