RPRT a ni
XCmedico a ni
Cranial a ni
1 Pcs(Darkar 72 chhunga thawn chhuah)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Hming | Milem |
Item No. | A sawifiahna |
| Mastoid Interlink Plate chu a awm a | ![]() |
RPRT06S a ni | 0.6mm, S. a ni |
| RPRT06M a ni | 0.6mm, M. a ni | ||
| RPRT06L a ni | 0.6mm, L. a ni | ||
![]() ![]() |
RPRT2063030 a ni | 30*30mm a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team te hnenah Mastoid Interlink Plate Product Catalog zawt rawh.
2. Mastoid Interlink Plate Product I duhzawng thlang rawh.
3. Mastoid Interlink Plate Test turin Sample Dil rawh.
4.XC Medico-a Mastoid Interlink Plate Order siam rawh.
5.XC Medico-a Mastoid Interlink Plate Dealer ni rawh.
1.Mastoid Interlink Plate lei man tha zawk.
2.100% Mastoid Interlink Plate tha ber ber a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Mastoid Interlink Plate tling tawk.
6. XC Medico-in Mastoid Interlink Plate a siam dan awlsam leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
Mastoid Interlink Plate hi orthopedic implant specialized tak a ni a, beng bula temporal bone area pakhat mastoid region-a fracture awmte chu secure fixation pe thei tura siam a ni. He kaihhruaina hian Mastoid Interlink Plate nena inzawm thil awm dan, a thatna, a hman dan leh a hlauhawm theih dan te ngun takin a thlir a, healthcare professional-te tan pawh hriatthiamna zau tak a pe a, chung zingah chuan surgeon, medical zirlai leh professor te pawh an tel a ni.
Mastoid Interlink Plate hi surgical implant a ni a, a bik takin mastoid bone-a fracture stabilization atan hman a ni a, hei hi luruh temporal bone-a tel a ni. Mastoid bone hian anatomical structure pawimawh tak tak awmnaah hmun pawimawh tak a chang a, chung zingah chuan middle ear leh cranial nerve hrang hrang te pawh a tel a ni. Hemi hmuna ruh tliak hi lu hliam emaw, accident emaw ang chi trauma avanga lo awm fo a ni a, a damna tur dik tak leh harsatna awm thei tur tih tlem nan stabilization dik tak a ngai thin.
Titanium emaw titanium alloy ang chi biocompatible material atanga siam niin, Mastoid Interlink Plate hi interlocking screw mechanism hmanga siam a ni a, hei hian a dam chhungin stability a ti sang hle. Plate design hian ruh chi hrang hrangte chu a inmil reng theih nan a pui a, chu chuan a dam chak zawk a, harsatna awm theihna a ti tlem bawk.
Titanium hi biocompatibility leh corrosion laka a do theih avangin implant atana hmanraw tha tak a ni. Ruh tissue nen a inzawm tha hle a, fixation rei tak leh nghet tak a siam thei a ni.
Interlocking screw hian hun kal zelah screw a lo chhuah loh nan plate stability a tichak a, hei hi fracture alignment dik tak neih theihna tur leh ruh tihdam awlsamna atana pawimawh tak a ni.
Plate hi a bik takin mastoid ruh natural shape nena inmil tura siam a ni. He anatomical fit hian surgery neih laiin siamthat ngai a ti tlem a, support tha zawk a pe bawk.
Titanium hi X-ray-ah a langtlang thei a, implant atanga tihbuai awm lovin a dam dan awlsam taka enfiah theih a ni.
Mastoid Interlink Plate hi damlo taksa peng hrang hrang leh ruh tliak chi hrang hrang awm theihna turin size hrang hrang a awm a, hei hian enkawlna ruahmanna siam thei a ni.
Screw leh plate inkar interlocking mechanism hian fixation nghet tak a pe a, healing process chhunga fracture displacement hlauhawmna a ti tlem hle.
Ruh chi hrang hrangte chu him taka stabilization a nih theih nan Mastoid Interlink Plate hian nonunion, malunion, implant failure ang chi harsatna a thlen theihna a ti tlem a ni.
Plate-a anatomical design hian operation neih laiin dissection zau tak neih a ngai lo a, soft tissue tihchhiat a ti tlem a, a dam thuai theih nan a pui bawk.
Titanium chakna leh corrosion laka a do theihna hian plate chu a awm reng a, hun kal zelah a thawk thei a, ruh chu rei tak chhung atan a pui thei a ni.
