RPJYWS a ni
XCmedico a ni
Tibia tih hi a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Thilsiam | Milem | Ref | A sawifiahna | Inherh |
| Distal Tibia Lateral Locking Plate chu a awm a, a chhuahna tur hmun chu a inthlau hle | ![]() |
RPJYWS5HR a ni | 5 H R. a ni | HA4.5 HC5.0 a ni |
| RPJYWS5HL a ni | 5 H L. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS7HR a ni | 7 H R. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS7HL a ni | 7 H L. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS9HR a ni | 9 H R. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS9HL a ni | 9 H L. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS11HR a ni | 11 H R. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS11HL a ni | 11 H L. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS13HR a ni | 13 H R. a ni | HA4.5 HC5.0 a ni | ||
| RPJYWS13HL a ni | 13 H L. a ni | HA4.5 HC5.0 a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team te hnenah Distal Tibia Lateral Locking Plate Product Catalog zawt rawh.
2. Distal Tibia Lateral Locking Plate Product I duhzawng thlang rawh.
3. Distal Tibia Lateral Locking Plate Test turin Sample Dil rawh.
4.XC Medico-a Distal Tibia Lateral Locking Plate chu Order siam rawh.
5.XC Medico-a Distal Tibia Lateral Locking Plate Dealer ni rawh.
1.Distal Tibia Lateral Locking Plate lei man tha zawk.
2.100% Distal Tibia Lateral Locking Plate tha ber ber a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Distal Tibia Lateral Locking Plate tling tawk.
6. XC Medico-a Distal Tibia Lateral Locking Plate chu rang leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.

Distal tibia hi ke hnuai lam thil pawimawh tak a ni a, ke ruh rit phurtu ber a ni. Distal tibia fracture hian mobility nasa takin a nghawng thei a, a damna tur dik tak atan surgical intervention chiang tak a ngai a ni. Hemi biala complex fracture enkawlna atana hmanraw pawimawh tak Distal Tibia Lateral Locking Plate hi a lo chhuak ta a ni. Enhanced stability leh support pein, he implant hi healing process awlsam zawka siam a ni a, chutih rualin complication awm theihna a tihziaawm bawk. He guide hian distal tibia lateral locking plate, a features, a thatna leh clinical relevance te ngun takin a chhui a ni.
Distal tibia lateral locking plate hi specialized orthopedic implant a ni a, distal tibia fracture stabilize nan hman a ni a, a bik takin comminuted emaw complex fracture emaw a awm chuan.he plate hi distal tibia lateral surface nena inmil tura siam a ni a, simple leh complex fracture tan pawh secure fixation a pe a ni. Locking screw a nei a, chu chuan angular stability a pe a, screw loosening a veng a, healing process-ah alignment dik tak a siam bawk.
Locking screw hian stability a tichak a, ruh tliak segment te chu a inthlak danglam thei lo.
Model thenkhatah chuan polyaxial screw holes a awm a, chu chuan screw dahna kawngah pawh a inthlak danglam thei a, thil harsa tak takah pawh fixation him tak a siam thei a ni.
Plate thenkhatah chuan ligament emaw tendon emaw siamthatna tur suture hole dang a awm a, chu chuan a chhehvel structure te chu a ti nghet zual sauh a ni.
Low-profile design hian soft tissue tihbuai a ti tlem a, hei hian a dam chak zawk a, operation hnua natna pawh a ti tlem bawk.
Stable fixation hian fracture chu a aligned reng thei a, ruh damna tha ber a siam a, non-union hlauhawmna a ti tlem bawk.
Plate hi fracture chi hrang hrangah a insiamrem thei a, chung zingah chuan simple, comminuted, leh unstable fracture te pawh a tel.
Plate hian ruh chi hrang hrang a secure nasa hle a, malunion emaw non-union emaw a awm theihna a ti tlem hle.
Tibia leh fibula pahnih a tliak chuan distal tibia lateral locking plate hian tibial fracture tan stable fixation a pe a, chutih rualin fibula tan fixation technique dang a phalsak bawk.
Ankle joint chhunga inzar pharh fracture tan chuan plate hian joint alignment vawng reng turin a pui thei a, post-traumatic arthritis a veng thei bawk.
Locking mechanism hian ruh density tlahniam damlote tan fixation tha zawk a pe a, implant failure hlauhawmna a ti tlem a ni.
Lateral plate hi technique dang nen hman dun theih a ni a, associated ligamentous injuries siamthat nan hman theih a ni a, hei hian overall joint stability a tichiang thei a ni.
Postoperative infection hi ngaihtuahawm tak a ni a, a bik takin high-risk patient emaw, immune system tihchhiat emaw tan chuan ngaihtuahawm tak a ni.
Tibia hi nerve leh thisen kalna kawng pawimawh tak takte nen a inzawm tlat a, screw dah dik loh chuan nerve tihchhiat emaw, vascular compromise emaw a thlen thei a ni.
Stable fixation awm mahse, fracture thenkhat chu a dam tha thei lo a, intervention dang a ngai bawk.
A tlem hle nachungin, plate emaw screw emaw a chhe thei a, a bik takin dah dik loh emaw, load tam lutuk emaw avanga fixation tihchhiat a nih chuan.
Damlote chuan implant hmunah natna emaw, nuam lo emaw an nei thei a, a bik takin plate hian a chhehvel soft tissue a ti na a nih chuan.
Orthopaedic implant hmalam hun chu damlo bik solution lam pan mek a ni a, chutah chuan 3D printing emaw advanced imaging technique hmangin mimal taksa peng hrang hranga implant siam a ni. Hei hian fracture fixation dik leh tangkai zawk a tipung ang.
Minimally invasive surgical technique lama hmasawnna chuan incision tenau zawk, soft tissue-a trauma tlem zawk, leh damlote tan dam rei zawk a thlen mai thei.
Khawvel pumah healthcare access a ṭhat chhoh zel avangin, a bik takin ram changkang zawkah chuan distal tibia lateral locking plate ang chi advanced fracture fixation solutions mamawhna a sang zel dawn a ni.
Thutawp atan chuan Distal Tibia Lateral Locking Plate hi tunlai orthopaedic practice-a hmanraw pawimawh tak a ni a, distal tibia fracture enkawlna atan fixation leh stability tha zawk a pe a ni. A design hmasawn tak hian fracture alignment tha ber a siam a, soft tissue chhiatna a ti tlem a, a dam chak zawk bawk. A features, a thatna leh a hlauhawmna te hriatthiamna hmang hian healthcare provider te chuan complex tibial fracture vei damlote tan result tha ber an pe thei a ni. Technology a lo thang chho zel a, he implant hmalam hun hi a beisei awm zawkin a lang a, surgical precision, damlote outcome leh hun rei tak chhunga dam leh theihna tihchangtlunna tur thil thar siam a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp