RJSG
Xcmedico
1 pcs (72 siegħa kunsinna)
Humerus
Liga tat-titanju jew azzar li ma jissaddadx
CE / ISO: 9001 / ISO13485.ETC
Kunsinna magħmula minn 15-il ġurnata apposta (eskluż il-ħin tat-tbaħħir)
FedEx. Dhl.tnt.ems.etc
Disponibbiltà: | |
---|---|
Kwantità: | |
Prodotti | Stampa | Mudelli speċifiċi | Speċifikazzjoni |
HUMERUS MULTI Lock intramedullary Dwiefer | ![]() | RJSG18160R | 8.0 × 160r |
RJSG18160L | 8.0 × 160L | ||
RJSG19160R | 9.0 × 160R | ||
RJSG19160L | 9.0 × 160L | ||
RJSG17180R | 7.0 × 180 | ||
RJSG17195R | 7.0 × 195 | ||
RJSG17210R | 7.0 × 210 | ||
RJSG17225R | 7.0 × 225 | ||
RJSG17240R | 7.0 × 240 | ||
RJSG17255R | 7.0 × 255 | ||
RJSG18180R | 8.0 × 180 | ||
RJSG18195R | 8.0 × 195 | ||
RJSG18210R | 8.0 × 210 | ||
RJSG18225R | 8.0 × 225 | ||
RJSG18240R | 8.0 × 240 | ||
RJSG18255R | 8.0 × 255 | ||
RJSG17180L | 7.0 × 180 | ||
RJSG17195L | 7.0 × 195 | ||
RJSG17210L | 7.0 × 210 | ||
RJSG17225L | 7.0 × 225 | ||
RJSG17240L | 7.0 × 240 | ||
RJSG17255L | 7.0 × 255 | ||
RJSG18180L | 8.0 × 180 | ||
RJSG18195L | 8.0 × 195 | ||
RJSG18210L | 8.0 × 210 | ||
RJSG18225L | 8.0 × 225 | ||
RJSG18240L | 8.0 × 240 | ||
RJSG18255L | 8.0 × 255 | ||
Ġewż tal-kamin | ![]() | RJSG1WM0 | 0 |
RJSG1WM2 | 2 | ||
RJSG1WM5 | 5 | ||
RJSG1WM10 | 10 | ||
RJSG1WM15 | 15 | ||
Qfil tal-kamin-i | ![]() | RJSG1LD4530 | 4.5 × 30 |
RJSG1LD4532 | 4.5 × 32 | ||
RJSG1LD4534 | 4.5 × 34 | ||
RJSG1LD4536 | 4.5 × 36 | ||
RJSG1LD4538 | 4.5 × 38 | ||
RJSG1LD4540 | 4.5 × 40 | ||
RJSG1LD4542 | 4.5 × 42 | ||
RJSG1LD4544 | 4.5 × 44 | ||
RJSG1LD4546 | 4.5 × 46 | ||
RJSG1LD4548 | 4.5 × 48 | ||
RJSG1LD4550 | 4.5 × 50 | ||
RJSG1LD4552 | 4.5 × 52 | ||
RJSG1LD4554 | 4.5 × 54 | ||
RJSG1LD4556 | 4.5 × 56 | ||
RJSG1LD4558 | 4.5 × 58 | ||
RJSG1LD4560 | 4.5 × 60 | ||
Locking Screw-II | ![]() | RJSG1LD3526 | 3.5 × 26 |
RJSG1LD3528 | 3.5 × 28 | ||
RJSG1LD3530 | 3.5 × 30 | ||
RJSG1LD3532 | 3.5 × 32 | ||
RJSG1LD3534 | 3.5 × 34 | ||
RJSG1LD3536 | 3.5 × 36 | ||
RJSG1LD3538 | 3.5 × 38 | ||
RJSG1LD3540 | 3.5 × 40 | ||
RJSG1LD3542 | 3.5 × 42 | ||
RJSG1LD3544 | 3.5 × 44 | ||
RJSG1LD3546 | 3.5 × 46 | ||
RJSG1LD3548 | 3.5 × 48 | ||
RJSG1LD3550 | 3.5 × 50 | ||
Qfil tal-kamin-III | ![]() | RJSG1LD4018 | 4.0 × 18 |
RJSG1LD4020 | 4.0 × 20 | ||
RJSG1LD4022 | 4.0 × 22 | ||
RJSG1LD4024 | 4.0 × 24 | ||
RJSG1LD4026 | 4.0 × 26 | ||
RJSG1LD4028 | 4.0 × 28 | ||
RJSG1LD4030 | 4.0 × 30 | ||
RJSG1LD4032 | 4.0 × 32 | ||
RJSG1LD4034 | 4.0 × 34 | ||
RJSG1LD4036 | 4.0 × 36 | ||
RJSG1LD4038 | 4.0 × 38 | ||
RJSG1LD4040 | 4.0 × 40 | ||
RJSG1LD4042 | 4.0 × 42 | ||
RJSG1LD4044 | 4.0 × 44 | ||
RJSG1LD4046 | 4.0 × 46 | ||
RJSG1LD4048 | 4.0 × 48 | ||
RJSG1LD4050 | 4.0 × 50 | ||
RJSG1LD4052 | 4.0 × 52 | ||
RJSG1LD4054 | 4.0 × 54 | ||
RJSG1LD4056 | 4.0 × 56 | ||
RJSG1LD4058 | 4.0 × 58 | ||
RJSG1LD4060 | 4.0 × 60 |
1. Disinn tad-dwiefer li jwaqqaf għall-punt ta 'inserzjoni ċentrali.
|
Ipproċessar preliminari tas-CNC It-teknoloġija tal-kontroll numeriku tal-kompjuter tintuża biex tipproċessa b'mod preċiż il-prodotti ortopediċi. Dan il-proċess għandu l-karatteristiċi ta 'preċiżjoni għolja, effiċjenza għolja, u ripetibilità. Jista 'jipproduċi malajr apparat mediku apposta li jikkonforma mal-istruttura anatomika umana u jipprovdi lill-pazjenti bi pjanijiet ta' trattament personalizzati. | Illustrar tal-prodott L-iskop tal-illustrar tal-prodotti ortopediċi huwa li jtejjeb il-kuntatt bejn l-impjant u t-tessut uman, inaqqas il-konċentrazzjoni tal-istress, u jtejjeb l-istabbiltà fit-tul tal-impjant. | Spezzjoni tal-kwalità It-test tal-proprjetajiet mekkaniċi tal-prodotti ortopediċi huwa ddisinjat biex jissimula l-kundizzjonijiet tal-istress tal-għadam tal-bniedem, jevalwa l-kapaċità li jġorr it-tagħbija u d-durabilità tal-impjanti fil-ġisem tal-bniedem, u jiżgura s-sigurtà u l-affidabbiltà tagħhom. |
Pakkett tal-prodott Prodotti ortopediċi huma ppakkjati f'kamra sterili biex jiżguraw li l-prodott ikun inkapsulat f'ambjent nadif u sterili biex jipprevjeni kontaminazzjoni mikrobjali u jiżgura s-sigurtà kirurġika. |
Il-ħażna ta 'prodotti ortopediċi teħtieġ ġestjoni stretta u kontroll tal-kwalità biex tiżgura traċċabilità tal-prodott u tevita l-iskadenza jew il-vjeġġ ħażin. |
Il-kamra tal-kampjun tintuża biex taħżen, turi u timmaniġġja diversi kampjuni ta 'prodotti ortopediċi għal skambji u taħriġ tat-teknoloġija tal-prodott. |
1. Staqsi lit-tim ta 'xc medico għal katalgu ta' prodotti tad-dwiefer intramedullarju multi-lock.
2. Agħżel il-prodott tad-dwiefer intramedullari multi-lock tiegħek interessat.
3. Itlob kampjun biex tittestja l-kwalità tad-dwiefer intramedullarju multi-lock.
4. Agħmel ordni tad-dwiefer intramedullary multi-lock ta 'XC Medico.
5.Become Negozjant tad-dwiefer intramedullary multi-lock ta 'XC Medico.
1. Aħjar ix-xiri tal-prezzijiet tad-dwiefer intramedullari multi-lock humerus.
2.100% L-ogħla kwalità multi-lock humerus intramedullary dwiefer.
3. Inqas sforzi li jordnaw.
4. Stabbiltà tal-prezz għall-perjodu ta 'ftehim.
5. Dwiefer intramedullari suffiċjenti multi-lock.
6. Valutazzjoni rapida u faċli tad-dwiefer intramedullary multi-lock ta 'XC Medico.
7. Marka rikonoxxuta globalment - xc medico.
8. Ħin ta 'aċċess mgħaġġel għat-Tim tal-Bejgħ Medico XC.
9. Test ta 'kwalità addizzjonali mit-tim Medico XC.
10. Traċċar l-ordni xc medico tiegħek mill-bidu sat-tmiem.
Id-dwiefer intramedullarju multi-lock tal-humerus huwa impjant kirurġiku ddisinjat biex jistabbilizza ksur tal-għadam tal-humerus fid-driegħ ta 'fuq. Hija virga twila u rqaq magħmula minn titanju jew azzar li ma jissaddadx li huwa mdaħħal fil-kavità medullari tal-humerus. Id-dwiefer huwa mwaħħal fil-post bil-viti li jsakkru li huma mdaħħla fl-għadam u d-dwiefer innifsu.
Id-dwiefer tinkludi diversi punti ta 'qfil prossimali u distali li jipprovdu fissazzjoni sigura. Din il-karatteristika tippermetti flessibilità fl-immaniġġjar ta 'diversi tipi ta' ksur, inklużi fratturi trasversali, oblikwi u komdi.
B'disinn ergonomiku li jiffaċilita l-faċilità ta 'inserzjoni u pożizzjonament, id-dwiefer inaqqas il-ħin kirurġiku u jippermetti allinjament preċiż ma' aġġustamenti minimi.
Mibnija minn titanju ta 'grad għoli, id-dwiefer huwa ħafif, reżistenti għall-korrużjoni, u bijokompatibbli, magħmul minn materjali bijokompatibbli li huma tollerati sew mill-ġisem, li jnaqqsu r-riskju ta' kumplikazzjonijiet wara l-operazzjoni u jiżguraw lonġevità.
Tnaqqas ir-riskju ta 'irritazzjoni u infezzjoni fit-tessuti.
Is-sistema b'ħafna locking tipprovdi stabbiltà mtejba, tnaqqas ir-riskju ta 'instabilità rotazzjonali u tiżgura fissazzjoni ta' ksur sigura, partikolarment ta 'benefiċċju fil-ksur tal-konsumatur.
In-natura minimament invażiva tagħha tnaqqas it-tfixkil tat-tessut artab, li tirriżulta f'uġigħ inqas wara l-operazzjoni, riskju aktar baxx ta 'infezzjoni, u rkupru aktar mgħaġġel għall-pazjenti.
Il-pazjenti spiss jerġgħu jiksbu l-mobilità aktar kmieni minħabba l-kapaċitajiet ta 'qsim tat-tagħbija tad-dwiefer, li jappoġġjaw il-piż bikri, essenzjali għat-tnaqqis ta' kumplikazzjonijiet assoċjati ma 'immobilizzazzjoni fit-tul.
Il-kompatibilità tagħha ma 'xejriet ta' ksur differenti u anatomji humeral tagħmilha għażla versatili għal kirurgi ta 'trawma, li tiżgura rati ta' suċċess għoljin f'firxa ta 'każijiet.
Inkluż storja medika dettaljata, eżami fiżiku, eżami tal-immaġini (X-ray, CT, eċċ.) Biex tevalwa t-tip u l-grad ta 'ksur u l-kundizzjoni tat-tessut artab tal-madwar.
Skond id-dejta tal-immaġini, pjan kirurġiku dettaljat huwa fformulat, inkluża l-għażla tal-approċċ, mudell tad-dwiefer intramedullari, numru u pożizzjoni tal-viti tal-illokkjar, eċċ.
Blokk tal-plexus brachial jew anestesija ġenerali normalment jintużaw.
Dan huwa l-aktar approċċ użat komunement, permezz tal-inċiżjoni fuq il-muskolu tad-deltojd anterjuri, l-humerus prossimali huwa espost.
Għal xi tipi speċjali ta 'ksur, jistgħu jkunu meħtieġa approċċi oħra, bħall-approċċ subkorakojdi.
Taħt il-gwida ta 'magna tar-raġġi X-arm C, il-frammenti tal-għadam miksura huma mnaqqsa għall-pożizzjoni anatomika permezz ta' manipulazzjoni jew bl-għajnuna ta 'strumenti.
Għal fratturi kumplessi, tnaqqis miftuħ jista 'jkun meħtieġ permezz ta' inċiżjoni żgħira.
Il-kavità medullari hija mkabbra gradwalment bl-użu ta 'kavità medullari biex takkomoda d-dijametru tad-dwiefer intramedullari.
Taħt il-gwida tal-magna tar-raġġi X-arm C, il-labra gwida tiddaħħal fil-kavità medullari mir-ras humeral jew it-tuberosità akbar sat-tarf distali tal-frattura.
Daħħal id-dwiefer intramedullari tul il-labra gwida sakemm tasal il-pożizzjoni predeterminata.
Taħt il-gwida tal-magna tar-raġġi X-arm C, toqba hija mtaqqba fir-ras humeral jew tuberosità akbar permezz ta 'kmiem speċjali tat-tħaffir, u mbagħad tiddaħħal kamin li jsakkar.
Ħaffer toqba fit-tarf distali tal-ksur u daħħal kamin tal-illokkjar.
Tisħiħ tal-kamin: In-numru ta 'viti tal-illokkjar jista' jiżdied skont it-tip u l-istabbiltà tal-ksur.
Wara emostasi bir-reqqa, it-tessut artab huwa magħluq saff.
Poġġi tubu tad-drenaġġ jekk meħtieġ.
Faxxa l-ferita bi dressing sterili.
Wara l-operazzjoni, il-parti affettwata ġeneralment teħtieġ li tiġi ffissata fuq faxxa trijangulari jew tuża brace ta 'l-ispalla.
Eżerċizzji funzjonali tal-ġog ta 'l-ispalla jibdew kmieni wara l-operazzjoni biex tevita ebusija konġunta.
Biex tiġi evitata l-infezzjoni, l-antibijotiċi jingħataw wara l-operazzjoni.
Segwitu regolari biex tissorvelja l-fejqan tal-ksur.
Għalkemm rari, il-migrazzjoni tad-dwiefer tista 'sseħħ jekk mhux imsakkra sew, u għalhekk il-kirurgi għandhom jivverifikaw li l-punti kollha tal-illokkjar huma involuti sewwa waqt il-kirurġija.
Protokolli ta 'sterilizzazzjoni xierqa għandhom jiġu segwiti b'mod rigoruż biex jipprevjenu infezzjonijiet wara l-operazzjoni, speċjalment minħabba n-natura minimament invażiva tal-proċedura.
L-użu ta 'forza kkontrollata waqt l-inserzjoni jgħin biex jiġi evitat it-tifrik tal-għadam jew it-twessigħ eċċessiv tal-kanal, li jista' jwassal għal kumplikazzjonijiet jew fejqan imdewwem.
L-NSAIDs u dawk li jtaffu l-uġigħ oħra huma komunement użati biex jimmaniġġjaw uġigħ wara l-operazzjoni, b'terapiji addizzjonali kif meħtieġ biex jiżgura l-kumdità tal-pazjent.
Terapija fiżika sorveljata tista 'tiġi introdotta wara 4-6 ġimgħat biex terġa' tiġi stabbilita s-saħħa tal-muskoli, il-flessibilità u l-firxa tal-moviment, li tgħin lill-pazjent jerġa 'jikseb funzjoni tad-driegħ normali.
Il-pazjenti huma avżati biex jaraw sinjali ta 'infezzjoni fis-sit tal-inċiżjoni, bħal ħmura jew nefħa, u biex isegwu check-ups regolari.
Immaġni regolari titmexxa biex tiġi rintraċċata l-fejqan tal-għadam u tiżgura li d-dwiefer tibqa 'fil-pożizzjoni t-tajba, li hija kruċjali għal irkupru ta' suċċess.
L-iskeda ta ’żmien għar-ritorn għal attivitajiet normali tvarja skont il-ksur speċifiku, ir-rata ta’ fejqan individwali, u l-proċedura kirurġika. Huwa essenzjali li ssegwi l-parir tal-kirurgu tiegħek u tevita attività fiżika eċċessiva matul il-fażi ta 'fejqan inizjali. Hekk kif l-għadam ifieq, tista 'gradwalment iżżid il-livell ta' attività tiegħek, inklużi firxa ġentili ta 'eżerċizzji ta' moviment u eżerċizzji ta 'tisħiħ.
Is-suq futur għad-dwiefer intramedullari multi-lock tal-humerus huwa mwassal, immexxi minn avvanzi fit-teknoloġiji ortopediċi, żieda fid-domanda għal soluzzjonijiet minimament invażivi, u espansjoni fis-swieq emerġenti.
Id-dwiefer intramedullari multi-lock tal-humerus huma impjanti kirurġiċi effettivi għall-istabbilizzazzjoni tal-ksur tal-humerus. Huma joffru bosta vantaġġi, inkluż invażività minima, fejqan aktar mgħaġġel, u riżultati funzjonali mtejba. Madankollu, huwa importanti li tifhem ir-riskji u l-kumplikazzjonijiet potenzjali assoċjati ma 'din il-proċedura. Billi jsegwu tekniki kirurġiċi xierqa u kura wara l-operazzjoni, il-pazjenti jistgħu jiksbu fejqan u rkupru ottimali.
Tifkira sħuna: Dan l-artikolu huwa għal referenza biss u ma jistax jissostitwixxi l-parir professjonali tat-tabib. Jekk għandek xi mistoqsijiet, jekk jogħġbok ikkonsulta lit-tabib li jattendi tiegħek.
Prodotti | Stampa | Mudelli speċifiċi | Speċifikazzjoni |
HUMERUS MULTI Lock intramedullary Dwiefer | ![]() | RJSG18160R | 8.0 × 160r |
RJSG18160L | 8.0 × 160L | ||
RJSG19160R | 9.0 × 160R | ||
RJSG19160L | 9.0 × 160L | ||
RJSG17180R | 7.0 × 180 | ||
RJSG17195R | 7.0 × 195 | ||
RJSG17210R | 7.0 × 210 | ||
RJSG17225R | 7.0 × 225 | ||
RJSG17240R | 7.0 × 240 | ||
RJSG17255R | 7.0 × 255 | ||
RJSG18180R | 8.0 × 180 | ||
RJSG18195R | 8.0 × 195 | ||
RJSG18210R | 8.0 × 210 | ||
RJSG18225R | 8.0 × 225 | ||
RJSG18240R | 8.0 × 240 | ||
RJSG18255R | 8.0 × 255 | ||
RJSG17180L | 7.0 × 180 | ||
RJSG17195L | 7.0 × 195 | ||
RJSG17210L | 7.0 × 210 | ||
RJSG17225L | 7.0 × 225 | ||
RJSG17240L | 7.0 × 240 | ||
RJSG17255L | 7.0 × 255 | ||
RJSG18180L | 8.0 × 180 | ||
RJSG18195L | 8.0 × 195 | ||
RJSG18210L | 8.0 × 210 | ||
RJSG18225L | 8.0 × 225 | ||
RJSG18240L | 8.0 × 240 | ||
RJSG18255L | 8.0 × 255 | ||
Ġewż tal-kamin | ![]() | RJSG1WM0 | 0 |
RJSG1WM2 | 2 | ||
RJSG1WM5 | 5 | ||
RJSG1WM10 | 10 | ||
RJSG1WM15 | 15 | ||
Qfil tal-kamin-i | ![]() | RJSG1LD4530 | 4.5 × 30 |
RJSG1LD4532 | 4.5 × 32 | ||
RJSG1LD4534 | 4.5 × 34 | ||
RJSG1LD4536 | 4.5 × 36 | ||
RJSG1LD4538 | 4.5 × 38 | ||
RJSG1LD4540 | 4.5 × 40 | ||
RJSG1LD4542 | 4.5 × 42 | ||
RJSG1LD4544 | 4.5 × 44 | ||
RJSG1LD4546 | 4.5 × 46 | ||
RJSG1LD4548 | 4.5 × 48 | ||
RJSG1LD4550 | 4.5 × 50 | ||
RJSG1LD4552 | 4.5 × 52 | ||
RJSG1LD4554 | 4.5 × 54 | ||
RJSG1LD4556 | 4.5 × 56 | ||
RJSG1LD4558 | 4.5 × 58 | ||
RJSG1LD4560 | 4.5 × 60 | ||
Locking Screw-II | ![]() | RJSG1LD3526 | 3.5 × 26 |
RJSG1LD3528 | 3.5 × 28 | ||
RJSG1LD3530 | 3.5 × 30 | ||
RJSG1LD3532 | 3.5 × 32 | ||
RJSG1LD3534 | 3.5 × 34 | ||
RJSG1LD3536 | 3.5 × 36 | ||
RJSG1LD3538 | 3.5 × 38 | ||
RJSG1LD3540 | 3.5 × 40 | ||
RJSG1LD3542 | 3.5 × 42 | ||
RJSG1LD3544 | 3.5 × 44 | ||
RJSG1LD3546 | 3.5 × 46 | ||
RJSG1LD3548 | 3.5 × 48 | ||
RJSG1LD3550 | 3.5 × 50 | ||
Qfil tal-kamin-III | ![]() | RJSG1LD4018 | 4.0 × 18 |
RJSG1LD4020 | 4.0 × 20 | ||
RJSG1LD4022 | 4.0 × 22 | ||
RJSG1LD4024 | 4.0 × 24 | ||
RJSG1LD4026 | 4.0 × 26 | ||
RJSG1LD4028 | 4.0 × 28 | ||
RJSG1LD4030 | 4.0 × 30 | ||
RJSG1LD4032 | 4.0 × 32 | ||
RJSG1LD4034 | 4.0 × 34 | ||
RJSG1LD4036 | 4.0 × 36 | ||
RJSG1LD4038 | 4.0 × 38 | ||
RJSG1LD4040 | 4.0 × 40 | ||
RJSG1LD4042 | 4.0 × 42 | ||
RJSG1LD4044 | 4.0 × 44 | ||
RJSG1LD4046 | 4.0 × 46 | ||
RJSG1LD4048 | 4.0 × 48 | ||
RJSG1LD4050 | 4.0 × 50 | ||
RJSG1LD4052 | 4.0 × 52 | ||
RJSG1LD4054 | 4.0 × 54 | ||
RJSG1LD4056 | 4.0 × 56 | ||
RJSG1LD4058 | 4.0 × 58 | ||
RJSG1LD4060 | 4.0 × 60 |
1. Disinn tad-dwiefer li jwaqqaf għall-punt ta 'inserzjoni ċentrali.
|
Ipproċessar preliminari tas-CNC It-teknoloġija tal-kontroll numeriku tal-kompjuter tintuża biex tipproċessa b'mod preċiż il-prodotti ortopediċi. Dan il-proċess għandu l-karatteristiċi ta 'preċiżjoni għolja, effiċjenza għolja, u ripetibilità. Jista 'jipproduċi malajr apparat mediku apposta li jikkonforma mal-istruttura anatomika umana u jipprovdi lill-pazjenti bi pjanijiet ta' trattament personalizzati. | Illustrar tal-prodott L-iskop tal-illustrar tal-prodotti ortopediċi huwa li jtejjeb il-kuntatt bejn l-impjant u t-tessut uman, inaqqas il-konċentrazzjoni tal-istress, u jtejjeb l-istabbiltà fit-tul tal-impjant. | Spezzjoni tal-kwalità It-test tal-proprjetajiet mekkaniċi tal-prodotti ortopediċi huwa ddisinjat biex jissimula l-kundizzjonijiet tal-istress tal-għadam tal-bniedem, jevalwa l-kapaċità li jġorr it-tagħbija u d-durabilità tal-impjanti fil-ġisem tal-bniedem, u jiżgura s-sigurtà u l-affidabbiltà tagħhom. |
Pakkett tal-prodott Prodotti ortopediċi huma ppakkjati f'kamra sterili biex jiżguraw li l-prodott ikun inkapsulat f'ambjent nadif u sterili biex jipprevjeni kontaminazzjoni mikrobjali u jiżgura s-sigurtà kirurġika. |
Il-ħażna ta 'prodotti ortopediċi teħtieġ ġestjoni stretta u kontroll tal-kwalità biex tiżgura traċċabilità tal-prodott u tevita l-iskadenza jew il-vjeġġ ħażin. |
Il-kamra tal-kampjun tintuża biex taħżen, turi u timmaniġġja diversi kampjuni ta 'prodotti ortopediċi għal skambji u taħriġ tat-teknoloġija tal-prodott. |
1. Staqsi lit-tim ta 'xc medico għal katalgu ta' prodotti tad-dwiefer intramedullarju multi-lock.
2. Agħżel il-prodott tad-dwiefer intramedullari multi-lock tiegħek interessat.
3. Itlob kampjun biex tittestja l-kwalità tad-dwiefer intramedullarju multi-lock.
4. Agħmel ordni tad-dwiefer intramedullary multi-lock ta 'XC Medico.
5.Become Negozjant tad-dwiefer intramedullary multi-lock ta 'XC Medico.
1. Aħjar ix-xiri tal-prezzijiet tad-dwiefer intramedullari multi-lock humerus.
2.100% L-ogħla kwalità multi-lock humerus intramedullary dwiefer.
3. Inqas sforzi li jordnaw.
4. Stabbiltà tal-prezz għall-perjodu ta 'ftehim.
5. Dwiefer intramedullari suffiċjenti multi-lock.
6. Valutazzjoni rapida u faċli tad-dwiefer intramedullary multi-lock ta 'XC Medico.
7. Marka rikonoxxuta globalment - xc medico.
8. Ħin ta 'aċċess mgħaġġel għat-Tim tal-Bejgħ Medico XC.
9. Test ta 'kwalità addizzjonali mit-tim Medico XC.
10. Traċċar l-ordni xc medico tiegħek mill-bidu sat-tmiem.
Id-dwiefer intramedullarju multi-lock tal-humerus huwa impjant kirurġiku ddisinjat biex jistabbilizza ksur tal-għadam tal-humerus fid-driegħ ta 'fuq. Hija virga twila u rqaq magħmula minn titanju jew azzar li ma jissaddadx li huwa mdaħħal fil-kavità medullari tal-humerus. Id-dwiefer huwa mwaħħal fil-post bil-viti li jsakkru li huma mdaħħla fl-għadam u d-dwiefer innifsu.
Id-dwiefer tinkludi diversi punti ta 'qfil prossimali u distali li jipprovdu fissazzjoni sigura. Din il-karatteristika tippermetti flessibilità fl-immaniġġjar ta 'diversi tipi ta' ksur, inklużi fratturi trasversali, oblikwi u komdi.
B'disinn ergonomiku li jiffaċilita l-faċilità ta 'inserzjoni u pożizzjonament, id-dwiefer inaqqas il-ħin kirurġiku u jippermetti allinjament preċiż ma' aġġustamenti minimi.
Mibnija minn titanju ta 'grad għoli, id-dwiefer huwa ħafif, reżistenti għall-korrużjoni, u bijokompatibbli, magħmul minn materjali bijokompatibbli li huma tollerati sew mill-ġisem, li jnaqqsu r-riskju ta' kumplikazzjonijiet wara l-operazzjoni u jiżguraw lonġevità.
Tnaqqas ir-riskju ta 'irritazzjoni u infezzjoni fit-tessuti.
Is-sistema b'ħafna locking tipprovdi stabbiltà mtejba, tnaqqas ir-riskju ta 'instabilità rotazzjonali u tiżgura fissazzjoni ta' ksur sigura, partikolarment ta 'benefiċċju fil-ksur tal-konsumatur.
In-natura minimament invażiva tagħha tnaqqas it-tfixkil tat-tessut artab, li tirriżulta f'uġigħ inqas wara l-operazzjoni, riskju aktar baxx ta 'infezzjoni, u rkupru aktar mgħaġġel għall-pazjenti.
Il-pazjenti spiss jerġgħu jiksbu l-mobilità aktar kmieni minħabba l-kapaċitajiet ta 'qsim tat-tagħbija tad-dwiefer, li jappoġġjaw il-piż bikri, essenzjali għat-tnaqqis ta' kumplikazzjonijiet assoċjati ma 'immobilizzazzjoni fit-tul.
Il-kompatibilità tagħha ma 'xejriet ta' ksur differenti u anatomji humeral tagħmilha għażla versatili għal kirurgi ta 'trawma, li tiżgura rati ta' suċċess għoljin f'firxa ta 'każijiet.
Inkluż storja medika dettaljata, eżami fiżiku, eżami tal-immaġini (X-ray, CT, eċċ.) Biex tevalwa t-tip u l-grad ta 'ksur u l-kundizzjoni tat-tessut artab tal-madwar.
Skond id-dejta tal-immaġini, pjan kirurġiku dettaljat huwa fformulat, inkluża l-għażla tal-approċċ, mudell tad-dwiefer intramedullari, numru u pożizzjoni tal-viti tal-illokkjar, eċċ.
Blokk tal-plexus brachial jew anestesija ġenerali normalment jintużaw.
Dan huwa l-aktar approċċ użat komunement, permezz tal-inċiżjoni fuq il-muskolu tad-deltojd anterjuri, l-humerus prossimali huwa espost.
Għal xi tipi speċjali ta 'ksur, jistgħu jkunu meħtieġa approċċi oħra, bħall-approċċ subkorakojdi.
Taħt il-gwida ta 'magna tar-raġġi X-arm C, il-frammenti tal-għadam miksura huma mnaqqsa għall-pożizzjoni anatomika permezz ta' manipulazzjoni jew bl-għajnuna ta 'strumenti.
Għal fratturi kumplessi, tnaqqis miftuħ jista 'jkun meħtieġ permezz ta' inċiżjoni żgħira.
Il-kavità medullari hija mkabbra gradwalment bl-użu ta 'kavità medullari biex takkomoda d-dijametru tad-dwiefer intramedullari.
Taħt il-gwida tal-magna tar-raġġi X-arm C, il-labra gwida tiddaħħal fil-kavità medullari mir-ras humeral jew it-tuberosità akbar sat-tarf distali tal-frattura.
Daħħal id-dwiefer intramedullari tul il-labra gwida sakemm tasal il-pożizzjoni predeterminata.
Taħt il-gwida tal-magna tar-raġġi X-arm C, toqba hija mtaqqba fir-ras humeral jew tuberosità akbar permezz ta 'kmiem speċjali tat-tħaffir, u mbagħad tiddaħħal kamin li jsakkar.
Ħaffer toqba fit-tarf distali tal-ksur u daħħal kamin tal-illokkjar.
Tisħiħ tal-kamin: In-numru ta 'viti tal-illokkjar jista' jiżdied skont it-tip u l-istabbiltà tal-ksur.
Wara emostasi bir-reqqa, it-tessut artab huwa magħluq saff.
Poġġi tubu tad-drenaġġ jekk meħtieġ.
Faxxa l-ferita bi dressing sterili.
Wara l-operazzjoni, il-parti affettwata ġeneralment teħtieġ li tiġi ffissata fuq faxxa trijangulari jew tuża brace ta 'l-ispalla.
Eżerċizzji funzjonali tal-ġog ta 'l-ispalla jibdew kmieni wara l-operazzjoni biex tevita ebusija konġunta.
Biex tiġi evitata l-infezzjoni, l-antibijotiċi jingħataw wara l-operazzjoni.
Segwitu regolari biex tissorvelja l-fejqan tal-ksur.
Għalkemm rari, il-migrazzjoni tad-dwiefer tista 'sseħħ jekk mhux imsakkra sew, u għalhekk il-kirurgi għandhom jivverifikaw li l-punti kollha tal-illokkjar huma involuti sewwa waqt il-kirurġija.
Protokolli ta 'sterilizzazzjoni xierqa għandhom jiġu segwiti b'mod rigoruż biex jipprevjenu infezzjonijiet wara l-operazzjoni, speċjalment minħabba n-natura minimament invażiva tal-proċedura.
L-użu ta 'forza kkontrollata waqt l-inserzjoni jgħin biex jiġi evitat it-tifrik tal-għadam jew it-twessigħ eċċessiv tal-kanal, li jista' jwassal għal kumplikazzjonijiet jew fejqan imdewwem.
L-NSAIDs u dawk li jtaffu l-uġigħ oħra huma komunement użati biex jimmaniġġjaw uġigħ wara l-operazzjoni, b'terapiji addizzjonali kif meħtieġ biex jiżgura l-kumdità tal-pazjent.
Terapija fiżika sorveljata tista 'tiġi introdotta wara 4-6 ġimgħat biex terġa' tiġi stabbilita s-saħħa tal-muskoli, il-flessibilità u l-firxa tal-moviment, li tgħin lill-pazjent jerġa 'jikseb funzjoni tad-driegħ normali.
Il-pazjenti huma avżati biex jaraw sinjali ta 'infezzjoni fis-sit tal-inċiżjoni, bħal ħmura jew nefħa, u biex isegwu check-ups regolari.
Immaġni regolari titmexxa biex tiġi rintraċċata l-fejqan tal-għadam u tiżgura li d-dwiefer tibqa 'fil-pożizzjoni t-tajba, li hija kruċjali għal irkupru ta' suċċess.
L-iskeda ta ’żmien għar-ritorn għal attivitajiet normali tvarja skont il-ksur speċifiku, ir-rata ta’ fejqan individwali, u l-proċedura kirurġika. Huwa essenzjali li ssegwi l-parir tal-kirurgu tiegħek u tevita attività fiżika eċċessiva matul il-fażi ta 'fejqan inizjali. Hekk kif l-għadam ifieq, tista 'gradwalment iżżid il-livell ta' attività tiegħek, inklużi firxa ġentili ta 'eżerċizzji ta' moviment u eżerċizzji ta 'tisħiħ.
Is-suq futur għad-dwiefer intramedullari multi-lock tal-humerus huwa mwassal, immexxi minn avvanzi fit-teknoloġiji ortopediċi, żieda fid-domanda għal soluzzjonijiet minimament invażivi, u espansjoni fis-swieq emerġenti.
Id-dwiefer intramedullari multi-lock tal-humerus huma impjanti kirurġiċi effettivi għall-istabbilizzazzjoni tal-ksur tal-humerus. Huma joffru bosta vantaġġi, inkluż invażività minima, fejqan aktar mgħaġġel, u riżultati funzjonali mtejba. Madankollu, huwa importanti li tifhem ir-riskji u l-kumplikazzjonijiet potenzjali assoċjati ma 'din il-proċedura. Billi jsegwu tekniki kirurġiċi xierqa u kura wara l-operazzjoni, il-pazjenti jistgħu jiksbu fejqan u rkupru ottimali.
Tifkira sħuna: Dan l-artikolu huwa għal referenza biss u ma jistax jissostitwixxi l-parir professjonali tat-tabib. Jekk għandek xi mistoqsijiet, jekk jogħġbok ikkonsulta lit-tabib li jattendi tiegħek.
Kuntatt