Bone alignment leh stability tha ber a siam avangin Mastoid Interlink Plate hian damna rang zawk leh sawi lawk theih zawkah a pui a ni.
Heng ruh tliak te hi mastoid ruh chu a then hrang hrangah a inthen a ni. Locking screw mechanism hian fragment te chu a stabilize thei a, alignment dik tak a siam a, damna a ti awlsam bawk.
Mastoid ruh atanga simple crack awm chu Mastoid Interlink Plate hmangin tha takin enkawl theih a ni a, chu chuan displacement a veng thei a, damna a tichak bawk.
Heng ruh tliak te hi ruh sir zawng zawnga horizontal-a awm te hian plate-a fixation chak tak avang hian hlawkna an hmu a, hei hian ruh tawp te chu a dam chhungin a vawng tlat thei a ni.
Plate hian ruh hnah hring (displaced bone fragments) te chu a hmunah nghet taka vawn a nih theih nan a enkawl a, hei hian a inmil lohna emaw, harsatna dang emaw a thlen theihna a ti tlem a ni.
Fracture hi luruh base thlenga a inzar pharh chuan Mastoid Interlink Plate hian ruh chu a ti nghet thei a, beng chhung lam, nerve leh thisen kalna te ang chi thil pawimawh tak tak tihchhiat a veng bawk.
Surgery dang ang bawkin, incision site emaw, implant chhehvelah emaw natna kai theihna a awm. Hetiang hlauhawmna hi a tlem theih nan sterile technique dik tak leh post-operative care hman a pawimawh hle.
Mastoid region hi critical cranial nerve te nen a inhnaih hle a, chung zingah chuan facial nerve leh vestibulocochlear nerve te pawh a tel a ni. Plate hi surgery hmanga dah a nih hian nerve hliam a awm thei a ni.
A tlem berah chuan plate hian fixation a pe tawk lo thei a, chu chuan ruh a inthlak emaw, a ruh chu a inzawm lo emaw a ni thei. Hei hian revision surgery a ngai thei a ni.
Temporal region-a vascular nature avang hian hematoma siam theihna a awm a, chu chu drainage emaw, intervention dang emaw a ngai thei a ni.
Hun a kal zel a, implant chhehvel ruh chu a chak lo thei a, a bik takin damlote tan chuan hun rei tak chhung che thei lo emaw, an dam laiin rit phur lutuk emaw an nei thin.
Mipui tar chak lutuk leh traumatic injuries rate sang zawk, a bik takin lu leh kawr trauma te avang hian Mastoid Interlink Plate ang chi orthopedic implant rintlak mamawhna a sang chho zel dawn niin an sawi.
Materials science lama zirchianna leh hmasawnna kalpui mek hian thil chak zawk, chhe thei lo zawk leh bioactive zawk siam a thlen thei a, hei hian Mastoid Interlink Plate hnathawh a tichak thei a ni.
Technology thar chhuak, 3D printing leh damlo bik implant te hian damlo tinte taksa peng hrang hrang mamawh bik nena inmil zawk, customized Mastoid Interlink Plates a siam thei a ni.
Ram changkang zawka healthcare access a ṭhat chhoh zel avangin Mastoid Interlink Plate ang chi advanced surgical implant mamawhna a sang chho zel a rinawm.
Mastoid Interlink Plate hi orthopedic implant bik a ni a, temporal bone mastoid region-a fracture awmte stabilization atana siam a ni. Titanium ang chi thil chak tak tak hmanga siam a ni a, locking screw mechanism a nei a, hei hian fixation tha zawk a pe a ni. Plate hi fracture chi hrang hrang enkawlna atan a tha hle a, comminuted, linear, leh transverse fracture te pawh a awm a, advantage tam tak a nei a, chu chu enhanced stability, minimal soft tissue disruption, leh healing time tihchangtlun te hi a ni.
Hlawkna tam tak nei mah se, operation hian hlauhawmna engemaw zat a nei a, chung zingah chuan infection, nerve injury, leh implant failure te pawh a tel. Mahse, uluk taka surgical planning leh post-operative monitoring hmangin heng risk te hi a tlem thei hle. Advanced trauma solutions mamawhna a san zel avangin Mastoid Interlink Plate hian mastoid region-a fracture enkawlnaah hmun pawimawh tak a chang chho zel dawn a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp