rp2gglo a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Thilsiam | pic 10 a ni. | Inherh | Ref. | spec. |
Calcaneus-a plate-II-na a ni. | ![]() |
HB 4.0 a ni. | RP2GGLO3H a ni. | 3H a sei a ni. |
RP2GGLO4H a ni. | 4h a sei a ni. | |||
RP2GGSH3H a ni. | A tawi 3H . | |||
RP2GGSH4H a ni. | A tawi 4H . |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah Calcaneus Plate-II product catalogue hnenah zawt rawh.
2. I duh ber Calcaneus Plate-II product thlang rawh.
3. Calcaneus plate-II test tur sample dil rawh.
4.XC Medico-a Calcaneus plate-II order siam.
5.XC Medico-a Calcaneus Plate-II-a thil zuartu ni rawh.
1.Calcaneus Plate-II lei man tha zawk.
2.100% quality sang ber Calcaneus plate-II.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. Calcaneus plate-II tling tawk.
6. XC Medico-a Calcaneus Plate-II chungchang awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Calcaneus plate-II hi calcaneus emaw heel ruh emaw a fracture complex tak tak enkawlna atana siam, orthopedic implant specialized tak a ni. Displaced, comminuted, emaw intra-articular calcaneus fractures a awm chuan ruh alignment leh stability siam that nan surgical intervention a ngai fo thin. Calcaneus plate-II hian fixation tihchangtlun a pe a, hei vang hian complex fracture management-ah pawh rintlak tak a ni. He guide kimchang tak hian Calcaneus Plate-II design, features leh hlawkna te, a enkawlna atana a hman thin fracture chi hrang hrang te, a kaihhnawih hlauhawmna te, leh he orthopedic device hmalam hun thlirna te a zirchiang ang.
Calcaneus plate-II hi ke ruh lian ber, calcaneus ruh tliakte tihngheh nan orthopedic surgery-a hman thin Calcaneus plate hmanlai atanga hman thin a ni. Calcaneus fractures-in a pek chhuah anatomical challenges te tan bik a siam a ni a, chu chu a buaithlak fo va, damna dik tak neih theihna tur stable implant a mamawh a ni. Calcaneus Plate-II hian model hlui nena khaikhin chuan design, material, leh mechanical property-ah hmasawnna a pe a, fixation tha zawk, harsatna awm theihna a tlem a, damlo outcome pawh a tichangtlung zawk a ni.
Plate hi calcaneus lateral emaw posterior lam emaw-ah an hnawih tlangpui a, chu chu ruh tliak awm dan leh a awmna hmun azirin a ni. Titanium emaw stainless steel emaw hi an chakna, an property rit lo, leh biocompatibility vangin plate siamna atana hman tlanglawn ber an ni. Locking screw technology hman hian fixation strength pumpui a ti tha bawk a, hei hian calcaneus ang chi weight-bearing bones atan a tha hle.
Plate hi Calcaneus ruh complex geometry nena inmil turin engineer a ni a, snug fit a nih theih nan leh a dam chhunga malalignment awm theihna tur a tlem thei ang bera siam a ni.
Plate hian locking leh non-locking screw pahnih a support a, fixation method-ah pawh flexibility a pe thei a ni. Locking screw hian attachment him zawk a siam a, screw loosening leh stability tihchangtlun a veng a, non-locking screw hian fracture pattern hrang hrang atan versatility a pe thung.
Multiple screw holes hmang hian screw dahna tur chi hrang hrang a awm thei a, chu chuan fixation tha ber a siam thei a, ruh fragment te pawh a pui thei bawk.
A tlangpuiin titanium emaw stainless steel emaw atanga siam a ni a, plate hi a chhe thei lo leh a chakna tur atana siam a ni. Heng thilte hi corrosion laka inven theih an ni a, biocompatibility tha tak an nei a, chu chuan taksain implant a hnawl loh nan a enkawl a ni.
Tunlai calcaneus plate-II design tam tak hi radiolucent an ni a, chu chu X-ray emaw, imaging technique dang emaw a tibuai lo tihna a ni. Hei hian post-operative evaluation chiang tak leh ruh damna enfiah theihna a siam a ni.
Plate version thenkhatah chuan ruh fragment inkar a gap tihtlem nan integrated compression system a awm a, chu chuan ruh damna tha zawk a siam a, nonunion hlauhawmna a ti tlem bawk.
Plate anatomical design hian calcaneus chhe tawh chu alignment dik tak leh stable fixation a siam thei a, chu chuan outcome tha zawk leh malunion emaw nonunion emaw ang chi complication risk a hniam zawk a ni.
Locking leh non-locking screw te versatility te, customizable screw placement te hian plate chu calcaneus fracture chi hrang hranga siam theih a nih theih nan a enkawl a, chu chuan hlawhtling taka damna rate sang zawk a thlen thei a ni.
Calcaneus Plate-II-in a pek superior fixation hian ruh dam chak zawk a tichak a, damlote chu taksa rihna tihtlem hna thawh tan thuai a ni. Muscle atrophy leh joint stiffness ang chi complication hlauhawmna tihziaawmna turin early mobilization hi a pawimawh hle.
Plate-a low-profile nature hian soft tissue irritation hlauhawmna a ti tlem a, hliam harsatna awm theihna a ti tlem bawk. Hei hian post-operative recovery process awlsam zawk a siam thei a ni.
Locking screw hian fixation nghet zawk leh rintlak zawk a siam a, chu chuan screw loosening emaw implant failure emaw a awm theihna a ti tlem a, calcaneus ang chi high-stress area-ah pawh.
Heng ruh tliakte hian ruh chu chi hrang hranga then darh a huam a ni. Calcaneus plate-II hian heng fragments te hi a ti nghet thei hle a, alignment leh damna dik tak neih theihna tura a tul anga puihna a pe thei bawk.
Bone fragments te chu an inthlak danglam chuan calcaneus plate-II hian ruh fragment te chu a siam tha leh thei a, fracture na hmun chu a ti nghet a, a dam chhunga a inthlak danglam loh nan a pui bawk.
Heng fracture te hi joint space chhungah a inzar pharh a, calcaneus articular surface a nghawng a ni. Joint alignment dik tak siamhat hi arthritis leh joint dysfunction venna atan a pawimawh hle. Calcaneus plate-II hi a bik takin heng complex fractures te hi a awm theih nan an siam a ni.
Calcanei pahnih an tihchhiatna hmunah chuan calcaneus plate-II hmangin a sir lehlamah pawh a stabilize thei a, hei hian balanced healing a siam thei a, hun rei tak chhunga harsatna awm thei tur a ti tlem thei bawk.
Ruh quality chak lo, ruh natna nei te tan chuan osteoporosis nei te tan chuan Calcaneus plate-II hian stability leh fixation a ti sang a, ruh chakna tlahniam chu a rul a, fracture healing outcome a ti tha bawk.
Taksa chhunga thil dang dah luh a nih chuan surgery eng pawh ang bawkin, natna kai theihna a awm bawk. Operation post-operative care, hliam enkawlna dik tak leh antibiotic prophylaxis te pawh a tel a, hei hi natna kai theihna tihziaawmna atan a pawimawh hle.
Calcaneus hi critical nerve leh thisen kalna kawng hnai tak a ni. Surgery neih lai hian heng structure te hi tihchhiat theihna a awm a, chu chuan harsatna a thlen thei a, chu chu sensation hloh, motor dysfunction, emaw kea circulation tha lo te a ni.
Fixation dik tak awm mahse, ruhte chu a dam tha thei lo (nonunion) emaw, a awmna dik lo (malunion) emaw a dam thei lo thei a ni. Chutiang hunah chuan surgery dang neih belh a ngai thei bawk.
A tlem hle nachungin, plate emaw, screw emaw chu hun kal zelah a chhe thei a, a tizau thei bawk. Hei hian hardware thlak nan revision surgery a mamawh thei a ni.
Damlo thenkhat chuan operation hnuah natna emaw, hrehawmna emaw an nei thei a, a bik takin plate chu a langsar emaw, soft tissue vel a irritate emaw a nih chuan.
Post-operative immobility hian kea thisen zam a siam thei a, chu chuan deep vein thrombosis emaw pulmonary embolism emaw a thlen thei a ni. Hetiang hlauhawmna hi tihtlem nan hian mobilization leh anticoagulant therapy hmasa ber a pawimawh hle.
Khawvel mihring an lo upa chhoh zel chuan, a bik takin ruh tliakte hi ruh tliak an tam chho zel a, chu chu ruhro (osteoporotic) a ni. Hei hian Calcaneus Plate-II ang chi advanced fracture fixation devices mamawhna a tipung zel dawn a ni.
Biomaterial leh implant design chungchanga zirchianna chhunzawm zel hian orthopedic devices lama thil thar a siam chhuak a ni. Calcaneus plate-II hian heng hmasawnnate hi a hlawkpui hle a rinawm a, biocompatibility, durability, leh hman awlsamna kawngah hmasawnna a awm thei a ni.
Minimally invasive surgical technique lam hawia trend a pung zel a, heng approach te hi thlawp turin Calcaneus plate-II hi siam mek a ni. Incisions te zawk leh recovery time chak zawk te hi heng implant mamawhna tichaktu thil pawimawh tak a ni.
Hmasawnna hmuna healthcare infrastructure a lo ṭhat chhoh zel chuan damdawi lam enkawlna hmasawn tak takte chu a pung chho zel a ni. Hei hian heng market-ah te hian orthopedic implant, Calcaneus plate-II te pawh a huam tel a rinawm.
Calcaneus plate-II hi Calcaneus ruh tliak enkawlna atana hmanraw pawimawh tak a ni a, dinhmun nghet zawk siam a, damna rah chhuah tihchangtlun leh harsatna awm thei tihtlem a ni. Anatomical design, locking screw technology, leh fixation theihna sang zawk a neih avangin plate hian fracture alignment dik tak leh recovery chak zawk a tichiang a ni. Surgery nena inzawm hlauhawmna a awm laiin, Calcaneus Plate-II hi Calcaneus ruh tliak chi hrang hrang tan chuan a hlawk leh rintlak tak a la ni reng a ni. Hmalam hun thlirin, Calcaneus Plate-II market hmalam hun chu beisei awm tak niin a lang a, chu chu technology lama hmasawnna te, orthopedic implant mamawhna sang zel te, leh khawvel puma healthcare access pung zel te hian a tichak hle a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Thilsiam | pic 10 a ni. | Inherh | Ref. | spec. |
Calcaneus-a plate-II-na a ni. | ![]() |
HB 4.0 a ni. | RP2GGLO3H a ni. | 3H a sei a ni. |
RP2GGLO4H a ni. | 4h a sei a ni. | |||
RP2GGSH3H a ni. | A tawi 3H . | |||
RP2GGSH4H a ni. | A tawi 4H . |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah Calcaneus Plate-II product catalogue hnenah zawt rawh.
2. I duh ber Calcaneus Plate-II product thlang rawh.
3. Calcaneus plate-II test tur sample dil rawh.
4.XC Medico-a Calcaneus plate-II order siam.
5.XC Medico-a Calcaneus Plate-II-a thil zuartu ni rawh.
1.Calcaneus Plate-II lei man tha zawk.
2.100% quality sang ber Calcaneus plate-II.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. Calcaneus plate-II tling tawk.
6. XC Medico-a Calcaneus Plate-II chungchang awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
Calcaneus plate-II hi calcaneus emaw heel ruh emaw a fracture complex tak tak enkawlna atana siam, orthopedic implant specialized tak a ni. Displaced, comminuted, emaw intra-articular calcaneus fractures a awm chuan ruh alignment leh stability siam that nan surgical intervention a ngai fo thin. Calcaneus plate-II hian fixation tihchangtlun a pe a, hei vang hian complex fracture management-ah pawh rintlak tak a ni. He guide kimchang tak hian Calcaneus Plate-II design, features leh hlawkna te, a enkawlna atana a hman thin fracture chi hrang hrang te, a kaihhnawih hlauhawmna te, leh he orthopedic device hmalam hun thlirna te a zirchiang ang.
Calcaneus plate-II hi ke ruh lian ber, calcaneus ruh tliakte tihngheh nan orthopedic surgery-a hman thin Calcaneus plate hmanlai atanga hman thin a ni. Calcaneus fractures-in a pek chhuah anatomical challenges te tan bik a siam a ni a, chu chu a buaithlak fo va, damna dik tak neih theihna tur stable implant a mamawh a ni. Calcaneus Plate-II hian model hlui nena khaikhin chuan design, material, leh mechanical property-ah hmasawnna a pe a, fixation tha zawk, harsatna awm theihna a tlem a, damlo outcome pawh a tichangtlung zawk a ni.
Plate hi calcaneus lateral emaw posterior lam emaw-ah an hnawih tlangpui a, chu chu ruh tliak awm dan leh a awmna hmun azirin a ni. Titanium emaw stainless steel emaw hi an chakna, an property rit lo, leh biocompatibility vangin plate siamna atana hman tlanglawn ber an ni. Locking screw technology hman hian fixation strength pumpui a ti tha bawk a, hei hian calcaneus ang chi weight-bearing bones atan a tha hle.
Plate hi Calcaneus ruh complex geometry nena inmil turin engineer a ni a, snug fit a nih theih nan leh a dam chhunga malalignment awm theihna tur a tlem thei ang bera siam a ni.
Plate hian locking leh non-locking screw pahnih a support a, fixation method-ah pawh flexibility a pe thei a ni. Locking screw hian attachment him zawk a siam a, screw loosening leh stability tihchangtlun a veng a, non-locking screw hian fracture pattern hrang hrang atan versatility a pe thung.
Multiple screw holes hmang hian screw dahna tur chi hrang hrang a awm thei a, chu chuan fixation tha ber a siam thei a, ruh fragment te pawh a pui thei bawk.
A tlangpuiin titanium emaw stainless steel emaw atanga siam a ni a, plate hi a chhe thei lo leh a chakna tur atana siam a ni. Heng thilte hi corrosion laka inven theih an ni a, biocompatibility tha tak an nei a, chu chuan taksain implant a hnawl loh nan a enkawl a ni.
Tunlai calcaneus plate-II design tam tak hi radiolucent an ni a, chu chu X-ray emaw, imaging technique dang emaw a tibuai lo tihna a ni. Hei hian post-operative evaluation chiang tak leh ruh damna enfiah theihna a siam a ni.
Plate version thenkhatah chuan ruh fragment inkar a gap tihtlem nan integrated compression system a awm a, chu chuan ruh damna tha zawk a siam a, nonunion hlauhawmna a ti tlem bawk.
Plate anatomical design hian calcaneus chhe tawh chu alignment dik tak leh stable fixation a siam thei a, chu chuan outcome tha zawk leh malunion emaw nonunion emaw ang chi complication risk a hniam zawk a ni.
Locking leh non-locking screw te versatility te, customizable screw placement te hian plate chu calcaneus fracture chi hrang hranga siam theih a nih theih nan a enkawl a, chu chuan hlawhtling taka damna rate sang zawk a thlen thei a ni.
Calcaneus Plate-II-in a pek superior fixation hian ruh dam chak zawk a tichak a, damlote chu taksa rihna tihtlem hna thawh tan thuai a ni. Muscle atrophy leh joint stiffness ang chi complication hlauhawmna tihziaawmna turin early mobilization hi a pawimawh hle.
Plate-a low-profile nature hian soft tissue irritation hlauhawmna a ti tlem a, hliam harsatna awm theihna a ti tlem bawk. Hei hian post-operative recovery process awlsam zawk a siam thei a ni.
Locking screw hian fixation nghet zawk leh rintlak zawk a siam a, chu chuan screw loosening emaw implant failure emaw a awm theihna a ti tlem a, calcaneus ang chi high-stress area-ah pawh.
Heng ruh tliakte hian ruh chu chi hrang hranga then darh a huam a ni. Calcaneus plate-II hian heng fragments te hi a ti nghet thei hle a, alignment leh damna dik tak neih theihna tura a tul anga puihna a pe thei bawk.
Bone fragments te chu an inthlak danglam chuan calcaneus plate-II hian ruh fragment te chu a siam tha leh thei a, fracture na hmun chu a ti nghet a, a dam chhunga a inthlak danglam loh nan a pui bawk.
Heng fracture te hi joint space chhungah a inzar pharh a, calcaneus articular surface a nghawng a ni. Joint alignment dik tak siamhat hi arthritis leh joint dysfunction venna atan a pawimawh hle. Calcaneus plate-II hi a bik takin heng complex fractures te hi a awm theih nan an siam a ni.
Calcanei pahnih an tihchhiatna hmunah chuan calcaneus plate-II hmangin a sir lehlamah pawh a stabilize thei a, hei hian balanced healing a siam thei a, hun rei tak chhunga harsatna awm thei tur a ti tlem thei bawk.
Ruh quality chak lo, ruh natna nei te tan chuan osteoporosis nei te tan chuan Calcaneus plate-II hian stability leh fixation a ti sang a, ruh chakna tlahniam chu a rul a, fracture healing outcome a ti tha bawk.
Taksa chhunga thil dang dah luh a nih chuan surgery eng pawh ang bawkin, natna kai theihna a awm bawk. Operation post-operative care, hliam enkawlna dik tak leh antibiotic prophylaxis te pawh a tel a, hei hi natna kai theihna tihziaawmna atan a pawimawh hle.
Calcaneus hi critical nerve leh thisen kalna kawng hnai tak a ni. Surgery neih lai hian heng structure te hi tihchhiat theihna a awm a, chu chuan harsatna a thlen thei a, chu chu sensation hloh, motor dysfunction, emaw kea circulation tha lo te a ni.
Fixation dik tak awm mahse, ruhte chu a dam tha thei lo (nonunion) emaw, a awmna dik lo (malunion) emaw a dam thei lo thei a ni. Chutiang hunah chuan surgery dang neih belh a ngai thei bawk.
A tlem hle nachungin, plate emaw, screw emaw chu hun kal zelah a chhe thei a, a tizau thei bawk. Hei hian hardware thlak nan revision surgery a mamawh thei a ni.
Damlo thenkhat chuan operation hnuah natna emaw, hrehawmna emaw an nei thei a, a bik takin plate chu a langsar emaw, soft tissue vel a irritate emaw a nih chuan.
Post-operative immobility hian kea thisen zam a siam thei a, chu chuan deep vein thrombosis emaw pulmonary embolism emaw a thlen thei a ni. Hetiang hlauhawmna hi tihtlem nan hian mobilization leh anticoagulant therapy hmasa ber a pawimawh hle.
Khawvel mihring an lo upa chhoh zel chuan, a bik takin ruh tliakte hi ruh tliak an tam chho zel a, chu chu ruhro (osteoporotic) a ni. Hei hian Calcaneus Plate-II ang chi advanced fracture fixation devices mamawhna a tipung zel dawn a ni.
Biomaterial leh implant design chungchanga zirchianna chhunzawm zel hian orthopedic devices lama thil thar a siam chhuak a ni. Calcaneus plate-II hian heng hmasawnnate hi a hlawkpui hle a rinawm a, biocompatibility, durability, leh hman awlsamna kawngah hmasawnna a awm thei a ni.
Minimally invasive surgical technique lam hawia trend a pung zel a, heng approach te hi thlawp turin Calcaneus plate-II hi siam mek a ni. Incisions te zawk leh recovery time chak zawk te hi heng implant mamawhna tichaktu thil pawimawh tak a ni.
Hmasawnna hmuna healthcare infrastructure a lo ṭhat chhoh zel chuan damdawi lam enkawlna hmasawn tak takte chu a pung chho zel a ni. Hei hian heng market-ah te hian orthopedic implant, Calcaneus plate-II te pawh a huam tel a rinawm.
Calcaneus plate-II hi Calcaneus ruh tliak enkawlna atana hmanraw pawimawh tak a ni a, dinhmun nghet zawk siam a, damna rah chhuah tihchangtlun leh harsatna awm thei tihtlem a ni. Anatomical design, locking screw technology, leh fixation theihna sang zawk a neih avangin plate hian fracture alignment dik tak leh recovery chak zawk a tichiang a ni. Surgery nena inzawm hlauhawmna a awm laiin, Calcaneus Plate-II hi Calcaneus ruh tliak chi hrang hrang tan chuan a hlawk leh rintlak tak a la ni reng a ni. Hmalam hun thlirin, Calcaneus Plate-II market hmalam hun chu beisei awm tak niin a lang a, chu chu technology lama hmasawnna te, orthopedic implant mamawhna sang zel te, leh khawvel puma healthcare access pung zel te hian a tichak hle a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp