RP1H a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Hming | Milem | Item no. | Specification 100 a ni. |
1.5 Maxillofacial Micro locking chu a rawn thleng ta a ni. | ![]() |
RP1HS420J1000 a ni. | 4 holes, 0.6mm, 20mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties tes |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 1.5 maxillofacial micro locking straight bridge plate product catalog a awm theih nan zawt rawh.
2. I duh duh thlang rawh 1.5 maxillofacial micro locking straight bridge plate product.
3. 1.5 maxillofacial micro locking straight bridge plate test turin sample dil rawh.
4.A order chu XC Medico-a 1.5 maxillofacial micro locking straight bridge plate.
5.XC Medico-a 1.5 maxillofacial micro locking straight bridge plate-a dealer ni rawh.
1.A lei man tha zawk 1.5 Maxillofacial micro locking straight bridge plate.
2.100% A quality sang ber 1.5 Maxillofacial micro locking straight bridge plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tling tawk 1.5 maxillofacial micro locking straight bridge plate.
6. XC Medico-a 1.5 maxillofacial micro locking straight bridge plate-a thil tih dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Maxillofacial fractures hian functional recovery leh aesthetic restoration pahnih a neih theih nan tailored leh precise approach a mamawh a ni. 1.5 Maxillofacial Micro Locking Straight Bridge Plate hi implant hmasawn tak a ni a, hmai structure nalh tak takte tihngheh a nih theihna tura harsatna danglam bikte hmachhawn tura siam a ni. He guide hian a lan dan, a hlawkna, a hman dan, a hlauhawmna, leh a hmalam hun atana a theihnate chipchiar taka a zir chianna a pe a ni.
1.5 maxillofacial micro locking straight bridge plate hi specialized orthopedic implant engineered a ni a, maxillofacial region-a fracture tenau leh inthup tak takte tan stable fixation a pe thei a ni. A straight bridge design hian complex fracture pattern hrang hrangah versatile application a siam thei a, ruh dam laiin alignment dik tak leh rintlak taka support a awm theih phah a ni. Material hmasawn leh engineering technique hmanga siam a ni a, tunlai maxillofacial surgery-a thil phut a phuhruk a ni.
Screw te chu plate chhungah nghet takin a lock a, chu chuan stable fixation a awm theih nan leh a lo chhuahna tur a tihziaawm theih nan.
Fracture chi hrang hrang leh anatomical configuration hrang hrang tan adaptability a pe.
Titanium emaw titanium alloy atanga siam a nih avangin tissue inmilna tha tak leh corrosion laka inven theihna a siam tha hle.
Soft tissue irritation a ti tlem a, postoperative comfort a tichak bawk.
Intraoperative adjustment mamawhna a ti tlem a, surgical workflows a ti awlsam bawk.
Interference awm lovin postoperative imaging chiang tak a siam thei a, follow-up dik tak a siamsak thei bawk.
ruh tliakte chu a nghetin a nghet thei a, damna tha leh rintlak tak a siam thei bawk.
Pre-contoured design leh hman awlsamna features te hian surgical efficiency a ti tha hle.
Low-profile structure hian postoperative discomfort leh hardware lakchhuah a ngaihna a ti tlem hle.
Maxillofacial fracture hrang hrang tan a tha a, naupang leh comminuted case te pawh a tel.
Biomechanical stress tuar thei tura duan, hun rei tak chhunga dinhmun nghet leh rintlakna pe thei.
Symphysis, parasymphysis, leh angle fractures atan a tha hle.
Zygomatic leh maxillary fractures te tan stabilization a pe bawk.
Orbital floor leh rim hmanga hliam tuar te tan fixation dik tak a siamsak.
Le fort I, II, leh III fracture pattern complex tak tak enkawlna atan a tha.
Compact design hian naupangte anatomical structure te zawk tan a remchan dan a tichiang a ni.
Surgical site-a harsatna awm thei, implant dang ang bawkin.
Screw loosening emaw plate breakage emaw instance rare instances te chu dah dik loh vang emaw, extreme stress vang emaw a ni.
Low-profile design awm mahse irritation tenau tak tak a awm thei.
General emaw local anesthesia emaw hian operation neih laiin a pianpui hlauhawmna a keng tel a ni.
Extended fixation chuan implant chhehvela ruh localized thinning a thlen thei.
Material science leh implant design lama thil thar chhuah hian a rah chhuah a tichak zel a ni.
Kawngpui accident leh infiamna lama hliam tuar tamna hian advanced implant mamawhna a thlen a ni.
Healthcare access lama hmasawnna, a bik takin emerging markets-a hmasawnna chuan hun remchang thar a siam a ni.
Aesthetic procedures hian implant dik leh rintlak mamawhna a tipung a ni.
Bioresorbable materials chungchanga zirchianna chuan maxillofacial implants landscape chu a sawifiah thar leh thei ang.
1.5 maxillofacial micro locking straight bridge plate hian maxillofacial fracture enkawlna kawngah hmasawnna nasa tak a entir a ni. Micro locking mechanism, biocompatible materials, leh low-profile design ang chi features te nen chuan stabilization dik tak leh patient outcome sang zawk a awm theih nan a pui a ni. Risk awm thei awm mah se, a hlawkna tam tak chuan tunlai maxillofacial surgery-ah chuan hmanraw hlu tak a ni. Technological innovation leh market trend a lo thang zel a, 1.5 maxillofacial micro locking straight bridge plate hmalam hun chuan damlo enkawlna leh surgical hlawhtlinna tihpunna tur thutiam ropui tak a keng tel a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | Milem | Item no. | Specification 100 a ni. |
1.5 Maxillofacial Micro locking chu a rawn thleng ta a ni. | ![]() |
RP1HS420J1000 a ni. | 4 holes, 0.6mm, 20mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties tes |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 1.5 maxillofacial micro locking straight bridge plate product catalog a awm theih nan zawt rawh.
2. I duh duh thlang rawh 1.5 maxillofacial micro locking straight bridge plate product.
3. 1.5 maxillofacial micro locking straight bridge plate test turin sample dil rawh.
4.A order chu XC Medico-a 1.5 maxillofacial micro locking straight bridge plate.
5.XC Medico-a 1.5 maxillofacial micro locking straight bridge plate-a dealer ni rawh.
1.A lei man tha zawk 1.5 Maxillofacial micro locking straight bridge plate.
2.100% A quality sang ber 1.5 Maxillofacial micro locking straight bridge plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tling tawk 1.5 maxillofacial micro locking straight bridge plate.
6. XC Medico-a 1.5 maxillofacial micro locking straight bridge plate-a thil tih dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Maxillofacial fractures hian functional recovery leh aesthetic restoration pahnih a neih theih nan tailored leh precise approach a mamawh a ni. 1.5 Maxillofacial Micro Locking Straight Bridge Plate hi implant hmasawn tak a ni a, hmai structure nalh tak takte tihngheh a nih theihna tura harsatna danglam bikte hmachhawn tura siam a ni. He guide hian a lan dan, a hlawkna, a hman dan, a hlauhawmna, leh a hmalam hun atana a theihnate chipchiar taka a zir chianna a pe a ni.
1.5 maxillofacial micro locking straight bridge plate hi specialized orthopedic implant engineered a ni a, maxillofacial region-a fracture tenau leh inthup tak takte tan stable fixation a pe thei a ni. A straight bridge design hian complex fracture pattern hrang hrangah versatile application a siam thei a, ruh dam laiin alignment dik tak leh rintlak taka support a awm theih phah a ni. Material hmasawn leh engineering technique hmanga siam a ni a, tunlai maxillofacial surgery-a thil phut a phuhruk a ni.
Screw te chu plate chhungah nghet takin a lock a, chu chuan stable fixation a awm theih nan leh a lo chhuahna tur a tihziaawm theih nan.
Fracture chi hrang hrang leh anatomical configuration hrang hrang tan adaptability a pe.
Titanium emaw titanium alloy atanga siam a nih avangin tissue inmilna tha tak leh corrosion laka inven theihna a siam tha hle.
Soft tissue irritation a ti tlem a, postoperative comfort a tichak bawk.
Intraoperative adjustment mamawhna a ti tlem a, surgical workflows a ti awlsam bawk.
Interference awm lovin postoperative imaging chiang tak a siam thei a, follow-up dik tak a siamsak thei bawk.
ruh tliakte chu a nghetin a nghet thei a, damna tha leh rintlak tak a siam thei bawk.
Pre-contoured design leh hman awlsamna features te hian surgical efficiency a ti tha hle.
Low-profile structure hian postoperative discomfort leh hardware lakchhuah a ngaihna a ti tlem hle.
Maxillofacial fracture hrang hrang tan a tha a, naupang leh comminuted case te pawh a tel.
Biomechanical stress tuar thei tura duan, hun rei tak chhunga dinhmun nghet leh rintlakna pe thei.
Symphysis, parasymphysis, leh angle fractures atan a tha hle.
Zygomatic leh maxillary fractures te tan stabilization a pe bawk.
Orbital floor leh rim hmanga hliam tuar te tan fixation dik tak a siamsak.
Le fort I, II, leh III fracture pattern complex tak tak enkawlna atan a tha.
Compact design hian naupangte anatomical structure te zawk tan a remchan dan a tichiang a ni.
Surgical site-a harsatna awm thei, implant dang ang bawkin.
Screw loosening emaw plate breakage emaw instance rare instances te chu dah dik loh vang emaw, extreme stress vang emaw a ni.
Low-profile design awm mahse irritation tenau tak tak a awm thei.
General emaw local anesthesia emaw hian operation neih laiin a pianpui hlauhawmna a keng tel a ni.
Extended fixation chuan implant chhehvela ruh localized thinning a thlen thei.
Material science leh implant design lama thil thar chhuah hian a rah chhuah a tichak zel a ni.
Kawngpui accident leh infiamna lama hliam tuar tamna hian advanced implant mamawhna a thlen a ni.
Healthcare access lama hmasawnna, a bik takin emerging markets-a hmasawnna chuan hun remchang thar a siam a ni.
Aesthetic procedures hian implant dik leh rintlak mamawhna a tipung a ni.
Bioresorbable materials chungchanga zirchianna chuan maxillofacial implants landscape chu a sawifiah thar leh thei ang.
1.5 maxillofacial micro locking straight bridge plate hian maxillofacial fracture enkawlna kawngah hmasawnna nasa tak a entir a ni. Micro locking mechanism, biocompatible materials, leh low-profile design ang chi features te nen chuan stabilization dik tak leh patient outcome sang zawk a awm theih nan a pui a ni. Risk awm thei awm mah se, a hlawkna tam tak chuan tunlai maxillofacial surgery-ah chuan hmanraw hlu tak a ni. Technological innovation leh market trend a lo thang zel a, 1.5 maxillofacial micro locking straight bridge plate hmalam hun chuan damlo enkawlna leh surgical hlawhtlinna tihpunna tur thutiam ropui tak a keng tel a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp