J005
Xcmedico
1 pcs (72 jam pengiriman)
Paduan Titanium
CE/ISO: 9001/ISO13485.ETC
Pengiriman 15 hari yang dibuat khusus (Tidak termasuk waktu pengiriman)
Fedex. Dhl.tnt.ems.etc
Tersedianya: | |
---|---|
Kuantitas: | |
BB STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3311-04090 | 9 | 135 | 33.8 | 135 | Ti6al4v | Ti+ha | |
3311-04100 | 10 | 140 | 34.5 | ||||
3311-04110 | 11 | 145 | 35.2 | ||||
3311-04120 | 12 | 150 | 36 | ||||
3311-04130 | 13 | 155 | 36.8 | ||||
3311-04140 | 14 | 155 | 37.6 | ||||
3311-04150 | 15 | 155 | 38.4 | ||||
3311-04160 | 16 | 160 | 39.2 | ||||
3311-04170 | 17 | 160 | 40.2 | ||||
3311-04180 | 18 | 165 | 41.2 | ||||
145 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3330-01070 | 7 | 130 | 30.4 | 135 | Ti6al4v | tembakan peledakan | |
3330-01080 | 8 | 135 | 31.7 | ||||
3330-01090 | 9 | 140 | 33 | ||||
3330-01100 | 10 | 145 | 34.3 | ||||
3330-01110 | 11 | 150 | 35.6 | ||||
3330-01120 | 12 | 155 | 36.9 | ||||
3330-01130 | 13 | 160 | 38.2 | ||||
3330-01140 | 14 | 165 | 39.5 | ||||
140 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
20 | 9 | 140 | 37.5 | 130 | Ti6al4v | Ti | |
3310-02100 | 10 | 145 | 38 | ||||
3310-02110 | 11 | 150 | 38.5 | ||||
3310-02120 | 12 | 155 | 39 | ||||
3310-02130 | 13 | 160 | 40 | ||||
3310-02140 | 14 | 165 | 41 | ||||
3310-02150 | 15 | 170 | 42 | ||||
Menjadi batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3323-04080 | 8 | 115 | 38.4 | 135 | Ti6al4v | Ti+ha | |
3323-04090 | 9 | 130 | 38.9 | ||||
3323-04100 | 10 | 140 | 39.8 | ||||
3323-04110 | 11 | 145 | 40.7 | ||||
3323-04120 | 12 | 150 | 41.3 | ||||
3323-04130 | 13 | 155 | 42.2 | ||||
3323-04140 | 14 | 160 | 43.1 | ||||
3323-04150 | 15 | 165 | 44 | ||||
3323-04160 | 16 | 170 | 44.8 | ||||
3323-04170 | 17 | 180 | 45.6 | ||||
3323-04180 | 17+ | 190 | 46.3 | ||||
BE2 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
/ | 6 | 110 | 32 | 127 & 133 Versi Dua | Ti6al4v | Ti+ha | |
7 | 115 | 33 | |||||
8 | 120 | 34 | |||||
9 | 125 | 35 | |||||
10 | 130 | 36 | |||||
11 | 135 | 37 | |||||
12 | 140 | 38 | |||||
13 | 145 | 39 | |||||
14 | 150 | 40 | |||||
15 | 155 | 41 | |||||
16 | 160 | 42 | |||||
17 | 165 | 43 | |||||
18 | 170 | 44 | |||||
155 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | Foto. |
3332-02070 | 7 | 120 | 32.3 | 132 | Ti6al4v | ![]() | ![]() |
3332-02080 | 8 | 125 | 33.3 | ||||
3332-02090 | 9 | 130 | 34.3 | ||||
3332-02100 | 10 | 135 | 35.4 | ||||
3332-02110 | 11 | 140 | 36.4 | ||||
3332-02120 | 12 | 145 | 37.6 | ||||
3332-02130 | 13 | 150 | 38.8 | ||||
3332-02140 | 14 | 155 | 39.9 | ||||
3332-02150 | 15 | 160 | 41.1 | ||||
3332-02160 | 16 | 165 | 42.3 | ||||
3332-02170 | 16+ | 170 | 43.5 | ||||
3332-02180 | 16 ++ | 175 | 44.7 |
130 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3320-02060 | 6 | 100 | 32 | 125 | Ti6al4v | Ti | |
3320-02070 | 7 | 100 | 33 | ||||
3320-02080 | 8 | 110 | 34 | ||||
3320-02090 | 9 | 110 | 35 | ||||
3320-02100 | 10 | 120 | 36 | ||||
3320-02110 | 11 | 120 | 37.5 | ||||
3320-02120 | 12 | 130 | 39 | ||||
130 batang panjang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3315-01100 | 10 | 185 & 205 & 220 & 250 | 40 | 135 | Ti6al4v | Ti | |
3315-01110 | 11 | 40 | |||||
3315-01120 | 12 | 41 | |||||
3315-01130 | 13 | 41 | |||||
3315-01140 | 14 | 42 | |||||
3315-01150 | 15 | 42 | |||||
3315-01160 | 16 | 42 | |||||
BE1 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Angl Neck | Tikar. | Lapisan | Foto. |
3331-02060 | 6 | 112 | 40.4 | 132 | Ti6al4v | Ti | ![]() ![]() |
3331-02070 | 7 | 114 | 40.9 | ||||
3331-02080 | 8 | 116 | 41.4 | ||||
3331-02090 | 9 | 120 | 41.9 | ||||
3331-02100 | 10 | 122 | 42.4 | ||||
3331-02110 | 11 | 124 | 43.9 | ||||
3331-02120 | 12 | 126 | 46.9 | ||||
3331-02130 | 13 | 128 | 47.9 | ||||
3331-02140 | 13+ | 130 | 48.4 | ||||
160 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | ![]() | Foto. |
3325-02090 | 9 | 150 | 39 | 130 | Ti6al4v | Ti | ![]() |
3325-02100 | 10 | 39.5 | |||||
3325-02110 | 11 | 40 | |||||
3325-02120 | 12 | 40.5 | |||||
3325-02130 | 13 | 41 | |||||
3325-01240 | 14 | 41.5 | |||||
3325-02150 | 15 | 41.5 | |||||
3325-02160 | 16 | 42 | |||||
3325-02180 | 18 | ||||||
3325-02200 | 20 | 42.5 | |||||
160 batang (200mm panjang, untuk revisi atau fraktur trokanteri) | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | Foto. |
3326-02091 | 9L | 200 | 39 | 130 | Ti6al4v | ![]() | ![]() |
3326-02092 | 9r | ||||||
3326-02101 | 10L | 39.5 | |||||
3326-02102 | 10r | ||||||
3326-02111 | 11L | 40 | |||||
3326-02112 | 11r | ||||||
3326-02121 | 12L | 40.5 | |||||
3326-02122 | 12r | ||||||
3326-02131 | 13L | 41 | |||||
3326-02132 | 13r | ||||||
3326-02141 | 14L | 41.5 | |||||
3326-02142 | 14r | ||||||
3326-02161 | 16L | 42 | |||||
3326-02162 | 16r | ||||||
3326-02181 | 18L | 42.5 | |||||
3326-02182 | 18r | ||||||
3326-02201 | 20L | 43 | |||||
3326-02202 | 20r | ||||||
160 batang (250mm panjang, untuk revisi atau fraktur trokanteri) | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | ![]() | ![]() |
3327-02101 | 10L | 250 | 39.5 | 130 | Ti6al4v | Ti | |
3327-02102 | 10r | ||||||
3327-02121 | 12L | 40.5 | |||||
3327-02122 | 12r | ||||||
3327-02141 | 14L | 41.5 | |||||
3327-02142 | 14r | ||||||
3327-02161 | 16L | 42 | |||||
3327-02162 | 16r | ||||||
3327-02181 | 18L | 42.5 | |||||
3327-02182 | 18r | ||||||
3327-02201 | 20L | 43 | |||||
3327-02202 | 20r |
Pemrosesan pendahuluan CNC Teknologi kontrol numerik komputer digunakan untuk memproses produk ortopedi secara tepat. Proses ini memiliki karakteristik presisi tinggi, efisiensi tinggi, dan pengulangan. Ini dapat dengan cepat menghasilkan perangkat medis khusus yang sesuai dengan struktur anatomi manusia dan memberikan pasien dengan rencana perawatan yang dipersonalisasi. | Pemolesan produk Tujuan pemolesan produk ortopedi adalah untuk meningkatkan kontak antara implan dan jaringan manusia, mengurangi konsentrasi stres, dan meningkatkan stabilitas jangka panjang implan. | Inspeksi Kualitas Uji sifat mekanik produk ortopedi dirancang untuk mensimulasikan kondisi stres tulang manusia, mengevaluasi kapasitas penahan beban dan daya tahan implan dalam tubuh manusia, dan memastikan keamanan dan keandalannya. |
Paket produk Produk ortopedi dikemas di ruang steril untuk memastikan bahwa produk dienkapsulasi dalam lingkungan yang bersih dan steril untuk mencegah kontaminasi mikroba dan memastikan keamanan bedah. |
Penyimpanan produk ortopedi membutuhkan manajemen masuk-dan-keluar yang ketat dan kontrol kualitas untuk memastikan keterlacakan produk dan mencegah kedaluwarsa atau pengiriman yang salah. |
Ruang sampel digunakan untuk menyimpan, menampilkan, dan mengelola berbagai sampel produk ortopedi untuk pertukaran dan pelatihan teknologi produk. |
1. Mintalah tim XC Medico untuk katalog produk HIP revisi tanpa semen.
2. Pilih produk Hip Revision Tanpa Semen yang Anda minati.
3. Mintalah sampel untuk menguji pinggul revisi tanpa semen.
4. Buat pesanan Hip Revisi Tanpa Semen XC Medico.
5. Berdasarkan dealer Hip Revisi Tanpa Semen XC Medico.
1. Harga pembelian lebih baik dari Hip Revisi Tanpa Semen.
2,100% Pinggul revisi tanpa semen berkualitas tinggi.
3. Upaya pemesanan yang lebih sedikit.
4. Stabilitas harga untuk periode perjanjian.
5. Pinggul revisi tanpa semen yang cukup.
6. Penilaian Cepat dan Mudah dari Hip Revisi Tanpa Semen XC Medico.
7. Merek yang diakui secara global - XC Medico.
8. Waktu akses cepat ke tim penjualan XC Medico.
9. Tes kualitas tambahan oleh tim XC Medico.
10. Lacak pesanan XC Medico Anda dari awal hingga akhir.
Implan pinggul revisi tanpa semen merupakan kemajuan vital di bidang bedah ortopedi, terutama dalam mengatasi komplikasi yang terkait dengan penggantian pinggul yang gagal atau usang. Implan ini dirancang untuk meningkatkan mobilitas, mengurangi rasa sakit, dan memulihkan fungsionalitas tanpa menggunakan semen tulang. Panduan ini memberikan gambaran mendalam tentang pinggul revisi tanpa semen, mengeksplorasi fitur, keunggulan, aplikasi, dan potensi pasar di masa depan, melayani para profesional ortopedi dan penggemar medis.
Hip revisi tanpa semen mengacu pada jenis implan pinggul yang dirancang untuk digunakan dalam operasi revisi, di mana implan pinggul yang ditempatkan sebelumnya telah gagal, melonggarkan, atau menyebabkan komplikasi. Tidak seperti implan tradisional yang mengandalkan semen tulang untuk fiksasi, implan tanpa semen mencapai stabilitas melalui fiksasi biologis. Ini difasilitasi oleh permukaan berpori mereka, yang mempromosikan pertumbuhan tulang langsung ke implan, menciptakan ikatan yang tahan lama dan stabil.
Implan ini sangat cocok untuk pasien dengan kualitas tulang yang baik dan mereka yang menjalani prosedur di mana konservasi tulang sangat penting. Desain tanpa semen semakin disukai kemampuannya untuk berintegrasi dengan struktur tulang alami dan mengurangi risiko komplikasi yang terkait dengan implan semen.
Lapisan berpori, sering terbuat dari titanium atau hidroksiapatit, mendorong osseointegrasi, memungkinkan tulang alami tumbuh menjadi implan.
Banyak implan memiliki desain batang yang meruncing untuk mencapai kesesuaian yang aman di kanal femoralis, meningkatkan stabilitas awal.
Desain modular memungkinkan kustomisasi yang lebih besar, memungkinkan ahli bedah untuk menyesuaikan implan dengan anatomi unik dan struktur tulang pasien.
Bahan berkekuatan tinggi seperti paduan titanium biasanya digunakan untuk biokompatibilitasnya yang sangat baik, sifat ringan, dan resistensi korosi.
Desain anatomi meniru kontur alami femur dan acetabulum, meningkatkan stabilitas implan dan kenyamanan pasien.
Sistem tanpa semen sering kali mencakup opsi untuk batang panjang panjang dan ugments asetabular untuk kasus kehilangan tulang yang parah.
Fiksasi biologis memastikan bahwa implan tetap melekat pada tulang dari waktu ke waktu, mengurangi kemungkinan pelonggaran atau kegagalan.
Dengan menghilangkan penggunaan semen tulang, yang dapat berfungsi sebagai situs potensial untuk pertumbuhan bakteri, risiko infeksi pasca operasi diminimalkan.
Desain tanpa semen memungkinkan konservasi tulang, yang sangat bermanfaat pada pasien yang lebih muda yang mungkin memerlukan revisi lebih lanjut di masa depan.
Pertumbuhan tulang alami ke dalam implan meningkatkan distribusi beban dan meminimalkan pelindung tegangan, yang mengarah ke hasil jangka panjang yang lebih baik.
Ahli bedah dapat menyesuaikan implan untuk mengatasi tantangan spesifik, seperti keropos tulang atau kelainan bentuk, meningkatkan hasil bedah.
Pasien sering mengalami waktu pemulihan yang lebih cepat dan meningkatkan mobilitas pasca operasi karena fiksasi alami yang aman yang disediakan oleh implan ini.
Ketika implan pinggul yang ditempatkan sebelumnya kehilangan keterikatannya pada tulang tanpa infeksi, implan tanpa semen menawarkan penggantian yang stabil.
Dalam kasus fraktur di sekitar implan asli, desain tanpa semen dapat mengakomodasi dan menstabilkan kondisi kompleks ini.
Kehilangan tulang yang disebabkan oleh puing -puing keausan dari implan sebelumnya dapat dikurangi dengan penggunaan implan tanpa semen yang mempromosikan regenerasi tulang.
Untuk pasien dengan dislokasi berulang atau sendi pinggul yang tidak stabil, implan revisi tanpa semen mengembalikan keselarasan dan stabilitas yang tepat.
Setelah penghapusan implan terkait infeksi dan pemberantasan infeksi, desain tanpa semen memberikan opsi yang andal untuk implantasi ulang.
Dalam beberapa kasus, tulang alami mungkin membutuhkan waktu lebih lama untuk tumbuh menjadi implan, yang menyebabkan ketidakstabilan sementara.
Pasien dengan kualitas tulang yang buruk, seperti mereka yang memiliki osteoporosis parah, mungkin tidak mencapai fiksasi yang memadai, meningkatkan risiko kegagalan implan.
Prosedur revisi tanpa semen dapat lebih menuntut secara teknis, membutuhkan ahli bedah berpengalaman dan peralatan khusus.
Teknik implantasi yang tidak tepat dapat menyebabkan patah tulang paha atau acetabulum.
Seiring waktu, komponen implan dapat dipakai, memerlukan revisi lebih lanjut.
Implan tanpa semen seringkali lebih mahal daripada pilihan semen, yang dapat membatasi aksesibilitas untuk beberapa pasien.
Seiring bertambahnya usia populasi global, permintaan untuk operasi revisi pinggul diperkirakan akan meningkat, meningkatkan kebutuhan implan yang andal.
Inovasi dalam bahan biokompatibel, seperti pelapis bioaktif dan implan cetak 3D, meningkatkan kinerja sistem tanpa semen.
Preferensi yang berkembang untuk fiksasi biologis di antara ahli bedah memastikan adopsi implan tanpa semen yang berkelanjutan.
Memperluas infrastruktur perawatan kesehatan di daerah seperti Asia-Pasifik dan Amerika Latin menghadirkan peluang yang belum dimanfaatkan untuk pertumbuhan pasar.
Integrasi operasi yang dibantu robot dan alat perencanaan yang digerakkan AI meningkatkan ketepatan prosedur implan tanpa semen.
Pinggul revisi tanpa semen adalah landasan operasi ortopedi modern, menawarkan solusi yang efektif, tahan lama, dan biokompatibel untuk kasus revisi pinggul. Desain inovatifnya mempromosikan integrasi tulang alami, mengurangi risiko yang terkait dengan implan tradisional semen. Sementara tantangan bedah dan faktor spesifik pasien harus dipertimbangkan dengan cermat, keunggulan sistem tanpa semen menjadikannya pilihan yang lebih disukai bagi banyak ahli bedah ortopedi.
Ketika teknologi terus maju dan permintaan global untuk operasi revisi tumbuh, pinggul revisi tanpa semen akan memainkan peran yang semakin vital dalam meningkatkan hasil pasien dan mendefinisikan kembali standar dalam operasi penggantian pinggul.
Pengingat Hangat: Artikel ini hanya untuk referensi dan tidak dapat menggantikan saran profesional dokter. Jika Anda memiliki pertanyaan, silakan berkonsultasi dengan dokter yang hadir.
BB STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3311-04090 | 9 | 135 | 33.8 | 135 | Ti6al4v | Ti+ha | |
3311-04100 | 10 | 140 | 34.5 | ||||
3311-04110 | 11 | 145 | 35.2 | ||||
3311-04120 | 12 | 150 | 36 | ||||
3311-04130 | 13 | 155 | 36.8 | ||||
3311-04140 | 14 | 155 | 37.6 | ||||
3311-04150 | 15 | 155 | 38.4 | ||||
3311-04160 | 16 | 160 | 39.2 | ||||
3311-04170 | 17 | 160 | 40.2 | ||||
3311-04180 | 18 | 165 | 41.2 | ||||
145 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3330-01070 | 7 | 130 | 30.4 | 135 | Ti6al4v | tembakan peledakan | |
3330-01080 | 8 | 135 | 31.7 | ||||
3330-01090 | 9 | 140 | 33 | ||||
3330-01100 | 10 | 145 | 34.3 | ||||
3330-01110 | 11 | 150 | 35.6 | ||||
3330-01120 | 12 | 155 | 36.9 | ||||
3330-01130 | 13 | 160 | 38.2 | ||||
3330-01140 | 14 | 165 | 39.5 | ||||
140 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
20 | 9 | 140 | 37.5 | 130 | Ti6al4v | Ti | |
3310-02100 | 10 | 145 | 38 | ||||
3310-02110 | 11 | 150 | 38.5 | ||||
3310-02120 | 12 | 155 | 39 | ||||
3310-02130 | 13 | 160 | 40 | ||||
3310-02140 | 14 | 165 | 41 | ||||
3310-02150 | 15 | 170 | 42 | ||||
Menjadi batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3323-04080 | 8 | 115 | 38.4 | 135 | Ti6al4v | Ti+ha | |
3323-04090 | 9 | 130 | 38.9 | ||||
3323-04100 | 10 | 140 | 39.8 | ||||
3323-04110 | 11 | 145 | 40.7 | ||||
3323-04120 | 12 | 150 | 41.3 | ||||
3323-04130 | 13 | 155 | 42.2 | ||||
3323-04140 | 14 | 160 | 43.1 | ||||
3323-04150 | 15 | 165 | 44 | ||||
3323-04160 | 16 | 170 | 44.8 | ||||
3323-04170 | 17 | 180 | 45.6 | ||||
3323-04180 | 17+ | 190 | 46.3 | ||||
BE2 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
/ | 6 | 110 | 32 | 127 & 133 Versi Dua | Ti6al4v | Ti+ha | |
7 | 115 | 33 | |||||
8 | 120 | 34 | |||||
9 | 125 | 35 | |||||
10 | 130 | 36 | |||||
11 | 135 | 37 | |||||
12 | 140 | 38 | |||||
13 | 145 | 39 | |||||
14 | 150 | 40 | |||||
15 | 155 | 41 | |||||
16 | 160 | 42 | |||||
17 | 165 | 43 | |||||
18 | 170 | 44 | |||||
155 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | Foto. |
3332-02070 | 7 | 120 | 32.3 | 132 | Ti6al4v | ![]() | ![]() |
3332-02080 | 8 | 125 | 33.3 | ||||
3332-02090 | 9 | 130 | 34.3 | ||||
3332-02100 | 10 | 135 | 35.4 | ||||
3332-02110 | 11 | 140 | 36.4 | ||||
3332-02120 | 12 | 145 | 37.6 | ||||
3332-02130 | 13 | 150 | 38.8 | ||||
3332-02140 | 14 | 155 | 39.9 | ||||
3332-02150 | 15 | 160 | 41.1 | ||||
3332-02160 | 16 | 165 | 42.3 | ||||
3332-02170 | 16+ | 170 | 43.5 | ||||
3332-02180 | 16 ++ | 175 | 44.7 |
130 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3320-02060 | 6 | 100 | 32 | 125 | Ti6al4v | Ti | |
3320-02070 | 7 | 100 | 33 | ||||
3320-02080 | 8 | 110 | 34 | ||||
3320-02090 | 9 | 110 | 35 | ||||
3320-02100 | 10 | 120 | 36 | ||||
3320-02110 | 11 | 120 | 37.5 | ||||
3320-02120 | 12 | 130 | 39 | ||||
130 batang panjang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | ![]() ![]() |
3315-01100 | 10 | 185 & 205 & 220 & 250 | 40 | 135 | Ti6al4v | Ti | |
3315-01110 | 11 | 40 | |||||
3315-01120 | 12 | 41 | |||||
3315-01130 | 13 | 41 | |||||
3315-01140 | 14 | 42 | |||||
3315-01150 | 15 | 42 | |||||
3315-01160 | 16 | 42 | |||||
BE1 STEM | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Angl Neck | Tikar. | Lapisan | Foto. |
3331-02060 | 6 | 112 | 40.4 | 132 | Ti6al4v | Ti | ![]() ![]() |
3331-02070 | 7 | 114 | 40.9 | ||||
3331-02080 | 8 | 116 | 41.4 | ||||
3331-02090 | 9 | 120 | 41.9 | ||||
3331-02100 | 10 | 122 | 42.4 | ||||
3331-02110 | 11 | 124 | 43.9 | ||||
3331-02120 | 12 | 126 | 46.9 | ||||
3331-02130 | 13 | 128 | 47.9 | ||||
3331-02140 | 13+ | 130 | 48.4 | ||||
160 batang | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | ![]() | Foto. |
3325-02090 | 9 | 150 | 39 | 130 | Ti6al4v | Ti | ![]() |
3325-02100 | 10 | 39.5 | |||||
3325-02110 | 11 | 40 | |||||
3325-02120 | 12 | 40.5 | |||||
3325-02130 | 13 | 41 | |||||
3325-01240 | 14 | 41.5 | |||||
3325-02150 | 15 | 41.5 | |||||
3325-02160 | 16 | 42 | |||||
3325-02180 | 18 | ||||||
3325-02200 | 20 | 42.5 | |||||
160 batang (200mm panjang, untuk revisi atau fraktur trokanteri) | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | Lapisan | Foto. |
3326-02091 | 9L | 200 | 39 | 130 | Ti6al4v | ![]() | ![]() |
3326-02092 | 9r | ||||||
3326-02101 | 10L | 39.5 | |||||
3326-02102 | 10r | ||||||
3326-02111 | 11L | 40 | |||||
3326-02112 | 11r | ||||||
3326-02121 | 12L | 40.5 | |||||
3326-02122 | 12r | ||||||
3326-02131 | 13L | 41 | |||||
3326-02132 | 13r | ||||||
3326-02141 | 14L | 41.5 | |||||
3326-02142 | 14r | ||||||
3326-02161 | 16L | 42 | |||||
3326-02162 | 16r | ||||||
3326-02181 | 18L | 42.5 | |||||
3326-02182 | 18r | ||||||
3326-02201 | 20L | 43 | |||||
3326-02202 | 20r | ||||||
160 batang (250mm panjang, untuk revisi atau fraktur trokanteri) | |||||||
Kode | Ukuran | Panjang batang | Mengimbangi | Sudut leher | Tikar. | ![]() | ![]() |
3327-02101 | 10L | 250 | 39.5 | 130 | Ti6al4v | Ti | |
3327-02102 | 10r | ||||||
3327-02121 | 12L | 40.5 | |||||
3327-02122 | 12r | ||||||
3327-02141 | 14L | 41.5 | |||||
3327-02142 | 14r | ||||||
3327-02161 | 16L | 42 | |||||
3327-02162 | 16r | ||||||
3327-02181 | 18L | 42.5 | |||||
3327-02182 | 18r | ||||||
3327-02201 | 20L | 43 | |||||
3327-02202 | 20r |
Pemrosesan pendahuluan CNC Teknologi kontrol numerik komputer digunakan untuk memproses produk ortopedi secara tepat. Proses ini memiliki karakteristik presisi tinggi, efisiensi tinggi, dan pengulangan. Ini dapat dengan cepat menghasilkan perangkat medis khusus yang sesuai dengan struktur anatomi manusia dan memberikan pasien dengan rencana perawatan yang dipersonalisasi. | Pemolesan produk Tujuan pemolesan produk ortopedi adalah untuk meningkatkan kontak antara implan dan jaringan manusia, mengurangi konsentrasi stres, dan meningkatkan stabilitas jangka panjang implan. | Inspeksi Kualitas Uji sifat mekanik produk ortopedi dirancang untuk mensimulasikan kondisi stres tulang manusia, mengevaluasi kapasitas penahan beban dan daya tahan implan dalam tubuh manusia, dan memastikan keamanan dan keandalannya. |
Paket produk Produk ortopedi dikemas di ruang steril untuk memastikan bahwa produk dienkapsulasi dalam lingkungan yang bersih dan steril untuk mencegah kontaminasi mikroba dan memastikan keamanan bedah. |
Penyimpanan produk ortopedi membutuhkan manajemen masuk-dan-keluar yang ketat dan kontrol kualitas untuk memastikan keterlacakan produk dan mencegah kedaluwarsa atau pengiriman yang salah. |
Ruang sampel digunakan untuk menyimpan, menampilkan, dan mengelola berbagai sampel produk ortopedi untuk pertukaran dan pelatihan teknologi produk. |
1. Mintalah tim XC Medico untuk katalog produk HIP revisi tanpa semen.
2. Pilih produk Hip Revision Tanpa Semen yang Anda minati.
3. Mintalah sampel untuk menguji pinggul revisi tanpa semen.
4. Buat pesanan Hip Revisi Tanpa Semen XC Medico.
5. Berdasarkan dealer Hip Revisi Tanpa Semen XC Medico.
1. Harga pembelian lebih baik dari Hip Revisi Tanpa Semen.
2,100% Pinggul revisi tanpa semen berkualitas tinggi.
3. Upaya pemesanan yang lebih sedikit.
4. Stabilitas harga untuk periode perjanjian.
5. Pinggul revisi tanpa semen yang cukup.
6. Penilaian Cepat dan Mudah dari Hip Revisi Tanpa Semen XC Medico.
7. Merek yang diakui secara global - XC Medico.
8. Waktu akses cepat ke tim penjualan XC Medico.
9. Tes kualitas tambahan oleh tim XC Medico.
10. Lacak pesanan XC Medico Anda dari awal hingga akhir.
Implan pinggul revisi tanpa semen merupakan kemajuan vital di bidang bedah ortopedi, terutama dalam mengatasi komplikasi yang terkait dengan penggantian pinggul yang gagal atau usang. Implan ini dirancang untuk meningkatkan mobilitas, mengurangi rasa sakit, dan memulihkan fungsionalitas tanpa menggunakan semen tulang. Panduan ini memberikan gambaran mendalam tentang pinggul revisi tanpa semen, mengeksplorasi fitur, keunggulan, aplikasi, dan potensi pasar di masa depan, melayani para profesional ortopedi dan penggemar medis.
Hip revisi tanpa semen mengacu pada jenis implan pinggul yang dirancang untuk digunakan dalam operasi revisi, di mana implan pinggul yang ditempatkan sebelumnya telah gagal, melonggarkan, atau menyebabkan komplikasi. Tidak seperti implan tradisional yang mengandalkan semen tulang untuk fiksasi, implan tanpa semen mencapai stabilitas melalui fiksasi biologis. Ini difasilitasi oleh permukaan berpori mereka, yang mempromosikan pertumbuhan tulang langsung ke implan, menciptakan ikatan yang tahan lama dan stabil.
Implan ini sangat cocok untuk pasien dengan kualitas tulang yang baik dan mereka yang menjalani prosedur di mana konservasi tulang sangat penting. Desain tanpa semen semakin disukai kemampuannya untuk berintegrasi dengan struktur tulang alami dan mengurangi risiko komplikasi yang terkait dengan implan semen.
Lapisan berpori, sering terbuat dari titanium atau hidroksiapatit, mendorong osseointegrasi, memungkinkan tulang alami tumbuh menjadi implan.
Banyak implan memiliki desain batang yang meruncing untuk mencapai kesesuaian yang aman di kanal femoralis, meningkatkan stabilitas awal.
Desain modular memungkinkan kustomisasi yang lebih besar, memungkinkan ahli bedah untuk menyesuaikan implan dengan anatomi unik dan struktur tulang pasien.
Bahan berkekuatan tinggi seperti paduan titanium biasanya digunakan untuk biokompatibilitasnya yang sangat baik, sifat ringan, dan resistensi korosi.
Desain anatomi meniru kontur alami femur dan acetabulum, meningkatkan stabilitas implan dan kenyamanan pasien.
Sistem tanpa semen sering kali mencakup opsi untuk batang panjang panjang dan ugments asetabular untuk kasus kehilangan tulang yang parah.
Fiksasi biologis memastikan bahwa implan tetap melekat pada tulang dari waktu ke waktu, mengurangi kemungkinan pelonggaran atau kegagalan.
Dengan menghilangkan penggunaan semen tulang, yang dapat berfungsi sebagai situs potensial untuk pertumbuhan bakteri, risiko infeksi pasca operasi diminimalkan.
Desain tanpa semen memungkinkan konservasi tulang, yang sangat bermanfaat pada pasien yang lebih muda yang mungkin memerlukan revisi lebih lanjut di masa depan.
Pertumbuhan tulang alami ke dalam implan meningkatkan distribusi beban dan meminimalkan pelindung tegangan, yang mengarah ke hasil jangka panjang yang lebih baik.
Ahli bedah dapat menyesuaikan implan untuk mengatasi tantangan spesifik, seperti keropos tulang atau kelainan bentuk, meningkatkan hasil bedah.
Pasien sering mengalami waktu pemulihan yang lebih cepat dan meningkatkan mobilitas pasca operasi karena fiksasi alami yang aman yang disediakan oleh implan ini.
Ketika implan pinggul yang ditempatkan sebelumnya kehilangan keterikatannya pada tulang tanpa infeksi, implan tanpa semen menawarkan penggantian yang stabil.
Dalam kasus fraktur di sekitar implan asli, desain tanpa semen dapat mengakomodasi dan menstabilkan kondisi kompleks ini.
Kehilangan tulang yang disebabkan oleh puing -puing keausan dari implan sebelumnya dapat dikurangi dengan penggunaan implan tanpa semen yang mempromosikan regenerasi tulang.
Untuk pasien dengan dislokasi berulang atau sendi pinggul yang tidak stabil, implan revisi tanpa semen mengembalikan keselarasan dan stabilitas yang tepat.
Setelah penghapusan implan terkait infeksi dan pemberantasan infeksi, desain tanpa semen memberikan opsi yang andal untuk implantasi ulang.
Dalam beberapa kasus, tulang alami mungkin membutuhkan waktu lebih lama untuk tumbuh menjadi implan, yang menyebabkan ketidakstabilan sementara.
Pasien dengan kualitas tulang yang buruk, seperti mereka yang memiliki osteoporosis parah, mungkin tidak mencapai fiksasi yang memadai, meningkatkan risiko kegagalan implan.
Prosedur revisi tanpa semen dapat lebih menuntut secara teknis, membutuhkan ahli bedah berpengalaman dan peralatan khusus.
Teknik implantasi yang tidak tepat dapat menyebabkan patah tulang paha atau acetabulum.
Seiring waktu, komponen implan dapat dipakai, memerlukan revisi lebih lanjut.
Implan tanpa semen seringkali lebih mahal daripada pilihan semen, yang dapat membatasi aksesibilitas untuk beberapa pasien.
Seiring bertambahnya usia populasi global, permintaan untuk operasi revisi pinggul diperkirakan akan meningkat, meningkatkan kebutuhan implan yang andal.
Inovasi dalam bahan biokompatibel, seperti pelapis bioaktif dan implan cetak 3D, meningkatkan kinerja sistem tanpa semen.
Preferensi yang berkembang untuk fiksasi biologis di antara ahli bedah memastikan adopsi implan tanpa semen yang berkelanjutan.
Memperluas infrastruktur perawatan kesehatan di daerah seperti Asia-Pasifik dan Amerika Latin menghadirkan peluang yang belum dimanfaatkan untuk pertumbuhan pasar.
Integrasi operasi yang dibantu robot dan alat perencanaan yang digerakkan AI meningkatkan ketepatan prosedur implan tanpa semen.
Pinggul revisi tanpa semen adalah landasan operasi ortopedi modern, menawarkan solusi yang efektif, tahan lama, dan biokompatibel untuk kasus revisi pinggul. Desain inovatifnya mempromosikan integrasi tulang alami, mengurangi risiko yang terkait dengan implan tradisional semen. Sementara tantangan bedah dan faktor spesifik pasien harus dipertimbangkan dengan cermat, keunggulan sistem tanpa semen menjadikannya pilihan yang lebih disukai bagi banyak ahli bedah ortopedi.
Ketika teknologi terus maju dan permintaan global untuk operasi revisi tumbuh, pinggul revisi tanpa semen akan memainkan peran yang semakin vital dalam meningkatkan hasil pasien dan mendefinisikan kembali standar dalam operasi penggantian pinggul.
Pengingat Hangat: Artikel ini hanya untuk referensi dan tidak dapat menggantikan saran profesional dokter. Jika Anda memiliki pertanyaan, silakan berkonsultasi dengan dokter yang hadir.
Konten kosong!
Kontak