RP4H a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
FedEx chuan a ti a. dhl.tnt.ems.etc 1000 a ni.
A awm theihna: | |
---|---|
Zat: | |
Hming | Milem | Item no. | Specification 100 a ni. |
2.4 sak tharna flat 120°L-plate (unlocking) . | ![]() |
RP4H13CXLL a ni. | 13 holes, 2.4mm, 97mm, veilam |
RP4H13CXLR a ni. | 13 holes, 2.4mm, 97mm, dinglam | ||
RP4H15cxll a ni. | Hole 15, 2.4mm, 114mm, veilamah | ||
RP4H15CXLR a ni. | 15 holes, 2.4mm, 114mm, dinglam | ||
RP4H19cxll a ni. | 19 holes, 2.4mm, 148mm, veilam | ||
RP4H19CXLR a ni. | 19 holes, 2.4mm, 148mm, dinglam | ||
RP4H23CXLL a ni. | 23 holes, 2.4mm, 182mm, veilam | ||
RP4H23CXLR a ni. | A rilru a buai em em a, a rilru a hah em em bawk a. 2.4mm, 182mm, dinglam |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 2.4 Reconstruction Flat 120°L-Plate Product Catalog-ah zawt rawh.
2. I duh duh thlang rawh 2.4 Reconstruction Flat 120°L-Plate product.
3. Reconstruction flat 120°L-plate test turin sample dil rawh.
4.XC Medico-in 2.4 reconstruction flat 120°L-plate order a siam.
5.XC Medico-a 2.4 reconstruction flat 120°L-plate-a dealer ni rawh.
1.A lei man a tha zawk 2.4 Reconstruction flat 120°L-plate.
2.100% Quality sang ber 2.4 Reconstruction flat 120°L-plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tawk 2.4 Reconstruction flat 120°L-plate.
6. XC Medico-in 2.4 reconstruction flat 120°L-plate a siam dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
2.4 reconstruction flat 120°L-plate hi advanced orthopedic implant a ni a, complex bone structure-a fractures stable fixation leh reconstruction atana siam a ni. He guide hian he specialized implant-a features, advantages, treatment applications, potential risks, leh nakin lawka market prospects te chu ngun takin a zirchiang a ni. A design leh biomechanical property te a tha em em a, 2.4 reconstruction flat 120°L-plate hi fracture chi hrang hrang buaipuitu orthopedic surgeon te tan chuan hmanraw pawimawh tak a ni ta a ni.
2.4 reconstruction flat 120°L-plate hi titanium-based orthopedic plate a ni a, ruh tliakte siam thar lehna tur atana siam a ni a, a bik takin stability sang tak mamawhna hmunah a ni. '120°' angle hian plate-a geometry bik a kawk a, chu chu fixation leh bone alignment tling tak pekna atana pawimawh tak a ni a, a bik takin complex fracture case-ah chuan a pawimawh hle. Plate hi a flat a, L-shaped structure a nei a, chu chuan bone fragments te chu angle tha takah stabilizing hmangin enhanced support a pe a ni.
He implant hi ruh sei tak tak, femur, tibia, humerus, leh pelvis-a ruh tliakte tan a tha hle a, chutah chuan ruh tliakte chu damna ha tak neih nan a pawimawh hle. A design chuan plate chu ruh chung lamah a inmil tha hle a, chutih rualin a dam laiin ruh chunga mechanical load dahte tuar thei tur chakna mamawh a pe bawk.
Plate hi 120° bend hmanga siam a ni a, alignment dik tak vawng reng chungin bone fixation lamah pawh flexibility sang tak a pe thei a ni.
Plate flat structure hian ruh chunglam nena inzawmna tha ber a siam a, stability nasa zawk a awm theih bakah plate displacement hlauhawmna a ti tlem bawk.
High-strength titanium alloy hmanga siam niin, plate hi a rit lo a, a biocompatible a, corrosion a do thei a, dam rei theihna a siam a, implant nena inzawm harsatna awm thei tur a ti tlem bawk.
Plate hian strategically placed screw holes engemaw zat a nei a, chu chuan 2.4mm screw hmangin fixation him tak a siam thei a ni. Heng screw te hian fixation dik leh rigid tak a pe a, screw loosening chance a ti tlem hle.
Plate hi ruh anatomical shape nena inmil turin pre-contoured a ni a, hei hian intraoperative adjustment a mamawhna a ti tlem a, surgery rang zawk leh awlsam zawk a siam thei bawk.
Titanium-a radiolucent property-te chuan plate-in imaging technique a tihbuai loh nan a enkawl a, hei hian postoperative monitoring atan clear x-ray emaw CT scan emaw a ti thei a ni.
120° L-shape design danglam tak hian stability nghet tak a pe a, a bik takin ruh sei tak tak emaw, complex multi-fragmented fractures emaw hmanga fracture-ah te a awm a ni. Design hian a dam chhunga ruh fragments displacing awm theihna a ti tlem a ni.
Pre-contoured design hian minimally invasive procedures a siam thei a, hei hian soft tissue dissection zau tak neih a ngai a ni. Hei hian trauma tlem zawk leh recovery time tawi zawk a thlen thin.
Plate-in a pek theih tur optimal alignment leh stable fixation chuan ruh fragment-te chu a awmna tur dik taka a dam theih nan a pui a, chu chuan non-union emaw malunion emaw a awm theihna a ti tlem a ni.
2.4 reconstruction flat 120°L-plate hi versatile tak a ni a, orthopedic case hrang hrangah hman theih a ni a, femur, tibia, humerus, leh pelvis te fracture te pawh a tel a, hei hian fracture complex tak tak buaipuitu surgeon te tan hmanraw pawimawh tak a ni.
Titanium atanga siam niin, plate hian corrosion leh wear lakah a do thei hle a, mechanical stress sang tak hnuaiah pawh hun rei tak chhunga performance a awm theih phah a ni.
He plate hi femur, tibia, leh humerus ruh tliakte tan a tha hle a, a dam chhunga ruh chi hrang hrang lian tak tak inzawmkhawmna tur chakna mamawh a pe a ni.
120° L-plate hi pelvic fractures stabilization-ah a tangkai hle a, pelvis-a alignment leh support dik tak a awm theihna tur a ni a, hei hi a structural integrity vawng reng tura pawimawh tak a ni.
Ruh chi hrang hrang tam tak awmna fracture-ah chuan, plate hian a dam laiin a zung zawng zawng chu a hmuna vawn theihna kawng rintlak tak a pe a ni.
Joint chhehvela ruh tliak, khup emaw, a ke emaw hnaih ang chite tan chuan 2.4 reconstruction flat 120°L-plate hian joint-a hnathawh dan siamṭhat leh post-traumatic arthritis venna atana mamawh rigidity a pe a ni.
He plate hi osteotomy procedure-ah pawh hman a ni a, chutah chuan ruhte chu tumruh takin deformities siamthat nan emaw, surgical reason dang vang emaw a ni. A design dik tak chuan ruh chu a dah leh hnuah alignment leh stability dik tak a siam thei a ni.
Surgical procedure dang ang bawkin implant hmunah hian natna kai theihna a awm bawk. He hlauhawmna tihtlem nan hian aseptic technique leh postoperative care khauh taka zawm hi a pawimawh hle.
Titanium hi a chhe thei lo hle nachungin, i beisei angin ruh a dam loh emaw, stress nasa lutuk avanga plate a lo chhuah chuan implant failure a la awm thei lo.
Surgery neih lai hian a bul hnaia nerve emaw thisen kalna kawng emaw tihchhiat theihna a awm a, a bik takin complex fracture case-ah emaw, surgery neihna hmun a harsat hunah emaw a awm theih phah a ni.
A then phei chuan fixation tha tak awm mahse, ruhte chu a dam tha thei lo (non-union) emaw, a dam dik lo (malunion), hnathawh that lohna emaw, revision surgery mamawhna emaw a thlen thei.
Plate chu a nghet taka dah a nih loh chuan hun kal zelah a inthlak thei a, fracture fixation stability a tichhe thei a, intervention dang a ngai belh thei bawk.
Khawvel pumah kawngpui accident leh infiamna lama hliam a pun zel avangin 2.4 Reconstruction Flat 120°L-Plate ang chi advanced surgical implant mamawhna a pung zel a ni.
Osteoporosis ang chi dinhmun avang hian mihring tar chak zawkte chuan ruh tliak an tawk nasa zawk a, bone fixation implant mamawhna pawh a sang zel dawn a ni.
Implant material leh design lama minimally invasive technique leh hmasawnna hman a nih chhoh zel chuan 2.4 reconstruction flat 120°L-plate chu fracture treatment complex zawk leh chi hrang hranga hman a nih theih phah mai thei.
Emerging market-a healthcare system a ṭhat chhoh zel chuan surgical implant hmasawn tak takte hmuh theihna a pung zel dawn a, hei hian heng implant-te tana market a tizau lehzual dawn a ni.
Orthopedic reconstructive surgery mamawhna sang zel hian, a bik takin ruh hnathawh leh aesthetics siamhat tumna kawngah hian market hmasawnna a pui lehzual dawn a ni.
2.4 reconstruction flat 120°L-plate hi implant tha tak leh versatile tak a ni a, complex fractures tan exceptional stability a pe a, a bik takin ruh sei leh pelvis-ah te a awm a ni. A 120° L-shaped design hian fixation dik tak a pe a, chutih rualin soft tissue damage a ti tlem a, hei hian orthopedic procedure hrang hrang tan duhthlanna tha tak a ni. Plate-a titanium siam hian hun rei tak chhunga a chhe thei lo a, a chhe thei lo a, a design pre-contoured chuan surgical efficiency a tichak bawk.
Infection leh implant failure ang chi risk awm mahse, hengte hi surgical technique dik tak leh postoperative care hmanga enkawl theih a ni. Trauma a lo pun zel avang te, population a upa chho zel a, surgical technology lama hmasawnna a awm zel avangin 2.4 reconstruction flat 120°L-plate market chu a zau chho zel dawn a ni. He implant hi orthopedic surgeon te tan hmanraw pawimawh tak a ni a, ruh tliak reconstruction nei damlote tan functional leh aesthetic benefits pahnih a pe a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | Milem | Item no. | Specification 100 a ni. |
2.4 sak tharna flat 120°L-plate (unlocking) . | ![]() |
RP4H13CXLL a ni. | 13 holes, 2.4mm, 97mm, veilam |
RP4H13CXLR a ni. | 13 holes, 2.4mm, 97mm, dinglam | ||
RP4H15cxll a ni. | Hole 15, 2.4mm, 114mm, veilamah | ||
RP4H15CXLR a ni. | 15 holes, 2.4mm, 114mm, dinglam | ||
RP4H19cxll a ni. | 19 holes, 2.4mm, 148mm, veilam | ||
RP4H19CXLR a ni. | 19 holes, 2.4mm, 148mm, dinglam | ||
RP4H23CXLL a ni. | 23 holes, 2.4mm, 182mm, veilam | ||
RP4H23CXLR a ni. | A rilru a buai em em a, a rilru a hah em em bawk a. 2.4mm, 182mm, dinglam |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 2.4 Reconstruction Flat 120°L-Plate Product Catalog-ah zawt rawh.
2. I duh duh thlang rawh 2.4 Reconstruction Flat 120°L-Plate product.
3. Reconstruction flat 120°L-plate test turin sample dil rawh.
4.XC Medico-in 2.4 reconstruction flat 120°L-plate order a siam.
5.XC Medico-a 2.4 reconstruction flat 120°L-plate-a dealer ni rawh.
1.A lei man a tha zawk 2.4 Reconstruction flat 120°L-plate.
2.100% Quality sang ber 2.4 Reconstruction flat 120°L-plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tawk 2.4 Reconstruction flat 120°L-plate.
6. XC Medico-in 2.4 reconstruction flat 120°L-plate a siam dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
2.4 reconstruction flat 120°L-plate hi advanced orthopedic implant a ni a, complex bone structure-a fractures stable fixation leh reconstruction atana siam a ni. He guide hian he specialized implant-a features, advantages, treatment applications, potential risks, leh nakin lawka market prospects te chu ngun takin a zirchiang a ni. A design leh biomechanical property te a tha em em a, 2.4 reconstruction flat 120°L-plate hi fracture chi hrang hrang buaipuitu orthopedic surgeon te tan chuan hmanraw pawimawh tak a ni ta a ni.
2.4 reconstruction flat 120°L-plate hi titanium-based orthopedic plate a ni a, ruh tliakte siam thar lehna tur atana siam a ni a, a bik takin stability sang tak mamawhna hmunah a ni. '120°' angle hian plate-a geometry bik a kawk a, chu chu fixation leh bone alignment tling tak pekna atana pawimawh tak a ni a, a bik takin complex fracture case-ah chuan a pawimawh hle. Plate hi a flat a, L-shaped structure a nei a, chu chuan bone fragments te chu angle tha takah stabilizing hmangin enhanced support a pe a ni.
He implant hi ruh sei tak tak, femur, tibia, humerus, leh pelvis-a ruh tliakte tan a tha hle a, chutah chuan ruh tliakte chu damna ha tak neih nan a pawimawh hle. A design chuan plate chu ruh chung lamah a inmil tha hle a, chutih rualin a dam laiin ruh chunga mechanical load dahte tuar thei tur chakna mamawh a pe bawk.
Plate hi 120° bend hmanga siam a ni a, alignment dik tak vawng reng chungin bone fixation lamah pawh flexibility sang tak a pe thei a ni.
Plate flat structure hian ruh chunglam nena inzawmna tha ber a siam a, stability nasa zawk a awm theih bakah plate displacement hlauhawmna a ti tlem bawk.
High-strength titanium alloy hmanga siam niin, plate hi a rit lo a, a biocompatible a, corrosion a do thei a, dam rei theihna a siam a, implant nena inzawm harsatna awm thei tur a ti tlem bawk.
Plate hian strategically placed screw holes engemaw zat a nei a, chu chuan 2.4mm screw hmangin fixation him tak a siam thei a ni. Heng screw te hian fixation dik leh rigid tak a pe a, screw loosening chance a ti tlem hle.
Plate hi ruh anatomical shape nena inmil turin pre-contoured a ni a, hei hian intraoperative adjustment a mamawhna a ti tlem a, surgery rang zawk leh awlsam zawk a siam thei bawk.
Titanium-a radiolucent property-te chuan plate-in imaging technique a tihbuai loh nan a enkawl a, hei hian postoperative monitoring atan clear x-ray emaw CT scan emaw a ti thei a ni.
120° L-shape design danglam tak hian stability nghet tak a pe a, a bik takin ruh sei tak tak emaw, complex multi-fragmented fractures emaw hmanga fracture-ah te a awm a ni. Design hian a dam chhunga ruh fragments displacing awm theihna a ti tlem a ni.
Pre-contoured design hian minimally invasive procedures a siam thei a, hei hian soft tissue dissection zau tak neih a ngai a ni. Hei hian trauma tlem zawk leh recovery time tawi zawk a thlen thin.
Plate-in a pek theih tur optimal alignment leh stable fixation chuan ruh fragment-te chu a awmna tur dik taka a dam theih nan a pui a, chu chuan non-union emaw malunion emaw a awm theihna a ti tlem a ni.
2.4 reconstruction flat 120°L-plate hi versatile tak a ni a, orthopedic case hrang hrangah hman theih a ni a, femur, tibia, humerus, leh pelvis te fracture te pawh a tel a, hei hian fracture complex tak tak buaipuitu surgeon te tan hmanraw pawimawh tak a ni.
Titanium atanga siam niin, plate hian corrosion leh wear lakah a do thei hle a, mechanical stress sang tak hnuaiah pawh hun rei tak chhunga performance a awm theih phah a ni.
He plate hi femur, tibia, leh humerus ruh tliakte tan a tha hle a, a dam chhunga ruh chi hrang hrang lian tak tak inzawmkhawmna tur chakna mamawh a pe a ni.
120° L-plate hi pelvic fractures stabilization-ah a tangkai hle a, pelvis-a alignment leh support dik tak a awm theihna tur a ni a, hei hi a structural integrity vawng reng tura pawimawh tak a ni.
Ruh chi hrang hrang tam tak awmna fracture-ah chuan, plate hian a dam laiin a zung zawng zawng chu a hmuna vawn theihna kawng rintlak tak a pe a ni.
Joint chhehvela ruh tliak, khup emaw, a ke emaw hnaih ang chite tan chuan 2.4 reconstruction flat 120°L-plate hian joint-a hnathawh dan siamṭhat leh post-traumatic arthritis venna atana mamawh rigidity a pe a ni.
He plate hi osteotomy procedure-ah pawh hman a ni a, chutah chuan ruhte chu tumruh takin deformities siamthat nan emaw, surgical reason dang vang emaw a ni. A design dik tak chuan ruh chu a dah leh hnuah alignment leh stability dik tak a siam thei a ni.
Surgical procedure dang ang bawkin implant hmunah hian natna kai theihna a awm bawk. He hlauhawmna tihtlem nan hian aseptic technique leh postoperative care khauh taka zawm hi a pawimawh hle.
Titanium hi a chhe thei lo hle nachungin, i beisei angin ruh a dam loh emaw, stress nasa lutuk avanga plate a lo chhuah chuan implant failure a la awm thei lo.
Surgery neih lai hian a bul hnaia nerve emaw thisen kalna kawng emaw tihchhiat theihna a awm a, a bik takin complex fracture case-ah emaw, surgery neihna hmun a harsat hunah emaw a awm theih phah a ni.
A then phei chuan fixation tha tak awm mahse, ruhte chu a dam tha thei lo (non-union) emaw, a dam dik lo (malunion), hnathawh that lohna emaw, revision surgery mamawhna emaw a thlen thei.
Plate chu a nghet taka dah a nih loh chuan hun kal zelah a inthlak thei a, fracture fixation stability a tichhe thei a, intervention dang a ngai belh thei bawk.
Khawvel pumah kawngpui accident leh infiamna lama hliam a pun zel avangin 2.4 Reconstruction Flat 120°L-Plate ang chi advanced surgical implant mamawhna a pung zel a ni.
Osteoporosis ang chi dinhmun avang hian mihring tar chak zawkte chuan ruh tliak an tawk nasa zawk a, bone fixation implant mamawhna pawh a sang zel dawn a ni.
Implant material leh design lama minimally invasive technique leh hmasawnna hman a nih chhoh zel chuan 2.4 reconstruction flat 120°L-plate chu fracture treatment complex zawk leh chi hrang hranga hman a nih theih phah mai thei.
Emerging market-a healthcare system a ṭhat chhoh zel chuan surgical implant hmasawn tak takte hmuh theihna a pung zel dawn a, hei hian heng implant-te tana market a tizau lehzual dawn a ni.
Orthopedic reconstructive surgery mamawhna sang zel hian, a bik takin ruh hnathawh leh aesthetics siamhat tumna kawngah hian market hmasawnna a pui lehzual dawn a ni.
2.4 reconstruction flat 120°L-plate hi implant tha tak leh versatile tak a ni a, complex fractures tan exceptional stability a pe a, a bik takin ruh sei leh pelvis-ah te a awm a ni. A 120° L-shaped design hian fixation dik tak a pe a, chutih rualin soft tissue damage a ti tlem a, hei hian orthopedic procedure hrang hrang tan duhthlanna tha tak a ni. Plate-a titanium siam hian hun rei tak chhunga a chhe thei lo a, a chhe thei lo a, a design pre-contoured chuan surgical efficiency a tichak bawk.
Infection leh implant failure ang chi risk awm mahse, hengte hi surgical technique dik tak leh postoperative care hmanga enkawl theih a ni. Trauma a lo pun zel avang te, population a upa chho zel a, surgical technology lama hmasawnna a awm zel avangin 2.4 reconstruction flat 120°L-plate market chu a zau chho zel dawn a ni. He implant hi orthopedic surgeon te tan hmanraw pawimawh tak a ni a, ruh tliak reconstruction nei damlote tan functional leh aesthetic benefits pahnih a pe a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp