RQSQ01
Xcmedico
1 pcs (72 siegħa kunsinna)
Azzar li ma jissaddadx mediku
CE / ISO: 9001 / ISO13485.ETC
Kunsinna magħmula minn 15-il ġurnata apposta (eskluż il-ħin tat-tbaħħir)
FedEx. Dhl.tnt.ems.etc
Disponibbiltà: | |
---|---|
Kwantità: | |
Prodotti | Stampi | Dettalji | |||
Dwiefer intramedullarju Sett ta 'Tneħħija (PN : RQSQ01) | ![]() ![]() | 1 | N-12-01 | Wrench miftuħ | 1 |
2 | N-12-02 | Wrench | 1 | ||
3 | N-12-03 | Wrench | 1 | ||
4 | N-12-04 | Estrattur Chuck φ1 (tip dritta) | 1 | ||
5 | N-12-05 | Estrattur Chuck φ2 (tip dritta) | 1 | ||
6 | N-12-06 | Estrattur Chuck φ3 (tip dritta) | 1 | ||
7 | N-12-07 | Estrattur Chuck φ4 (tip dritta) | 1 | ||
8 | N-12-08 | Estrattur Chuck φ5 (tip dritta) | 1 | ||
9 | N-12-09 | Estrattur Chuck φ6 (tip dritta) | 1 | ||
10 | N-12-10 | Estrattur Chuck φ7 (tip dritta) | 1 | ||
11 | N-12-11 | Estrattur Chuck φ8 (tip dritta) | 1 | ||
12 | N-12-12 | Estrattur Chuck φ9 (tip dritta) | 1 | ||
13 | N-12-13 | Estrattur Chuck φ10 (tip dritta) | 1 | ||
14 | N-12-14 | Estrattur Chuck φ11 (tip dritta) | 1 | ||
15 | N-12-15 | Estrattur Chuck φ12 (tip dritta) | 1 | ||
16 | N-12-16 | Estrattur Chuck φ13 (tip dritta) | 1 | ||
17 | N-12-17 | Estrattur Chuck φ10 (tip għax-xejn) | 1 | ||
18 | N-12-18 | Estrattur Chuck φ5.5 (tip ta 'għax-xejn) | 1 | ||
19 | N-12-19 | Estrattur Chuck φ4.0 (tip għax-xejn) | 1 | ||
20 | N-12-20 | Estrattur tal-kamin li jsakkar | 1 | ||
21 | N-12-21 | Tornavit Hex SW8.0 | 1 | ||
22 | N-12-22 | Tornavit Hex SW7.0 | 1 | ||
23 | N-12-23 | Tornavit Hex SW5.0 | 1 | ||
24 | N-12-24 | Tornavit Hex SW4.5 | 1 | ||
25 | N-12-25 | Tornavit Hex SW4.0 | 1 | ||
26 | N-12-26 | Tornavit Hex SW3.5 | 1 | ||
27 | N-12-27 | Tornavit Hex SW3.0 | 1 | ||
28 | N-12-28 | Tornavit Hex SW2.5 | 1 | ||
29 | N-12-29 | Martell | 1 | ||
30 | N-12-30 | L-akkoppjar ta 'malajr ta' l-akkoppjar | 1 | ||
31 | N-12-31 | Ġonta universali | 1 | ||
32 | N-12-32 | T Temp Tornavit tat-Tip T Xellug | 1 | ||
33 | N-12-33 | Typynavit Hex tat-Tip T dritt | 1 | ||
34 | N-12-34 | Rod tal-Estrattur | 1 |
It-teknoloġija tal-kontroll numeriku tal-kompjuter tintuża biex tipproċessa b'mod preċiż il-prodotti ortopediċi. Dan il-proċess għandu l-karatteristiċi ta 'preċiżjoni għolja, effiċjenza għolja, u ripetibilità. Jista 'jipproduċi malajr apparat mediku apposta li jikkonforma mal-istruttura anatomika umana u jipprovdi lill-pazjenti bi pjanijiet ta' trattament personalizzati. |
Illustrar tal-prodott L-iskop tal-illustrar tal-prodotti ortopediċi huwa li jtejjeb il-kuntatt bejn l-impjant u t-tessut uman, inaqqas il-konċentrazzjoni tal-istress, u jtejjeb l-istabbiltà fit-tul tal-impjant. |
Spezzjoni tal-kwalità It-test tal-proprjetajiet mekkaniċi tal-prodotti ortopediċi huwa ddisinjat biex jissimula l-kundizzjonijiet tal-istress tal-għadam tal-bniedem, jevalwa l-kapaċità li jġorr it-tagħbija u d-durabilità tal-impjanti fil-ġisem tal-bniedem, u jiżgura s-sigurtà u l-affidabbiltà tagħhom. |
Pakkett tal-prodott Prodotti ortopediċi huma ppakkjati f'kamra sterili biex jiżguraw li l-prodott ikun inkapsulat f'ambjent nadif u sterili biex jipprevjeni kontaminazzjoni mikrobjali u jiżgura s-sigurtà kirurġika. |
Maħżen tal-prodott Il-ħażna ta 'prodotti ortopediċi teħtieġ ġestjoni stretta u kontroll tal-kwalità biex tiżgura traċċabilità tal-prodott u tevita l-iskadenza jew il-vjeġġ ħażin. |
Kamra tal-Kampjun Il-kamra tal-kampjun tintuża biex taħżen, turi u timmaniġġja diversi kampjuni ta 'prodotti ortopediċi għal skambji u taħriġ tat-teknoloġija tal-prodott. |
1
2. Agħżel is-sett ta 'tneħħija tad-dwiefer intramedullarju interessat tiegħek.
3. Itlob kampjun biex tittestja sett ta 'tneħħija tad-dwiefer intramedullarju.
4. Agħmel ordni ta 'sett ta' tneħħija tad-dwiefer intramedullari ta 'XC Medico.
5.Become Negozjant tas-sett ta 'tneħħija tad-dwiefer intramedullari ta' XC Medico.
1. Aħjar ix-xiri tal-prezzijiet tas-sett ta 'tneħħija tad-dwiefer intramedullarju.
2.100% L-ogħla kwalità ta 'tneħħija tad-dwiefer intramedullarju.
3. Inqas sforzi li jordnaw.
4. Stabbiltà tal-prezz għall-perjodu ta 'ftehim.
5. Sett ta 'tneħħija tad-dwiefer intramedullarju suffiċjenti.
6. Valutazzjoni rapida u faċli tas-sett ta 'tneħħija tad-dwiefer intramedullari ta' XC Medico.
7. Marka rikonoxxuta globalment - xc medico.
8. Ħin ta 'aċċess mgħaġġel għat-Tim tal-Bejgħ Medico XC.
9. Test ta 'kwalità addizzjonali mit-tim Medico XC.
10. Traċċar l-ordni xc medico tiegħek mill-bidu sat-tmiem.
Il-kit ta 'tneħħija tad-dwiefer intramedullarju huwa sett ta' strumenti kirurġiċi speċjalizzati ddisinjat biex jgħin lill-kirurgi ortopediċi fl-estrazzjoni tad-dwiefer intramedullari b'mod sikur u effiċjenti minn għadam twil. Id-dwiefer intramedullari jintużaw biex jistabbilizzaw l-għadam miksur u xi kultant jitneħħew wara l-fejqan biex jiġu evitati kumplikazzjonijiet fit-tul jew skumdità. Dan il-kit jiżgura estrazzjoni kkontrollata u preċiża tal-impjant filwaqt li jimminimizza t-trawma għall-għadam tal-madwar u tessut artab.
L-għodda primarja użata biex taqbad u estratt id-dwiefer.
Użat biex iwessa 'l-kanal medullari biex jiffaċilita l-estrazzjoni tad-dwiefer.
Użat biex iħaffer il-viti tal-illokkjar, jekk preżenti.
Użat biex jitneħħew viti li jsakkru mid-dwiefer.
Użat biex jinġibed lura tessuti rotob matul il-proċedura.
L-estrattur huwa magħmul b'manki ergonomiċi, li jiżgura li l-kirurgi jistgħu jżommu qabda sigura matul il-proċedura. Dan id-disinn inaqqas l-għeja bl-idejn u jtejjeb il-kontroll, itejjeb l-effiċjenza kirurġika.
Il-mekkaniżmu tal-ikklampjar għandu jkun preċiż u affidabbli, u jiżgura qabda sigura fuq id-dwiefer.
Mibnija minn azzar tal-istainless steel kirurġiku ta 'grad għoli jew titanju, l-estrattur huwa kemm bijokompatibbli kif ukoll reżistenti għall-ilbies, materjali durabbli biex jifilħu l-forzi involuti fl-estrazzjoni tad-dwiefer , li jiżguraw li jifilħu sterilizzazzjonijiet multipli mingħajr degradazzjoni fil-kwalità.
Il-kit jinkludi diversi adapters kompatibbli ma 'disinji differenti tar-ras tad-dwiefer, li jippermettu lill-estrattur jissakkar b'mod sikur fuq diversi tipi ta' dwiefer intramedullari.
Il-kostruzzjoni robusta tal-istrument tippermetti użu ripetut, li jagħmilha għażla kosteffikaċi għall-isptarijiet u tiżgura prestazzjoni konsistenti maż-żmien.
L-estrattur huwa ddisinjat biex jippermetti estrazzjoni minimament invażiva, li tnaqqas it-trawma għat-tessuti tal-madwar u tirriżulta f'irkupru aktar malajr għall-pazjenti.
It-twaħħil sigur u l-applikazzjoni tal-forza kkontrollata tal-estrattur isaħħu s-sigurtà proċedurali, u jnaqqsu l-probabbiltà ta 'kumplikazzjonijiet bħal ksur tad-dwiefer jew ħsara fit-tessut bi żball.
L-akkoppjar malajr u l-adattabilità ta 'l-estrattur jippermettu t-tneħħija tad-dwiefer aktar mgħaġġla, jiffranka ħin siewi fil-kamra tal-operat u jippermetti lit-tim kirurġiku jaħdem b'mod aktar effiċjenti.
Billi tiffaċilita t-tneħħija tad-dwiefer bi tfixkil minimu fl-għadam, l-estrattur inaqqas l-uġigħ wara l-operazzjoni u ċ-ċans ta 'irritazzjoni residwa mill-impjant.
Il-kompatibilità tal-estrattur ma 'diversi tipi ta' dwiefer tagħmilha adattata għal firxa wiesgħa ta 'proċeduri ortopediċi, minn kirurġiji ta' trawma għal reviżjonijiet kumplessi, li tipprovdi utilità sinifikanti f'ambjenti kliniċi differenti.
Il-kirurgi għandhom jevalwaw sewwa l-kwalità tal-għadam tal-pazjent u l-istat tal-impjant qabel ma jużaw l-estrattur, bħala fatturi bħall-ingrowth tal-għadam madwar id-dwiefer jistgħu jaffettwaw il-proċess tat-tneħħija.
L-estrattur għandu jkun sterilizzat skont il-protokoll biex jipprevjeni l-infezzjoni, speċjalment minħabba l-kuntatt dirett tiegħu ma 'għadam u tessut artab. Sterilizzazzjoni rigoruża hija essenzjali biex tinżamm is-sigurtà kirurġika.
Forza aggressiva żżejjed waqt l-estrazzjoni tista 'twassal għal kumplikazzjonijiet, bħal ksur tal-għadam jew ħsara fit-tessut artab. L-estrattur huwa ddisinjat għal applikazzjoni ta 'forza kkontrollata, li għandha tkun osservata b'mod strett.
L-iżgurar ta 'sekwestru sigur mad-dwiefer huwa kruċjali għal estrazzjoni sikura. Allinjament ħażin jew konnessjonijiet mhux siguri jistgħu jwasslu biex l-estrattur jiżloq, jirriskja korriment jew tneħħija tad-dwiefer mhux kompluta.
Spezzjona l-estrattur għal sinjali ta 'kedd u wettaq manutenzjoni regolari biex tiżgura prestazzjoni ottimali.
Is-suq futur għall-estratturi tad-dwiefer intramedullari huwa mistenni li jikber b'mod sinifikanti, immexxi minn żieda fil-kirurġiji ta 'reviżjoni ortopediċi, avvanzi fit-teknoloġija ta' estrazzjoni, u d-domanda għal soluzzjonijiet aktar iċċentrati fuq il-pazjent fil-kura tat-trawma.
Ir-rwol tal-estrattur fil-kirurġija ortopedika moderna huwa kruċjali, partikolarment bid-domanda dejjem tikber għat-tneħħija tal-impjant fil-popolazzjonijiet li qed jixjieħu. Hekk kif ikomplu l-avvanzi fix-xjenza materjali u t-teknoloġija kirurġika, l-estrattur tad-dwiefer intramedullarju huwa lest li jibqa 'assi ta' valur fit-trawma ortopedika u l-kirurġiji ta 'reviżjoni, li jiżgura riżultati aktar sikuri, aktar mgħaġġla u aktar effettivi għal pazjenti madwar id-dinja.
Prodotti | Stampi | Dettalji | |||
Dwiefer intramedullarju Sett ta 'Tneħħija (PN : RQSQ01) | ![]() ![]() | 1 | N-12-01 | Wrench miftuħ | 1 |
2 | N-12-02 | Wrench | 1 | ||
3 | N-12-03 | Wrench | 1 | ||
4 | N-12-04 | Estrattur Chuck φ1 (tip dritta) | 1 | ||
5 | N-12-05 | Estrattur Chuck φ2 (tip dritta) | 1 | ||
6 | N-12-06 | Estrattur Chuck φ3 (tip dritta) | 1 | ||
7 | N-12-07 | Estrattur Chuck φ4 (tip dritta) | 1 | ||
8 | N-12-08 | Estrattur Chuck φ5 (tip dritta) | 1 | ||
9 | N-12-09 | Estrattur Chuck φ6 (tip dritta) | 1 | ||
10 | N-12-10 | Estrattur Chuck φ7 (tip dritta) | 1 | ||
11 | N-12-11 | Estrattur Chuck φ8 (tip dritta) | 1 | ||
12 | N-12-12 | Estrattur Chuck φ9 (tip dritta) | 1 | ||
13 | N-12-13 | Estrattur Chuck φ10 (tip dritta) | 1 | ||
14 | N-12-14 | Estrattur Chuck φ11 (tip dritta) | 1 | ||
15 | N-12-15 | Estrattur Chuck φ12 (tip dritta) | 1 | ||
16 | N-12-16 | Estrattur Chuck φ13 (tip dritta) | 1 | ||
17 | N-12-17 | Estrattur Chuck φ10 (tip għax-xejn) | 1 | ||
18 | N-12-18 | Estrattur Chuck φ5.5 (tip ta 'għax-xejn) | 1 | ||
19 | N-12-19 | Estrattur Chuck φ4.0 (tip għax-xejn) | 1 | ||
20 | N-12-20 | Estrattur tal-kamin li jsakkar | 1 | ||
21 | N-12-21 | Tornavit Hex SW8.0 | 1 | ||
22 | N-12-22 | Tornavit Hex SW7.0 | 1 | ||
23 | N-12-23 | Tornavit Hex SW5.0 | 1 | ||
24 | N-12-24 | Tornavit Hex SW4.5 | 1 | ||
25 | N-12-25 | Tornavit Hex SW4.0 | 1 | ||
26 | N-12-26 | Tornavit Hex SW3.5 | 1 | ||
27 | N-12-27 | Tornavit Hex SW3.0 | 1 | ||
28 | N-12-28 | Tornavit Hex SW2.5 | 1 | ||
29 | N-12-29 | Martell | 1 | ||
30 | N-12-30 | L-akkoppjar ta 'malajr ta' l-akkoppjar | 1 | ||
31 | N-12-31 | Ġonta universali | 1 | ||
32 | N-12-32 | T Temp Tornavit tat-Tip T Xellug | 1 | ||
33 | N-12-33 | Typynavit Hex tat-Tip T dritt | 1 | ||
34 | N-12-34 | Rod tal-Estrattur | 1 |
It-teknoloġija tal-kontroll numeriku tal-kompjuter tintuża biex tipproċessa b'mod preċiż il-prodotti ortopediċi. Dan il-proċess għandu l-karatteristiċi ta 'preċiżjoni għolja, effiċjenza għolja, u ripetibilità. Jista 'jipproduċi malajr apparat mediku apposta li jikkonforma mal-istruttura anatomika umana u jipprovdi lill-pazjenti bi pjanijiet ta' trattament personalizzati. |
Illustrar tal-prodott L-iskop tal-illustrar tal-prodotti ortopediċi huwa li jtejjeb il-kuntatt bejn l-impjant u t-tessut uman, inaqqas il-konċentrazzjoni tal-istress, u jtejjeb l-istabbiltà fit-tul tal-impjant. |
Spezzjoni tal-kwalità It-test tal-proprjetajiet mekkaniċi tal-prodotti ortopediċi huwa ddisinjat biex jissimula l-kundizzjonijiet tal-istress tal-għadam tal-bniedem, jevalwa l-kapaċità li jġorr it-tagħbija u d-durabilità tal-impjanti fil-ġisem tal-bniedem, u jiżgura s-sigurtà u l-affidabbiltà tagħhom. |
Pakkett tal-prodott Prodotti ortopediċi huma ppakkjati f'kamra sterili biex jiżguraw li l-prodott ikun inkapsulat f'ambjent nadif u sterili biex jipprevjeni kontaminazzjoni mikrobjali u jiżgura s-sigurtà kirurġika. |
Maħżen tal-prodott Il-ħażna ta 'prodotti ortopediċi teħtieġ ġestjoni stretta u kontroll tal-kwalità biex tiżgura traċċabilità tal-prodott u tevita l-iskadenza jew il-vjeġġ ħażin. |
Kamra tal-Kampjun Il-kamra tal-kampjun tintuża biex taħżen, turi u timmaniġġja diversi kampjuni ta 'prodotti ortopediċi għal skambji u taħriġ tat-teknoloġija tal-prodott. |
1
2. Agħżel is-sett ta 'tneħħija tad-dwiefer intramedullarju interessat tiegħek.
3. Itlob kampjun biex tittestja sett ta 'tneħħija tad-dwiefer intramedullarju.
4. Agħmel ordni ta 'sett ta' tneħħija tad-dwiefer intramedullari ta 'XC Medico.
5.Become Negozjant tas-sett ta 'tneħħija tad-dwiefer intramedullari ta' XC Medico.
1. Aħjar ix-xiri tal-prezzijiet tas-sett ta 'tneħħija tad-dwiefer intramedullarju.
2.100% L-ogħla kwalità ta 'tneħħija tad-dwiefer intramedullarju.
3. Inqas sforzi li jordnaw.
4. Stabbiltà tal-prezz għall-perjodu ta 'ftehim.
5. Sett ta 'tneħħija tad-dwiefer intramedullarju suffiċjenti.
6. Valutazzjoni rapida u faċli tas-sett ta 'tneħħija tad-dwiefer intramedullari ta' XC Medico.
7. Marka rikonoxxuta globalment - xc medico.
8. Ħin ta 'aċċess mgħaġġel għat-Tim tal-Bejgħ Medico XC.
9. Test ta 'kwalità addizzjonali mit-tim Medico XC.
10. Traċċar l-ordni xc medico tiegħek mill-bidu sat-tmiem.
Il-kit ta 'tneħħija tad-dwiefer intramedullarju huwa sett ta' strumenti kirurġiċi speċjalizzati ddisinjat biex jgħin lill-kirurgi ortopediċi fl-estrazzjoni tad-dwiefer intramedullari b'mod sikur u effiċjenti minn għadam twil. Id-dwiefer intramedullari jintużaw biex jistabbilizzaw l-għadam miksur u xi kultant jitneħħew wara l-fejqan biex jiġu evitati kumplikazzjonijiet fit-tul jew skumdità. Dan il-kit jiżgura estrazzjoni kkontrollata u preċiża tal-impjant filwaqt li jimminimizza t-trawma għall-għadam tal-madwar u tessut artab.
L-għodda primarja użata biex taqbad u estratt id-dwiefer.
Użat biex iwessa 'l-kanal medullari biex jiffaċilita l-estrazzjoni tad-dwiefer.
Użat biex iħaffer il-viti tal-illokkjar, jekk preżenti.
Użat biex jitneħħew viti li jsakkru mid-dwiefer.
Użat biex jinġibed lura tessuti rotob matul il-proċedura.
L-estrattur huwa magħmul b'manki ergonomiċi, li jiżgura li l-kirurgi jistgħu jżommu qabda sigura matul il-proċedura. Dan id-disinn inaqqas l-għeja bl-idejn u jtejjeb il-kontroll, itejjeb l-effiċjenza kirurġika.
Il-mekkaniżmu tal-ikklampjar għandu jkun preċiż u affidabbli, u jiżgura qabda sigura fuq id-dwiefer.
Mibnija minn azzar tal-istainless steel kirurġiku ta 'grad għoli jew titanju, l-estrattur huwa kemm bijokompatibbli kif ukoll reżistenti għall-ilbies, materjali durabbli biex jifilħu l-forzi involuti fl-estrazzjoni tad-dwiefer , li jiżguraw li jifilħu sterilizzazzjonijiet multipli mingħajr degradazzjoni fil-kwalità.
Il-kit jinkludi diversi adapters kompatibbli ma 'disinji differenti tar-ras tad-dwiefer, li jippermettu lill-estrattur jissakkar b'mod sikur fuq diversi tipi ta' dwiefer intramedullari.
Il-kostruzzjoni robusta tal-istrument tippermetti użu ripetut, li jagħmilha għażla kosteffikaċi għall-isptarijiet u tiżgura prestazzjoni konsistenti maż-żmien.
L-estrattur huwa ddisinjat biex jippermetti estrazzjoni minimament invażiva, li tnaqqas it-trawma għat-tessuti tal-madwar u tirriżulta f'irkupru aktar malajr għall-pazjenti.
It-twaħħil sigur u l-applikazzjoni tal-forza kkontrollata tal-estrattur isaħħu s-sigurtà proċedurali, u jnaqqsu l-probabbiltà ta 'kumplikazzjonijiet bħal ksur tad-dwiefer jew ħsara fit-tessut bi żball.
L-akkoppjar malajr u l-adattabilità ta 'l-estrattur jippermettu t-tneħħija tad-dwiefer aktar mgħaġġla, jiffranka ħin siewi fil-kamra tal-operat u jippermetti lit-tim kirurġiku jaħdem b'mod aktar effiċjenti.
Billi tiffaċilita t-tneħħija tad-dwiefer bi tfixkil minimu fl-għadam, l-estrattur inaqqas l-uġigħ wara l-operazzjoni u ċ-ċans ta 'irritazzjoni residwa mill-impjant.
Il-kompatibilità tal-estrattur ma 'diversi tipi ta' dwiefer tagħmilha adattata għal firxa wiesgħa ta 'proċeduri ortopediċi, minn kirurġiji ta' trawma għal reviżjonijiet kumplessi, li tipprovdi utilità sinifikanti f'ambjenti kliniċi differenti.
Il-kirurgi għandhom jevalwaw sewwa l-kwalità tal-għadam tal-pazjent u l-istat tal-impjant qabel ma jużaw l-estrattur, bħala fatturi bħall-ingrowth tal-għadam madwar id-dwiefer jistgħu jaffettwaw il-proċess tat-tneħħija.
L-estrattur għandu jkun sterilizzat skont il-protokoll biex jipprevjeni l-infezzjoni, speċjalment minħabba l-kuntatt dirett tiegħu ma 'għadam u tessut artab. Sterilizzazzjoni rigoruża hija essenzjali biex tinżamm is-sigurtà kirurġika.
Forza aggressiva żżejjed waqt l-estrazzjoni tista 'twassal għal kumplikazzjonijiet, bħal ksur tal-għadam jew ħsara fit-tessut artab. L-estrattur huwa ddisinjat għal applikazzjoni ta 'forza kkontrollata, li għandha tkun osservata b'mod strett.
L-iżgurar ta 'sekwestru sigur mad-dwiefer huwa kruċjali għal estrazzjoni sikura. Allinjament ħażin jew konnessjonijiet mhux siguri jistgħu jwasslu biex l-estrattur jiżloq, jirriskja korriment jew tneħħija tad-dwiefer mhux kompluta.
Spezzjona l-estrattur għal sinjali ta 'kedd u wettaq manutenzjoni regolari biex tiżgura prestazzjoni ottimali.
Is-suq futur għall-estratturi tad-dwiefer intramedullari huwa mistenni li jikber b'mod sinifikanti, immexxi minn żieda fil-kirurġiji ta 'reviżjoni ortopediċi, avvanzi fit-teknoloġija ta' estrazzjoni, u d-domanda għal soluzzjonijiet aktar iċċentrati fuq il-pazjent fil-kura tat-trawma.
Ir-rwol tal-estrattur fil-kirurġija ortopedika moderna huwa kruċjali, partikolarment bid-domanda dejjem tikber għat-tneħħija tal-impjant fil-popolazzjonijiet li qed jixjieħu. Hekk kif ikomplu l-avvanzi fix-xjenza materjali u t-teknoloġija kirurġika, l-estrattur tad-dwiefer intramedullarju huwa lest li jibqa 'assi ta' valur fit-trawma ortopedika u l-kirurġiji ta 'reviżjoni, li jiżgura riżultati aktar sikuri, aktar mgħaġġla u aktar effettivi għal pazjenti madwar id-dinja.
Kuntatt