RP1Z6 a ni
XCmedico a ni
Maxillofacial a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Hming | Milem | Item No. | A sawifiahna |
| 1.5 Orthognathic Micro 110°L-Plate hmanga siam a ni | ![]() ![]() |
RP1Z622L1L a ni | 6 hole, 0.6mm, 22mm, Vei lamah a awm |
| RP1Z626L1L a ni | Hole 6, 0.6mm, 26mm, Vei lamah a awm | ||
| RP1Z630L1L a ni | Hole 6, 0.6mm, 30mm, Vei lamah a awm | ||
| RP1Z622L1R a ni | Hole 6, 0.6mm, 22mm, Dinglamah a awm | ||
| RP1Z626L1R a ni | 6 hole, 0.6mm, 26mm, Dinglamah a awm | ||
| RP1Z630L1R a ni | 6 hole, 0.6mm, 30mm, Dinglam ah a awm |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team hnenah 1.5 Orthognathic Micro 110°L-Plate Product Catalog dil rawh.
2. I duhzawng 1.5 Orthognathic Micro 110°L-Plate Product thlang rawh.
3. 1.5 Orthognathic Micro 110°L-Plate Test turin Sample Dil rawh.
4.XC Medico-in 1.5 Orthognathic Micro 110°L-Plate a siam chu Order siam rawh.
5.XC Medico-a 1.5 Orthognathic Micro 110°L-Plate Dealer ni rawh.
1.1.5 Orthognathic Micro 110°L-Plate lei man tha zawk.
2.100% Quality sang ber 1.5 Orthognathic Micro 110°L-Plate hmanga siam a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Orthognathic Micro 110°L-Plate 1.5 tling tur a ni.
6. XC Medico-in 1.5 Orthognathic Micro 110°L-Plate a siam chu rang tak leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
Orthognathic surgery, jaw deformities, fractures, emaw maxillofacial condition dang siamhatna atana mamawh fo chu ruh nghet taka tihngheh theihna tura ruahman implant hmannaah a innghat nasa hle. 1.5 Orthognathic Mini 110°L-Plate hi he domain-a hmanraw bik tak a ni a, surgeon-te tan reconstructive surgery neih laiin ruh structures stabilize leh realigning-na tur solution tha tak a pe a ni. He kaihhruaina kimchang takah hian 1.5 Orthognathic Mini 110°L-Plate design, a feature, a thatna, a clinical application, leh a hmanna avanga a hlauhawmna te kan zirchiang dawn a ni. He guide hian medical professional, researcher, leh orthopaedic leh maxillofacial surgery lama tui zirlai te tan hmanraw hlu tak a nih a tum a ni.
1.5 Orthognathic Mini 110°L-Plate hi specialized surgical implant a ni a, maxillofacial region-a fracture, fracture with displacement, leh deformities enkawlna atana hman thin a ni. He 'mini' plate, '1.5,' tia vuah hian mandible leh maxilla-a ruh structure nalh leh te zawkte tana a size leh dimension a inhmehzia a tarlang a ni. '110° L-Plate' tih hian plate angular design a kawk a, chu chu 110-degree angle-a strategically design a ni a, hei hian ruh a dam laiin a stability leh support a tichak zawk a ni.
Medical-grade titanium emaw stainless steel ang chi biocompatible material atanga siam niin, he implant hian chakna, a inthlak danglam theihna leh hman awlsamna a pe a ni. Plate-a 110-degree angle dik tak hian ruh chi hrang hrangte chu a ti nghet thei hle a, chutih rualin alignment dik tak a tichak a, dam leh laiin malunion emaw nonunion emaw ang chi complication awm theihna a ti tlem bawk.
Plate ke inkar 110° angle hian ruh fixation a tichak a, fractured segments te chu a dik zawka alignment a phalsak a, stress a ti tlem a, healing process a pui bawk.
Plate design miniaturized hian minimal invasiveness a tichiang a, hei hi ruh te zawk emaw, ruh nalh zawk emaw hmanga surgery neihna atan a pawimawh hle a, chu chu naupang emaw geriatric patient-te tan pawh a pawimawh hle.
Titanium alloy emaw stainless steel atanga siam niin, 1.5 Orthognathic Mini 110°L-Plate hian mechanical strength tha tak leh hun rei tak chhunga stability tha tak a pe a, hei hian a dam chhungin plate chu a chhiat loh nan a enkawl a ni.
Titanium hi biocompatibility sang zawk hian allergic reaction, infection, rejection hlauhawmna a ti tlem a, taksaa hman atan a tha hle.
Plate hi malleable a ni a, surgery neih laiin damlo ruh structure anatomical contours nena inmil em tih siamthat theih a ni. Hei hian surgical time a tihtlem bakah operation precision a ti sang bawk.
Plate-ah hian ruh-a nghet taka dah theihna tura siam, pre-drilled screw holes tam tak a awm a, hei hian a stability sang ber a tichiang a, hardware chhiat theihna a ti tlem bawk.
110-degree angle danglam tak hian support leh chakna tha zawk a pe a, ruh tliak te stability a ti tha a, a dam chhungin a hmunah a awm reng theih nan a pui bawk.
Alignment dik tak a neih theih nan plate hian a dam chak zawk a, malunion, nonunion, emaw ruh inthlak danglamna ang chi harsatna awm theihna a ti tlem bawk.
A compact size leh ergonomic design hian surgery tihnaah hian minimally invasive approach a siam a, chu chuan soft tissue tihbuai a ti tlem a, damlote tan pawh dam rei zawk a ni.
Plate design nghet tak hian stress hnuaia a hlawhchham theihna a ti tlem a, recovery phase-ah pawh implant hian ruh chi hrang hrangte chu a vawng tha thei tih a tichiang a ni.
1.5 Orthognathic Mini 110°L-Plate hi jaw leh face-a fracture leh deformity hrang hranga hman theih turin a insiamrem hle a, simple leh complex case-ah pawh hman theih a ni.
Plate hi mandible-a fracture fixation-ah hman a ni fo a, a bik takin lower jaw taksa, angle emaw symphysis emaw nena inzawm a ni. 110-degree angle hian alignment leh support dik tak a siam thei a, hei hian dam laia misalignment awm theihna a ti tlem a ni.
Upper jaw a tliak chuan 1.5 Orthognathic Mini 110°L-Plate hian maxillary bone tan stabilization mamawh a pe a, chu chuan fracture chu a anatomical position dik takah a dam theih nan a pui a ni.
Plate hi zygomatic bone (cheekbone)-a fracture fixation-ah pawh hman theih a ni a, hmai symmetry vawng reng tur leh post-reconstruction hnathawhna atana mamawh support a pe a ni.
Plate-a 110-degree angle dik tak hi displaced fracture enkawlna atan a hlawk hle a, ruh segment te chu alignment atanga chhuakin a inthlak a, stability a pe a, alignment dik takah a pui bawk.
Design te zawk, a inthlak danglam theih zawk avangin plate hi naupang emaw, kum upa lam emaw damlo ruh chakna a tlahniam thei a, ruh chakna a tlahniam thei a, ruh tliak tan chuan duhthlanna tha tak a ni.
Titanium hi biocompatibility nei mahse, surgery hmunah hian natna kai theihna a awm reng a ni. Hetiang hlauhawmna tihziaawm nan hian prophylactic antibiotics hman a ni fo thin.
Hun kal zelah plate chu a inthlak emaw, a inthlak emaw thei a, a bik takin ruh dam a tlai emaw, a tling tawk lo emaw a nih chuan, surgery hmanga enfiah a ngai a ni.
Thil engemaw takah chuan ruh chu a dam dik lo thei a, chu chuan nonunion (dam lohna) emaw malunion (damna dik lo) emaw a thlen thei a, chung pahnih chu operation dang neih belh a ngai thei a ni.
Facial nerve pawimawh tak takte hnaih lutuk hi ngaihtuah chuan plate dah chhunga nerve tihchhiat theihna a tlem a, chu chuan sensory deficit emaw motor dysfunction emaw a thlen thei a ni.
A tlem hle nachungin, damlo ṭhenkhat chuan plate-a thil hman, titanium emaw, stainless steel emaw ang chite chu allergy an nei thei a ni.
Mechanical stress nasa lutuk emaw, ruh dam tha lo emaw a nih chuan plate ngei pawh a chau emaw, a chhe thei emaw a, chu chuan fracture fixation stability pum pui a tichhe thei a ni.
Kawngpuiah accident, infiamna lama hliam, leh taksa lama tihduhdahna a pun zel avangin 1.5 Orthognathic Mini 110°L-Plate ang chi surgical implant rintlak mamawhna a sang chho zel a ni.
Surgery hman dan a lo thang zel a, heng technique tharte hi pui thei tur implant hmasawn tak tak mamawhna a sang chho zel a ni. 1.5 Orthognathic Mini 110°L-Plate hi a adaptability leh precision vangin surgical approach thar ber ber hman atan a tha hle.
Khawvel mihring pun chak chhoh zel avangin ruh natna, ruh tliak, leh pianpui piansualna te enkawlna atan ruh leh hmai surgery neih a ngai nasa hle a, hei hian market mamawhna a tipung a ni.
Ram thang mekte healthcare system a lo zau zel a, a lo tha chho zel a, surgical implant tha tak tak mamawhna a sang chho zel tura ngaih a ni a, a bik takin China, India leh Brazil ang ramteah chuan a pung chho zel dawn a ni.
1.5 Orthognathic Mini 110°L-Plate hi specialized surgical implant a ni a, maxillofacial region-a ruh tliak emaw, deformed emaw stabilization leh realignment-ah hlawkna nasa tak a pe a ni. A chakna sang tak, biocompatibility leh ergonomic design a neih avangin he plate hian orthognathic surgery nei damlote tan support tha zawk a pe a ni. Infection, nerve chhiatna, plate migration ang chi inherent risk a awm laiin, 1.5 Orthognathic Mini 110°L-Plate hlawkna hian recovery outcome tha ber siam tum surgeon te tan hmanraw pawimawh tak a ni. Maxillofacial surgery mamawhna sang zel leh surgical technique lama hmasawnna te hian he implant hi market hmasawn leh lo piang chhuak zingah pawh hman a nih theihna tur hmalam hun duhawm tak a tilang a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp