J006
XcMedico
1 tk (72 tundi kohaletoimetamine)
Titaansulam
CE/ISO: 9001/ISO13485.ETC
Eritellimusel valmistatud 15-päevane kohaletoimetamine (välja arvatud saatmisaja)
FedEx. Dhl.tnt.ems.etc
Saadavus: | |
---|---|
Kogus: | |
BC STEM | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3510-02090 | 9 | 135 | 33.8 | 135 | Cocrmo | Lõhkamine | |
3510-02100 | 10 | 135 | 34.5 | ||||
3510-02110 | 11 | 135 | 35.3 | ||||
3510-02120 | 12 | 140 | 36 | ||||
3510-02130 | 13 | 145 | 36.8 | ||||
3510-02140 | 14 | 150 | 37.5 | ||||
3510-02150 | 15 | 150 | 38.3 | ||||
![]() |
|||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() |
3511-01090 | 9 | 130 | 33.8 | 135 | Cocrmo | Lihvitud | |
3511-01100 | 10 | 130 | 34.5 | ||||
3511-01110 | 11 | 135 | 35.3 | ||||
3511-01120 | 12 | 140 | 36 | ||||
3511-01130 | 13 | 145 | 36.8 | ||||
3511-01140 | 14 | 150 | 37.5 | ||||
3511-01150 | 15 | 155 | 38.3 | ||||
BC2 vars | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3512-02090 | 9 | 180 | 33 | 135 | Cocrmo | Lõhkamine | |
3512-02100 | 10 | 190 | 33 | ||||
3512-02110 | 11 | 200 | 33 | ||||
3512-02120 | 12 | 210 | 34 | ||||
3512-02130 | 13 | 220 | 34 | ||||
3512-02140 | 14 | 230 | 35 | ||||
3512-02150 | 15 | 240 | 35 | ||||
BC3 vars | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3516-03070 | 7 | 125 | 30.4 | 135 | Cocrmo | Lõhkamine | |
3516-03080 | 8 | 130 | 31.7 | ||||
3516-03090 | 9 | 135 | 33 | ||||
3516-03100 | 10 | 140 | 34.3 | ||||
3516-03110 | 11 | 145 | 35.6 | ||||
3516-03120 | 12 | 150 | 36.9 | ||||
3516-03130 | 13 | 155 | 38.2 | ||||
3516-03140 | 14 | 160 | 39.5 | ||||
BC4 vars | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3513-03080 | 8 | 115 | 38.4 | 135 | Cocrmo | Lihvitud | |
3513-03090 | 9 | 130 | 38.9 | ||||
3513-03100 | 10 | 140 | 39.8 | ||||
3513-03110 | 11 | 145 | 40.7 | ||||
3513-03120 | 12 | 150 | 41.3 | ||||
3513-03130 | 13 | 155 | 42.2 | ||||
3513-03140 | 14 | 160 | 43.1 | ||||
3513-03150 | 15 | 165 | 44 | ||||
3513-03160 | 16 | 170 | 44.8 | ||||
3513-03170 | 17 | 180 | 45.6 |
CNC esialgne töötlemine Arvuti numbrilist juhtimistehnoloogiat kasutatakse ortopeediliste toodete täpseks töötlemiseks. Sellel protsessil on kõrge täpsuse, suure efektiivsuse ja korratavuse omadused. See võib kiiresti toota kohandatud meditsiiniseadmeid, mis vastavad inimese anatoomilisele struktuurile ja pakkuda patsientidele isikupärastatud raviplaane. |
Toote poleerimine Ortopeediliste toodete poleerimise eesmärk on parandada implantaadi ja inimkudede vahelist kontakti, vähendada stressi kontsentratsiooni ja parandada implantaadi pikaajalist stabiilsust. |
Kvaliteedikontroll Ortopeediliste toodete mehaaniliste omaduste test on loodud simuleerimiseks inimese luude pingetingimustest, hindamiseks inimkehas implantaatide koormuse kandmisvõimet ja vastupidavust ning tagama nende turvalisuse ja usaldusväärsuse. |
Tootepakett Ortopeedilised tooted on pakendatud steriilsesse ruumi, et tagada toode puhtasse ja steriilsesse keskkonda, et vältida mikroobide saastumist ja tagada kirurgiline ohutus. |
Ortopeediliste toodete ladustamine nõuab ranget sisse- ja väljajuhtimis- ja kvaliteedikontrolli, et tagada toodete jälgitavus ja vältida aegumist või valet saatmist. |
Prooviruumi kasutatakse erinevate ortopeediliste toodete proovide hoidmiseks, kuvamiseks ja haldamiseks tootetehnoloogia vahetamiseks ja koolituseks. |
1. Küsige XC Medico meeskonnalt tsementeeritud puusaproduktide kataloogi.
2. Valige oma huvitatud tsementeeritud redaktsiooni puusatoode.
3. Paluge proovile tsementeeritud redaktsiooni puusa testimiseks.
4. Tehke XC Medico tsementeeritud redaktsiooni puusa tellimus.
5.Become XC Medico tsementeeritud revisjoni puusa edasimüüja.
1. tsementeeritud revisjoni puusade ostuhinnad.
2,100% kõrgeima kvaliteediga tsementeeritud redaktsiooni puusa.
3. Vähem tellimispüüdlusi.
4. kokkuleppeperioodi hinnastabiilsus.
5. Piisav tsementeeritud redaktsiooni puusa.
6. XC Medico tsementeeritud redaktsiooni puusa kiire ja lihtne hindamine.
7. Globaalselt tunnustatud bränd - XC Medico.
8. Kiire juurdepääsu aeg XC Medico müügimeeskonnale.
9. XC Medico meeskonna täiendav kvaliteeditest.
10. Jälgige oma XC Medico tellimust algusest lõpuni.
Tsementeeritud puusaimplantaadid on kriitiline lahendus puusaprimaarsete asendamise tüsistuste või tõrkete käsitlemisel. Need implantaadid kasutavad proteesi kindlustamiseks luutsementi, tagades stabiilsuse ja funktsionaalsuse isegi kahjustatud luukvaliteediga patsientidel. See artikkel pakub tsementeeritud revisjoni puusade põhjalikku uurimist, kirjeldades nende omadusi, eeliseid, ravirakendusi ja tulevikuväljavaateid, pakkudes väärtuslikku teavet ortopeedilistele spetsialistidele, patsientidele ja meditsiiniuurijatele.
Tsementeeritud revisjoniimplantaat on puusaliigese artroplastika revisjonis kasutatav proteesi tüüp ebaõnnestunud või problemaatilise primaarse puusa asendamise asendamiseks või parandamiseks. Erinevalt tsemendita kujundustest tuginevad tsementeeritud implantaadid polümetüülmetakrülaadi (PMMA) luutsemendile, et siduda implantaat luu külge, pakkudes viivitamatut stabiilsust. See lähenemisviis on eriti kasulik halva luukvaliteediga patsientidele, näiteks osteoporoosiga patsientidele või raske luukaotusele.
Tsementeeritud redaktsiooni puusad on loodud puusafunktsiooni taastamiseks, valu leevendamiseks ja vastupidava tuge pakkumiseks. Neid kasutatakse sageli juhtudel, kui bioloogiline fikseerimine läbi osseointegratsiooni (nagu nähtub tsemendita implantaatides) ei ole teostatav.
PMMA -tsemendi kasutamine täidab tühimike luu ja implantaadi vahel, pakkudes viivitamatut ja tugevat fikseerimist.
Paljud tsementeeritud süsteemid hõlmavad moodulpead, varte ja atsetakulaarseid komponente, mis võimaldavad kirurgidel implantaadi kohandada vastavalt patsiendi anatoomiale.
Poleeritud varrekujundused vähendavad hõõrdumist ja kulumist, minimeerides aja jooksul lõdvenemise või ebaõnnestumise riski.
Koobalt-kromiumsulamitest või titaanist konstrueeritud tsementeeritud implantaadid on korrosiooni ja kulumise suhtes väga vastupidavad.
Varredel on sageli reieluukanalis hõlpsamaks sisestamiseks ja paremaks jaotus.
PMMA luutsement on radiopakk, mis võimaldab kirurgidel visualiseerida implantaadi ja tsemendi kihti operatsiooni ajal ja pärast röntgenikiirte abil.
Mõned komponendid hõlmavad karendatud või liivaga plahvatatud pindu, et parandada tsemendi järgimist ja vähendada mikroliikumist.
Luutsement tagab, et implantaat saavutab kohese stabiilsuse, välistades implantaadi kinnitamiseks luude kasvu vajaduse. See on eriti kasulik halva luukvaliteediga patsientidele.
Tsementeeritud disainilahendused mahutavad mitmesuguseid patsiente, sealhulgas oluliste luukadude, luumurdude või haigusseisunditega patsiente, mis kahjustavad bioloogilist fikseerimist, näiteks osteoporoosi.
PMMA-tsemendiga loodud tugev side minimeerib mikromotsiooni implantaadi luude liidesel, vähendades lõdvenemise või kulumisega seotud komplikatsioonide riski.
Implantaadi ebaõnnestumise või nakkuse tõttu läbivaatamise operatsioonil läbivaatavate patsientide jaoks pakuvad tsementeeritud implantaadid usaldusväärset ja etteaimatavat lahendust isegi ohustatud luude tingimustes.
Luutsemendi radiopakett võimaldab implantaadi positsiooni ja tsemendikihi hõlpsalt jälgida operatsioonijärgset jälgimist, võimaldades tüsistuste varajast avastamist.
Üks levinumaid põhjuseid revisjonioperatsioonil - tsementeeritud implantaadid käsitlevad primaarsete implantaatide lõdvenemist, pakkudes viivitamatut ja stabiilset fikseerimist.
Varasema implantaadi, eriti vanematel patsientidel, luumurdusid stabiliseeritakse sageli tsementeeritud komponentide abil tõhusalt.
Kulumisprahist põhjustatud luuresorptsiooni saab vastu võtta tsementeeritud implantaatidega, mis kompenseerivad luukadu.
Juhtudel, kui nakkus on primaarset implantaati ohustanud, saab nakkuse kontrollimiseks kasutada koos antibiootikumiga koormatud tsemendi kõrval tsementeeritud redaktsiooni.
Raske luukaduga patsientide jaoks pakuvad tsementeeritud implantaadid tugevat tuge, mis ei pruugi olla tsemendivate võimalustega saavutatavad.
Luutsement võib põhjustada haruldasi komplikatsioone, näiteks tsemendiemboolia, kus tsemendi osakesed sisenevad vereringesse ja põhjustada ummistusi.
PMMA eksotermiline reaktsioon seadistamise ajal võib tekitada soojust, kahjustades ümbritsevat luukoe.
Kuigi tsement tagab kohese stabiilsuse, võib pikaajaline lõdvenemine toimuda, eriti kui tsemendi side nõrgeneb.
BCIS hõlmab harvaesinevat, kuid tõsist komplikatsiooni hüpotensiooni, hüpoksiat või südameprobleeme tsemendi kasutamise ajal või pärast seda.
Tsementeeritud implantaatide muutmine võib olla keerukam, kuna vajadus eemaldada karastatud tsement, kahjustamata järelejäänud luu.
Nagu iga kirurgilise protseduuri puhul, on ka operatsioonijärgse infektsiooni oht, mis võib nõuda täiendavaid operatsioone või ravi.
Globaalse elanikkonna vanuses tõuseb puusaliigese asendamise ja sellele järgnenud paranduste esinemissagedus, põhjustades tsementeeritud implantaatide nõudlust.
Uuendused PMMA preparaatides, näiteks antibiootikumiga koormatud ja bioaktiivsed tsemendid, parandavad tsementeeritud implantaatide jõudlust ja ohutust.
Kirurgid pooldavad sageli tsementeeritud implantaate halva luukvaliteedi või olulise luukaotusega patsientidele, tagades jätkuva nõudluse.
Tervishoiuinfrastruktuuri kasv Aasia-Vaikse ookeani, Ladina-Ameerikas ja Lähis-Idas loodetakse nendes piirkondades tsementeeritud implantaatide vastuvõtmist.
Pidev teadus- ja arendustegevus on keskendunud implantaadi kujundamise, tsemendi koostiste ja kirurgiliste tehnikate parandamisele, et parandada tulemusi ja vähendada komplikatsioone.
Tsementeeritud redaktsiooni implantaat on tänapäevase ortopeedilise kirurgia nurgakivi, eriti kahjustatud luukvaliteedi või keerukate revisjonivajadustega patsientide jaoks. Selliste funktsioonide nagu vahetu stabiilsus, kõrge mitmekülgsus ja kohanemisvõime mitmesuguste luumurdudega, pakuvad need implantaadid usaldusväärseid tulemusi nii patsientidele kui ka kirurgidele. Kuigi on olemasolevaid riske, jätkavad implantaadimaterjalide, tsemendi koostiste ja kirurgiliste tehnikate edusammud komplikatsioone ja parandavad tulemusi.
Kuna nõudlus puusa revisjonioperatsioonide järele kasvab globaalselt, on tsementeeritud redaktsiooni puusal püsimine ortopeedilise ravi kriitiliseks vahendiks, pakkudes keerukate puusaprotseduuridega patsientide stabiilsust, funktsionaalsust ja paremat elukvaliteeti.
Soe meeldetuletus: see artikkel on mõeldud ainult ja ei saa asendada arsti ametialast nõu. Kui teil on küsimusi, pöörduge oma arsti poole.
BC STEM | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3510-02090 | 9 | 135 | 33.8 | 135 | Cocrmo | Lõhkamine | |
3510-02100 | 10 | 135 | 34.5 | ||||
3510-02110 | 11 | 135 | 35.3 | ||||
3510-02120 | 12 | 140 | 36 | ||||
3510-02130 | 13 | 145 | 36.8 | ||||
3510-02140 | 14 | 150 | 37.5 | ||||
3510-02150 | 15 | 150 | 38.3 | ||||
![]() |
|||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() |
3511-01090 | 9 | 130 | 33.8 | 135 | Cocrmo | Lihvitud | |
3511-01100 | 10 | 130 | 34.5 | ||||
3511-01110 | 11 | 135 | 35.3 | ||||
3511-01120 | 12 | 140 | 36 | ||||
3511-01130 | 13 | 145 | 36.8 | ||||
3511-01140 | 14 | 150 | 37.5 | ||||
3511-01150 | 15 | 155 | 38.3 | ||||
BC2 vars | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3512-02090 | 9 | 180 | 33 | 135 | Cocrmo | Lõhkamine | |
3512-02100 | 10 | 190 | 33 | ||||
3512-02110 | 11 | 200 | 33 | ||||
3512-02120 | 12 | 210 | 34 | ||||
3512-02130 | 13 | 220 | 34 | ||||
3512-02140 | 14 | 230 | 35 | ||||
3512-02150 | 15 | 240 | 35 | ||||
BC3 vars | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3516-03070 | 7 | 125 | 30.4 | 135 | Cocrmo | Lõhkamine | |
3516-03080 | 8 | 130 | 31.7 | ||||
3516-03090 | 9 | 135 | 33 | ||||
3516-03100 | 10 | 140 | 34.3 | ||||
3516-03110 | 11 | 145 | 35.6 | ||||
3516-03120 | 12 | 150 | 36.9 | ||||
3516-03130 | 13 | 155 | 38.2 | ||||
3516-03140 | 14 | 160 | 39.5 | ||||
BC4 vars | |||||||
Kood | Suurus | Varre pikkus | Kortsus | Kaelanurk | Matt. | Kate | ![]() ![]() |
3513-03080 | 8 | 115 | 38.4 | 135 | Cocrmo | Lihvitud | |
3513-03090 | 9 | 130 | 38.9 | ||||
3513-03100 | 10 | 140 | 39.8 | ||||
3513-03110 | 11 | 145 | 40.7 | ||||
3513-03120 | 12 | 150 | 41.3 | ||||
3513-03130 | 13 | 155 | 42.2 | ||||
3513-03140 | 14 | 160 | 43.1 | ||||
3513-03150 | 15 | 165 | 44 | ||||
3513-03160 | 16 | 170 | 44.8 | ||||
3513-03170 | 17 | 180 | 45.6 |
CNC esialgne töötlemine Arvuti numbrilist juhtimistehnoloogiat kasutatakse ortopeediliste toodete täpseks töötlemiseks. Sellel protsessil on kõrge täpsuse, suure efektiivsuse ja korratavuse omadused. See võib kiiresti toota kohandatud meditsiiniseadmeid, mis vastavad inimese anatoomilisele struktuurile ja pakkuda patsientidele isikupärastatud raviplaane. |
Toote poleerimine Ortopeediliste toodete poleerimise eesmärk on parandada implantaadi ja inimkudede vahelist kontakti, vähendada stressi kontsentratsiooni ja parandada implantaadi pikaajalist stabiilsust. |
Kvaliteedikontroll Ortopeediliste toodete mehaaniliste omaduste test on loodud simuleerimiseks inimese luude pingetingimustest, hindamiseks inimkehas implantaatide koormuse kandmisvõimet ja vastupidavust ning tagama nende turvalisuse ja usaldusväärsuse. |
Tootepakett Ortopeedilised tooted on pakendatud steriilsesse ruumi, et tagada toode puhtasse ja steriilsesse keskkonda, et vältida mikroobide saastumist ja tagada kirurgiline ohutus. |
Ortopeediliste toodete ladustamine nõuab ranget sisse- ja väljajuhtimis- ja kvaliteedikontrolli, et tagada toodete jälgitavus ja vältida aegumist või valet saatmist. |
Prooviruumi kasutatakse erinevate ortopeediliste toodete proovide hoidmiseks, kuvamiseks ja haldamiseks tootetehnoloogia vahetamiseks ja koolituseks. |
1. Küsige XC Medico meeskonnalt tsementeeritud puusaproduktide kataloogi.
2. Valige oma huvitatud tsementeeritud redaktsiooni puusatoode.
3. Paluge proovile tsementeeritud redaktsiooni puusa testimiseks.
4. Tehke XC Medico tsementeeritud redaktsiooni puusa tellimus.
5.Become XC Medico tsementeeritud revisjoni puusa edasimüüja.
1. tsementeeritud revisjoni puusade ostuhinnad.
2,100% kõrgeima kvaliteediga tsementeeritud redaktsiooni puusa.
3. Vähem tellimispüüdlusi.
4. kokkuleppeperioodi hinnastabiilsus.
5. Piisav tsementeeritud redaktsiooni puusa.
6. XC Medico tsementeeritud redaktsiooni puusa kiire ja lihtne hindamine.
7. Globaalselt tunnustatud bränd - XC Medico.
8. Kiire juurdepääsu aeg XC Medico müügimeeskonnale.
9. XC Medico meeskonna täiendav kvaliteeditest.
10. Jälgige oma XC Medico tellimust algusest lõpuni.
Tsementeeritud puusaimplantaadid on kriitiline lahendus puusaprimaarsete asendamise tüsistuste või tõrkete käsitlemisel. Need implantaadid kasutavad proteesi kindlustamiseks luutsementi, tagades stabiilsuse ja funktsionaalsuse isegi kahjustatud luukvaliteediga patsientidel. See artikkel pakub tsementeeritud revisjoni puusade põhjalikku uurimist, kirjeldades nende omadusi, eeliseid, ravirakendusi ja tulevikuväljavaateid, pakkudes väärtuslikku teavet ortopeedilistele spetsialistidele, patsientidele ja meditsiiniuurijatele.
Tsementeeritud revisjoniimplantaat on puusaliigese artroplastika revisjonis kasutatav proteesi tüüp ebaõnnestunud või problemaatilise primaarse puusa asendamise asendamiseks või parandamiseks. Erinevalt tsemendita kujundustest tuginevad tsementeeritud implantaadid polümetüülmetakrülaadi (PMMA) luutsemendile, et siduda implantaat luu külge, pakkudes viivitamatut stabiilsust. See lähenemisviis on eriti kasulik halva luukvaliteediga patsientidele, näiteks osteoporoosiga patsientidele või raske luukaotusele.
Tsementeeritud redaktsiooni puusad on loodud puusafunktsiooni taastamiseks, valu leevendamiseks ja vastupidava tuge pakkumiseks. Neid kasutatakse sageli juhtudel, kui bioloogiline fikseerimine läbi osseointegratsiooni (nagu nähtub tsemendita implantaatides) ei ole teostatav.
PMMA -tsemendi kasutamine täidab tühimike luu ja implantaadi vahel, pakkudes viivitamatut ja tugevat fikseerimist.
Paljud tsementeeritud süsteemid hõlmavad moodulpead, varte ja atsetakulaarseid komponente, mis võimaldavad kirurgidel implantaadi kohandada vastavalt patsiendi anatoomiale.
Poleeritud varrekujundused vähendavad hõõrdumist ja kulumist, minimeerides aja jooksul lõdvenemise või ebaõnnestumise riski.
Koobalt-kromiumsulamitest või titaanist konstrueeritud tsementeeritud implantaadid on korrosiooni ja kulumise suhtes väga vastupidavad.
Varredel on sageli reieluukanalis hõlpsamaks sisestamiseks ja paremaks jaotus.
PMMA luutsement on radiopakk, mis võimaldab kirurgidel visualiseerida implantaadi ja tsemendi kihti operatsiooni ajal ja pärast röntgenikiirte abil.
Mõned komponendid hõlmavad karendatud või liivaga plahvatatud pindu, et parandada tsemendi järgimist ja vähendada mikroliikumist.
Luutsement tagab, et implantaat saavutab kohese stabiilsuse, välistades implantaadi kinnitamiseks luude kasvu vajaduse. See on eriti kasulik halva luukvaliteediga patsientidele.
Tsementeeritud disainilahendused mahutavad mitmesuguseid patsiente, sealhulgas oluliste luukadude, luumurdude või haigusseisunditega patsiente, mis kahjustavad bioloogilist fikseerimist, näiteks osteoporoosi.
PMMA-tsemendiga loodud tugev side minimeerib mikromotsiooni implantaadi luude liidesel, vähendades lõdvenemise või kulumisega seotud komplikatsioonide riski.
Implantaadi ebaõnnestumise või nakkuse tõttu läbivaatamise operatsioonil läbivaatavate patsientide jaoks pakuvad tsementeeritud implantaadid usaldusväärset ja etteaimatavat lahendust isegi ohustatud luude tingimustes.
Luutsemendi radiopakett võimaldab implantaadi positsiooni ja tsemendikihi hõlpsalt jälgida operatsioonijärgset jälgimist, võimaldades tüsistuste varajast avastamist.
Üks levinumaid põhjuseid revisjonioperatsioonil - tsementeeritud implantaadid käsitlevad primaarsete implantaatide lõdvenemist, pakkudes viivitamatut ja stabiilset fikseerimist.
Varasema implantaadi, eriti vanematel patsientidel, luumurdusid stabiliseeritakse sageli tsementeeritud komponentide abil tõhusalt.
Kulumisprahist põhjustatud luuresorptsiooni saab vastu võtta tsementeeritud implantaatidega, mis kompenseerivad luukadu.
Juhtudel, kui nakkus on primaarset implantaati ohustanud, saab nakkuse kontrollimiseks kasutada koos antibiootikumiga koormatud tsemendi kõrval tsementeeritud redaktsiooni.
Raske luukaduga patsientide jaoks pakuvad tsementeeritud implantaadid tugevat tuge, mis ei pruugi olla tsemendivate võimalustega saavutatavad.
Luutsement võib põhjustada haruldasi komplikatsioone, näiteks tsemendiemboolia, kus tsemendi osakesed sisenevad vereringesse ja põhjustada ummistusi.
PMMA eksotermiline reaktsioon seadistamise ajal võib tekitada soojust, kahjustades ümbritsevat luukoe.
Kuigi tsement tagab kohese stabiilsuse, võib pikaajaline lõdvenemine toimuda, eriti kui tsemendi side nõrgeneb.
BCIS hõlmab harvaesinevat, kuid tõsist komplikatsiooni hüpotensiooni, hüpoksiat või südameprobleeme tsemendi kasutamise ajal või pärast seda.
Tsementeeritud implantaatide muutmine võib olla keerukam, kuna vajadus eemaldada karastatud tsement, kahjustamata järelejäänud luu.
Nagu iga kirurgilise protseduuri puhul, on ka operatsioonijärgse infektsiooni oht, mis võib nõuda täiendavaid operatsioone või ravi.
Globaalse elanikkonna vanuses tõuseb puusaliigese asendamise ja sellele järgnenud paranduste esinemissagedus, põhjustades tsementeeritud implantaatide nõudlust.
Uuendused PMMA preparaatides, näiteks antibiootikumiga koormatud ja bioaktiivsed tsemendid, parandavad tsementeeritud implantaatide jõudlust ja ohutust.
Kirurgid pooldavad sageli tsementeeritud implantaate halva luukvaliteedi või olulise luukaotusega patsientidele, tagades jätkuva nõudluse.
Tervishoiuinfrastruktuuri kasv Aasia-Vaikse ookeani, Ladina-Ameerikas ja Lähis-Idas loodetakse nendes piirkondades tsementeeritud implantaatide vastuvõtmist.
Pidev teadus- ja arendustegevus on keskendunud implantaadi kujundamise, tsemendi koostiste ja kirurgiliste tehnikate parandamisele, et parandada tulemusi ja vähendada komplikatsioone.
Tsementeeritud redaktsiooni implantaat on tänapäevase ortopeedilise kirurgia nurgakivi, eriti kahjustatud luukvaliteedi või keerukate revisjonivajadustega patsientide jaoks. Selliste funktsioonide nagu vahetu stabiilsus, kõrge mitmekülgsus ja kohanemisvõime mitmesuguste luumurdudega, pakuvad need implantaadid usaldusväärseid tulemusi nii patsientidele kui ka kirurgidele. Kuigi on olemasolevaid riske, jätkavad implantaadimaterjalide, tsemendi koostiste ja kirurgiliste tehnikate edusammud komplikatsioone ja parandavad tulemusi.
Kuna nõudlus puusa revisjonioperatsioonide järele kasvab globaalselt, on tsementeeritud redaktsiooni puusal püsimine ortopeedilise ravi kriitiliseks vahendiks, pakkudes keerukate puusaprotseduuridega patsientide stabiilsust, funktsionaalsust ja paremat elukvaliteeti.
Soe meeldetuletus: see artikkel on mõeldud ainult ja ei saa asendada arsti ametialast nõu. Kui teil on küsimusi, pöörduge oma arsti poole.
Sisu on tühi!