J005
Xcmedico
1 računalniki (72 ur dostava)
Titanova zlitina
CE/ISO: 9001/ISO13485.ETC
15-dnevna dostava po meri (brez časa pošiljanja)
Fedex. Dhl.tnt.ems.etc
Razpoložljivost: | |
---|---|
Količina: | |
BB steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3311-04090 | 9 | 135 | 33.8 | 135 | Ti6al4v | Ti+ha | |
3311-04100 | 10 | 140 | 34.5 | ||||
3311-04110 | 11 | 145 | 35.2 | ||||
3311-04120 | 12 | 150 | 36 | ||||
3311-04130 | 13 | 155 | 36.8 | ||||
3311-04140 | 14 | 155 | 37.6 | ||||
3311-04150 | 15 | 155 | 38.4 | ||||
3311-04160 | 16 | 160 | 39.2 | ||||
3311-04170 | 17 | 160 | 40.2 | ||||
3311-04180 | 18 | 165 | 41.2 | ||||
145 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3330-01070 | 7 | 130 | 30.4 | 135 | Ti6al4v | strel | |
3330-01080 | 8 | 135 | 31.7 | ||||
3330-01090 | 9 | 140 | 33 | ||||
3330-01100 | 10 | 145 | 34.3 | ||||
3330-01110 | 11 | 150 | 35.6 | ||||
3330-01120 | 12 | 155 | 36.9 | ||||
3330-01130 | 13 | 160 | 38.2 | ||||
3330-01140 | 14 | 165 | 39.5 | ||||
140 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
20 | 9 | 140 | 37.5 | 130 | Ti6al4v | Ti | |
3310-02100 | 10 | 145 | 38 | ||||
3310-02110 | 11 | 150 | 38.5 | ||||
3310-02120 | 12 | 155 | 39 | ||||
3310-02130 | 13 | 160 | 40 | ||||
3310-02140 | 14 | 165 | 41 | ||||
3310-02150 | 15 | 170 | 42 | ||||
Biti steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3323-04080 | 8 | 115 | 38.4 | 135 | Ti6al4v | Ti+ha | |
3323-04090 | 9 | 130 | 38.9 | ||||
3323-04100 | 10 | 140 | 39.8 | ||||
3323-04110 | 11 | 145 | 40.7 | ||||
3323-04120 | 12 | 150 | 41.3 | ||||
3323-04130 | 13 | 155 | 42.2 | ||||
3323-04140 | 14 | 160 | 43.1 | ||||
3323-04150 | 15 | 165 | 44 | ||||
3323-04160 | 16 | 170 | 44.8 | ||||
3323-04170 | 17 | 180 | 45.6 | ||||
3323-04180 | 17+ | 190 | 46.3 | ||||
Be2 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
/ | 6 | 110 | 32 | 127 in 133 dve različici | Ti6al4v | Ti+ha | |
7 | 115 | 33 | |||||
8 | 120 | 34 | |||||
9 | 125 | 35 | |||||
10 | 130 | 36 | |||||
11 | 135 | 37 | |||||
12 | 140 | 38 | |||||
13 | 145 | 39 | |||||
14 | 150 | 40 | |||||
15 | 155 | 41 | |||||
16 | 160 | 42 | |||||
17 | 165 | 43 | |||||
18 | 170 | 44 | |||||
155 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | Slika. |
3332-02070 | 7 | 120 | 32.3 | 132 | Ti6al4v | ![]() | ![]() |
3332-02080 | 8 | 125 | 33.3 | ||||
3332-02090 | 9 | 130 | 34.3 | ||||
3332-02100 | 10 | 135 | 35.4 | ||||
3332-02110 | 11 | 140 | 36.4 | ||||
3332-02120 | 12 | 145 | 37.6 | ||||
3332-02130 | 13 | 150 | 38.8 | ||||
3332-02140 | 14 | 155 | 39.9 | ||||
3332-02150 | 15 | 160 | 41.1 | ||||
3332-02160 | 16 | 165 | 42.3 | ||||
3332-02170 | 16+ | 170 | 43.5 | ||||
3332-02180 | 16 ++ | 175 | 44.7 |
130 stebla | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3320-02060 | 6 | 100 | 32 | 125 | Ti6al4v | Ti | |
3320-02070 | 7 | 100 | 33 | ||||
3320-02080 | 8 | 110 | 34 | ||||
3320-02090 | 9 | 110 | 35 | ||||
3320-02100 | 10 | 120 | 36 | ||||
3320-02110 | 11 | 120 | 37.5 | ||||
3320-02120 | 12 | 130 | 39 | ||||
130 dolge stebla | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3315-01100 | 10 | 185 & 205 & 220 & 250 | 40 | 135 | Ti6al4v | Ti | |
3315-01110 | 11 | 40 | |||||
3315-01120 | 12 | 41 | |||||
3315-01130 | 13 | 41 | |||||
3315-01140 | 14 | 42 | |||||
3315-01150 | 15 | 42 | |||||
3315-01160 | 16 | 42 | |||||
Be1 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Vrat Anggl | Podstavek. | Prevleka | Slika. |
3331-02060 | 6 | 112 | 40.4 | 132 | Ti6al4v | Ti | ![]() ![]() |
3331-02070 | 7 | 114 | 40.9 | ||||
3331-02080 | 8 | 116 | 41.4 | ||||
3331-02090 | 9 | 120 | 41.9 | ||||
3331-02100 | 10 | 122 | 42.4 | ||||
3331-02110 | 11 | 124 | 43.9 | ||||
3331-02120 | 12 | 126 | 46.9 | ||||
3331-02130 | 13 | 128 | 47.9 | ||||
3331-02140 | 13+ | 130 | 48.4 | ||||
160 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | ![]() | Slika. |
3325-02090 | 9 | 150 | 39 | 130 | Ti6al4v | Ti | ![]() |
3325-02100 | 10 | 39.5 | |||||
3325-02110 | 11 | 40 | |||||
3325-02120 | 12 | 40.5 | |||||
3325-02130 | 13 | 41 | |||||
3325-01240 | 14 | 41.5 | |||||
3325-02150 | 15 | 41.5 | |||||
3325-02160 | 16 | 42 | |||||
3325-02180 | 18 | ||||||
3325-02200 | 20 | 42.5 | |||||
160 steblo ((200 mm dolga, za revizijo ali trohanterično zlom) | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | Slika. |
3326-02091 | 9L | 200 | 39 | 130 | Ti6al4v | ![]() | ![]() |
3326-02092 | 9r | ||||||
3326-02101 | 10L | 39.5 | |||||
3326-02102 | 10R | ||||||
3326-02111 | 11L | 40 | |||||
3326-02112 | 11r | ||||||
3326-02121 | 12L | 40.5 | |||||
3326-02122 | 12r | ||||||
3326-02131 | 13L | 41 | |||||
3326-02132 | 13R | ||||||
3326-02141 | 14L | 41.5 | |||||
3326-02142 | 14r | ||||||
3326-02161 | 16L | 42 | |||||
3326-02162 | 16r | ||||||
3326-02181 | 18L | 42.5 | |||||
3326-02182 | 18r | ||||||
3326-02201 | 20L | 43 | |||||
3326-02202 | 20r | ||||||
160 steblo ((250 mm dolga, za revizijo ali trohanterično zlom | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | ![]() | ![]() |
3327-02101 | 10L | 250 | 39.5 | 130 | Ti6al4v | Ti | |
3327-02102 | 10R | ||||||
3327-02121 | 12L | 40.5 | |||||
3327-02122 | 12r | ||||||
3327-02141 | 14L | 41.5 | |||||
3327-02142 | 14r | ||||||
3327-02161 | 16L | 42 | |||||
3327-02162 | 16r | ||||||
3327-02181 | 18L | 42.5 | |||||
3327-02182 | 18r | ||||||
3327-02201 | 20L | 43 | |||||
3327-02202 | 20r |
CNC predhodna obdelava Tehnologija računalniškega numeričnega krmiljenja se uporablja za natančno obdelavo ortopedskih izdelkov. Ta postopek ima značilnosti visoke natančnosti, visoke učinkovitosti in ponovljivosti. Hitro lahko ustvari prilagojene medicinske pripomočke, ki ustrezajo človeški anatomski strukturi in bolnikom zagotavljajo prilagojene načrte zdravljenja. | Poliranje izdelkov Namen poliranja ortopedskih izdelkov je izboljšati stik med vsadkom in človeškim tkivom, zmanjšati koncentracijo stresa in izboljšati dolgoročno stabilnost vsadka. | Pregled kakovosti Test mehanskih lastnosti ortopedskih izdelkov je zasnovan tako, da simulira stresne razmere človeških kosti, oceni zmogljivosti in trajnost vsadkov v človeškem telesu in zagotavlja njihovo varnost in zanesljivost. |
Paket izdelkov Ortopedski izdelki so pakirani v sterilni sobi, da se zagotovi, da je izdelek zaprt v čisto, sterilno okolje, da se prepreči mikrobna kontaminacija in zagotovi kirurško varnost. |
Skladiščenje ortopedskih izdelkov zahteva strogo upravljanje in nadzor nad kakovostjo in nadzor kakovosti, da se zagotovi sledljivost izdelkov in prepreči iztekanje ali napačno pošiljko. |
Vzorčna soba se uporablja za shranjevanje, prikazovanje in upravljanje različnih vzorcev ortopedskih izdelkov za izmenjave tehnologije izdelkov in usposabljanje. |
1. Vprašajte XC Medico Ekipa za katalog izdelkov brez cementne revizije.
2. Izberite svoj zainteresiran izdelek brez cementne revizije HIP.
3. Prosite za vzorec za testiranje revizijskega kolka brez cemenlja.
4. Vzemite vrstni red revizijskega kolka XC Medico.
5.ED Trgovina XC Medicovega revizijskega kolka.
1.Better Nakupne cene revizijskega kolka brez cemenlja.
2,100% najvišje kakovostni revizijski kolk.
3. Manj prizadevanja za naročanje.
4. stabilnost cen za obdobje dogovora.
5. Zadostno revizijsko revizijsko kolko.
6. Hitra in enostavna ocena revizijskega kolka XC Medico.
7. Globalno priznana blagovna znamka - XC Medico.
8. Čas hitrega dostopa do prodajne ekipe XC Medico.
9. Dodatni preizkus kakovosti s strani XC Medicove ekipe.
10. Sledite svojemu naročilo XC Medica od začetka do konca.
Implantat za kolke brez cementiranja predstavlja življenjsko napredovanje na področju ortopedske kirurgije, zlasti pri reševanju zapletov, povezanih z neuspeli ali dotrajani zamenjavi kolka. Ti vsadki so zasnovani za izboljšanje mobilnosti, zmanjšanje bolečine in obnavljanje funkcionalnosti brez uporabe kostnih cementa. Ta priročnik ponuja poglobljen pregled revizijskih bokov brez cemenlja, raziskuje njihove značilnosti, prednosti, aplikacije in prihodnji tržni potencial, ki skrbi za ortopedske strokovnjake in medicinske navdušence.
HIP brez cementnega revizije se nanaša na vrsto vsadka kolka, zasnovan za uporabo v revizijskih operacijah, kjer je predhodno nameščen hip implantat ni uspel, zrahljal ali povzročil zaplete. Za razliko od tradicionalnih vsadkov, ki se za fiksacijo zanašajo na kostni cement, brez cementnih vsadkov z biološko fiksacijo dosežejo stabilnost. To olajša njihova porozna površina, ki spodbuja rast kosti neposredno v implantat, kar ustvarja dolgotrajno in stabilno vez.
Ti vsadki so še posebej primerni za bolnike z dobro kakovostjo kosti in tiste, ki so podvrženi postopkom, kjer je ohranjanje kosti ključnega pomena. Modeli brez cementa so vedno bolj naklonjeni njihovi sposobnosti integracije z naravno strukturo kosti in zmanjšanje tveganja za zaplete, povezane s cementiranimi vsadki.
Porozna prevleka, ki je pogosto narejena iz titana ali hidroksiapatita, spodbuja osseintegracijo, kar omogoča naravno kost v vsadek.
Številni vsadki odlikujejo konično zasnovo stebel, da se doseže varno prileganje v stegnenični kanal, kar izboljšuje začetno stabilnost.
Modularni modeli omogočajo večjo prilagajanje, kar kirurgom omogoča, da prilagodijo implantat bolnikovi edinstveni anatomiji in kostni strukturi.
Visoke trdne materiale, kot so titanove zlitine, se običajno uporabljajo za svojo odlično biokompatibilnost, lahka narava in korozijsko odpornost.
Anatomske zasnove posnemajo naravne obrise stegnenice in acetabuluma, kar povečuje stabilnost vsadka in udobje pacienta.
Sistemi brez cementa pogosto vključujejo možnosti za stebla z podaljšano dolžino in acetabularna povečanja za hude primere izgube kosti.
Biološka fiksacija zagotavlja, da implantat ostane varno pritrjen na kost sčasoma, kar zmanjšuje verjetnost popuščanja ali okvare.
Z odpravo uporabe kostnih cementa, ki lahko služi kot potencialno mesto za rast bakterij, se zmanjša tveganje za pooperativno okužbo.
Modeli brez cementa omogočajo ohranjanje kosti, kar je še posebej koristno pri mlajših bolnikih, ki bodo v prihodnosti morda potrebovali nadaljnje revizije.
Naravna rast kosti v implantat povečuje porazdelitev obremenitve in zmanjšuje zaščito pred stresom, kar vodi do boljših dolgoročnih rezultatov.
Kirurgi lahko implantat prilagodijo posebnim izzivom, kot so izguba kosti ali deformacije, kar izboljšuje kirurške rezultate.
Bolniki pogosto doživljajo hitrejše čase okrevanja in izboljšajo pooperativno mobilnost zaradi varne, naravne fiksacije, ki jo zagotavljajo ti vsadki.
Ko predhodno nameščen kolčni vsadek izgubi pritrditev na kost brez okužbe, implantat brez cementa ponuja stabilno zamenjavo.
V primerih zlomov okoli originalnega implantata lahko konstrukcija brez cemenlja sprejme in stabilizira te zapletene pogoje.
Izguba kosti, ki jo povzročajo obrabe iz prejšnjih vsadkov, je mogoče ublažiti z uporabo vsadkov brez cementa, ki spodbujajo regeneracijo kosti.
Za bolnike s ponavljajočimi se dislokacijami ali nestabilnimi kolčnimi sklepi, brez cementni revizijski vsadki obnovijo pravilno poravnavo in stabilnost.
Po odstranitvi vsadkov in izkoreninjenja okužbe z okužbo in izkoreninjenja okužbe nudijo zanesljivo možnost ponovne implantacije zanesljiva možnost.
V nekaterih primerih lahko naravna kost traja dlje časa, da zraste v implantat, kar vodi do začasne nestabilnosti.
Bolniki s slabo kakovostjo kosti, kot so tisti s hudo osteoporozo, morda ne bodo dosegli ustrezne fiksacije, kar bi povečalo tveganje za odpoved vsadka.
Postopki revizije brez cementov so lahko tehnično zahtevnejši, kar zahteva izkušene kirurge in specializirano opremo.
Nepravilne tehnike implantacije lahko privedejo do zlomov stegnenice ali acetabuluma.
Sčasoma lahko komponente implantata nosijo, kar zahteva nadaljnje revizije.
Cementni vsadki so pogosto dražji od cementiranih možnosti, kar lahko za nekatere bolnike omeji dostopnost.
Ker se svetovno prebivalstvo stara, se pričakuje, da se bo povpraševanje po operacijah revizije kolka povečalo, kar bo povečalo potrebo po zanesljivih vsadkih.
Inovacije v biokompatibilnih materialih, kot so bioaktivni premazi in 3D-natisnjeni vsadki, izboljšujejo delovanje sistemov brez cementov.
Naraščajoča prednost biološke fiksacije med kirurgi zagotavlja trajno sprejemanje cementnih vsadkov.
Razširitev zdravstvene infrastrukture v regijah, kot sta Azijsko-Pacifik in Latinska Amerika, ponuja neizkoriščene priložnosti za rast trga.
Vključitev robotskih operacij in orodij za načrtovanje AI-Gend Forming Forming natančnost postopkov brez cementnih implantatov.
HIP brez cemenlja je temelj sodobne ortopedske kirurgije, ki ponuja učinkovito, trajno in biokompatibilno rešitev za primere revizije kolka. Njegova inovativna zasnova spodbuja naravno integracijo kosti in zmanjšuje tveganja, povezana s tradicionalnimi cementiranimi vsadki. Medtem ko je treba skrbno upoštevati kirurške izzive in dejavnike, specifične za bolnika, jih prednosti brez cementnih sistemov postanejo prednostna izbira za številne ortopedske kirurge.
Ker tehnologija še naprej napreduje in povečuje globalno povpraševanje po revizijskih operacijah, bo brezžični revizijski kolk postavljen tako, da bo imel vse pomembnejšo vlogo pri izboljšanju rezultatov pacientov in na novo opredeljevanju standardov pri operaciji nadomestitve kolka.
Topel opomnik: Ta članek je samo za referenco in ne more nadomestiti zdravnikovega strokovnega nasveta. Če imate kakršna koli vprašanja, se posvetujte s svojim zdravnikom.
BB steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3311-04090 | 9 | 135 | 33.8 | 135 | Ti6al4v | Ti+ha | |
3311-04100 | 10 | 140 | 34.5 | ||||
3311-04110 | 11 | 145 | 35.2 | ||||
3311-04120 | 12 | 150 | 36 | ||||
3311-04130 | 13 | 155 | 36.8 | ||||
3311-04140 | 14 | 155 | 37.6 | ||||
3311-04150 | 15 | 155 | 38.4 | ||||
3311-04160 | 16 | 160 | 39.2 | ||||
3311-04170 | 17 | 160 | 40.2 | ||||
3311-04180 | 18 | 165 | 41.2 | ||||
145 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3330-01070 | 7 | 130 | 30.4 | 135 | Ti6al4v | strel | |
3330-01080 | 8 | 135 | 31.7 | ||||
3330-01090 | 9 | 140 | 33 | ||||
3330-01100 | 10 | 145 | 34.3 | ||||
3330-01110 | 11 | 150 | 35.6 | ||||
3330-01120 | 12 | 155 | 36.9 | ||||
3330-01130 | 13 | 160 | 38.2 | ||||
3330-01140 | 14 | 165 | 39.5 | ||||
140 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
20 | 9 | 140 | 37.5 | 130 | Ti6al4v | Ti | |
3310-02100 | 10 | 145 | 38 | ||||
3310-02110 | 11 | 150 | 38.5 | ||||
3310-02120 | 12 | 155 | 39 | ||||
3310-02130 | 13 | 160 | 40 | ||||
3310-02140 | 14 | 165 | 41 | ||||
3310-02150 | 15 | 170 | 42 | ||||
Biti steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3323-04080 | 8 | 115 | 38.4 | 135 | Ti6al4v | Ti+ha | |
3323-04090 | 9 | 130 | 38.9 | ||||
3323-04100 | 10 | 140 | 39.8 | ||||
3323-04110 | 11 | 145 | 40.7 | ||||
3323-04120 | 12 | 150 | 41.3 | ||||
3323-04130 | 13 | 155 | 42.2 | ||||
3323-04140 | 14 | 160 | 43.1 | ||||
3323-04150 | 15 | 165 | 44 | ||||
3323-04160 | 16 | 170 | 44.8 | ||||
3323-04170 | 17 | 180 | 45.6 | ||||
3323-04180 | 17+ | 190 | 46.3 | ||||
Be2 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
/ | 6 | 110 | 32 | 127 in 133 dve različici | Ti6al4v | Ti+ha | |
7 | 115 | 33 | |||||
8 | 120 | 34 | |||||
9 | 125 | 35 | |||||
10 | 130 | 36 | |||||
11 | 135 | 37 | |||||
12 | 140 | 38 | |||||
13 | 145 | 39 | |||||
14 | 150 | 40 | |||||
15 | 155 | 41 | |||||
16 | 160 | 42 | |||||
17 | 165 | 43 | |||||
18 | 170 | 44 | |||||
155 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | Slika. |
3332-02070 | 7 | 120 | 32.3 | 132 | Ti6al4v | ![]() | ![]() |
3332-02080 | 8 | 125 | 33.3 | ||||
3332-02090 | 9 | 130 | 34.3 | ||||
3332-02100 | 10 | 135 | 35.4 | ||||
3332-02110 | 11 | 140 | 36.4 | ||||
3332-02120 | 12 | 145 | 37.6 | ||||
3332-02130 | 13 | 150 | 38.8 | ||||
3332-02140 | 14 | 155 | 39.9 | ||||
3332-02150 | 15 | 160 | 41.1 | ||||
3332-02160 | 16 | 165 | 42.3 | ||||
3332-02170 | 16+ | 170 | 43.5 | ||||
3332-02180 | 16 ++ | 175 | 44.7 |
130 stebla | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3320-02060 | 6 | 100 | 32 | 125 | Ti6al4v | Ti | |
3320-02070 | 7 | 100 | 33 | ||||
3320-02080 | 8 | 110 | 34 | ||||
3320-02090 | 9 | 110 | 35 | ||||
3320-02100 | 10 | 120 | 36 | ||||
3320-02110 | 11 | 120 | 37.5 | ||||
3320-02120 | 12 | 130 | 39 | ||||
130 dolge stebla | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | ![]() ![]() |
3315-01100 | 10 | 185 & 205 & 220 & 250 | 40 | 135 | Ti6al4v | Ti | |
3315-01110 | 11 | 40 | |||||
3315-01120 | 12 | 41 | |||||
3315-01130 | 13 | 41 | |||||
3315-01140 | 14 | 42 | |||||
3315-01150 | 15 | 42 | |||||
3315-01160 | 16 | 42 | |||||
Be1 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Vrat Anggl | Podstavek. | Prevleka | Slika. |
3331-02060 | 6 | 112 | 40.4 | 132 | Ti6al4v | Ti | ![]() ![]() |
3331-02070 | 7 | 114 | 40.9 | ||||
3331-02080 | 8 | 116 | 41.4 | ||||
3331-02090 | 9 | 120 | 41.9 | ||||
3331-02100 | 10 | 122 | 42.4 | ||||
3331-02110 | 11 | 124 | 43.9 | ||||
3331-02120 | 12 | 126 | 46.9 | ||||
3331-02130 | 13 | 128 | 47.9 | ||||
3331-02140 | 13+ | 130 | 48.4 | ||||
160 steblo | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | ![]() | Slika. |
3325-02090 | 9 | 150 | 39 | 130 | Ti6al4v | Ti | ![]() |
3325-02100 | 10 | 39.5 | |||||
3325-02110 | 11 | 40 | |||||
3325-02120 | 12 | 40.5 | |||||
3325-02130 | 13 | 41 | |||||
3325-01240 | 14 | 41.5 | |||||
3325-02150 | 15 | 41.5 | |||||
3325-02160 | 16 | 42 | |||||
3325-02180 | 18 | ||||||
3325-02200 | 20 | 42.5 | |||||
160 steblo ((200 mm dolga, za revizijo ali trohanterično zlom) | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | Prevleka | Slika. |
3326-02091 | 9L | 200 | 39 | 130 | Ti6al4v | ![]() | ![]() |
3326-02092 | 9r | ||||||
3326-02101 | 10L | 39.5 | |||||
3326-02102 | 10R | ||||||
3326-02111 | 11L | 40 | |||||
3326-02112 | 11r | ||||||
3326-02121 | 12L | 40.5 | |||||
3326-02122 | 12r | ||||||
3326-02131 | 13L | 41 | |||||
3326-02132 | 13R | ||||||
3326-02141 | 14L | 41.5 | |||||
3326-02142 | 14r | ||||||
3326-02161 | 16L | 42 | |||||
3326-02162 | 16r | ||||||
3326-02181 | 18L | 42.5 | |||||
3326-02182 | 18r | ||||||
3326-02201 | 20L | 43 | |||||
3326-02202 | 20r | ||||||
160 steblo ((250 mm dolga, za revizijo ali trohanterično zlom | |||||||
Koda | Velikost | Dolžina stebla | Odmik | Kot vratu | Podstavek. | ![]() | ![]() |
3327-02101 | 10L | 250 | 39.5 | 130 | Ti6al4v | Ti | |
3327-02102 | 10R | ||||||
3327-02121 | 12L | 40.5 | |||||
3327-02122 | 12r | ||||||
3327-02141 | 14L | 41.5 | |||||
3327-02142 | 14r | ||||||
3327-02161 | 16L | 42 | |||||
3327-02162 | 16r | ||||||
3327-02181 | 18L | 42.5 | |||||
3327-02182 | 18r | ||||||
3327-02201 | 20L | 43 | |||||
3327-02202 | 20r |
CNC predhodna obdelava Tehnologija računalniškega numeričnega krmiljenja se uporablja za natančno obdelavo ortopedskih izdelkov. Ta postopek ima značilnosti visoke natančnosti, visoke učinkovitosti in ponovljivosti. Hitro lahko ustvari prilagojene medicinske pripomočke, ki ustrezajo človeški anatomski strukturi in bolnikom zagotavljajo prilagojene načrte zdravljenja. | Poliranje izdelkov Namen poliranja ortopedskih izdelkov je izboljšati stik med vsadkom in človeškim tkivom, zmanjšati koncentracijo stresa in izboljšati dolgoročno stabilnost vsadka. | Pregled kakovosti Test mehanskih lastnosti ortopedskih izdelkov je zasnovan tako, da simulira stresne razmere človeških kosti, oceni zmogljivosti in trajnost vsadkov v človeškem telesu in zagotavlja njihovo varnost in zanesljivost. |
Paket izdelkov Ortopedski izdelki so pakirani v sterilni sobi, da se zagotovi, da je izdelek zaprt v čisto, sterilno okolje, da se prepreči mikrobna kontaminacija in zagotovi kirurško varnost. |
Skladiščenje ortopedskih izdelkov zahteva strogo upravljanje in nadzor nad kakovostjo in nadzor kakovosti, da se zagotovi sledljivost izdelkov in prepreči iztekanje ali napačno pošiljko. |
Vzorčna soba se uporablja za shranjevanje, prikazovanje in upravljanje različnih vzorcev ortopedskih izdelkov za izmenjave tehnologije izdelkov in usposabljanje. |
1. Vprašajte XC Medico Ekipa za katalog izdelkov brez cementne revizije.
2. Izberite svoj zainteresiran izdelek brez cementne revizije HIP.
3. Prosite za vzorec za testiranje revizijskega kolka brez cemenlja.
4. Vzemite vrstni red revizijskega kolka XC Medico.
5.ED Trgovina XC Medicovega revizijskega kolka.
1.Better Nakupne cene revizijskega kolka brez cemenlja.
2,100% najvišje kakovostni revizijski kolk.
3. Manj prizadevanja za naročanje.
4. stabilnost cen za obdobje dogovora.
5. Zadostno revizijsko revizijsko kolko.
6. Hitra in enostavna ocena revizijskega kolka XC Medico.
7. Globalno priznana blagovna znamka - XC Medico.
8. Čas hitrega dostopa do prodajne ekipe XC Medico.
9. Dodatni preizkus kakovosti s strani XC Medicove ekipe.
10. Sledite svojemu naročilo XC Medica od začetka do konca.
Implantat za kolke brez cementiranja predstavlja življenjsko napredovanje na področju ortopedske kirurgije, zlasti pri reševanju zapletov, povezanih z neuspeli ali dotrajani zamenjavi kolka. Ti vsadki so zasnovani za izboljšanje mobilnosti, zmanjšanje bolečine in obnavljanje funkcionalnosti brez uporabe kostnih cementa. Ta priročnik ponuja poglobljen pregled revizijskih bokov brez cemenlja, raziskuje njihove značilnosti, prednosti, aplikacije in prihodnji tržni potencial, ki skrbi za ortopedske strokovnjake in medicinske navdušence.
HIP brez cementnega revizije se nanaša na vrsto vsadka kolka, zasnovan za uporabo v revizijskih operacijah, kjer je predhodno nameščen hip implantat ni uspel, zrahljal ali povzročil zaplete. Za razliko od tradicionalnih vsadkov, ki se za fiksacijo zanašajo na kostni cement, brez cementnih vsadkov z biološko fiksacijo dosežejo stabilnost. To olajša njihova porozna površina, ki spodbuja rast kosti neposredno v implantat, kar ustvarja dolgotrajno in stabilno vez.
Ti vsadki so še posebej primerni za bolnike z dobro kakovostjo kosti in tiste, ki so podvrženi postopkom, kjer je ohranjanje kosti ključnega pomena. Modeli brez cementa so vedno bolj naklonjeni njihovi sposobnosti integracije z naravno strukturo kosti in zmanjšanje tveganja za zaplete, povezane s cementiranimi vsadki.
Porozna prevleka, ki je pogosto narejena iz titana ali hidroksiapatita, spodbuja osseintegracijo, kar omogoča naravno kost v vsadek.
Številni vsadki odlikujejo konično zasnovo stebel, da se doseže varno prileganje v stegnenični kanal, kar izboljšuje začetno stabilnost.
Modularni modeli omogočajo večjo prilagajanje, kar kirurgom omogoča, da prilagodijo implantat bolnikovi edinstveni anatomiji in kostni strukturi.
Visoke trdne materiale, kot so titanove zlitine, se običajno uporabljajo za svojo odlično biokompatibilnost, lahka narava in korozijsko odpornost.
Anatomske zasnove posnemajo naravne obrise stegnenice in acetabuluma, kar povečuje stabilnost vsadka in udobje pacienta.
Sistemi brez cementa pogosto vključujejo možnosti za stebla z podaljšano dolžino in acetabularna povečanja za hude primere izgube kosti.
Biološka fiksacija zagotavlja, da implantat ostane varno pritrjen na kost sčasoma, kar zmanjšuje verjetnost popuščanja ali okvare.
Z odpravo uporabe kostnih cementa, ki lahko služi kot potencialno mesto za rast bakterij, se zmanjša tveganje za pooperativno okužbo.
Modeli brez cementa omogočajo ohranjanje kosti, kar je še posebej koristno pri mlajših bolnikih, ki bodo v prihodnosti morda potrebovali nadaljnje revizije.
Naravna rast kosti v implantat povečuje porazdelitev obremenitve in zmanjšuje zaščito pred stresom, kar vodi do boljših dolgoročnih rezultatov.
Kirurgi lahko implantat prilagodijo posebnim izzivom, kot so izguba kosti ali deformacije, kar izboljšuje kirurške rezultate.
Bolniki pogosto doživljajo hitrejše čase okrevanja in izboljšajo pooperativno mobilnost zaradi varne, naravne fiksacije, ki jo zagotavljajo ti vsadki.
Ko predhodno nameščen kolčni vsadek izgubi pritrditev na kost brez okužbe, implantat brez cementa ponuja stabilno zamenjavo.
V primerih zlomov okoli originalnega implantata lahko konstrukcija brez cemenlja sprejme in stabilizira te zapletene pogoje.
Izguba kosti, ki jo povzročajo obrabe iz prejšnjih vsadkov, je mogoče ublažiti z uporabo vsadkov brez cementa, ki spodbujajo regeneracijo kosti.
Za bolnike s ponavljajočimi se dislokacijami ali nestabilnimi kolčnimi sklepi, brez cementni revizijski vsadki obnovijo pravilno poravnavo in stabilnost.
Po odstranitvi vsadkov in izkoreninjenja okužbe z okužbo in izkoreninjenja okužbe nudijo zanesljivo možnost ponovne implantacije zanesljiva možnost.
V nekaterih primerih lahko naravna kost traja dlje časa, da zraste v implantat, kar vodi do začasne nestabilnosti.
Bolniki s slabo kakovostjo kosti, kot so tisti s hudo osteoporozo, morda ne bodo dosegli ustrezne fiksacije, kar bi povečalo tveganje za odpoved vsadka.
Postopki revizije brez cementov so lahko tehnično zahtevnejši, kar zahteva izkušene kirurge in specializirano opremo.
Nepravilne tehnike implantacije lahko privedejo do zlomov stegnenice ali acetabuluma.
Sčasoma lahko komponente implantata nosijo, kar zahteva nadaljnje revizije.
Brezvezni vsadki so pogosto dražji od cementiranih možnosti, kar lahko za nekatere bolnike omeji dostopnost.
Ker se svetovno prebivalstvo stara, se pričakuje, da se bo povpraševanje po operacijah revizije kolka povečalo, kar bo povečalo potrebo po zanesljivih vsadkih.
Inovacije v biokompatibilnih materialih, kot so bioaktivni premazi in 3D-natisnjeni vsadki, izboljšujejo delovanje sistemov brez cementov.
Naraščajoča prednost biološke fiksacije med kirurgi zagotavlja trajno sprejemanje cementnih vsadkov.
Razširitev zdravstvene infrastrukture v regijah, kot sta Azijsko-Pacifik in Latinska Amerika, ponuja neizkoriščene priložnosti za rast trga.
Vključitev robotskih operacij in orodij za načrtovanje AI-Gend Forming Forming natančnost postopkov brez cementnih implantatov.
HIP brez cemenlja je temelj sodobne ortopedske kirurgije, ki ponuja učinkovito, trajno in biokompatibilno rešitev za primere revizije kolka. Njegova inovativna zasnova spodbuja naravno integracijo kosti in zmanjšuje tveganja, povezana s tradicionalnimi cementiranimi vsadki. Medtem ko je treba skrbno upoštevati kirurške izzive in dejavnike, specifične za bolnika, jih prednosti brez cementnih sistemov postanejo prednostna izbira za številne ortopedske kirurge.
Ker tehnologija še naprej napreduje in povečuje globalno povpraševanje po revizijskih operacijah, bo brezžični revizijski kolk postavljen tako, da bo imel vse pomembnejšo vlogo pri izboljšanju rezultatov pacientov in na novo opredeljevanju standardov pri operaciji nadomestitve kolka.
Topel opomnik: Ta članek je samo za referenco in ne more nadomestiti zdravnikovega strokovnega nasveta. Če imate kakršna koli vprašanja, se posvetujte s svojim zdravnikom.
Vsebina je prazna!
Stik