GX203005 a ni
XCmedico a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Inkawpchawi | Hming | AIH. | Lenzawng tehna | Milem | Qty. | ||
| Pelvic Combinational fixator C chi khat a ni | Double rods clamp a ni | 203002-0808 ah biak theih a ni | φ8/8 a ni | ![]() |
6 | ||
Rod clamp pakhat chauh a awm |
203001-0845 ah biak theih a ni | φ8/4-5 a ni | 6 | ||||
| Curved rod a ni | 203007-0801 ah biak theih a ni | φ8 a ni | 2 | ||||
| Compression /Thil tihbuai theihna rod | 202022-08 chhung atan a ni | φ8 a ni | 1 | ||||
| Connecting rod a ni | SS08-150 ah a awm | φ8×150 a ni | 2 | ||||
| Bone screw hmanga siam a ni | SS10501345 ah a awm | φ5×130 a ni | 6 | ||||
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team hnenah Pelvic Combinational fixator C type Product Catalog dil rawh.
2. I duhzawng Pelvic Combinational fixator C type Product thlang rawh.
3. Pelvic Combinational fixator C type Test turin Sample Dil rawh.
4.XC Medico-a Pelvic Combinational fixator C type Order siam tur a ni.
5.XC Medico-a Pelvic Combinational fixator C type Dealer ni rawh.
1.Pelvic Combinational fixator C type lei man tha zawk.
2.100% Pelvic Combinational fixator C type quality sang ber a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Pelvic Combinational fixator C type tling tawk.
6. XC Medico-a Pelvic Combinational fixator C type hman awlsam leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
Pelvic Combinational Fixator C Type hi pawn lam fixation device thiam tak a ni a, pelvic fracture te chu stability leh precision sang zawka enkawl thei tura siam a ni. He device hian pelvic ring-a complex fracture enkawlnaah hmun pawimawh tak a chang a, orthopaedic surgeon-te tan pelvic trauma stabilization, realignment leh overall management atana hmanraw tangkai tak a pe a ni. He kaihhruaina kimchang tak hian a features, a thatna leh a hman dan te clinical practice-a a chhui a, medical professional, researcher leh zirlai te tan hriatna hlu tak a pe a ni.
Pelvic Combinational Fixator C Type hi external fixation device hmasawn tak a ni a, a bik takin pelvic fracture enkawlna atana siam a ni a, a bik takin pelvic ring nena inzawm a ni. 'C type' hian a design danglam bik, semi-circular design a kawk a, chu chuan device chu pelvis anatomical structure nena inmil turin a phalsak a, chu chuan support leh stabilization tha ber a pe thei a ni. He fixator hi a bik takin pelvic injury complex tak tak, anatomical restoration dik tak mamawhna hmunah chuan a tangkai hle.
Traditional internal fixation method ang lo takin Pelvic Combinational Fixator C Type hi pawn lam atanga hman a ni a, hei hian internal implant avanga natna kai leh harsatna awm thei te a ti tlem hle. Device design-ah hian fracture pattern hrang hrang awm theihna turin adjustable components a awm a, damlo tinte tan tailored solution a pe a ni.
Device C-shaped frame hian pelvis curvature nena inmil takin alignment leh stabilization tha zawk a pe a, healing process chhung hian secure fixation a tichiang a ni.
Fixator hian modular parts a keng tel a, chu chu damlo ruh tliak mamawh bik ang zela siamrem emaw thlak emaw theih a ni a, hei hian personalized treatment approach a tichak a ni.
Titanium emaw stainless steel emaw ang chi thil chhe thei lo atanga siam a ni a, fixator hian hun rei tak chhung support a pe a, chutih rualin adverse reaction emaw infection emaw a awm theihna a ti tlem bawk.
Radiolucent design hian a ruh tliakna hmun chu chiang takin a entir thei a, hei hian damna kal zel dan enfiah leh tehna kalpui zel a ti awlsam hle.
Fixator hian adjustable pin leh screw a hmang a, hei hian fracture alignment chiang taka control theihna leh rehabilitation neih laiin pelvis stability a vawng reng thei a ni.
Fixator hian pelvic fracture tan stability tha tak a pe a, chutih rualin soft tissue tihdamna atan controlled flexibility a pe bawk.
He device hian rigid support a pe a, anatomical alignment a vawng reng a, healing process-ah pelvis chu a stable reng a, complex fracture pawh nise.
External fixator a nih angin he device hian invasive surgery a mamawhna a ti tlem a, a chhehvela tissue te, taksa ruh, nerve leh thisen kalna kawng te chu a humhim thei a ni.
Fixator hi pawn lam atanga hman a nih avangin internal fixation method nena khaikhin chuan natna kai theihna a tlahniam a, a bik takin open fracture a awm chuan.
He device hian controlled movement a phalsak a, weight-bearing leh physical therapy hmasa zawk a tichak a, hei hian deep vein thrombosis (DVT) ang chi complication awm theihna a ti tlem thei a ni.
Fixator-a adjustable components te hian pelvic fracture pattern hrang hrangah a insiamrem thei a, personalized treatment solutions a pe bawk.
Fixator hian radiolucent property a neih avangin post-operative assessment neih laiin clear imaging a siam thei a, ruh dam dan dik taka enfiah theih a ni.
Pelvic ring tibuaitu fracture te chu a stabilize a, a dam chhungin critical alignment leh support a pe bawk.
Pelvis hmun pawimawh tak sacrum fracture enkawlnaah a tangkai a, chutih rualin pelvic structure nghet tak a vawng reng bawk.
Soft tissue chhiatna nei open fracture enkawlna atan a tha a, external fixator hi hman theih a nih laiin infection hlauhawmna a tih tlem bakah hliam enkawlna a awlsam phah bawk.
Ruh a inthen darh a nih chuan hman a ni a, fixator hian anatomical structure dik tak siam that leh ruh alignment vawng reng turin a pui a ni.
Displaced pelvic fractures realigning-ah a pui a, damna dik a siam a, hun rei tak chhunga harsatna awm thei, pelvic malunion emaw instability emaw a tihziaawm bawk.
Pelvic fracture avanga angular emaw rotational deformities lo awm thin siamthat nan hman theih a ni a, optimal functional outcomes a awm theih nan.
Fixator pawn lam thilte hian uluk taka enkawl loh chuan pin insertion site-ah infection a thlen thei a ni.
A then phei chuan fracture te hi a dam rei zawk thei a, stabilization emaw alignment tha tawk loh vangin a dam tha lo thei bawk.
Pin loosening, frame instability, emaw failure emaw a awm fo avangin intervention dang emaw device thlak danglam emaw a ngai thei.
Hun rei tak chhung pawn lam fixator hman hian a chhehvela soft tissue te chu a ti na thei a, a ti na thei a, a ti na thei bawk.
Pelvis hi hun rei tak immobilization a nih chuan joint stiffness emaw, post-recovery mobility tlahniam emaw a awm thei.
Fixator dah dik loh chuan tum loh takin nerve a tichhia thei a, a bik takin complex pelvic fracture a awm thei.
Kawngpuiah lirthei chesual, hnathawhna hmuna hliam, leh infiamna kaihhnawih trauma te hian ruh lam enkawlna mamawhna a tipung dawn niin an sawi.
Tar pung zel hian ruh natna leh kum lama thil dang avanga ruh tliak an nei tam hle a, hei hian pawn lam fixation device-a innghahna nasa zawk a thlen a ni.
Materials, design, leh imaging compatibility lama thil thar siam hian pawn lam fixator te hman tangkai leh nuam tihna a tipung thei a ni.
Damlo leh surgeon-te chuan minimally invasive treatment an thlang nasa hle a, hei hian pelvic leh fracture dangte tan external fixator hman a tipung hle.
Ram thang mekteah chuan healthcare system a lo tha chho zel avangin external fixation devices hman theihna a sang chho zel a, hei hian market opportunity thar a siam a ni.
Pelvic Combinational Fixator C Type hi pelvic fracture enkawlna atana hmanraw tangkai tak leh hmanraw tangkai tak a ni a, stability tihchakna, infection risk tihziaawmna, leh recovery outcome tha zawk a pe a ni. A components adjustable, high-strength materials, leh radiolucent property te hian pelvic fracture chi hrang hrang enkawlna atan a tha hle. A hmannaah hian hlauhawmna engemaw zat a awm laiin, surgical technique dik tak leh post-operative care hian heng ngaihtuahnate hi a tiziaawm thei a ni. Advanced orthopedic device mamawhna a pun zel avangin Pelvic Combinational Fixator C Type hi complex pelvic injury enkawlna atana solution pawimawh tak a la ni reng dawn a, damlote outcome a ti tha ang a, hlawhtling taka dam lehna tur a pui bawk ang.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp