Rjsg
Xcmedico
1 komputiloj (72 horoj liveras)
Humero
Titana alojo aŭ neoksidebla ŝtalo
CE/ISO: 9001/ISO13485.ETC
Laŭmendaj 15-tagaj liverado (ekskludante sendtempon)
FedEx. Dhl.tnt.ems.etc
Havebleco: | |
---|---|
Kvanto: | |
Produktoj | Bildo | Specifaj modeloj | Specifo |
Humerus multi Ŝlosu intramedulan Ungoj | ![]() | RJSG18160R | 8,0 × 160r |
RJSG18160L | 8,0 × 160L | ||
RJSG19160R | 9,0 × 160r | ||
RJSG19160L | 9,0 × 160L | ||
RJSG17180R | 7,0 × 180 | ||
RJSG17195R | 7,0 × 195 | ||
RJSG17210R | 7,0 × 210 | ||
RJSG17225R | 7,0 × 225 | ||
RJSG17240R | 7,0 × 240 | ||
RJSG17255R | 7,0 × 255 | ||
RJSG18180R | 8,0 × 180 | ||
RJSG18195R | 8,0 × 195 | ||
RJSG18210R | 8,0 × 210 | ||
RJSG18225R | 8,0 × 225 | ||
RJSG18240R | 8,0 × 240 | ||
RJSG18255R | 8,0 × 255 | ||
RJSG17180L | 7,0 × 180 | ||
RJSG17195L | 7,0 × 195 | ||
RJSG17210L | 7,0 × 210 | ||
RJSG17225L | 7,0 × 225 | ||
RJSG17240L | 7,0 × 240 | ||
RJSG17255L | 7,0 × 255 | ||
RJSG18180L | 8,0 × 180 | ||
RJSG18195L | 8,0 × 195 | ||
RJSG18210L | 8,0 × 210 | ||
RJSG18225L | 8,0 × 225 | ||
RJSG18240L | 8,0 × 240 | ||
RJSG18255L | 8,0 × 255 | ||
Ŝraŭba nukso | ![]() | Rjsg1wm0 | 0 |
Rjsg1wm2 | 2 | ||
Rjsg1wm5 | 5 | ||
RJSG1WM10 | 10 | ||
RJSG1WM15 | 15 | ||
Ŝlosanta ŝraŭbo-i | ![]() | RJSG1LD4530 | 4,5 × 30 |
RJSG1LD4532 | 4,5 × 32 | ||
RJSG1LD4534 | 4,5 × 34 | ||
RJSG1LD4536 | 4,5 × 36 | ||
RJSG1LD4538 | 4,5 × 38 | ||
RJSG1LD4540 | 4,5 × 40 | ||
RJSG1LD4542 | 4,5 × 42 | ||
RJSG1LD4544 | 4,5 × 44 | ||
RJSG1LD4546 | 4,5 × 46 | ||
RJSG1LD4548 | 4,5 × 48 | ||
RJSG1LD4550 | 4,5 × 50 | ||
RJSG1LD4552 | 4,5 × 52 | ||
RJSG1LD4554 | 4,5 × 54 | ||
RJSG1LD4556 | 4,5 × 56 | ||
RJSG1LD4558 | 4,5 × 58 | ||
RJSG1LD4560 | 4.5 × 60 | ||
Ŝlosanta ŝraŭbo-ii | ![]() | RJSG1LD3526 | 3,5 × 26 |
RJSG1LD3528 | 3,5 × 28 | ||
RJSG1LD3530 | 3,5 × 30 | ||
RJSG1LD3532 | 3,5 × 32 | ||
RJSG1LD3534 | 3,5 × 34 | ||
RJSG1LD3536 | 3,5 × 36 | ||
RJSG1LD3538 | 3,5 × 38 | ||
RJSG1LD3540 | 3,5 × 40 | ||
RJSG1LD3542 | 3,5 × 42 | ||
RJSG1LD3544 | 3,5 × 44 | ||
RJSG1LD3546 | 3,5 × 46 | ||
RJSG1LD3548 | 3,5 × 48 | ||
RJSG1LD3550 | 3,5 × 50 | ||
Ŝlosanta ŝraŭbo-III | ![]() | RJSG1LD4018 | 4,0 × 18 |
RJSG1LD4020 | 4.0 × 20 | ||
RJSG1LD4022 | 4.0 × 22 | ||
RJSG1LD4024 | 4.0 × 24 | ||
RJSG1LD4026 | 4.0 × 26 | ||
RJSG1LD4028 | 4.0 × 28 | ||
RJSG1LD4030 | 4.0 × 30 | ||
RJSG1LD4032 | 4.0 × 32 | ||
RJSG1LD4034 | 4.0 × 34 | ||
RJSG1LD4036 | 4.0 × 36 | ||
RJSG1LD4038 | 4.0 × 38 | ||
RJSG1LD4040 | 4.0 × 40 | ||
RJSG1LD4042 | 4.0 × 42 | ||
RJSG1LD4044 | 4.0 × 44 | ||
RJSG1LD4046 | 4.0 × 46 | ||
RJSG1LD4048 | 4.0 × 48 | ||
RJSG1LD4050 | 4.0 × 50 | ||
RJSG1LD4052 | 4.0 × 52 | ||
RJSG1LD4054 | 4.0 × 54 | ||
RJSG1LD4056 | 4.0 × 56 | ||
RJSG1LD4058 | 4.0 × 58 | ||
RJSG1LD4060 | 4.0 × 60 |
1.Traight Nail Design por centra enmeta punkto.
|
CNC -antaŭparola prilaborado La komputila nombra kontrolteknologio estas uzata por precize prilabori ortopedajn produktojn. Ĉi tiu procezo havas la karakterizaĵojn de alta precizeco, alta efikeco kaj ripetebleco. Ĝi povas rapide produkti personecigitajn medicinajn aparatojn, kiuj konformas al la homa anatomia strukturo kaj provizas pacientojn kun personecaj kuracaj planoj. | Produkta Polurado La celo de ortopediaj produktoj polurado estas plibonigi la kontakton inter la enplantaĵo kaj homa histo, redukti streĉan koncentriĝon kaj plibonigi la longtempan stabilecon de la enplantaĵo. | Kvalita inspektado La testo de mekanikaj proprietoj de ortopediaj produktoj estas desegnita por simuli la streĉajn kondiĉojn de homaj ostoj, taksi la ŝarĝan kapablon kaj fortikecon de enplantaĵoj en la homa korpo kaj certigi ilian sekurecon kaj fidindecon. |
Produkta Pako Ortopedaj produktoj estas enpakitaj en senfrukta ĉambro por certigi, ke la produkto estas enkapsuligita en pura, senfrukta medio por malebligi mikrobian poluadon kaj certigi kirurgian sekurecon. |
La stokado de ortopediaj produktoj postulas striktan en-kaj-ekster-administradan kaj kvalitan kontrolon por certigi produkteblecon de produktoj kaj malhelpi finiĝon aŭ malĝustan sendon. |
La ekzempla ĉambro estas uzata por stoki, aperigi kaj administri diversajn ortopedajn produktajn specimenojn por produktaj teknologiaj interŝanĝoj kaj trejnado. |
1. Demandu XC Medico-Teamon pri plur-seruro Humerus Intramedullary Nail Product Catalog.
2. Elektu vian interesatan multi-ŝlosan humeron-intramedulan najlan produkton.
3. Petu specimenon por testi multi-ŝlositan humeron intramedulan najlon.
4. Faru ordon de la mult-serva humero de XC Medico-humero intramedulara.
5.Komu komerciston de la mult-ŝlosita humero-intramedulara najlo de XC Medico.
1. Pli bonaj aĉetaj prezoj de plur-seruro humero intramedulara najlo.
2.100% la plej altkvalita plur-seruro humero intramedulara najlo.
3. Malpli ordonaj klopodoj.
4. Prezo -stabileco por la periodo de interkonsento.
5.
6. Rapida kaj facila takso de la mult-seruro de XC Medico-humero intramedulara najlo.
7. Tutmonde rekonita marko - XC Medico.
8. Rapida alira tempo al XC Medico -venda teamo.
9. Plia kvalita testo de XC Medico -teamo.
10. Spuru vian XC Medico -mendon de komenco ĝis fino.
La Humerus Multi-Lock Intramedullary Nail estas kirurgia enplantaĵo desegnita por stabiligi frakturojn de la humera osto en la supra brako. Ĝi estas longa, svelta vergo farita el titanio aŭ neoksidebla ŝtalo, kiu estas enmetita en la medulan kavon de la humero. La najlo estas sekurigita anstataŭe per ŝlosaj ŝraŭboj, kiuj estas enmetitaj en la oston kaj la najlon mem.
La najlo inkluzivas plurajn proksimajn kaj distalajn ŝlosilajn punktojn, kiuj provizas sekuran fiksadon. Ĉi tiu funkcio permesas flekseblecon en uzado de diversaj frakturaj tipoj, inkluzive de transversaj, oblikvaj, kaj komintaj frakturoj.
Kun ergonomia dezajno, kiu faciligas facilecon de enmeto kaj poziciigado, la najlo reduktas kirurgian tempon kaj ebligas precizan vicigon kun minimumaj alĝustigoj.
Konstruita el altgrada titanio, la najlo estas malpeza, korod-rezistema kaj biocompatible, farita el biocompatibles materialoj bone toleritaj de la korpo, reduktante la riskon de postoperaciaj komplikaĵoj kaj certigante longecon.
Reduktas la riskon de histo -kolero kaj infekto.
La mult-ŝlosila sistemo disponigas plibonigitan stabilecon, reduktante la riskon de rotacia nestabileco kaj certigante sekuran fraktur-fiksadon, precipe utilan en kominitaj frakturoj.
Ĝia minimume invasiva naturo reduktas molan histan interrompon, rezultigante malpli post-operacian doloron, pli malaltan infektan riskon kaj pli rapidan resaniĝon por pacientoj.
Pacientoj ofte reakiras moveblecon pli frue pro la ŝarĝ-interŝanĝaj kapabloj de la najlo, kiuj subtenas fruan pezon, esencan por redukti komplikaĵojn asociitajn kun plilongigita senmovigo.
Ĝia kongruo kun malsamaj frakturaj ŝablonoj kaj humeraj anatomioj igas ĝin vershava elekto por traŭmaj kirurgoj, certigante altajn sukcesajn indicojn tra gamo da kazoj.
Inkluzive de detala medicina historio, fizika ekzameno, bildiga ekzameno (radiografio, CT, ktp.) Por taksi la tipon kaj gradon de frakturo kaj la kondiĉon ĉirkaŭi molan histon.
Laŭ la bildigaj datumoj, detala kirurgia plano estas formulita, inkluzive de la elekto de alproksimiĝo, intramedulara najla modelo, nombro kaj pozicio de ŝlosaj ŝraŭboj, ktp.
Brachial plexus -bloko aŭ ĝenerala anestezio estas kutime uzataj.
Ĉi tiu estas la plej ofte uzata aliro, per la incizo sur la antaŭa deltoida muskolo, la dekstra humero estas elmontrita.
Por iuj specialaj frakturtipoj, aliaj aliroj povas esti bezonataj, kiel la subkoracoida aliro.
Sub la gvido de C-brako X-radia maŝino, la frakturitaj ostaj fragmentoj estas reduktitaj al la anatomia pozicio per manipulado aŭ helpe de instrumentoj.
Por kompleksaj frakturoj, malferma redukto povas esti bezonata per malgranda incizo.
La medula kavo estas iom post iom pligrandigita uzante medulan kavan ekspansion por akomodi la diametron de la intramedula najlo.
Sub la gvido de la X-radia maŝino C-brako, la gvida nadlo estas enmetita en la medulan kavon de la humera kapo aŭ pli granda tuberoseco ĝis la distala fino de la frakturo.
Enmetu la intramedulan najlon laŭ la gvida nadlo ĝis ĝi atingos la antaŭdifinitan pozicion.
Sub la gvido de la X-radia maŝino C-brako, truo estas borita ĉe la humera kapo aŭ pli granda tuberoseco tra speciala borado, kaj tiam enŝlosita ŝraŭbo estas enmetita.
Borigu truon ĉe la distala fino de la frakturo kaj enmetu ŝlosan ŝraŭbon.
Ŝraŭba Plifortikigo: La nombro de ŝlosilaj ŝraŭboj povas esti pliigita laŭ la tipo kaj stabileco de la frakturo.
Post ĝisfunda hemostazo, la mola histo estas fermita tavolo per tavolo.
Metu kloakan tubon se necese.
Bandaĝi la vundon kun senfrukta pansaĵo.
Post kirurgio, la tuŝita limbo kutime devas esti fiksita sur triangula bandaĝo aŭ uzi ŝultran krampon.
Funkciaj ekzercoj de la ŝultra artiko estas komencitaj frue post kirurgio por malebligi kunan rigidecon.
Por malebligi infekton, antibiotikoj estas donitaj post kirurgio.
Regula sekvado por monitori resanigon de frakturo.
Kvankam malofta, najla migrado povas okazi se ne sekure ŝlosita, do kirurgoj devas kontroli, ke ĉiuj ŝlosilpunktoj estas ĝuste engaĝitaj dum kirurgio.
Ĝustaj steriligaj protokoloj devas esti sekvataj rigore por malebligi post-operaciajn infektojn, precipe konsiderante la minimume invasan naturon de la proceduro.
Uzi kontrolitan forton dum enmeto helpas malhelpi ostan ŝprucadon aŭ troan plilarĝigon de la kanalo, kio povus konduki al komplikaĵoj aŭ prokrastita resanigo.
NSAIDoj kaj aliaj doloroj estas ofte uzataj por administri post-operacian doloron, kun pliaj terapioj laŭ bezono por certigi komforton de pacientoj.
Kontrolita fizika terapio povas esti enkondukita post 4-6 semajnoj por restarigi muskolan forton, flekseblecon kaj gamon de moviĝo, helpante la pacienton reakiri normalan brakan funkcion.
Oni konsilas pacientojn atenti signojn de infekto ĉe la inciza loko, kiel ruĝeco aŭ ŝvelaĵo, kaj sekvi regulajn kontrolojn.
Regula bildigo estas farata por spuri resanigon de osto kaj certigi, ke la najlo restu en la ĝusta pozicio, kio estas kerna por sukcesa resaniĝo.
La templinio por reveno al normalaj agadoj varias depende de la specifa frakturo, individua resaniga rapideco kaj kirurgia proceduro. Necesas sekvi la konsilon de via kirurgo kaj eviti troan fizikan aktivecon dum la komenca resaniga fazo. Ĉar la osto resanigas, vi povas iom post iom pliigi vian agadnivelon, inkluzive de milda gamo de movaj ekzercoj kaj fortigaj ekzercoj.
La estonta merkato de Humerus Multi-Lock Intramedullary Nails kreskos, antaŭenpuŝita de progresoj en ortopediaj teknologioj, pliigante postulon pri minimume invasivaj solvoj kaj ekspansio en emerĝaj merkatoj.
Humerus Multi-Lock Intramedullary Nails estas efikaj kirurgiaj enplantaĵoj por stabiligi humerus-frakturojn. Ili ofertas plurajn avantaĝojn, inkluzive de minimuma invado, pli rapida resanigo, kaj plibonigitaj funkciaj rezultoj. Tamen gravas kompreni la eblajn riskojn kaj komplikaĵojn ligitajn al ĉi tiu proceduro. Sekvante taŭgajn kirurgiajn teknikojn kaj postoperacian prizorgadon, pacientoj povas atingi optimuman resanigon kaj resaniĝon.
Varma Rememoro: Ĉi tiu artikolo estas nur por referenco kaj ne povas anstataŭigi la profesian konsilon de la kuracisto. Se vi havas demandojn, bonvolu konsulti vian ĉeestantan kuraciston.
Produktoj | Bildo | Specifaj modeloj | Specifo |
Humerus multi Ŝlosu intramedulan Ungoj | ![]() | RJSG18160R | 8,0 × 160r |
RJSG18160L | 8,0 × 160L | ||
RJSG19160R | 9,0 × 160r | ||
RJSG19160L | 9,0 × 160L | ||
RJSG17180R | 7,0 × 180 | ||
RJSG17195R | 7,0 × 195 | ||
RJSG17210R | 7,0 × 210 | ||
RJSG17225R | 7,0 × 225 | ||
RJSG17240R | 7,0 × 240 | ||
RJSG17255R | 7,0 × 255 | ||
RJSG18180R | 8,0 × 180 | ||
RJSG18195R | 8,0 × 195 | ||
RJSG18210R | 8,0 × 210 | ||
RJSG18225R | 8,0 × 225 | ||
RJSG18240R | 8,0 × 240 | ||
RJSG18255R | 8,0 × 255 | ||
RJSG17180L | 7,0 × 180 | ||
RJSG17195L | 7,0 × 195 | ||
RJSG17210L | 7,0 × 210 | ||
RJSG17225L | 7,0 × 225 | ||
RJSG17240L | 7,0 × 240 | ||
RJSG17255L | 7,0 × 255 | ||
RJSG18180L | 8,0 × 180 | ||
RJSG18195L | 8,0 × 195 | ||
RJSG18210L | 8,0 × 210 | ||
RJSG18225L | 8,0 × 225 | ||
RJSG18240L | 8,0 × 240 | ||
RJSG18255L | 8,0 × 255 | ||
Ŝraŭba nukso | ![]() | Rjsg1wm0 | 0 |
Rjsg1wm2 | 2 | ||
Rjsg1wm5 | 5 | ||
RJSG1WM10 | 10 | ||
RJSG1WM15 | 15 | ||
Ŝlosanta ŝraŭbo-i | ![]() | RJSG1LD4530 | 4,5 × 30 |
RJSG1LD4532 | 4,5 × 32 | ||
RJSG1LD4534 | 4,5 × 34 | ||
RJSG1LD4536 | 4,5 × 36 | ||
RJSG1LD4538 | 4,5 × 38 | ||
RJSG1LD4540 | 4,5 × 40 | ||
RJSG1LD4542 | 4,5 × 42 | ||
RJSG1LD4544 | 4,5 × 44 | ||
RJSG1LD4546 | 4,5 × 46 | ||
RJSG1LD4548 | 4,5 × 48 | ||
RJSG1LD4550 | 4,5 × 50 | ||
RJSG1LD4552 | 4,5 × 52 | ||
RJSG1LD4554 | 4,5 × 54 | ||
RJSG1LD4556 | 4,5 × 56 | ||
RJSG1LD4558 | 4,5 × 58 | ||
RJSG1LD4560 | 4.5 × 60 | ||
Ŝlosanta ŝraŭbo-ii | ![]() | RJSG1LD3526 | 3,5 × 26 |
RJSG1LD3528 | 3,5 × 28 | ||
RJSG1LD3530 | 3,5 × 30 | ||
RJSG1LD3532 | 3,5 × 32 | ||
RJSG1LD3534 | 3,5 × 34 | ||
RJSG1LD3536 | 3,5 × 36 | ||
RJSG1LD3538 | 3,5 × 38 | ||
RJSG1LD3540 | 3,5 × 40 | ||
RJSG1LD3542 | 3,5 × 42 | ||
RJSG1LD3544 | 3,5 × 44 | ||
RJSG1LD3546 | 3,5 × 46 | ||
RJSG1LD3548 | 3,5 × 48 | ||
RJSG1LD3550 | 3,5 × 50 | ||
Ŝlosanta ŝraŭbo-III | ![]() | RJSG1LD4018 | 4,0 × 18 |
RJSG1LD4020 | 4.0 × 20 | ||
RJSG1LD4022 | 4.0 × 22 | ||
RJSG1LD4024 | 4.0 × 24 | ||
RJSG1LD4026 | 4.0 × 26 | ||
RJSG1LD4028 | 4.0 × 28 | ||
RJSG1LD4030 | 4.0 × 30 | ||
RJSG1LD4032 | 4.0 × 32 | ||
RJSG1LD4034 | 4.0 × 34 | ||
RJSG1LD4036 | 4.0 × 36 | ||
RJSG1LD4038 | 4.0 × 38 | ||
RJSG1LD4040 | 4.0 × 40 | ||
RJSG1LD4042 | 4.0 × 42 | ||
RJSG1LD4044 | 4.0 × 44 | ||
RJSG1LD4046 | 4.0 × 46 | ||
RJSG1LD4048 | 4.0 × 48 | ||
RJSG1LD4050 | 4.0 × 50 | ||
RJSG1LD4052 | 4.0 × 52 | ||
RJSG1LD4054 | 4.0 × 54 | ||
RJSG1LD4056 | 4.0 × 56 | ||
RJSG1LD4058 | 4.0 × 58 | ||
RJSG1LD4060 | 4.0 × 60 |
1.Traight Nail Design por centra enmeta punkto.
|
CNC -antaŭparola prilaborado La komputila nombra kontrolteknologio estas uzata por precize prilabori ortopedajn produktojn. Ĉi tiu procezo havas la karakterizaĵojn de alta precizeco, alta efikeco kaj ripetebleco. Ĝi povas rapide produkti personecigitajn medicinajn aparatojn, kiuj konformas al la homa anatomia strukturo kaj provizas pacientojn kun personecaj kuracaj planoj. | Produkta Polurado La celo de ortopediaj produktoj polurado estas plibonigi la kontakton inter la enplantaĵo kaj homa histo, redukti streĉan koncentriĝon kaj plibonigi la longtempan stabilecon de la enplantaĵo. | Kvalita inspektado La testo de mekanikaj proprietoj de ortopediaj produktoj estas desegnita por simuli la streĉajn kondiĉojn de homaj ostoj, taksi la ŝarĝan kapablon kaj fortikecon de enplantaĵoj en la homa korpo kaj certigi ilian sekurecon kaj fidindecon. |
Produkta Pako Ortopedaj produktoj estas enpakitaj en senfrukta ĉambro por certigi, ke la produkto estas enkapsuligita en pura, senfrukta medio por malebligi mikrobian poluadon kaj certigi kirurgian sekurecon. |
La stokado de ortopediaj produktoj postulas striktan en-kaj-ekster-administradan kaj kvalitan kontrolon por certigi produkteblecon de produktoj kaj malhelpi finiĝon aŭ malĝustan sendon. |
La ekzempla ĉambro estas uzata por stoki, aperigi kaj administri diversajn ortopedajn produktajn specimenojn por produktaj teknologiaj interŝanĝoj kaj trejnado. |
1. Demandu XC Medico-Teamon pri plur-seruro Humerus Intramedullary Nail Product Catalog.
2. Elektu vian interesatan multi-ŝlosan humeron-intramedulan najlan produkton.
3. Petu specimenon por testi multi-ŝlositan humeron intramedulan najlon.
4. Faru ordon de la mult-serva humero de XC Medico-humero intramedulara.
5.Komu komerciston de la mult-ŝlosita humero-intramedulara najlo de XC Medico.
1. Pli bonaj aĉetaj prezoj de plur-seruro humero intramedulara najlo.
2.100% la plej altkvalita plur-seruro humero intramedulara najlo.
3. Malpli ordonaj klopodoj.
4. Prezo -stabileco por la periodo de interkonsento.
5.
6. Rapida kaj facila takso de la mult-seruro de XC Medico-humero intramedulara najlo.
7. Tutmonde rekonita marko - XC Medico.
8. Rapida alira tempo al XC Medico -venda teamo.
9. Plia kvalita testo de XC Medico -teamo.
10. Spuru vian XC Medico -mendon de komenco ĝis fino.
La Humerus Multi-Lock Intramedullary Nail estas kirurgia enplantaĵo desegnita por stabiligi frakturojn de la humera osto en la supra brako. Ĝi estas longa, svelta vergo farita el titanio aŭ neoksidebla ŝtalo, kiu estas enmetita en la medulan kavon de la humero. La najlo estas sekurigita anstataŭe per ŝlosaj ŝraŭboj, kiuj estas enmetitaj en la oston kaj la najlon mem.
La najlo inkluzivas plurajn proksimajn kaj distalajn ŝlosilajn punktojn, kiuj provizas sekuran fiksadon. Ĉi tiu funkcio permesas flekseblecon en uzado de diversaj frakturaj tipoj, inkluzive de transversaj, oblikvaj, kaj komintaj frakturoj.
Kun ergonomia dezajno, kiu faciligas facilecon de enmeto kaj poziciigado, la najlo reduktas kirurgian tempon kaj ebligas precizan vicigon kun minimumaj alĝustigoj.
Konstruita el altgrada titanio, la najlo estas malpeza, korod-rezistema kaj biocompatible, farita el biocompatibles materialoj bone toleritaj de la korpo, reduktante la riskon de postoperaciaj komplikaĵoj kaj certigante longecon.
Reduktas la riskon de histo -kolero kaj infekto.
La mult-ŝlosila sistemo disponigas plibonigitan stabilecon, reduktante la riskon de rotacia nestabileco kaj certigante sekuran fraktur-fiksadon, precipe utilan en kominitaj frakturoj.
Ĝia minimume invasiva naturo reduktas molan histan interrompon, rezultigante malpli post-operacian doloron, pli malaltan infektan riskon kaj pli rapidan resaniĝon por pacientoj.
Pacientoj ofte reakiras moveblecon pli frue pro la ŝarĝ-interŝanĝaj kapabloj de la najlo, kiuj subtenas fruan pezon, esencan por redukti komplikaĵojn asociitajn kun plilongigita senmovigo.
Ĝia kongruo kun malsamaj frakturaj ŝablonoj kaj humeraj anatomioj igas ĝin vershava elekto por traŭmaj kirurgoj, certigante altajn sukcesajn indicojn tra gamo da kazoj.
Inkluzive de detala medicina historio, fizika ekzameno, bildiga ekzameno (radiografio, CT, ktp.) Por taksi la tipon kaj gradon de frakturo kaj la kondiĉon ĉirkaŭi molan histon.
Laŭ la bildigaj datumoj, detala kirurgia plano estas formulita, inkluzive de la elekto de alproksimiĝo, intramedulara najla modelo, nombro kaj pozicio de ŝlosaj ŝraŭboj, ktp.
Brachial plexus -bloko aŭ ĝenerala anestezio estas kutime uzataj.
Ĉi tiu estas la plej ofte uzata aliro, per la incizo sur la antaŭa deltoida muskolo, la dekstra humero estas elmontrita.
Por iuj specialaj frakturtipoj, aliaj aliroj povas esti bezonataj, kiel la subkoracoida aliro.
Sub la gvido de C-brako X-radia maŝino, la frakturitaj ostaj fragmentoj estas reduktitaj al la anatomia pozicio per manipulado aŭ helpe de instrumentoj.
Por kompleksaj frakturoj, malferma redukto povas esti bezonata per malgranda incizo.
La medula kavo estas iom post iom pligrandigita uzante medulan kavan ekspansion por akomodi la diametron de la intramedula najlo.
Sub la gvido de la X-radia maŝino C-brako, la gvida nadlo estas enmetita en la medulan kavon de la humera kapo aŭ pli granda tuberoseco ĝis la distala fino de la frakturo.
Enmetu la intramedulan najlon laŭ la gvida nadlo ĝis ĝi atingos la antaŭdifinitan pozicion.
Sub la gvido de la X-radia maŝino C-brako, truo estas borita ĉe la humera kapo aŭ pli granda tuberoseco tra speciala borado, kaj tiam enŝlosita ŝraŭbo estas enmetita.
Borigu truon ĉe la distala fino de la frakturo kaj enmetu ŝlosan ŝraŭbon.
Ŝraŭba Plifortikigo: La nombro de ŝlosilaj ŝraŭboj povas esti pliigita laŭ la tipo kaj stabileco de la frakturo.
Post ĝisfunda hemostazo, la mola histo estas fermita tavolo per tavolo.
Metu kloakan tubon se necese.
Bandaĝi la vundon kun senfrukta pansaĵo.
Post kirurgio, la tuŝita limbo kutime devas esti fiksita sur triangula bandaĝo aŭ uzi ŝultran krampon.
Funkciaj ekzercoj de la ŝultra artiko estas komencitaj frue post kirurgio por malebligi kunan rigidecon.
Por malebligi infekton, antibiotikoj estas donitaj post kirurgio.
Regula sekvado por monitori resanigon de frakturo.
Kvankam malofta, najla migrado povas okazi se ne sekure ŝlosita, do kirurgoj devas kontroli, ke ĉiuj ŝlosilpunktoj estas ĝuste engaĝitaj dum kirurgio.
Ĝustaj steriligaj protokoloj devas esti sekvataj rigore por malebligi post-operaciajn infektojn, precipe konsiderante la minimume invasan naturon de la proceduro.
Uzi kontrolitan forton dum enmeto helpas malhelpi ostan ŝprucadon aŭ troan plilarĝigon de la kanalo, kio povus konduki al komplikaĵoj aŭ prokrastita resanigo.
NSAIDoj kaj aliaj doloroj estas ofte uzataj por administri post-operacian doloron, kun pliaj terapioj laŭ bezono por certigi komforton de pacientoj.
Kontrolita fizika terapio povas esti enkondukita post 4-6 semajnoj por restarigi muskolan forton, flekseblecon kaj gamon de moviĝo, helpante la pacienton reakiri normalan brakan funkcion.
Oni konsilas pacientojn atenti signojn de infekto ĉe la inciza loko, kiel ruĝeco aŭ ŝvelaĵo, kaj sekvi regulajn kontrolojn.
Regula bildigo estas farata por spuri resanigon de osto kaj certigi, ke la najlo restu en la ĝusta pozicio, kio estas kerna por sukcesa resaniĝo.
La templinio por reveno al normalaj agadoj varias depende de la specifa frakturo, individua resaniga rapideco kaj kirurgia proceduro. Necesas sekvi la konsilon de via kirurgo kaj eviti troan fizikan aktivecon dum la komenca resaniga fazo. Ĉar la osto resanigas, vi povas iom post iom pliigi vian agadnivelon, inkluzive de milda gamo de movaj ekzercoj kaj fortigaj ekzercoj.
La estonta merkato de Humerus Multi-Lock Intramedullary Nails kreskos, antaŭenpuŝita de progresoj en ortopediaj teknologioj, pliigante postulon pri minimume invasivaj solvoj kaj ekspansio en emerĝaj merkatoj.
Humerus Multi-Lock Intramedullary Nails estas efikaj kirurgiaj enplantaĵoj por stabiligi humerus-frakturojn. Ili ofertas plurajn avantaĝojn, inkluzive de minimuma invado, pli rapida resanigo, kaj plibonigitaj funkciaj rezultoj. Tamen gravas kompreni la eblajn riskojn kaj komplikaĵojn ligitajn al ĉi tiu proceduro. Sekvante taŭgajn kirurgiajn teknikojn kaj postoperacian prizorgadon, pacientoj povas atingi optimuman resanigon kaj resaniĝon.
Varma Rememoro: Ĉi tiu artikolo estas nur por referenco kaj ne povas anstataŭigi la profesian konsilon de la kuracisto. Se vi havas demandojn, bonvolu konsulti vian ĉeestantan kuraciston.
Kontakto