J006
Xcmedico
1 pcs (72 jam pengiriman)
Paduan Titanium
CE/ISO: 9001/ISO13485.ETC
Pengiriman 15 hari yang dibuat khusus (Tidak termasuk waktu pengiriman)
Fedex. Dhl.tnt.ems.etc
Tersedianya: | |
---|---|
Kuantitas: | |
BC STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3510-02090 | 9 | 135 | 33.8 | 135 | Cocrmo | Ledakan | |
3510-02100 | 10 | 135 | 34.5 | ||||
3510-02110 | 11 | 135 | 35.3 | ||||
3510-02120 | 12 | 140 | 36 | ||||
3510-02130 | 13 | 145 | 36.8 | ||||
3510-02140 | 14 | 150 | 37.5 | ||||
3510-02150 | 15 | 150 | 38.3 | ||||
![]() | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() |
3511-01090 | 9 | 130 | 33.8 | 135 | Cocrmo | Dipoles | |
3511-01100 | 10 | 130 | 34.5 | ||||
3511-01110 | 11 | 135 | 35.3 | ||||
3511-01120 | 12 | 140 | 36 | ||||
3511-01130 | 13 | 145 | 36.8 | ||||
3511-01140 | 14 | 150 | 37.5 | ||||
3511-01150 | 15 | 155 | 38.3 | ||||
BC2 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3512-02090 | 9 | 180 | 33 | 135 | Cocrmo | Ledakan | |
3512-02100 | 10 | 190 | 33 | ||||
3512-02110 | 11 | 200 | 33 | ||||
3512-02120 | 12 | 210 | 34 | ||||
3512-02130 | 13 | 220 | 34 | ||||
3512-02140 | 14 | 230 | 35 | ||||
3512-02150 | 15 | 240 | 35 | ||||
BC3 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3516-03070 | 7 | 125 | 30.4 | 135 | Cocrmo | Ledakan | |
3516-03080 | 8 | 130 | 31.7 | ||||
3516-03090 | 9 | 135 | 33 | ||||
3516-03100 | 10 | 140 | 34.3 | ||||
3516-03110 | 11 | 145 | 35.6 | ||||
3516-03120 | 12 | 150 | 36.9 | ||||
3516-03130 | 13 | 155 | 38.2 | ||||
3516-03140 | 14 | 160 | 39.5 | ||||
BC4 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3513-03080 | 8 | 115 | 38.4 | 135 | Cocrmo | Dipoles | |
3513-03090 | 9 | 130 | 38.9 | ||||
3513-03100 | 10 | 140 | 39.8 | ||||
3513-03110 | 11 | 145 | 40.7 | ||||
3513-03120 | 12 | 150 | 41.3 | ||||
3513-03130 | 13 | 155 | 42.2 | ||||
3513-03140 | 14 | 160 | 43.1 | ||||
3513-03150 | 15 | 165 | 44 | ||||
3513-03160 | 16 | 170 | 44.8 | ||||
3513-03170 | 17 | 180 | 45.6 |
Pemrosesan pendahuluan CNC Teknologi kontrol numerik komputer digunakan untuk memproses produk ortopedi secara tepat. Proses ini memiliki karakteristik presisi tinggi, efisiensi tinggi, dan pengulangan. Ini dapat dengan cepat menghasilkan perangkat medis khusus yang sesuai dengan struktur anatomi manusia dan memberikan pasien dengan rencana perawatan yang dipersonalisasi. | Pemolesan produk Tujuan pemolesan produk ortopedi adalah untuk meningkatkan kontak antara implan dan jaringan manusia, mengurangi konsentrasi stres, dan meningkatkan stabilitas jangka panjang implan. | Inspeksi Kualitas Uji sifat mekanik produk ortopedi dirancang untuk mensimulasikan kondisi stres tulang manusia, mengevaluasi kapasitas penahan beban dan daya tahan implan dalam tubuh manusia, dan memastikan keamanan dan keandalannya. |
Paket produk Produk ortopedi dikemas di ruang steril untuk memastikan bahwa produk dienkapsulasi dalam lingkungan yang bersih dan steril untuk mencegah kontaminasi mikroba dan memastikan keamanan bedah. |
Penyimpanan produk ortopedi membutuhkan manajemen masuk-dan-keluar yang ketat dan kontrol kualitas untuk memastikan keterlacakan produk dan mencegah kedaluwarsa atau pengiriman yang salah. |
Ruang sampel digunakan untuk menyimpan, menampilkan, dan mengelola berbagai sampel produk ortopedi untuk pertukaran dan pelatihan teknologi produk. |
1. Mintalah tim XC Medico untuk katalog produk HIP revisi yang disemen.
2. Pilih produk Hip Revision yang Anda minati.
3. Mintalah sampel untuk menguji pinggul revisi semen.
4. Buat pesanan hip revisi semen XC Medico.
5. Berdasarkan dealer HIP revisi semen XC Medico.
1. Harga pembelian lebih baik dari HIP revisi semen.
2,100% Pinggul revisi semen berkualitas tinggi.
3. Upaya pemesanan yang lebih sedikit.
4. Stabilitas harga untuk periode perjanjian.
5. Pinggul revisi semen yang cukup.
6. Penilaian cepat dan mudah dari pinggul revisi semen XC Medico.
7. Merek yang diakui secara global - XC Medico.
8. Waktu akses cepat ke tim penjualan XC Medico.
9. Tes kualitas tambahan oleh tim XC Medico.
10. Lacak pesanan XC Medico Anda dari awal hingga akhir.
Implan pinggul revisi semen adalah solusi penting dalam mengatasi komplikasi atau kegagalan penggantian pinggul primer. Implan ini menggunakan semen tulang untuk mengamankan prostesis, memastikan stabilitas dan fungsionalitas bahkan pada pasien dengan kualitas tulang yang terganggu. Artikel ini memberikan eksplorasi mendalam tentang pinggul revisi yang disemen, merinci fitur mereka, keunggulan, aplikasi perawatan, dan prospek masa depan, menawarkan wawasan berharga bagi para profesional ortopedi, pasien, dan peneliti medis.
Implan pinggul revisi semen adalah jenis prostesis yang digunakan dalam revisi artroplasti pinggul untuk mengganti atau memperbaiki penggantian pinggul primer yang gagal atau bermasalah. Tidak seperti desain tanpa semen, implan semen mengandalkan semen tulang polymethylmethacrylate (PMMA) untuk mengikat implan ke tulang, memberikan stabilitas langsung. Pendekatan ini sangat bermanfaat bagi pasien dengan kualitas tulang yang buruk, seperti mereka yang memiliki osteoporosis atau kehilangan tulang yang parah.
Hip revisi semen dirancang untuk mengembalikan fungsi pinggul, mengurangi rasa sakit, dan memberikan dukungan yang tahan lama. Mereka sering digunakan dalam kasus di mana fiksasi biologis melalui osseointegrasi (seperti yang terlihat pada implan tanpa semen) tidak layak.
Penggunaan semen PMMA mengisi rongga antara tulang dan implan, memberikan fiksasi langsung dan kuat.
Banyak sistem semen termasuk kepala modular, batang, dan komponen asetabular, memungkinkan ahli bedah untuk menyesuaikan implan agar sesuai dengan anatomi pasien.
Desain batang yang dipoles mengurangi gesekan dan keausan, meminimalkan risiko pelonggaran atau kegagalan dari waktu ke waktu.
Dibangun dari paduan kobalt-kromium atau titanium, implan semen sangat tahan terhadap korosi dan keausan.
Batang sering menampilkan desain meruncing untuk penyisipan yang lebih mudah dan distribusi beban yang lebih baik di dalam kanal femoralis.
Semen tulang PMMA adalah radiopaque, memungkinkan ahli bedah untuk memvisualisasikan lapisan implan dan semen selama dan setelah operasi menggunakan sinar-X.
Beberapa komponen termasuk permukaan yang kasar atau diledakkan untuk meningkatkan kepatuhan semen dan mengurangi gerak mikro.
Semen tulang memastikan bahwa implan mencapai stabilitas instan, menghilangkan kebutuhan akan pertumbuhan tulang untuk mengamankan implan. Ini sangat bermanfaat bagi pasien dengan kualitas tulang yang buruk.
Desain semen dapat mengakomodasi berbagai pasien, termasuk mereka yang memiliki keropos tulang yang signifikan, patah tulang, atau kondisi yang mengganggu fiksasi biologis, seperti osteoporosis.
Ikatan kuat yang dibuat oleh semen PMMA meminimalkan micromotion pada antarmuka tulang implan, mengurangi risiko melonggarkan atau komplikasi terkait keausan.
Untuk pasien yang menjalani operasi revisi karena kegagalan atau infeksi implan, implan semen memberikan solusi yang andal dan dapat diprediksi, bahkan dalam kondisi tulang yang terganggu.
Sifat radiopaque dari semen tulang memungkinkan pemantauan pasca operasi yang mudah dari posisi implan dan lapisan semen, memungkinkan deteksi dini komplikasi.
Salah satu alasan paling umum untuk operasi revisi, implan semen mengatasi pelonggaran implan primer dengan memberikan fiksasi langsung dan stabil.
Fraktur di sekitar implan sebelumnya, terutama pada pasien yang lebih tua, sering distabilkan secara efektif menggunakan komponen semen.
Resorpsi tulang yang disebabkan oleh puing -puing keausan dapat dilawan dengan implan semen yang mengimbangi keropos tulang.
Dalam kasus di mana infeksi telah mengganggu implan utama, pinggul revisi semen dapat digunakan bersama semen yang dimuat antibiotik untuk kontrol infeksi.
Untuk pasien dengan keropos tulang yang parah, implan semen memberikan dukungan yang kuat yang mungkin tidak dapat dicapai dengan pilihan tanpa semen.
Semen tulang dapat menyebabkan komplikasi langka seperti emboli semen, di mana partikel semen memasuki aliran darah dan menyebabkan penyumbatan.
Reaksi eksotermik PMMA selama pengaturan dapat menghasilkan panas, berpotensi merusak jaringan tulang di sekitarnya.
Sementara semen memberikan stabilitas langsung, pelonggaran jangka panjang dapat terjadi, terutama jika ikatan semen melemah.
Komplikasi yang jarang tetapi serius, BCIS melibatkan hipotensi, hipoksia, atau masalah jantung selama atau setelah aplikasi semen.
Revisi implan semen bisa lebih kompleks karena kebutuhan untuk menghilangkan semen yang dikeraskan tanpa merusak tulang yang tersisa.
Seperti halnya prosedur bedah apa pun, ada risiko infeksi pasca operasi, yang mungkin memerlukan operasi atau perawatan tambahan.
Seiring bertambahnya usia populasi global, insiden penggantian pinggul dan revisi selanjutnya akan meningkat, mendorong permintaan untuk implan yang semen.
Inovasi dalam formulasi PMMA, seperti semen yang dimuat antibiotik dan bioaktif, meningkatkan kinerja dan keamanan implan semen.
Ahli bedah sering mendukung implan semen untuk pasien dengan kualitas tulang yang buruk atau keropos tulang yang signifikan, memastikan permintaan berkelanjutan.
Pertumbuhan infrastruktur perawatan kesehatan di Asia-Pasifik, Amerika Latin, dan Timur Tengah diperkirakan akan mendorong adopsi implan semen di wilayah ini.
R&D yang sedang berlangsung difokuskan pada peningkatan desain implan, formulasi semen, dan teknik bedah untuk meningkatkan hasil dan mengurangi komplikasi.
Implan pinggul revisi semen tetap merupakan landasan operasi ortopedi modern, terutama untuk pasien dengan kualitas tulang yang terganggu atau kebutuhan revisi yang kompleks. Dengan fitur -fitur seperti stabilitas langsung, fleksibilitas tinggi, dan kemampuan beradaptasi dengan berbagai jenis fraktur, implan ini memberikan hasil yang dapat diandalkan untuk pasien dan ahli bedah. Meskipun ada risiko yang melekat, kemajuan dalam bahan implan, formulasi semen, dan teknik bedah terus meminimalkan komplikasi dan meningkatkan hasil.
Ketika permintaan untuk operasi revisi pinggul tumbuh secara global, hip revisi yang disemen siap untuk tetap menjadi alat penting dalam perawatan ortopedi, menawarkan stabilitas, fungsionalitas, dan peningkatan kualitas hidup bagi pasien yang menjalani prosedur pinggul yang kompleks.
Pengingat Hangat: Artikel ini hanya untuk referensi dan tidak dapat menggantikan saran profesional dokter. Jika Anda memiliki pertanyaan, silakan berkonsultasi dengan dokter yang hadir.
BC STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3510-02090 | 9 | 135 | 33.8 | 135 | Cocrmo | Ledakan | |
3510-02100 | 10 | 135 | 34.5 | ||||
3510-02110 | 11 | 135 | 35.3 | ||||
3510-02120 | 12 | 140 | 36 | ||||
3510-02130 | 13 | 145 | 36.8 | ||||
3510-02140 | 14 | 150 | 37.5 | ||||
3510-02150 | 15 | 150 | 38.3 | ||||
![]() | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() |
3511-01090 | 9 | 130 | 33.8 | 135 | Cocrmo | Dipoles | |
3511-01100 | 10 | 130 | 34.5 | ||||
3511-01110 | 11 | 135 | 35.3 | ||||
3511-01120 | 12 | 140 | 36 | ||||
3511-01130 | 13 | 145 | 36.8 | ||||
3511-01140 | 14 | 150 | 37.5 | ||||
3511-01150 | 15 | 155 | 38.3 | ||||
BC2 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3512-02090 | 9 | 180 | 33 | 135 | Cocrmo | Ledakan | |
3512-02100 | 10 | 190 | 33 | ||||
3512-02110 | 11 | 200 | 33 | ||||
3512-02120 | 12 | 210 | 34 | ||||
3512-02130 | 13 | 220 | 34 | ||||
3512-02140 | 14 | 230 | 35 | ||||
3512-02150 | 15 | 240 | 35 | ||||
BC3 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3516-03070 | 7 | 125 | 30.4 | 135 | Cocrmo | Ledakan | |
3516-03080 | 8 | 130 | 31.7 | ||||
3516-03090 | 9 | 135 | 33 | ||||
3516-03100 | 10 | 140 | 34.3 | ||||
3516-03110 | 11 | 145 | 35.6 | ||||
3516-03120 | 12 | 150 | 36.9 | ||||
3516-03130 | 13 | 155 | 38.2 | ||||
3516-03140 | 14 | 160 | 39.5 | ||||
BC4 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3513-03080 | 8 | 115 | 38.4 | 135 | Cocrmo | Dipoles | |
3513-03090 | 9 | 130 | 38.9 | ||||
3513-03100 | 10 | 140 | 39.8 | ||||
3513-03110 | 11 | 145 | 40.7 | ||||
3513-03120 | 12 | 150 | 41.3 | ||||
3513-03130 | 13 | 155 | 42.2 | ||||
3513-03140 | 14 | 160 | 43.1 | ||||
3513-03150 | 15 | 165 | 44 | ||||
3513-03160 | 16 | 170 | 44.8 | ||||
3513-03170 | 17 | 180 | 45.6 |
Pemrosesan pendahuluan CNC Teknologi kontrol numerik komputer digunakan untuk memproses produk ortopedi secara tepat. Proses ini memiliki karakteristik presisi tinggi, efisiensi tinggi, dan pengulangan. Ini dapat dengan cepat menghasilkan perangkat medis khusus yang sesuai dengan struktur anatomi manusia dan memberikan pasien dengan rencana perawatan yang dipersonalisasi. | Pemolesan produk Tujuan pemolesan produk ortopedi adalah untuk meningkatkan kontak antara implan dan jaringan manusia, mengurangi konsentrasi stres, dan meningkatkan stabilitas jangka panjang implan. | Inspeksi Kualitas Uji sifat mekanik produk ortopedi dirancang untuk mensimulasikan kondisi stres tulang manusia, mengevaluasi kapasitas penahan beban dan daya tahan implan dalam tubuh manusia, dan memastikan keamanan dan keandalannya. |
Paket produk Produk ortopedi dikemas di ruang steril untuk memastikan bahwa produk dienkapsulasi dalam lingkungan yang bersih dan steril untuk mencegah kontaminasi mikroba dan memastikan keamanan bedah. |
Penyimpanan produk ortopedi membutuhkan manajemen masuk-dan-keluar yang ketat dan kontrol kualitas untuk memastikan keterlacakan produk dan mencegah kedaluwarsa atau pengiriman yang salah. |
Ruang sampel digunakan untuk menyimpan, menampilkan, dan mengelola berbagai sampel produk ortopedi untuk pertukaran dan pelatihan teknologi produk. |
1. Mintalah tim XC Medico untuk katalog produk HIP revisi yang disemen.
2. Pilih produk Hip Revision yang Anda minati.
3. Mintalah sampel untuk menguji pinggul revisi semen.
4. Buat pesanan hip revisi semen XC Medico.
5. Berdasarkan dealer HIP revisi semen XC Medico.
1. Harga pembelian lebih baik dari HIP revisi semen.
2,100% Pinggul revisi semen berkualitas tinggi.
3. Upaya pemesanan yang lebih sedikit.
4. Stabilitas harga untuk periode perjanjian.
5. Pinggul revisi semen yang cukup.
6. Penilaian cepat dan mudah dari pinggul revisi semen XC Medico.
7. Merek yang diakui secara global - XC Medico.
8. Waktu akses cepat ke tim penjualan XC Medico.
9. Tes kualitas tambahan oleh tim XC Medico.
10. Lacak pesanan XC Medico Anda dari awal hingga akhir.
Implan pinggul revisi semen adalah solusi penting dalam mengatasi komplikasi atau kegagalan penggantian pinggul primer. Implan ini menggunakan semen tulang untuk mengamankan prostesis, memastikan stabilitas dan fungsionalitas bahkan pada pasien dengan kualitas tulang yang terganggu. Artikel ini memberikan eksplorasi mendalam tentang pinggul revisi yang disemen, merinci fitur mereka, keunggulan, aplikasi perawatan, dan prospek masa depan, menawarkan wawasan berharga bagi para profesional ortopedi, pasien, dan peneliti medis.
Implan pinggul revisi semen adalah jenis prostesis yang digunakan dalam revisi artroplasti pinggul untuk mengganti atau memperbaiki penggantian pinggul primer yang gagal atau bermasalah. Tidak seperti desain tanpa semen, implan semen mengandalkan semen tulang polymethylmethacrylate (PMMA) untuk mengikat implan ke tulang, memberikan stabilitas langsung. Pendekatan ini sangat bermanfaat bagi pasien dengan kualitas tulang yang buruk, seperti mereka yang memiliki osteoporosis atau kehilangan tulang yang parah.
Hip revisi semen dirancang untuk mengembalikan fungsi pinggul, mengurangi rasa sakit, dan memberikan dukungan yang tahan lama. Mereka sering digunakan dalam kasus di mana fiksasi biologis melalui osseointegrasi (seperti yang terlihat pada implan tanpa semen) tidak layak.
Penggunaan semen PMMA mengisi rongga antara tulang dan implan, memberikan fiksasi langsung dan kuat.
Banyak sistem semen termasuk kepala modular, batang, dan komponen asetabular, memungkinkan ahli bedah untuk menyesuaikan implan agar sesuai dengan anatomi pasien.
Desain batang yang dipoles mengurangi gesekan dan keausan, meminimalkan risiko pelonggaran atau kegagalan dari waktu ke waktu.
Dibangun dari paduan kobalt-kromium atau titanium, implan semen sangat tahan terhadap korosi dan keausan.
Batang sering menampilkan desain meruncing untuk penyisipan yang lebih mudah dan distribusi beban yang lebih baik di dalam kanal femoralis.
Semen tulang PMMA adalah radiopaque, memungkinkan ahli bedah untuk memvisualisasikan lapisan implan dan semen selama dan setelah operasi menggunakan sinar-X.
Beberapa komponen termasuk permukaan yang kasar atau diledakkan untuk meningkatkan kepatuhan semen dan mengurangi gerak mikro.
Semen tulang memastikan bahwa implan mencapai stabilitas instan, menghilangkan kebutuhan akan pertumbuhan tulang untuk mengamankan implan. Ini sangat bermanfaat bagi pasien dengan kualitas tulang yang buruk.
Desain semen dapat mengakomodasi berbagai pasien, termasuk mereka yang memiliki keropos tulang yang signifikan, patah tulang, atau kondisi yang mengganggu fiksasi biologis, seperti osteoporosis.
Ikatan kuat yang dibuat oleh semen PMMA meminimalkan micromotion pada antarmuka tulang implan, mengurangi risiko melonggarkan atau komplikasi terkait keausan.
Untuk pasien yang menjalani operasi revisi karena kegagalan atau infeksi implan, implan semen memberikan solusi yang andal dan dapat diprediksi, bahkan dalam kondisi tulang yang terganggu.
Sifat radiopaque dari semen tulang memungkinkan pemantauan pasca operasi yang mudah dari posisi implan dan lapisan semen, memungkinkan deteksi dini komplikasi.
Salah satu alasan paling umum untuk operasi revisi, implan semen mengatasi pelonggaran implan primer dengan memberikan fiksasi langsung dan stabil.
Fraktur di sekitar implan sebelumnya, terutama pada pasien yang lebih tua, sering distabilkan secara efektif menggunakan komponen semen.
Resorpsi tulang yang disebabkan oleh puing -puing keausan dapat dilawan dengan implan semen yang mengimbangi keropos tulang.
Dalam kasus di mana infeksi telah mengganggu implan utama, pinggul revisi semen dapat digunakan bersama semen yang dimuat antibiotik untuk kontrol infeksi.
Untuk pasien dengan keropos tulang yang parah, implan semen memberikan dukungan yang kuat yang mungkin tidak dapat dicapai dengan pilihan tanpa semen.
Semen tulang dapat menyebabkan komplikasi langka seperti emboli semen, di mana partikel semen memasuki aliran darah dan menyebabkan penyumbatan.
Reaksi eksotermik PMMA selama pengaturan dapat menghasilkan panas, berpotensi merusak jaringan tulang di sekitarnya.
Sementara semen memberikan stabilitas langsung, pelonggaran jangka panjang dapat terjadi, terutama jika ikatan semen melemah.
Komplikasi yang jarang tetapi serius, BCIS melibatkan hipotensi, hipoksia, atau masalah jantung selama atau setelah aplikasi semen.
Revisi implan semen bisa lebih kompleks karena kebutuhan untuk menghilangkan semen yang dikeraskan tanpa merusak tulang yang tersisa.
Seperti halnya prosedur bedah apa pun, ada risiko infeksi pasca operasi, yang mungkin memerlukan operasi atau perawatan tambahan.
Seiring bertambahnya usia populasi global, insiden penggantian pinggul dan revisi selanjutnya akan meningkat, mendorong permintaan untuk implan yang semen.
Inovasi dalam formulasi PMMA, seperti semen yang dimuat antibiotik dan bioaktif, meningkatkan kinerja dan keamanan implan semen.
Ahli bedah sering mendukung implan semen untuk pasien dengan kualitas tulang yang buruk atau keropos tulang yang signifikan, memastikan permintaan berkelanjutan.
Pertumbuhan infrastruktur perawatan kesehatan di Asia-Pasifik, Amerika Latin, dan Timur Tengah diperkirakan akan mendorong adopsi implan semen di wilayah ini.
R&D yang sedang berlangsung difokuskan pada peningkatan desain implan, formulasi semen, dan teknik bedah untuk meningkatkan hasil dan mengurangi komplikasi.
Implan pinggul revisi semen tetap merupakan landasan operasi ortopedi modern, terutama untuk pasien dengan kualitas tulang yang terganggu atau kebutuhan revisi yang kompleks. Dengan fitur -fitur seperti stabilitas langsung, fleksibilitas tinggi, dan kemampuan beradaptasi dengan berbagai jenis fraktur, implan ini memberikan hasil yang dapat diandalkan untuk pasien dan ahli bedah. Meskipun ada risiko yang melekat, kemajuan dalam bahan implan, formulasi semen, dan teknik bedah terus meminimalkan komplikasi dan meningkatkan hasil.
Ketika permintaan untuk operasi revisi pinggul tumbuh secara global, hip revisi yang disemen siap untuk tetap menjadi alat penting dalam perawatan ortopedi, menawarkan stabilitas, fungsionalitas, dan peningkatan kualitas hidup bagi pasien yang menjalani prosedur pinggul yang kompleks.
Pengingat Hangat: Artikel ini hanya untuk referensi dan tidak dapat menggantikan saran profesional dokter. Jika Anda memiliki pertanyaan, silakan berkonsultasi dengan dokter yang hadir.