RP1H a ni
XCmedico a ni
Maxillofacial a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Hming | Milem | Item No. | A sawifiahna |
| 1.5 Maxillofacial Micro Double Locking Y-Plate hmanga siam a ni | ![]() |
RP1HS617SY1 a ni | 6 a awm a, 0.6mm, 17mm a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team hnenah 1.5 Maxillofacial Micro Double Locking Y-Plate Product Catalog dil rawh.
2. I duhzawng 1.5 Maxillofacial Micro Double Locking Y-Plate Product thlang rawh.
3. Test turin Sample Dil rawh 1.5 Maxillofacial Micro Double Locking Y-Plate.
4.XC Medico-in 1.5 Maxillofacial Micro Double Locking Y-Plate a siam chu Order siam rawh.
5.XC Medico-a 1.5 Maxillofacial Micro Double Locking Y-Plate Dealer ni rawh.
1.Maxillofacial Micro Double Locking Y-Plate 1.5 lei man tha zawk.
2.100% Quality sang ber 1.5 Maxillofacial Micro Double Locking Y-Plate hmanga siam a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. 1.5 Maxillofacial Micro Double Locking Y-Plate a tling.
6. XC Medico-in 1.5 Maxillofacial Micro Double Locking Y-Plate a siam chu rang leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
1.5 Maxillofacial Micro Double Locking Y-Plate hi implant thiam tak a ni a, maxillofacial region-a fracture leh defect awmte fixation leh stabilization atana siam a ni. A design thar, double Y-shaped design, locking screw mechanism nena inzawm hian complex fracture case tan solution rintlak tak a ni a, anatomical alignment dik tak leh stability tihchakna a pe a ni. He guide kimchang tak hian 1.5 Maxillofacial Micro Double Locking Y-Plate features, advantages, applications, risks, leh nakin lawka market trends te a zirchiang a, surgeon, researcher leh medical professional te tan chipchiar taka thlirletna a pe a ni.
1.5 Maxillofacial Micro Double Locking Y-Plate hi implant te tak te, rit lo tak a ni a, maxillofacial region-a fracture awmte stabilization atan hman a ni a, mandible, zygomatic arch leh orbital floor te pawh a tel a ni. '1.5' hian plate chu screw 1.5mm diameter nena inmil a nih thu a tarlang a, hei hian anatomical region nalh leh buaithlak tak takah hman atan a tha hle.
Double Y-shaped design hian fixation option hrang hrang a pe a, fracture fragment tam tak chu precise alignment a siam thei a ni. A locking screw mechanism hian screw te chu plate-ah nghet takin a awm reng a, hei hian a dam laiin a lo chhuah emaw, a inthlak emaw theihna a ti tlem a ni. Titanium emaw stainless steel emaw ang chi biocompatible material hmanga siam niin, plate hian a chhe thei lo a, a him a, hun rei tak chhung a thawk thei bawk.
Plate configuration danglam tak hian fixation option tihchangtlun nan dual arms a pe a, hei hian anatomically complex area-a fracture te chu precise stabilization a siam thei a ni.
Screw te hi plate chhungah nghet takin an lock a, rigid construct a siam a, micromotion a ti tlem a, fracture healing a tichak bawk.
Ruh te tak te, nalh tak takah hman tur atana duan a ni a, plate micro size hian hardware bulk tlem ber a siam a, damlote hrehawmna leh soft tissue irritation a ti tlem a ni.
Strategically placed holes hian screw placement a ti tha a, secure fixation a siam thei a, surgical time pawh a ti tlem bawk.
High-grade titanium emaw stainless steel atanga siam niin, he plate hian biocompatibility tha tak, corrosion resistance leh mechanical strength a pe a ni.
Surgery neih laiin plate hi damlo taksa peng hrang hrangte nena inmil turin contoured theih a ni a, chu chuan a fit dik leh him a ni.
A low-profile design hian hardware hmuh theihna emaw, irritation emaw a tih tlem avangin aesthetics pawimawhna hmuna procedure atan a tha hle.
Locking mechanism hian screw te chu plate-ah nghet taka anchor reng theih nan a enkawl a, hun kal zelah a loose emaw migration emaw a ti tlem a ni.
Double Y-shaped design hian multi-point fixation a siam thei a, ruh chi hrang hrangte chu a dik taka alignment theih a ni a, malunion awm theihna a ti tlem bawk.
Plate design compact leh low-profile hian soft tissue tihbuai a ti tlem a, hei hian a dam chak zawk a, postoperative complication a ti tlem bawk.
Fracture chi hrang hrang leh anatomical region hrang hrang tan a tha a, plate design hian thil awlsam leh buaithlak takah pawh a hmang thei a ni.
Design hniam leh rit lo tak hian hardware hmuh theihna a ti tlem a, hmai ang chi hmunah aesthetic result tha zawk a siam thei a ni.
Thil chakna sang tak hmanga siam niin, plate hian performance rintlak tak a pe a, stress sang tak awmna hmunah emaw, hun rei tak hman lai pawhin a thawk thei a ni.
Plate-a pre-drilled holes leh ergonomic design hian surgical process a ti awlsam a, operation hun a tihtlem bakah overall outcome a ti tha hle.
Plate hian mandibular angle, taksa leh symphysis-a fracture te stabilize-na kawngah a thawk tha hle a, heng high-stress area-ah te hian support nghet tak a pe a ni.
A double Y design danglam tak hi zygomatic bone-a fracture tan a tha hle a, precise alignment a siam thei a, facial symmetry a siam tha leh thei bawk.
Plate hi a compact size leh versatility a nih avangin orbital rim emaw floor emaw a fractures stabilize nan duhthlanna tha tak a ni a, ocular function leh aesthetic outcomes te a humhim thei bawk.
Le Fort emaw, mid-facial fracture dang emaw a awm chuan plate hian stabilization rintlak tak a pe a, anatomical reconstruction pawh a support bawk.
Fragment tam tak awmna fracture tan chuan double Y design hian fragment tinte chu secure fixation a siam thei a, hei hian displacement risk a ti tlem a, efficient healing a tichak bawk.
Plate te hi a te a, a invasive lo hle a, naupangte hman atan a tha hle a, chutah chuan ruh nalh tak takte chu chiang tak leh uluk taka enkawl a ngai a ni.
Surgery dang ang bawkin implant hmunah hian natna kai theihna a awm. Hetiang hlauhawmna tihziaawm nan hian sterilization dik leh postoperative care a pawimawh hle.
A tlem hle nachungin, dah dik loh emaw, mechanical stress tam lutuk emaw chuan plate migration a thlen thei a, revision surgery neih a ngai a ni.
Hmai nerve te a inhnaih em avangin operation neih laiin nerve a chhiat theihna a awm a, sensory emaw motor deficit emaw a thlen thei bawk.
Ruh quality tha lo, infection, emaw fixation tha lo ang chi thilte hian ruh ruh chu a dam tlai emaw, nonunion emaw a thlen thei a ni.
A awm lo nain, damlo thenkhat chuan plate-a metallic components-te chu allergy an nei thei a ni.
Contoured tha tak a nih loh chuan vun hnuaiah plate chu a langsar thei a, chu chuan a ti hrehawm thei a, aesthetic concerns a siam thei bawk.
Kawngpuiah accident, infiamna lama hliam, leh tharum thawhna avanga trauma pung zel hian advanced maxillofacial implants mamawhna a tipung a ni.
Implant material leh design lama thil thar siam chhuah hian plate performance leh versatility a tichak a, a hmanna pawh a tizau thei dawn niin an sawi.
Khawvel mihring pun chak chhoh zel chuan ruh natna leh degenerative condition dangte nena inzawm fracture hluar zel hian fixation device rintlak mamawhna a tipung dawn a ni.
Ram thang mektea healthcare infrastructure tihpun hian 1.5 Maxillofacial Micro Double Locking Y-Plate ang chi surgical implant hmasawn tak takte hman a tichak dawn niin an sawi.
Maxillofacial surgery-a functional leh cosmetic result pahnih neih theihna tura ngaih pawimawh zual zel hian low-profile, anatomically designed implants te chu a lar zel dawn a ni.
1.5 Maxillofacial Micro Double Locking Y-Plate hi implant specialized tak a ni a, maxillofacial region-a fracture leh defects enkawlna atan stability, precision leh durability danglam tak a pe a ni. A double Y design danglam tak, locking mechanism, leh biocompatible construction te hian fixation tha zawk a siam a, complication a ti tlem a, aesthetic outcomes a ti tha zawk bawk. Risk ṭhenkhat a awm laiin, he implant ṭhatna hian harsatna a tluk phah hle a, khawvel puma maxillofacial surgeon-te tan chuan duhthlanna rintlak tak a ni. Surgical implant hmasawn mamawhna a san chhoh zel avang leh implant technology lama thil thar chhuah chhunzawm zel a nih avangin 1.5 Maxillofacial Micro Double Locking Y-Plate hi tunlai maxillofacial trauma leh reconstruction management-a hmanraw pawimawh tak a ni chhunzawm zel dawn a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp