Hming | Milem | Item no. | Specification 100 a ni. |
1.5 Orthognathic Micro Anatomical L-Plate 1. A rilru a hah lutuk chuan a rilru a buai em em a. | ![]() ![]() |
RP1ZJ618L1L a ni. | 6 holes, 0.6mm, 18mm, veilam |
RP1ZJ620L1L a ni. | 6 holes, 0.6mm, 20mm, veilam | ||
RP1ZJ622L1L a ni. | 6 holes, 0.6mm, 22mm, veilam | ||
RP1ZJ618L1R a ni. | 6 holes, 0.6mm, 18mm, dinglam | ||
RP1ZJ620L1R a ni. | 6 holes, 0.6mm, 20mm, dinglam | ||
RP1ZJ622L1R a ni. | 6 holes, 0.6mm, 22mm, dinglam |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 1.5 Orthognathic Micro Anatomical L-Plate Product Catalog 1.5 zawt rawh.
2. I duh ber 1.5 Orthognathic Micro Anatomical L-Plate product thlang rawh.
3. 1.5 orthognathic micro anatomical L-plate test turin sample dil rawh.
4.XC Medico-a 1.5 orthognathic micro anatomical L-plate order siam.
5.XC Medico-a 1.5 orthognathic micro anatomical L-plate a hralhtu ni rawh.
1.A lei man a tha zawk 1.5 Orthognathic micro anatomical L-plate.
2.100% A quality sang ber 1.5 Orthognathic micro anatomical L-plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tling tawk 1.5 Orthognathic micro anatomical L-plate.
6. XC Medico-in 1.5 orthognathic micro anatomical L-plate a siam dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
1.5 orthognathic micro anatomical L-plate hi oral leh maxillofacial surgery-a hman thin specialized implant a ni a, orthognathic emaw jaw correction surgery neih laiin fixation dik tak a awm thei a ni. He miniaturized plate hi micro surgery atana siam bik a ni a, fracture fixation, osteotomies, leh aesthetic facial reconstruction-ah te hman a ni tlangpui. He guide kan chhui dawn hian a features, advantages, clinical applications, leh khawvel market-a a awmna a pun zel dan te kan delve ang.
1.5 orthognathic micro anatomical L-plate hi a te, titanium-based plate te tak te, maxillofacial surgery-a hman tur atana siam a ni. A thickness 1.5 mm chauh a nih avangin mandibular fractures, osteotomies, leh corrective jaw surgery te tan stabilization dik tak a pe a ni. Plate-a anatomical shape hian mandibular angle emaw critical region dang emaw-ah fixation tha ber a siam thei a, ruh tliak emaw siam thar emaw alignment leh stability dik tak a siam thei a ni.
Biocompatible titanium atanga siam niin, 1.5 orthognathic micro anatomical L-plate hi micro leh minimally invasive surgical procedure-a hman tur bik siam a ni. A lian lo lutuk hian damlo, procedure nalh tak tak mamawhtute tan hman theih a ni a, himna leh thlamuanna tichhe lovin functionality tihchangtlun a pe thei a ni.
Plate-a 1.5 mm thickness leh L-shaped design hian mandible natural anatomy nen chiang takin a inmil tih a tichiang a, a bik takin hmun nalh tak tak, mandibular angle leh condylar region-ah te a inmil hle. Anatomical shape hian operation neih chhunga siamthat ngai a ti tlem hle.
Titanium atanga siam niin, plate hian chakna danglam tak, a chhe thei lo, leh corrosion do theihna a pe a ni. Titanium’s biocompatibility hian taksain a hnawl tlem ber a ni a, hei hian hun rei tak chhunga damna atana duhthlanna rintlak tak a siam a ni.
Pre-drilled holes te hi micro screw te dah theihna turin dah a ni a, hei hian procedure chhung hian a dik leh him taka dah theih a ni. Hei hian misalignment hlauhawmna a ti tlem a, ruh tliak emaw, dah thar emaw tan pawh stabilization tha ber a pe bawk.
Plate lian lo tak leh design hian minimally invasive procedure a siam thei a, incisions te zawk a ngai a, a chhehvel tissue-ah trauma tlem zawk a thlen a, hei hian post-operative recovery time a ti tha zawk a ni.
Plate-a low profile hian soft tissue irritation a veng thei a, operation neih lai leh operation neih zawh hnuah pawh damlo hahdamna tha zawk a awm theih nan a pui bawk. Hei hi reconstructive emaw cosmetic jaw surgery nei damlote tan a pawimawh hle.
Orthognathic surgery-a hman ber a nih laiin, 1.5 orthognathic micro anatomical L-plate pawh hi mandibular fracture emaw post-traumatic reconstruction emaw range enkawlnaah a versatile hle bawk. A design hian surgical scenario hrang hrangah hman theih a ni.
Plate-a anatomical design dik tak chuan surgeon-te chu ruh tliak emaw, misaligned emaw-te optimal alignment an neih theih phah a ni. He precision hi aesthetic leh functional jaw correction surgery-ah a hlawkpui hle.
A lian lo hle a, a profile a hniam avangin 1.5 orthognathic micro anatomical L-plate hian minimally invasive procedures a ti awlsam a, incisions lian tak tak mamawhna a ti tlem a, a chhehvel soft tissue-ah pawh trauma a tlem phah hle. Hei hian post-operative pain a tlem zawk a, a dam thuai bawk.
Biocompatible titanium material hian natna kai theihna, inflammation, leh plate rejection te a tihziaawm theih nan a pui a ni. A corrosion-resistant nature hian a dam chhungin implant chu a awm reng theih nan a enkawl a ni.
Plate low profile hian soft tissue irritation a ti tlem a, damlo comfort a ti sang hle. Damlote chuan an rilru a hah lutuk leh an hlim loh phah thei a, post-operative experience tha zawk an nei thei a ni.
Minimally invasive techniques leh fracture fixation dik tak nen chuan recovery period hi a tawi zawk tlangpui. Damlote chuan hmanlai, invasive zawka enkawlna nena khaikhin chuan thil tih dan pangngai chu rang zawkin an thawk leh thei a ni.
1.5 Orthognathic Micro Anatomical L-Plate hian jaw hnathawh leh aesthetic hmel pahnih a siam tha leh thei a ni. Hei hi cosmetic reasons avanga surgery nei damlote tan emaw, jaw deformities avanga functional issues enkawl nan emaw a pawimawh hle.
Heng fracture te hi trauma emaw accident emaw avanga lo awm fo thin te hi mandibular angle ah an awm thin. Anatomical L-plate hian stabilization tha tak a pe a, ruh tliak chu alignment dik tak a siam thei a ni.
Mandible taksa kal tlanga fracture lo awm tan chuan plate hi dam chhungin ruh chu a hmunah nghet taka vawn theih a ni.
1.5 orthognathic micro anatomical L-plate hi surgery neih laiin an hmang tlangpui a, chu chuan jaw misalignment (eg, bilateral sagittal split osteotomy (BSSO) emaw Lefort osteotomies emaw) a siam ha hin. Plate hian ruhte chu a dah leh hnuah a stabilize a, chu chuan a hmui functional leh aesthetic aspects te chu a siam tha leh thei a ni.
Traumatic injuries hnuah chuan plate chu mandible siam thar leh stabilize nan hman a ni a, chu chuan fractured segments te chu a tidam tha hle a, nonunion ang chi complication te pawh a veng thei a ni.
Plate hi a bik takin displaced fractures tan a tangkai hle a, ruh fragments te chu realign turin stable fixation a pe a, malunion emaw nonunion emaw ang chi complication a awm loh nan.
Surgical procedure dang ang bawkin, implant awmna hmunah hian natna kai theihna a awm bawk. Surgery neih chhunga sterile technique dik tak enkawl hian he risk hi nasa takin a tihziaawm thei a ni.
Orthognathic surgery neih lai hian nerve, a bik takin mandible bula awmte, inferior alveolar nerve ang chi te chu a hliam thei a ni. Hei hian a hnuai lam hmui, hmui emaw, ha emaw-ah hian rilru hahna emaw, tingling emaw a thlen thei a ni.
Implant chu ruh damna tihkhawtlai a nih chuan emaw, damlo chu post-operative care a zawm loh chuan a lo chhuak thei a, a chhe thei bawk. Hei hian plate thlak emaw, siamrem emaw turin operation dang a mamawh thei bawk.
Plate low profile hian soft tissue irritation a tih tlem laiin, plate emaw screw emaw hian a chhehvel tissue a ti na thei a, a bik takin implant chu a inmil tawk lo a nih chuan a ti na thei hle.
Plate-in fixation tling a pek lohna hmunah chuan ruh segment-te chu a dam dik lo thei a, chu chuan malunion (misalignment) emaw nonunion (a dam theih lohna) emaw a thlen thei a ni.
Damlote chuan operation hnua an rilru a na thei a, an rilru a na thei bawk. Mahse, hei hi a tlangpuiin hun rei lote atan a ni a, hun leh enkawlna ha tak nen a reh hin.
Oral leh maxillofacial surgery-a cosmetic leh functional outcome pawimawhzia hriatna a pun zel avangin damlo tam zawk chuan restorative leh aesthetic benefits pahnih pe thei tur enkawlna an zawng mek a ni. Heng thil phut te phuhruk nan hian 1.5 orthognathic micro anatomical L-plate hi a awm tha hle a ni.
Minimally invasive surgery leh robotic surgery lama hmasawnna a awm avangin 1.5 orthognathic micro anatomical L-plate ang chi micro implant mamawhna a sang chho zel dawn a ni. Heng technology te hian precision placement leh recovery time rang zawk a siam thei a ni.
Khawvel puma healthcare access a ṭhat chhoh zel avangin, a bik takin emerging market-ah chuan damlo an tam chho zel dawn a, jaw correction leh fracture fixation surgery an mamawh dawn a ni. Hei hian 1.5 orthognathic micro anatomical L-plate ang chi implant quality tha tak tak mamawhna a tipung ngei ang.
Patient-centered care lam hawia inthlak danglamna a awm chuan, implant-te chu a lo thang chak hle a, chu chuan thlamuanna, hliam tlemte, leh dam leh thuai theihna a pe a ni. 1.5 orthognathic micro anatomical L-plate a low-profile design chu heng trends te nen hian a inmil a ni.
1.5 orthognathic micro anatomical L-plate hian maxillofacial surgery lama hmasawnna pawimawh tak a entir a, mandibular fracture leh jaw correction surgery te tan precision, stability, leh minimally invasive treatment options a pe a ni. Anatomical design, titanium construction, leh small profile te hmang hian damlote tan functional recovery leh aesthetic enhancement pahnih a awm thei a ni. Risk awm mahse, surgical technique dik tak leh post-operative care hian harsatna a tihziaawm thei a ni. Advanced surgical implants mamawhna a sang zel a, 1.5 orthognathic micro anatomical L-plate chu khawvel market-ah hman belh zel a nih theih nan a inpeih tawh a, surgeon leh damlote tan pawh hlawkna a thlen thei dawn a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | Milem | Item no. | Specification 100 a ni. |
1.5 Orthognathic Micro Anatomical L-Plate 1. A rilru a hah lutuk chuan a rilru a buai em em a. | ![]() ![]() |
RP1ZJ618L1L a ni. | 6 holes, 0.6mm, 18mm, veilam |
RP1ZJ620L1L a ni. | 6 holes, 0.6mm, 20mm, veilam | ||
RP1ZJ622L1L a ni. | 6 holes, 0.6mm, 22mm, veilam | ||
RP1ZJ618L1R a ni. | 6 holes, 0.6mm, 18mm, dinglam | ||
RP1ZJ620L1R a ni. | 6 holes, 0.6mm, 20mm, dinglam | ||
RP1ZJ622L1R a ni. | 6 holes, 0.6mm, 22mm, dinglam |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 1.5 Orthognathic Micro Anatomical L-Plate Product Catalog 1.5 zawt rawh.
2. I duh ber 1.5 Orthognathic Micro Anatomical L-Plate product thlang rawh.
3. 1.5 orthognathic micro anatomical L-plate test turin sample dil rawh.
4.XC Medico-a 1.5 orthognathic micro anatomical L-plate order siam.
5.XC Medico-a 1.5 orthognathic micro anatomical L-plate a hralhtu ni rawh.
1.A lei man a tha zawk 1.5 Orthognathic micro anatomical L-plate.
2.100% A quality sang ber 1.5 Orthognathic micro anatomical L-plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tling tawk 1.5 Orthognathic micro anatomical L-plate.
6. XC Medico-in 1.5 orthognathic micro anatomical L-plate a siam dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
1.5 orthognathic micro anatomical L-plate hi oral leh maxillofacial surgery-a hman thin specialized implant a ni a, orthognathic emaw jaw correction surgery neih laiin fixation dik tak a awm thei a ni. He miniaturized plate hi micro surgery atana siam bik a ni a, fracture fixation, osteotomies, leh aesthetic facial reconstruction-ah te hman a ni tlangpui. He guide kan chhui dawn hian a features, advantages, clinical applications, leh khawvel market-a a awmna a pun zel dan te kan delve ang.
1.5 orthognathic micro anatomical L-plate hi a te, titanium-based plate te tak te, maxillofacial surgery-a hman tur atana siam a ni. A thickness 1.5 mm chauh a nih avangin mandibular fractures, osteotomies, leh corrective jaw surgery te tan stabilization dik tak a pe a ni. Plate-a anatomical shape hian mandibular angle emaw critical region dang emaw-ah fixation tha ber a siam thei a, ruh tliak emaw siam thar emaw alignment leh stability dik tak a siam thei a ni.
Biocompatible titanium atanga siam niin, 1.5 orthognathic micro anatomical L-plate hi micro leh minimally invasive surgical procedure-a hman tur bik siam a ni. A lian lo lutuk hian damlo, procedure nalh tak tak mamawhtute tan hman theih a ni a, himna leh thlamuanna tichhe lovin functionality tihchangtlun a pe thei a ni.
Plate-a 1.5 mm thickness leh L-shaped design hian mandible natural anatomy nen chiang takin a inmil tih a tichiang a, a bik takin hmun nalh tak tak, mandibular angle leh condylar region-ah te a inmil hle. Anatomical shape hian operation neih chhunga siamthat ngai a ti tlem hle.
Titanium atanga siam niin, plate hian chakna danglam tak, a chhe thei lo, leh corrosion do theihna a pe a ni. Titanium’s biocompatibility hian taksain a hnawl tlem ber a ni a, hei hian hun rei tak chhunga damna atana duhthlanna rintlak tak a siam a ni.
Pre-drilled holes te hi micro screw te dah theihna turin dah a ni a, hei hian procedure chhung hian a dik leh him taka dah theih a ni. Hei hian misalignment hlauhawmna a ti tlem a, ruh tliak emaw, dah thar emaw tan pawh stabilization tha ber a pe bawk.
Plate lian lo tak leh design hian minimally invasive procedure a siam thei a, incisions te zawk a ngai a, a chhehvel tissue-ah trauma tlem zawk a thlen a, hei hian post-operative recovery time a ti tha zawk a ni.
Plate-a low profile hian soft tissue irritation a veng thei a, operation neih lai leh operation neih zawh hnuah pawh damlo hahdamna tha zawk a awm theih nan a pui bawk. Hei hi reconstructive emaw cosmetic jaw surgery nei damlote tan a pawimawh hle.
Orthognathic surgery-a hman ber a nih laiin, 1.5 orthognathic micro anatomical L-plate pawh hi mandibular fracture emaw post-traumatic reconstruction emaw range enkawlnaah a versatile hle bawk. A design hian surgical scenario hrang hrangah hman theih a ni.
Plate-a anatomical design dik tak chuan surgeon-te chu ruh tliak emaw, misaligned emaw-te optimal alignment an neih theih phah a ni. He precision hi aesthetic leh functional jaw correction surgery-ah a hlawkpui hle.
A lian lo hle a, a profile a hniam avangin 1.5 orthognathic micro anatomical L-plate hian minimally invasive procedures a ti awlsam a, incisions lian tak tak mamawhna a ti tlem a, a chhehvel soft tissue-ah pawh trauma a tlem phah hle. Hei hian post-operative pain a tlem zawk a, a dam thuai bawk.
Biocompatible titanium material hian natna kai theihna, inflammation, leh plate rejection te a tihziaawm theih nan a pui a ni. A corrosion-resistant nature hian a dam chhungin implant chu a awm reng theih nan a enkawl a ni.
Plate low profile hian soft tissue irritation a ti tlem a, damlo comfort a ti sang hle. Damlote chuan an rilru a hah lutuk leh an hlim loh phah thei a, post-operative experience tha zawk an nei thei a ni.
Minimally invasive techniques leh fracture fixation dik tak nen chuan recovery period hi a tawi zawk tlangpui. Damlote chuan hmanlai, invasive zawka enkawlna nena khaikhin chuan thil tih dan pangngai chu rang zawkin an thawk leh thei a ni.
1.5 Orthognathic Micro Anatomical L-Plate hian jaw hnathawh leh aesthetic hmel pahnih a siam tha leh thei a ni. Hei hi cosmetic reasons avanga surgery nei damlote tan emaw, jaw deformities avanga functional issues enkawl nan emaw a pawimawh hle.
Heng fracture te hi trauma emaw accident emaw avanga lo awm fo thin te hi mandibular angle ah an awm thin. Anatomical L-plate hian stabilization tha tak a pe a, ruh tliak chu alignment dik tak a siam thei a ni.
Mandible taksa kal tlanga fracture lo awm tan chuan plate hi dam chhungin ruh chu a hmunah nghet taka vawn theih a ni.
1.5 orthognathic micro anatomical L-plate hi surgery neih laiin an hmang tlangpui a, chu chuan jaw misalignment (eg, bilateral sagittal split osteotomy (BSSO) emaw Lefort osteotomies emaw) a siam ha hin. Plate hian ruhte chu a dah leh hnuah a stabilize a, chu chuan a hmui functional leh aesthetic aspects te chu a siam tha leh thei a ni.
Traumatic injuries hnuah chuan plate chu mandible siam thar leh stabilize nan hman a ni a, chu chuan fractured segments te chu a tidam tha hle a, nonunion ang chi complication te pawh a veng thei a ni.
Plate hi a bik takin displaced fractures tan a tangkai hle a, ruh fragments te chu realign turin stable fixation a pe a, malunion emaw nonunion emaw ang chi complication a awm loh nan.
Surgical procedure dang ang bawkin, implant awmna hmunah hian natna kai theihna a awm bawk. Surgery neih chhunga sterile technique dik tak enkawl hian he risk hi nasa takin a tihziaawm thei a ni.
Orthognathic surgery neih lai hian nerve, a bik takin mandible bula awmte, inferior alveolar nerve ang chi te chu a hliam thei a ni. Hei hian a hnuai lam hmui, hmui emaw, ha emaw-ah hian rilru hahna emaw, tingling emaw a thlen thei a ni.
Implant chu ruh damna tihkhawtlai a nih chuan emaw, damlo chu post-operative care a zawm loh chuan a lo chhuak thei a, a chhe thei bawk. Hei hian plate thlak emaw, siamrem emaw turin operation dang a mamawh thei bawk.
Plate low profile hian soft tissue irritation a tih tlem laiin, plate emaw screw emaw hian a chhehvel tissue a ti na thei a, a bik takin implant chu a inmil tawk lo a nih chuan a ti na thei hle.
Plate-in fixation tling a pek lohna hmunah chuan ruh segment-te chu a dam dik lo thei a, chu chuan malunion (misalignment) emaw nonunion (a dam theih lohna) emaw a thlen thei a ni.
Damlote chuan operation hnua an rilru a na thei a, an rilru a na thei bawk. Mahse, hei hi a tlangpuiin hun rei lote atan a ni a, hun leh enkawlna ha tak nen a reh hin.
Oral leh maxillofacial surgery-a cosmetic leh functional outcome pawimawhzia hriatna a pun zel avangin damlo tam zawk chuan restorative leh aesthetic benefits pahnih pe thei tur enkawlna an zawng mek a ni. Heng thil phut te phuhruk nan hian 1.5 orthognathic micro anatomical L-plate hi a awm tha hle a ni.
Minimally invasive surgery leh robotic surgery lama hmasawnna a awm avangin 1.5 orthognathic micro anatomical L-plate ang chi micro implant mamawhna a sang chho zel dawn a ni. Heng technology te hian precision placement leh recovery time rang zawk a siam thei a ni.
Khawvel puma healthcare access a ṭhat chhoh zel avangin, a bik takin emerging market-ah chuan damlo an tam chho zel dawn a, jaw correction leh fracture fixation surgery an mamawh dawn a ni. Hei hian 1.5 orthognathic micro anatomical L-plate ang chi implant quality tha tak tak mamawhna a tipung ngei ang.
Patient-centered care lam hawia inthlak danglamna a awm chuan, implant-te chu a lo thang chak hle a, chu chuan thlamuanna, hliam tlemte, leh dam leh thuai theihna a pe a ni. 1.5 orthognathic micro anatomical L-plate a low-profile design chu heng trends te nen hian a inmil a ni.
1.5 orthognathic micro anatomical L-plate hian maxillofacial surgery lama hmasawnna pawimawh tak a entir a, mandibular fracture leh jaw correction surgery te tan precision, stability, leh minimally invasive treatment options a pe a ni. Anatomical design, titanium construction, leh small profile te hmang hian damlote tan functional recovery leh aesthetic enhancement pahnih a awm thei a ni. Risk awm mahse, surgical technique dik tak leh post-operative care hian harsatna a tihziaawm thei a ni. Advanced surgical implants mamawhna a sang zel a, 1.5 orthognathic micro anatomical L-plate chu khawvel market-ah hman belh zel a nih theih nan a inpeih tawh a, surgeon leh damlote tan pawh hlawkna a thlen thei dawn a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp