RP1H a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Hming | Milem | Item no. | Specification 100 a ni. |
1.5 Maxillofacial Micro Y-plate 1000 a ni. | ![]() |
RP1H624Y1 a ni. | 6 holes, 0.6mm, 24mm a ni. |
RP1H728Y a ni. | 7 holes, 0.6mm, 28mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 1.5 Maxillofacial Micro Y-Plate Product Catalog ah zawhfiah theih a ni.
2. I duh duh thlang rawh 1.5 maxillofacial micro y-plate product.
3. 1.5 maxillofacial micro y-plate test turin sample dil rawh.
4.XC Medico-a 1.5 maxillofacial micro y-plate order siam rawh.
5.XC Medico-a 1.5 maxillofacial micro y-plate-a thil zuartu ni rawh.
1.A lei man tha zawk 1.5 maxillofacial micro y-plate.
2.100% Quality sang ber 1.5 maxillofacial micro y-plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tling tawk 1.5 maxillofacial micro y-plate.
6. XC Medico-a 1.5 maxillofacial micro y-plate-a thil tih dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
1.5 maxillofacial micro y-plate hi precision-engineered orthopedic implant a ni a, maxillofacial fracture enkawlna atana siam bik a ni. A Y-shaped design hian exceptional stability, adaptability, leh facial structure nalh tak tak siam tharna atana hman awlsamna a pe a ni. He guide hian 1.5 maxillofacial micro y-plate chungchang hi thuk takin a hrethiam a, a features, advantages, clinical applications, leh market potential te a huam a ni.
1.5 maxillofacial micro y-plate hi titanium implant te tak te, maxillofacial surgery-a hman thin a ni a, chu chuan hmai ruh nalh tak takah ruh tliak a ti nghet thei a ni. 'y' shape hian fixation point tam tak a pe a, ruh fragment te chu him taka stabilization a awm theih nan a pui a ni. A 1.5mm thickness hian minimally invasive application a siam thei a, hei hian mandible, zygomatic bone, leh orbital rim ang chi hmunah te hman atan a tha hle.
Plate hi a bik takin 1.5mm screw hmanga hnathawh theih tura siam a ni a, puitling leh naupang enkawlna kawngah pawh fixation tha ber a awm thei a ni. A design tlem leh a versatile design hian surgeon-te tan chuan hmai ruhro structure, function, leh aesthetics siam that lehna tura thawktu tan hmanraw pawimawh tak a ni.
Y-configuration danglam tak hian fixation atan arm pathum a pe a, stability sang zawk leh rotational force laka inven theihna a pe bawk. He design hi a bik takin multi-fragmentary fracture-ah a tangkai hle.
High-grade titanium atanga siam, plate hi a rit lo, corrosion-resistant a ni a, ruh nen a inzawm tlat a, allergic reaction emaw implant rejection emaw a awm theihna tur a tlem phah hle.
1.5mm chauh a thuk a nih chuan plate hian a chhehvel soft tissue te tihbuai theihna tlem ber a siam a, hei hian postoperative discomfort leh inflammation a ti tlem a ni.
Plate hi pre-contoured niin hmai ruh anatomical curvature nen a inmil a, intraoperative adjustment time a ti tlem a ni.
Titanium-a radiolucent property hmang hian postoperative imaging chiang tak a awm thei a, hei hian ruh tliak damna enfiahna tha tak a pe thei a ni.
Plate hian 1.5mm screws accommodate laiin fixation strength tihpun nan strategically placed screw holes tam tak a awm a.
Y-shape hian fixation point tam tak a pe a, chu chuan ruh fragment te chu damna kalpui chhung zawngin him taka a inmil theih nan a pui a ni.
A profile thin profile hian surgical incisions a ti tlem a, soft tissue disruption a ti tlem a, recovery rang zawk a siam bawk.
Pre-contoured design hian snug fit a siam a, hei hian intraoperative modification zau tak neih a ngai a, surgeon-te pawhin alignment dik tak an neih theih phah a ni.
Plate hi fracture chi hrang hrang tan a tha a, complex leh multi-fragmentary fracture te pawh a awm a, hei hian hmanraw danglam tak a ni.
Titanium hian corrosion a chakna leh a do theih lohna chuan plate chuan mechanical stress hnuaiah pawh a structural integrity a vawng reng thei a ni.
Facial skeleton-a natural contours siam thar lehin, plate hian cosmetic result tha zawk a thlen theih nan a pui a, hei hi maxillofacial surgery-ah chuan a pawimawh hle.
Plate hian a hnuai lam jaw-a fracture awmte chu a ti nghet a, alignment dik tak leh restoring chewing leh speaking functions a awm theih nan a enkawl a ni.
Cheekbone area-a fracture awm tan chuan plate hian fixation him tak a pe a, hmai symmetry leh function siam thatna kawngah a pui bawk.
Orbital fracture-ah chuan plate hian mit socket structure a vawng reng thei a, hei hian enophthalmos (sunken eye) emaw double vision ang chi harsatna a thlen thei a ni.
A lian lo hle a, 1.5mm screw nena a inmilna hian naupangte hman atan a tha hle a, chutah chuan implant te zawk leh nalh zawk a ngai a ni.
Y-shaped design hian ruh tliak tam tak awmna fracture-te tan stabilization tha tak a pe a, displacement a veng a, damna tha tak a thlen thei bawk.
Plate hi procedure-ah pawh congenital deformities emaw acquired skeletal abnormalities emaw acquired skeletal abnormalities siamthat nan an hmang bawk.
Surgical procedure eng pawh ang bawkin implant site-ah hian natna kai theihna a awm bawk. Hei hi aseptic technique dik tak leh postoperative care hmanga tih tlem theih a ni.
A tlem berah chuan stress nasa lutuk emaw, fixation tha lo emaw chuan implant a tichhia thei a, revision surgery a ngai thei bawk.
Irritation tlem thei ang bera siam ni mah se, dah dik loh emaw, pressure tam lutuk emaw chuan hrehawmna emaw, inflammation emaw a thlen thei a ni.
A then phei chuan hun kal zelah screw te chu a lo chhuak thei a, fixation stability a tichhe thei a, intervention dang a ngai thei bawk.
Plate-in stabilization tling a pek loh emaw, ruh fragment a inmil loh emaw chuan, fracture chu a dam thei lo emaw, a dam dik lo emaw a ni thei.
Plate emaw screw emaw dah dik loh chuan a bul hnaia nerve emaw thisen kalna kawng emaw a tichhia thei a, chu chuan harsatna emaw, hnathawh that lohna emaw a thlen thei a ni.
Kawngpuiah lirthei accident, infiamna lama hliam tuar, leh hnathawhna hmuna hliam tuar tam zel chuan advanced maxillofacial fixation devices mamawhna a tipung hle.
Minimally invasive technique hman a nih chhoh zel hian 1.5 maxillofacial micro y-plate ang chi implant te, versatile tak tak hman a tipung a ni.
Mipui an upa chhoh zel chuan ruh tliak leh reconstructive surgery vei tamna a sang chho zel dawn a, hei hian implant chhe thei lo leh tha tak tak mamawhna a tipung dawn a ni.
Implant design leh materials lama hmasawnna chhunzawm zel chuan maxillofacial plate-te hnathawh leh hman theihna a tichak a ni.
Emerging market-a healthcare infrastructure tihchangtlun hian surgical solution hmasawn tak tak a hmuh theihna a tipung a, hei hian khawvel puma market a tipung a ni.
1.5 maxillofacial micro y-plate hi implant specialized tak a ni a, maxillofacial fracture hrang hrang tan fixation him tak a awm theih nan siam a ni. A Y-shaped design, biocompatible material, leh minimally invasive profile te hian facial trauma case-a functionality leh aesthetics pahnih siam that tumna surgeon-te tan duhthlanna duh ber a ni.
Infection leh implant failure ang chi hlauhawmna awm thei chu uluk taka enkawl a ngai laiin, plate-a ṭhatnate—chutah chuan stability tihpun, precision fit, leh versatility te pawh a tel—chu chu tunlai maxillofacial surgery-ah chuan hmanraw hlu tak a ni. Technology leh surgical technique lama hmasawnna a awm zel avangin 1.5 maxillofacial micro y-plate hian hmai ruh tliak enkawlna kawngah hian hmun pawimawh tak a chang ngei tura ngaih a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | Milem | Item no. | Specification 100 a ni. |
1.5 Maxillofacial Micro Y-plate 1000 a ni. | ![]() |
RP1H624Y1 a ni. | 6 holes, 0.6mm, 24mm a ni. |
RP1H728Y a ni. | 7 holes, 0.6mm, 28mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 1.5 Maxillofacial Micro Y-Plate Product Catalog ah zawhfiah theih a ni.
2. I duh duh thlang rawh 1.5 maxillofacial micro y-plate product.
3. 1.5 maxillofacial micro y-plate test turin sample dil rawh.
4.XC Medico-a 1.5 maxillofacial micro y-plate order siam rawh.
5.XC Medico-a 1.5 maxillofacial micro y-plate-a thil zuartu ni rawh.
1.A lei man tha zawk 1.5 maxillofacial micro y-plate.
2.100% Quality sang ber 1.5 maxillofacial micro y-plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tling tawk 1.5 maxillofacial micro y-plate.
6. XC Medico-a 1.5 maxillofacial micro y-plate-a thil tih dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
1.5 maxillofacial micro y-plate hi precision-engineered orthopedic implant a ni a, maxillofacial fracture enkawlna atana siam bik a ni. A Y-shaped design hian exceptional stability, adaptability, leh facial structure nalh tak tak siam tharna atana hman awlsamna a pe a ni. He guide hian 1.5 maxillofacial micro y-plate chungchang hi thuk takin a hrethiam a, a features, advantages, clinical applications, leh market potential te a huam a ni.
1.5 maxillofacial micro y-plate hi titanium implant te tak te, maxillofacial surgery-a hman thin a ni a, chu chuan hmai ruh nalh tak takah ruh tliak a ti nghet thei a ni. 'y' shape hian fixation point tam tak a pe a, ruh fragment te chu him taka stabilization a awm theih nan a pui a ni. A 1.5mm thickness hian minimally invasive application a siam thei a, hei hian mandible, zygomatic bone, leh orbital rim ang chi hmunah te hman atan a tha hle.
Plate hi a bik takin 1.5mm screw hmanga hnathawh theih tura siam a ni a, puitling leh naupang enkawlna kawngah pawh fixation tha ber a awm thei a ni. A design tlem leh a versatile design hian surgeon-te tan chuan hmai ruhro structure, function, leh aesthetics siam that lehna tura thawktu tan hmanraw pawimawh tak a ni.
Y-configuration danglam tak hian fixation atan arm pathum a pe a, stability sang zawk leh rotational force laka inven theihna a pe bawk. He design hi a bik takin multi-fragmentary fracture-ah a tangkai hle.
High-grade titanium atanga siam, plate hi a rit lo, corrosion-resistant a ni a, ruh nen a inzawm tlat a, allergic reaction emaw implant rejection emaw a awm theihna tur a tlem phah hle.
1.5mm chauh a thuk a nih chuan plate hian a chhehvel soft tissue te tihbuai theihna tlem ber a siam a, hei hian postoperative discomfort leh inflammation a ti tlem a ni.
Plate hi pre-contoured niin hmai ruh anatomical curvature nen a inmil a, intraoperative adjustment time a ti tlem a ni.
Titanium-a radiolucent property hmang hian postoperative imaging chiang tak a awm thei a, hei hian ruh tliak damna enfiahna tha tak a pe thei a ni.
Plate hian 1.5mm screws accommodate laiin fixation strength tihpun nan strategically placed screw holes tam tak a awm a.
Y-shape hian fixation point tam tak a pe a, chu chuan ruh fragment te chu damna kalpui chhung zawngin him taka a inmil theih nan a pui a ni.
A profile thin profile hian surgical incisions a ti tlem a, soft tissue disruption a ti tlem a, recovery rang zawk a siam bawk.
Pre-contoured design hian snug fit a siam a, hei hian intraoperative modification zau tak neih a ngai a, surgeon-te pawhin alignment dik tak an neih theih phah a ni.
Plate hi fracture chi hrang hrang tan a tha a, complex leh multi-fragmentary fracture te pawh a awm a, hei hian hmanraw danglam tak a ni.
Titanium hian corrosion a chakna leh a do theih lohna chuan plate chuan mechanical stress hnuaiah pawh a structural integrity a vawng reng thei a ni.
Facial skeleton-a natural contours siam thar lehin, plate hian cosmetic result tha zawk a thlen theih nan a pui a, hei hi maxillofacial surgery-ah chuan a pawimawh hle.
Plate hian a hnuai lam jaw-a fracture awmte chu a ti nghet a, alignment dik tak leh restoring chewing leh speaking functions a awm theih nan a enkawl a ni.
Cheekbone area-a fracture awm tan chuan plate hian fixation him tak a pe a, hmai symmetry leh function siam thatna kawngah a pui bawk.
Orbital fracture-ah chuan plate hian mit socket structure a vawng reng thei a, hei hian enophthalmos (sunken eye) emaw double vision ang chi harsatna a thlen thei a ni.
A lian lo hle a, 1.5mm screw nena a inmilna hian naupangte hman atan a tha hle a, chutah chuan implant te zawk leh nalh zawk a ngai a ni.
Y-shaped design hian ruh tliak tam tak awmna fracture-te tan stabilization tha tak a pe a, displacement a veng a, damna tha tak a thlen thei bawk.
Plate hi procedure-ah pawh congenital deformities emaw acquired skeletal abnormalities emaw acquired skeletal abnormalities siamthat nan an hmang bawk.
Surgical procedure eng pawh ang bawkin implant site-ah hian natna kai theihna a awm bawk. Hei hi aseptic technique dik tak leh postoperative care hmanga tih tlem theih a ni.
A tlem berah chuan stress nasa lutuk emaw, fixation tha lo emaw chuan implant a tichhia thei a, revision surgery a ngai thei bawk.
Irritation tlem thei ang bera siam ni mah se, dah dik loh emaw, pressure tam lutuk emaw chuan hrehawmna emaw, inflammation emaw a thlen thei a ni.
A then phei chuan hun kal zelah screw te chu a lo chhuak thei a, fixation stability a tichhe thei a, intervention dang a ngai thei bawk.
Plate-in stabilization tling a pek loh emaw, ruh fragment a inmil loh emaw chuan, fracture chu a dam thei lo emaw, a dam dik lo emaw a ni thei.
Plate emaw screw emaw dah dik loh chuan a bul hnaia nerve emaw thisen kalna kawng emaw a tichhia thei a, chu chuan harsatna emaw, hnathawh that lohna emaw a thlen thei a ni.
Kawngpuiah lirthei accident, infiamna lama hliam tuar, leh hnathawhna hmuna hliam tuar tam zel chuan advanced maxillofacial fixation devices mamawhna a tipung hle.
Minimally invasive technique hman a nih chhoh zel hian 1.5 maxillofacial micro y-plate ang chi implant te, versatile tak tak hman a tipung a ni.
Mipui an upa chhoh zel chuan ruh tliak leh reconstructive surgery vei tamna a sang chho zel dawn a, hei hian implant chhe thei lo leh tha tak tak mamawhna a tipung dawn a ni.
Implant design leh materials lama hmasawnna chhunzawm zel chuan maxillofacial plate-te hnathawh leh hman theihna a tichak a ni.
Emerging market-a healthcare infrastructure tihchangtlun hian surgical solution hmasawn tak tak a hmuh theihna a tipung a, hei hian khawvel puma market a tipung a ni.
1.5 maxillofacial micro y-plate hi implant specialized tak a ni a, maxillofacial fracture hrang hrang tan fixation him tak a awm theih nan siam a ni. A Y-shaped design, biocompatible material, leh minimally invasive profile te hian facial trauma case-a functionality leh aesthetics pahnih siam that tumna surgeon-te tan duhthlanna duh ber a ni.
Infection leh implant failure ang chi hlauhawmna awm thei chu uluk taka enkawl a ngai laiin, plate-a ṭhatnate—chutah chuan stability tihpun, precision fit, leh versatility te pawh a tel—chu chu tunlai maxillofacial surgery-ah chuan hmanraw hlu tak a ni. Technology leh surgical technique lama hmasawnna a awm zel avangin 1.5 maxillofacial micro y-plate hian hmai ruh tliak enkawlna kawngah hian hmun pawimawh tak a chang ngei tura ngaih a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp