RP135DHS a ni
XCmedico a ni
Femur a ni
1 Pcs(Darkar 72 chhunga thawn chhuah)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Thilsiam | Pic | Inherh | REF. | Spec. |
| 135° DHS Plate a ni | ![]() |
HA 4.5 Lag Screw hmanga siam a ni |
RP135DHS3H a ni | 3H a ni |
| RP135DHS4H a ni | 4H a ni | |||
| RP135DHS5H a ni | 5H a ni | |||
| RP135DHS6H a ni | 6H a ni | |||
| RP135DHS7H a ni | 7H a ni | |||
| RP135DHS8H a ni | 8H a ni | |||
| RP135DHS9H a ni | 9H a ni | |||
| RP135DHS10H a ni | 10H a ni | |||
| RP135DHS11H a ni | 11H a ni | |||
| RP135DHS12H a ni | 12H a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team hnenah 135° DHS Plate Product Catalog zawt rawh.
2. I duhzawng 135° DHS Plate Product thlang rawh.
3. 135° DHS Plate Test turin Sample Dil rawh.
4.XC Medico-a 135° DHS Plate Order siam rawh.
5.XC Medico 135° DHS Plate Dealer ni rawh.
1.135° DHS Plate lei man tha zawk.
2.100% Quality sang ber 135° DHS Plate a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. 135° DHS Plate tling tur.
6. XC Medico-in 135° DHS Plate a siam dan awlsam leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
135° DHS Plate hi orthopedic implant pawimawh tak a ni a, a bik takin femoral neck fracture, intertrochanteric fracture leh a kaihhnawih hliam dangte enkawlna atan hman a ni. Dynamic hip screw (DHS) system-a tel a ni a, hei hi hip fracture-te stable internal fixation neih theihna atana hmanraw din tawh a ni a, a bik takin damlo tar emaw, ruh natna nei emaw tan a ni. He kaihhruaina kimchang tak hian 135° DHS Plate-a thil pawimawh tak tak, a thatna, a hman dan, a hlauhawmna leh a hmalam hun atana market potential te a zirchiang dawn a, medical professional-te chu tunlai orthopaedic practice-a a chanvo hriatthiamna a pe ang.
135° DHS Plate hi specialized orthopedic device a ni a, dynamic hip screw (DHS) nen tangkawpin femoral fractures stabilize nan hman a ni. '135°' tih hian dynamic screw leh plate inkar angle a kawk a, hei hi femur natural alignment ang deuha siam a ni a, healing process chhunga stability tha ber pe thei tura siam a ni.
He angle hian screw chu dynamically-in a thawk thei a, chu chuan fracture site chhungah tlem a kal thei a ni. He movement hian callus siamna kawngah a pui a, damna a tichak bawk. 135° DHS Plate hi hip fracture nei damlote tan hman a ni tlangpui.Plate hi stainless steel emaw titanium emaw ang chi thil chakna sang tak atanga siam a ni a, chung pahnih hian mechanical property tha zawk leh biocompatibility an pe a, hei hian a chhe thei lo a, hnawl theihna a nei tlem hle.
Plate hi femur natural curvature nena inmil turin contoured a ni a, hei hian fracture stabilization tha ber atan fit snug leh secure tak a pe a ni.
Plate hian dynamic locking screw system a hmang a, chu chuan screw chu plate chhungah tlem a slide thei a ni. He controlled movement hian ruh damna a ti awlsam a, ruh ruh tliakna hmunah micro-movement a phalsak a, callus siamna a tichak a ni.
Dynamic screw leh plate inkar 135-degree angle hian femur biomechanical property a entawn a, weight transfer tha zawk a tichak a, complication awm theihna a ti tlem bawk.
Plate-ah hian screw hole engemaw zat a awm a, chu chuan screw dahnaah flexibility a siam a, damlo taksa peng hrang hrang leh fracture type a zirin individualized fracture management a siam thei a ni.
135° DHS Plate hi high-grade stainless steel emaw titanium alloy hmanga siam a ni a, hei hi a chakna, a chhe thei lo leh a rit lo avangin hriat hlawh tak a ni a, damlo tan a chhe thei lo a, a hahdam thei bawk.
Low-profile design hian soft tissue irritation a ti tlem a, hei hi bulkier implants-ah chuan ngaihtuahawm tak a ni thei a, post-operative pain tihziaawmna leh rang zawka damna a thlen thei a ni.
Dynamic screw-locking mechanism hian screw leh plate inkarah motion tlemte a phalsak avangin fracture stability tha tak a siam a, hei hian callus siamna leh ruh tihdamna kawngah a pui a ni.
135-degree angle hian hip joint-a mechanical load sem darh a pui a, hei hian implant-a stress a tihziaawm bakah implant a hlawhchham theihna a ti tlem a, a bik takin osteoporotic bone nei damlote tan a ni.
Plate angle leh design hian hip-a natural biomechanics a entawn a, chu chuan damlo taksa rihna chu a kal laiin a transfer tha zawk a, operation hnua harsatna awm theihna a ti tlem a ni.
Plate design hniam tak leh anatomical fit hian soft tissue irritation a ti tlem a, hei hian post-surgical comfort leh recovery a pui hle.
135° DHS Plate hi hmanraw tangkai tak a ni a, hip fracture hrang hrangah hman theih a ni a, ruh natna vei, kum upa lam, leh revision surgery ngai thei te tan pawh hman theih a ni.
135° DHS Plate pawh telna DHS system hi kum sawm tam tak chhung chu clinical practice-ah hman a ni tawh a, hip fracture enkawlna kawngah a tangkai hle tih finfiah a ni a, a bik takin geriatric population-ah a tangkai hle.
135° DHS Plate hi femur lu hnuai lam chiaha ruh tliak, tlu emaw direct trauma emaw avanga lo awm fo thin tan hman a ni. Heng fracture te hi enkawl a harsa hle a, a chhan chu alignment dik tak leh femoral head-a thisen supply neih a pawimawh vang a ni.
Greater leh lesser trochanters (femur ruh langsar tak takte) inkara fracture hi damlo tarte zingah a awm fo a, energy hniam taka tlak vang a ni fo bawk. 135° DHS Plate hian heng fracture te hi stable fixation a pe a, hei hian weight-bearing hma leh rang zawka dam leh theihna a siamsak a ni.
Heng fracture te hi trochanteric region bulah a awm a, a tlangpuiin a nihna takah chuan complex tak a ni. Chutiang hunah chuan 135° DHS Plate hi a hlawkpui hle a, fixation system nghet tak a pe a, a ruh tliak pawh a dam tha thei bawk.
Kum upa lam ruh density chak loteah chuan femoral neck emaw intertrochanteric region-ah fracture a awm thei a, trauma tlemte chauh a awm thei. 135° DHS Plate-a locking mechanism hian heng ruh chhe thei lote tan hian stabilization tha zawk a pe a, non-union emaw implant failure emaw a awm theihna a ti tlem a ni.
Orthopaedic surgery dang ang bawkin, incision site emaw, implant chhehvelah emaw natna kai theihna a awm a, a bik takin surgery neih laiin sterile technique dik tak zawm a nih loh chuan.
Plate hian stabilization tha tak pe mahse, a ruh chu a dam tha lo thei a, chu chuan non-union emaw malunion (a dam laiin fracture chu a dik lo) a thlen thei a ni.
Thil engemaw takah chuan, a bik takin ruh quality tha lo (eg, osteoporotic bone) nei damlote tan chuan screw emaw plate emaw hian fixation tha tak a pe thei lo a, chu chuan implant loosening emaw fracture displacement emaw a thlen thei a ni.
Surgery an tih lai hian, a bik takin hip joint bula complex fracture-ah chuan, tum loh taka thisen kalna kawng emaw, nerve emaw tihchhiat theihna a awm a ni.
Operation hnua rei tak che thei lo chuan deep vein thrombosis (DVT) vei theihna a tipung thei a, a bik takin damlo kum upa zawk emaw, hriselna lama harsatna dang nei emaw tan chuan a tipung thei a ni.
Khawvel mihring upa chho zel, a bik takin ram changkang zawkah chuan damlo kum upa zawkte zingah ruh natna (osteoporotic fracture) leh ke ruh tliak (femoral fracture) a awm chho zel a, hei hian 135° DHS Plate ang chi orthopaedic implant mamawhna a tipung hle.
Implant materials lama hmasawnna chhunzawm zel, alloy chak zawk, rit zawk siam chhuah te hian 135° DHS Plate hnathawh a tichak ang a, clinical practice-a hmanna a tizau lehzual ang.
Surgeon-te chuan minimally invasive surgical technique an hmang nasa hle a, hei hian dam leh hun leh surgical complication a ti tlem thei a ni. 135° DHS Plate hi heng technique te nen hian a inmil a, nakin lawka orthopaedic practice-ah pawh a inzawmna a tichiang hle.
Emerging market-a healthcare infrastructure a ṭhat chhoh zel avangin orthopaedic implant quality sang tak mamawhna a sang chho dawn a, hei hian heng biala 135° DHS Plate market potential a tizau dawn a ni.
135° DHS Plate hi femoral neck fracture, intertrochanteric fracture leh hip injury dang enkawlna atana hman thin dynamic hip screw system-a thil pawimawh tak a ni. A danglam bikna 135-degree angle, anatomical design, leh dynamic locking mechanism te hian stability tha zawk a pe a, damna a tichak a, damlo leh orthopaedic surgeon te tan pawh duhthlanna rintlak tak a ni. Surgery nena inzawm hlauhawmna engemaw zat a awm laiin, 135° DHS Plate hian a thatna chu a chhiatna awm thei aiin a tam zawk daih a, a bik takin kum upa lam emaw, ruh natna nei emaw tan chuan a tha lo hle. Track record finfiah tawh, versatility, leh market demand sang zel avang hian 135° DHS Plate hian kum tam tak chhung chu orthopedic fracture management-ah hmun pawimawh tak a chang chhunzawm zel dawn a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp