rprt 10 a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Hming | ![]() |
Item no. | Specification 100 a ni. |
Mastoid hmanga siam interlink plate a ni. | ![]() |
RPRT06S a ni. | 0.6mm, s a ni. |
RPRT06M a ni. | 0.6mm a ni a, M a ni. | ||
RPRT06L a ni. | 0.6mm a ni a, l a ni. | ||
![]() ![]() |
RPRT2063030 a ni. | 30*30mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah Mastoid Interlink Plate Product Catalog a awm theih nan zawt rawh.
2. I duh ber mastoid interlink plate product thlang rawh.
3. Mastoid interlink plate test nan sample dil rawh.
4.XC Medico-a mastoid interlink plate order siam tur a ni.
5.XC Medico-a Mastoid Interlink Plate-a dealer ni rawh.
1.Mastoid Interlink Plate lei man tha zawk.
2.100% Mastoid interlink plate quality sang ber a ni.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. Mastoid interlink plate tling tak.
6. XC Medico-a mastoid interlink plate hman dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Mastoid interlink plate hi highly specialized orthopedic implant a ni a, beng bula temporal bone area a mastoid region-a fracture awm theihna tur fixation him tak siam theihna tura siam a ni. He guide hian mastoid interlink plate nena inzawm features, advantages, applications, leh potential risks te ngun taka en a, healthcare professionals te, surgeon te, medical students te, leh professor te tan pawh hriatthiamna zau tak a pe bawk.
Mastoid interlink plate hi surgical implant a ni a, a bul berah chuan mastoid ruha ruh tliakte stabilization atana hman a ni a, hei hi luruh ruh (temporal bone) a tel a ni. Mastoid bone hian anatomical structure pawimawh tak tak, beng lai tak leh cranial nerve chi hrang hrang te pawh a huam tel a ni. Hemi kawngah hian ruh tliak hi trauma avanga lo awm a ni fo thin a, chu chu lu hliam emaw, accident emaw a ni a, damna dik tak neih theihna tur leh harsatna awm thei tur tihtlem nan stabilization dik tak a ngai thin.
Biocompatible materials titanium emaw titanium alloys atanga siam niin, mastoid interlink plate hi interlocking screw mechanism hmanga siam niin, a dam chhunga stability tihpun a ni. Plate design hian ruh fragment te chu alignment-a awm reng a nih theih nan a pui a, chu chuan recovery rang zawk a siam a, harsatna awm thei tur a ti tlem bawk.
Titanium hian biocompatibility leh corrosion a do theih avangin implant atan a tha hle. Ruh tissue nen a inzawm tha hle a, hun rei tak leh nghet taka fixation a awm theih nan a pui bawk.
Interlocking screws hian hun kal zelah screw loosening a veng a, hei hi fracture alignment dik tak vawn reng leh ruh damna awlsam zawka siam nan a pawimawh hle.
Plate hi a bik takin mastoid ruh natural shape nena inmil tura siam a ni. He anatomical fit hian operation neih chhunga siamthat ngai a ti tlem a, support tha zawk a pe bawk.
Titanium hi X-ray-ah a langtlang a, implant atanga inrawlhna awm lovin damna kalpui dan awlsam taka enfiah theih a ni.
Mastoid interlink plate hi damlo anatomies leh fracture chi hrang hrang awm theihna turin size hrang hrang a awm a, hei hian customized treatment plan a siam thei a ni.
Screw leh plate inkara inzawmna (interlocking mechanism) chuan fixation nghet tak a pe a, chu chuan damna kalpui chhunga ruh tliak (fracture displacement) a thlen theihna a ti tlem a ni.
Bone fragments te him taka stabilization a awm theih nan mastoid interlink plate hian nonunion, malunion, emaw implant failure te ang chi complication awm theihna a ti tlem a ni.
Plate anatomical design hian operation laiin extensive dissection mamawhna a ti tlem a, soft tissue chhiatna a ti tlem a, recovery rang zawk a tichak bawk.
Titanium hian corrosion a chakna leh a do theih lohna hian hun kal zelah plate chu a awm reng a, a thawk thei a, chu chuan ruh tan hun rei tak chhung a pui thei a ni.
Optimal bone alignment leh stability tihhmasawn hian mastoid interlink plate hian damna chak zawk leh sawi lawk theih zawk a pui a ni.
Heng ruh tliakte hi mastoid ruh chu a then hrang hranga then darh a ni. Locking screw mechanism hian fragments te chu a ti nghet a, alignment dik tak a siam a, damna a ti awlsam bawk.
Mastoid ruhro across a simple crack chu mastoid interlink plate hmangin a tha thei ang bera enkawl theih a ni a, chu chuan displacement a veng thei a, damna a thlen thei bawk.
Heng ruhro (rune) a inzawm tlat te hian plate-a fixation nghet tak an neih avangin an hlawkpui a, chu chuan ruh tawp te chu a dam leh theih loh hun chhungin a inzawm khawm thei a ni.
Plate hian ruhro fragment displaced te chu a hmunah nghet taka vawn a nih theih nan a enkawl a, hei hian misalignment emaw complication emaw a awm leh theihna tur a ti tlem a ni.
Fracture chu luruh base-ah a inzar pharh chuan mastoid interlink plate hian ruh a ti nghet a, a chhunga beng, nerve, leh thisen kalna kawng pawimawh tak takte a tihchhiat loh nan a pui a ni.
Surgical procedure dang ang bawkin, incision site-ah emaw, implant vel emaw-ah hian natna kai theihna a awm a ni. Hetiang hlauhawmna hi tihtlem nan hian sterile technique dik tak leh post-operative care a pawimawh hle.
Mastoid region hi critical cranial nerve te nen a inhnaih hle a, chung zingah chuan hmai nerve leh vestibulocochlear nerve te pawh a tel. Plate surgery neih chhung hian nerve hliam a awm theihna a awm a, chu chu plate-a dah a nih laiin a ni.
A tlem berah chuan plate hian fixation tha tak a pe thei lo mai thei a, chu chuan ruh displacement emaw, fracture awm lohna emaw a thlen thei a ni. Hei hian revision surgery a mamawh thei a ni.
Temporal region-a vascular nature avang hian hematoma siam theihna a awm a, chu chuan drainage emaw, intervention dang emaw a mamawh thei a ni.
Hun a kal zel a, implant chhehvel ruh chu a chak lo thei a, a bik takin damlo dam leh dam loh laia taksa rihna sang lutuk emaw, taksa rihna tam lutuk emaw nei damlote tan chuan a chak lo thei hle.
Mipui tar chak tak leh hliam na tak tak, a bik takin lu leh kawng trauma an neih tam zawk avangin, mastoid interlink plate ang chi orthopedic implant rintlak tak tak mamawhna a sang chho zel dawn a ni.
Materials science lama zirchianna leh hmasawnna kalpui zel chuan a chak zawk, a chhe thei lo zawk, leh bioactive materials a siam thei a, chu chuan mastoid interlink plate performance a tichak thei a ni.
3D printing leh patient-specific implant ang chi technology thar lo chhuakte chuan damlo tinte taksa peng hrang hrang mamawhna atana tha zawk mastoid interlink plate customized a siam thei a ni.
Developing region-a healthcare access a ṭhat chhoh zel chuan mastoid interlink plate ang chi advanced surgical implant mamawhna a sang chho zel a rinawm.
Mastoid interlink plate hi specialized orthopedic implant a ni a, temporal bone-a mastoid region-a fracture awmte stabilization atana siam a ni. Titanium ang chi, high-strength materials atanga siam a ni a, locking screw mechanism hmangin fixation tha zawk a pe bawk. Plate hi fracture chi hrang hrang enkawlna atan a tha hle a, comminuted, linear, leh transverse fracture te pawh a awm a, advantage tam tak a pe a, chungte chu stability tihpun, soft tissue disruption tlem ber, leh damna hun tha zawk te a ni.
A hlawkna tam tak awm mah se, surgery-a tel tur hian hlauhawmna engemaw zat a awm a, chung zingah chuan hri kai, nerve hliam, leh implant failure te pawh a tel. Mahse, uluk taka surgical planning leh post-operative monitoring a awm chuan heng risk te hi a tlem thei ang bera tih theih a ni. Advanced trauma solutions mamawhna a san zel avangin mastoid interlink plate hian mastoid region-a fractures enkawlna kawngah hmun pawimawh tak a chang chho zel dawn a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | ![]() |
Item no. | Specification 100 a ni. |
Mastoid hmanga siam interlink plate a ni. | ![]() |
RPRT06S a ni. | 0.6mm, s a ni. |
RPRT06M a ni. | 0.6mm a ni a, M a ni. | ||
RPRT06L a ni. | 0.6mm a ni a, l a ni. | ||
![]() ![]() |
RPRT2063030 a ni. | 30*30mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah Mastoid Interlink Plate Product Catalog a awm theih nan zawt rawh.
2. I duh ber mastoid interlink plate product thlang rawh.
3. Mastoid interlink plate test nan sample dil rawh.
4.XC Medico-a mastoid interlink plate order siam tur a ni.
5.XC Medico-a Mastoid Interlink Plate-a dealer ni rawh.
1.Mastoid Interlink Plate lei man tha zawk.
2.100% Mastoid interlink plate quality sang ber a ni.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. Mastoid interlink plate tling tak.
6. XC Medico-a mastoid interlink plate hman dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Mastoid interlink plate hi highly specialized orthopedic implant a ni a, beng bula temporal bone area a mastoid region-a fracture awm theihna tur fixation him tak siam theihna tura siam a ni. He guide hian mastoid interlink plate nena inzawm features, advantages, applications, leh potential risks te ngun taka en a, healthcare professionals te, surgeon te, medical students te, leh professor te tan pawh hriatthiamna zau tak a pe bawk.
Mastoid interlink plate hi surgical implant a ni a, a bul berah chuan mastoid ruha ruh tliakte stabilization atana hman a ni a, hei hi luruh ruh (temporal bone) a tel a ni. Mastoid bone hian anatomical structure pawimawh tak tak, beng lai tak leh cranial nerve chi hrang hrang te pawh a huam tel a ni. Hemi kawngah hian ruh tliak hi trauma avanga lo awm a ni fo thin a, chu chu lu hliam emaw, accident emaw a ni a, damna dik tak neih theihna tur leh harsatna awm thei tur tihtlem nan stabilization dik tak a ngai thin.
Biocompatible materials titanium emaw titanium alloys atanga siam niin, mastoid interlink plate hi interlocking screw mechanism hmanga siam niin, a dam chhunga stability tihpun a ni. Plate design hian ruh fragment te chu alignment-a awm reng a nih theih nan a pui a, chu chuan recovery rang zawk a siam a, harsatna awm thei tur a ti tlem bawk.
Titanium hian biocompatibility leh corrosion a do theih avangin implant atan a tha hle. Ruh tissue nen a inzawm tha hle a, hun rei tak leh nghet taka fixation a awm theih nan a pui bawk.
Interlocking screws hian hun kal zelah screw loosening a veng a, hei hi fracture alignment dik tak vawn reng leh ruh damna awlsam zawka siam nan a pawimawh hle.
Plate hi a bik takin mastoid ruh natural shape nena inmil tura siam a ni. He anatomical fit hian operation neih chhunga siamthat ngai a ti tlem a, support tha zawk a pe bawk.
Titanium hi X-ray-ah a langtlang a, implant atanga inrawlhna awm lovin damna kalpui dan awlsam taka enfiah theih a ni.
Mastoid interlink plate hi damlo anatomies leh fracture chi hrang hrang awm theihna turin size hrang hrang a awm a, hei hian customized treatment plan a siam thei a ni.
Screw leh plate inkara inzawmna (interlocking mechanism) chuan fixation nghet tak a pe a, chu chuan damna kalpui chhunga ruh tliak (fracture displacement) a thlen theihna a ti tlem a ni.
Bone fragments te him taka stabilization a awm theih nan mastoid interlink plate hian nonunion, malunion, emaw implant failure te ang chi complication awm theihna a ti tlem a ni.
Plate anatomical design hian operation laiin extensive dissection mamawhna a ti tlem a, soft tissue chhiatna a ti tlem a, recovery rang zawk a tichak bawk.
Titanium hian corrosion a chakna leh a do theih lohna hian hun kal zelah plate chu a awm reng a, a thawk thei a, chu chuan ruh tan hun rei tak chhung a pui thei a ni.
Optimal bone alignment leh stability tihhmasawn hian mastoid interlink plate hian damna chak zawk leh sawi lawk theih zawk a pui a ni.
Heng ruh tliakte hi mastoid ruh chu a then hrang hranga then darh a ni. Locking screw mechanism hian fragments te chu a ti nghet a, alignment dik tak a siam a, damna a ti awlsam bawk.
Mastoid ruhro across a simple crack chu mastoid interlink plate hmangin a tha thei ang bera enkawl theih a ni a, chu chuan displacement a veng thei a, damna a thlen thei bawk.
Heng ruhro (rune) a inzawm tlat te hian plate-a fixation nghet tak an neih avangin an hlawkpui a, chu chuan ruh tawp te chu a dam leh theih loh hun chhungin a inzawm khawm thei a ni.
Plate hian ruhro fragment displaced te chu a hmunah nghet taka vawn a nih theih nan a enkawl a, hei hian misalignment emaw complication emaw a awm leh theihna tur a ti tlem a ni.
Fracture chu luruh base-ah a inzar pharh chuan mastoid interlink plate hian ruh a ti nghet a, a chhunga beng, nerve, leh thisen kalna kawng pawimawh tak takte a tihchhiat loh nan a pui a ni.
Surgical procedure dang ang bawkin, incision site-ah emaw, implant vel emaw-ah hian natna kai theihna a awm a ni. Hetiang hlauhawmna hi tihtlem nan hian sterile technique dik tak leh post-operative care a pawimawh hle.
Mastoid region hi critical cranial nerve te nen a inhnaih hle a, chung zingah chuan hmai nerve leh vestibulocochlear nerve te pawh a tel. Plate surgery neih chhung hian nerve hliam a awm theihna a awm a, chu chu plate-a dah a nih laiin a ni.
A tlem berah chuan plate hian fixation tha tak a pe thei lo mai thei a, chu chuan ruh displacement emaw, fracture awm lohna emaw a thlen thei a ni. Hei hian revision surgery a mamawh thei a ni.
Temporal region-a vascular nature avang hian hematoma siam theihna a awm a, chu chuan drainage emaw, intervention dang emaw a mamawh thei a ni.
Hun a kal zel a, implant chhehvel ruh chu a chak lo thei a, a bik takin damlo dam leh dam loh laia taksa rihna sang lutuk emaw, taksa rihna tam lutuk emaw nei damlote tan chuan a chak lo thei hle.
Mipui tar chak tak leh hliam na tak tak, a bik takin lu leh kawng trauma an neih tam zawk avangin, mastoid interlink plate ang chi orthopedic implant rintlak tak tak mamawhna a sang chho zel dawn a ni.
Materials science lama zirchianna leh hmasawnna kalpui zel chuan a chak zawk, a chhe thei lo zawk, leh bioactive materials a siam thei a, chu chuan mastoid interlink plate performance a tichak thei a ni.
3D printing leh patient-specific implant ang chi technology thar lo chhuakte chuan damlo tinte taksa peng hrang hrang mamawhna atana tha zawk mastoid interlink plate customized a siam thei a ni.
Developing region-a healthcare access a ṭhat chhoh zel chuan mastoid interlink plate ang chi advanced surgical implant mamawhna a sang chho zel a rinawm.
Mastoid interlink plate hi specialized orthopedic implant a ni a, temporal bone-a mastoid region-a fracture awmte stabilization atana siam a ni. Titanium ang chi, high-strength materials atanga siam a ni a, locking screw mechanism hmangin fixation tha zawk a pe bawk. Plate hi fracture chi hrang hrang enkawlna atan a tha hle a, comminuted, linear, leh transverse fracture te pawh a awm a, advantage tam tak a pe a, chungte chu stability tihpun, soft tissue disruption tlem ber, leh damna hun tha zawk te a ni.
A hlawkna tam tak awm mah se, surgery-a tel tur hian hlauhawmna engemaw zat a awm a, chung zingah chuan hri kai, nerve hliam, leh implant failure te pawh a tel. Mahse, uluk taka surgical planning leh post-operative monitoring a awm chuan heng risk te hi a tlem thei ang bera tih theih a ni. Advanced trauma solutions mamawhna a san zel avangin mastoid interlink plate hian mastoid region-a fractures enkawlna kawngah hmun pawimawh tak a chang chho zel dawn a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp