RP1H a ni
XCmedico a ni
Maxillofacial a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Hming | Milem | Item No. | A sawifiahna |
| 1.5 Hma lam Micro 110°L-Plate hmanga siam a ni | ![]() |
RP1H416XL1L a ni | Hole 4, 0.6mm, 16mm, Vei lamah a awm |
| RP1H416XL1R a ni | Hole 4, 0.6mm, 16mm, Dinglamah a awm | ||
| RP1H520XL1L a ni | Hole 5, 0.6mm, 20mm, Vei lamah a awm | ||
| RP1H520XL1R a ni | Hole 5, 0.6mm, 20mm, Dinglam ah a awm |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team te hnenah 1.5 Maxillofacial Micro 110°L-Plate Product Catalog dil rawh.
2. I duhzawng 1.5 Maxillofacial Micro 110°L-Plate Product thlang rawh.
3. Test turin Sample Dil rawh 1.5 Maxillofacial Micro 110°L-Plate.
4.XC Medico-a 1.5 Maxillofacial Micro 110°L-Plate Order siam a ni.
5.XC Medico-a 1.5 Maxillofacial Micro 110°L-Plate Dealer ni rawh.
1.Maxillofacial Micro 110°L-Plate 1.5 lei man tha zawk.
2.100% Quality sang ber 1.5 Maxillofacial Micro 110°L-Plate hmanga siam a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. 1.5 Maxillofacial Micro 110°L-Plate a tling.
6. XC Medico-in 1.5 Maxillofacial Micro 110°L-Plate a siam chu rang tak leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
1.5 Maxillofacial Micro 110°L-Plate hi specialized implant a ni a, complex maxillofacial fracture siamthatna atana siam a ni. A danglam bik 110° angled design hian hmai ruh inkar emaw, inzawmna emaw-a fracture awmte tan stabilization tha zawk a pe a ni. Precision taka siam a ni a, he micro-thickness plate hi minimal invasiveness pe thei tura duan a ni a, chutih rualin chakna leh support tha ber a awm bawk. He kaihhruaina kimchang tak hian plate-a thil awm dan te, a thatna te, a hlauhawm theih dan te, leh hmai tliak chi hrang hrang enkawlna kawnga a chanvo te a zirchiang a ni. Khawvel pum huapa orthopedic implant market-a a pawimawh zual zel pawh a zirchiang bawk.
1.5 Maxillofacial Micro 110°L-Plate hi orthopedic implant a ni a, hmai ruh ruh tliak, a bik takin mandible emaw maxilla ang chi angular intersection-a awmte fixation-na atana hman a ni. '1.5' hian plate thickness a tarlang a, hei hian durability leh minimal invasiveness a balance a ni. He implant defining feature chu 110° L-shaped design a ni a, complex fracture site-a stability leh alignment pe thei tura engineer a ni. He plate hi trauma leh reconstructive surgery-ah te hman a ni tlangpui a, chu chuan hmai structural integrity leh aesthetics a siam tha leh thin.
Angled structure hi intersection-a fracture awmte tan a tha ber a, complex junction-ah pawh precise alignment leh stability a awm thei a ni.
1.5 mm-ah chuan plate chu a hring a, mahse a chak a, hei hian minimally invasive procedure a phalsak a, tissue irritation a ti tlem bawk.
Titanium hmanga siam a ni tlangpui a, plate hi a rit lo a, a chhe thei lo a, a reactive lo bawk a, hei hian hun rei tak chhunga him taka dah theih a ni.
Strategically placed screw holes hian fixation-ah flexibility a pe a, surgeon-te chuan fracture geometry angin plate chu chiang takin an secure thei a ni.
Surgery neih laiin plate hi kut hmanga contoured theih a ni a, chu chuan damlo taksa peng hrang hrang (unique anatomical structure) nena inmil a nih theih nan a fit leh stability tha ber a siam thei a ni.
110° angle design hian fracture site-ah a bik takin ruh inzawmkhawmna hmunah chuan support leh stability tha zawk a pe a ni.
A micro-thickness leh biocompatible material hian soft tissue irritation leh inflammation risk a ti tlem a, a dam chak zawk a ni.
Plate low profile hian vun hnuaiah hmuh theihna tlem ber a siam a, hmai natural appearance a humhim bawk.
Stable fixation hmang hian damlote chuan jaw leh facial movement te chu a hmain an ti leh thei a, hei hian joint stiffness ang chi complication awm theihna a ti tlem a ni.
Titanium siam hian hun rei tak chhung a daih thei a, chutih rualin adverse reaction emaw implant rejection emaw a awm theihna a ti tlem bawk.
A bik takin 110° design hian natural bone structure a tihchakna hmuna mandible angle emaw body emawa fracture tan a tangkai hle.
Upper jaw-a fracture stabilize nan a tha hle a, a bik takin angled emaw irregular emaw bone segment a awm te chu stabilize nan a tha hle.
Cheekbone-a fracture awmte tan support nghet tak a pe a, alignment dik tak leh aesthetic restoration a tichiang bawk.
Orbital rim chhehvela fracture awmte stabilize-na atan a tangkai a, ocular symmetry vawng reng turin a pui a, enophthalmos ang chi complication a veng thei bawk.
Complex midface fracture-ah chuan plate hian hmai ruh siam thar leh siamhat lehna atana mamawh stability a pe a ni.
Surgery dang ang bawkin, natna kai theihna a awm a, a bik takin aseptic technique zawm loh chuan.
A tlem berah chuan hliam dam tha lo emaw, soft tissue tension lutuk vangin plate chu vun kaltlangin a lang thei a ni.
A dah dik loh chuan a bul hnaia nerve-te hliam a thlen thei a, chu chuan hun eng emaw chen emaw, a awm reng emaw chuan sensory emaw motor deficit a thlen thei a ni.
Stabilization dik lo chuan ruh chu a dam dik lo thei a, chu chuan inrawlh belh a ngai thei a ni.
A tlem hle nachungin, damlo thenkhat chuan titanium emaw, plate-a hman tur thil dang emaw lakah allergy an nei thei a ni.
Bioresorbable materials ang chi material science lama hmasawnna chuan implant chu a him zawk thei a, removal surgery neih a ngai tawh lo thei bawk.
Kawngpui accident, infiamna lama hliam, leh tharum thawhna avanga hmai ruh tliak pung zel hian fixation solution rintlak mamawhna a tipung dawn niin an sawi.
Mi tam zawkin reconstructive leh aesthetic procedure an thlang a, 110°L-Plate ang implant mamawhna a sang chho zel dawn a ni.
Ram thang mektea healthcare service tihpun a nih chuan advanced surgical implant hman a ni lehzual dawn a ni.
1.5 Maxillofacial Micro 110°L-Plate hi implant thar tak a ni a, chakna, precision leh versatility te inzawmkhawmin complex maxillofacial fractures te a hmachhawn thei a ni. A danglam bik 110° angled design hi junctional fracture tan a tha hle a, stability leh alignment tihchakna a pe a ni. Micro-thickness, biocompatibility leh adaptability a neih avangin plate hian functional recovery leh aesthetic restoration pahnih a tichiang a ni. Infection emaw nerve injury emaw ang chi risks associated a awm laiin, surgical planning leh technique dik tak chuan heng complications te hi a tiziaawm thei a ni. Market a lo thang zel a, technology lama hmasawnna leh facial trauma solution mamawhna sang zel avang hian 1.5 Maxillofacial Micro 110°L-Plate hi maxillofacial surgery-a lungphum a la ni reng dawn a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp