RP135DHS
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Pic | Screw | REF. | Spec. |
135° DHS Plate | HA 4.5 Lag Screw | RP135DHS3H | 3H | |
RP135DHS4H | 4H | |||
RP135DHS5H | 5H | |||
RP135DHS6H | 6H | |||
RP135DHS7H | 7H | |||
RP135DHS8H | 8H | |||
RP135DHS9H | 9H | |||
RP135DHS10H | 10H | |||
RP135DHS11H | 11H | |||
RP135DHS12H | 12H |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 135° DHS Plate Product Catalog.
2. Choose Your Interested 135° DHS Plate Product.
3. Ask For A Sample To Test 135° DHS Plate.
4.Make An Order Of XC Medico's 135° DHS Plate.
5.Become A Dealer Of XC Medico's 135° DHS Plate.
1.Better Purchase Prices Of 135° DHS Plate.
2.100% The Highest Quality 135° DHS Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 135° DHS Plate.
6. Quick And Easy Assessment Of XC Medico's 135° DHS Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 135° DHS Plate is a critical orthopedic implant used primarily for the treatment of femoral neck fractures, intertrochanteric fractures, and other related injuries. It is part of the dynamic hip screw (DHS) system, an established method for achieving stable internal fixation of hip fractures, particularly in elderly patients or those with osteoporotic bone. This comprehensive guide will explore the key features, advantages, applications, risks, and future market potential of the 135° DHS Plate, helping medical professionals understand its role in modern orthopedic practice.
The 135° DHS Plate is a specialized orthopedic device used in conjunction with the dynamic hip screw (DHS) to stabilize femoral fractures. The "135°" refers to the angle between the dynamic screw and the plate, which is designed to mimic the natural alignment of the femur and provide optimal stability during the healing process.
This angle ensures that the screw functions dynamically, allowing slight movement within the fracture site. This movement aids in the formation of callus and promotes healing. The 135° DHS Plate is typically used in patients suffering from hip fractures.The plate is made from high-strength materials such as stainless steel or titanium, both of which provide superior mechanical properties and biocompatibility, ensuring durability and minimal risk of rejection.
The plate is contoured to fit the natural curvature of the femur, providing a snug and secure fit for optimal fracture stabilization.
The plate utilizes a dynamic locking screw system, allowing the screw to slide slightly within the plate. This controlled movement helps facilitate bone healing by allowing micro-movements at the fracture site, stimulating callus formation.
The 135-degree angle between the dynamic screw and the plate mimics the biomechanical properties of the femur, promoting more efficient weight transfer and reducing the risk of complications.
The plate includes several screw holes that enable flexibility in screw placement, allowing for individualized fracture management depending on the patient's anatomy and fracture type.
The 135° DHS Plate is made from high-grade stainless steel or titanium alloy, which is known for its strength, corrosion resistance, and lightweight properties, ensuring both durability and comfort for the patient.
The low-profile design minimizes soft tissue irritation, which can be a concern with bulkier implants, contributing to reduced post-operative pain and quicker recovery.
The dynamic screw-locking mechanism ensures excellent fracture stability by allowing limited motion between the screw and the plate, which aids in the formation of callus and bone healing.
The 135-degree angle helps to distribute the mechanical load across the hip joint, which minimizes stress on the implant and reduces the risk of implant failure, particularly in patients with osteoporotic bone.
The angle and design of the plate mimic the natural biomechanics of the hip, ensuring that the patient’s weight is transferred more efficiently during movement, reducing the chances of post-operative complications.
The low-profile design and anatomical fit of the plate reduce soft tissue irritation, which helps with post-surgical comfort and recovery.
The 135° DHS Plate is versatile and can be used in a variety of hip fractures, including those in patients with osteoporosis, elderly patients, and those who may require revision surgery.
The DHS system, which includes the 135° DHS Plate, has been used in clinical practice for decades and has a proven track record of effectiveness in treating hip fractures, especially in geriatric populations.
The 135° DHS Plate is commonly used for fractures that occur just below the head of the femur, often caused by falls or direct trauma. These fractures are challenging to treat due to the importance of maintaining proper alignment and blood supply to the femoral head.
Fractures between the greater and lesser trochanters (the bony prominences of the femur) are common in elderly patients and often result from low-energy falls. The 135° DHS Plate provides stable fixation for these fractures, allowing for early weight-bearing and a quicker recovery.
These fractures occur near the trochanteric region and are typically complex in nature. The 135° DHS Plate is especially beneficial in such cases, offering a stable fixation system and enabling the proper healing of the fracture.
In elderly patients with weakened bone density, fractures in the femoral neck or intertrochanteric region can occur with minimal trauma. The locking mechanism of the 135° DHS Plate offers better stabilization for these fragile bones, reducing the likelihood of non-union or implant failure.
As with any orthopedic surgery, there is a risk of infection at the incision site or around the implant, especially if proper sterile techniques are not followed during surgery.
Although the plate provides excellent stabilization, there is still a possibility that the fracture may not heal properly, resulting in non-union or malunion (misalignment of the fracture during healing).
In some cases, especially in patients with poor bone quality (e.g., osteoporotic bone), the screws or the plate may fail to provide adequate fixation, leading to implant loosening or fracture displacement.
During the surgical procedure, there is a risk of inadvertently damaging blood vessels or nerves, particularly in complex fractures near the hip joint.
Prolonged immobility after surgery may increase the risk of deep vein thrombosis (DVT), particularly in older patients or those with other underlying health conditions.
With the global population aging, particularly in developed countries, the incidence of osteoporotic fractures and femoral fractures in elderly patients is rising, driving the demand for orthopedic implants like the 135° DHS Plate.
Continued improvements in implant materials, such as the development of stronger, more lightweight alloys, will enhance the performance of the 135° DHS Plate, further expanding its usage in clinical practice.
Surgeons are increasingly adopting minimally invasive surgical techniques, which can reduce recovery time and surgical complications. The 135° DHS Plate is compatible with these techniques, ensuring its relevance in future orthopedic practice.
As healthcare infrastructures improve in emerging markets, there will be a greater demand for high-quality orthopedic implants, expanding the market potential for the 135° DHS Plate in these regions.
The 135° DHS Plate is a crucial component of the dynamic hip screw system used to treat femoral neck fractures, intertrochanteric fractures, and other hip injuries. Its unique 135-degree angle, anatomical design, and dynamic locking mechanism provide superior stability and promote healing, making it a reliable choice for both patients and orthopedic surgeons. While there are some risks associated with surgery, the advantages of the 135° DHS Plate far outweigh the potential drawbacks, especially in elderly or osteoporotic patients. With its proven track record, versatility, and growing market demand, the 135° DHS Plate will continue to play a vital role in orthopedic fracture management for years to come.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Pic | Screw | REF. | Spec. |
135° DHS Plate | HA 4.5 Lag Screw | RP135DHS3H | 3H | |
RP135DHS4H | 4H | |||
RP135DHS5H | 5H | |||
RP135DHS6H | 6H | |||
RP135DHS7H | 7H | |||
RP135DHS8H | 8H | |||
RP135DHS9H | 9H | |||
RP135DHS10H | 10H | |||
RP135DHS11H | 11H | |||
RP135DHS12H | 12H |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 135° DHS Plate Product Catalog.
2. Choose Your Interested 135° DHS Plate Product.
3. Ask For A Sample To Test 135° DHS Plate.
4.Make An Order Of XC Medico's 135° DHS Plate.
5.Become A Dealer Of XC Medico's 135° DHS Plate.
1.Better Purchase Prices Of 135° DHS Plate.
2.100% The Highest Quality 135° DHS Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 135° DHS Plate.
6. Quick And Easy Assessment Of XC Medico's 135° DHS Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 135° DHS Plate is a critical orthopedic implant used primarily for the treatment of femoral neck fractures, intertrochanteric fractures, and other related injuries. It is part of the dynamic hip screw (DHS) system, an established method for achieving stable internal fixation of hip fractures, particularly in elderly patients or those with osteoporotic bone. This comprehensive guide will explore the key features, advantages, applications, risks, and future market potential of the 135° DHS Plate, helping medical professionals understand its role in modern orthopedic practice.
The 135° DHS Plate is a specialized orthopedic device used in conjunction with the dynamic hip screw (DHS) to stabilize femoral fractures. The "135°" refers to the angle between the dynamic screw and the plate, which is designed to mimic the natural alignment of the femur and provide optimal stability during the healing process.
This angle ensures that the screw functions dynamically, allowing slight movement within the fracture site. This movement aids in the formation of callus and promotes healing. The 135° DHS Plate is typically used in patients suffering from hip fractures.The plate is made from high-strength materials such as stainless steel or titanium, both of which provide superior mechanical properties and biocompatibility, ensuring durability and minimal risk of rejection.
The plate is contoured to fit the natural curvature of the femur, providing a snug and secure fit for optimal fracture stabilization.
The plate utilizes a dynamic locking screw system, allowing the screw to slide slightly within the plate. This controlled movement helps facilitate bone healing by allowing micro-movements at the fracture site, stimulating callus formation.
The 135-degree angle between the dynamic screw and the plate mimics the biomechanical properties of the femur, promoting more efficient weight transfer and reducing the risk of complications.
The plate includes several screw holes that enable flexibility in screw placement, allowing for individualized fracture management depending on the patient's anatomy and fracture type.
The 135° DHS Plate is made from high-grade stainless steel or titanium alloy, which is known for its strength, corrosion resistance, and lightweight properties, ensuring both durability and comfort for the patient.
The low-profile design minimizes soft tissue irritation, which can be a concern with bulkier implants, contributing to reduced post-operative pain and quicker recovery.
The dynamic screw-locking mechanism ensures excellent fracture stability by allowing limited motion between the screw and the plate, which aids in the formation of callus and bone healing.
The 135-degree angle helps to distribute the mechanical load across the hip joint, which minimizes stress on the implant and reduces the risk of implant failure, particularly in patients with osteoporotic bone.
The angle and design of the plate mimic the natural biomechanics of the hip, ensuring that the patient’s weight is transferred more efficiently during movement, reducing the chances of post-operative complications.
The low-profile design and anatomical fit of the plate reduce soft tissue irritation, which helps with post-surgical comfort and recovery.
The 135° DHS Plate is versatile and can be used in a variety of hip fractures, including those in patients with osteoporosis, elderly patients, and those who may require revision surgery.
The DHS system, which includes the 135° DHS Plate, has been used in clinical practice for decades and has a proven track record of effectiveness in treating hip fractures, especially in geriatric populations.
The 135° DHS Plate is commonly used for fractures that occur just below the head of the femur, often caused by falls or direct trauma. These fractures are challenging to treat due to the importance of maintaining proper alignment and blood supply to the femoral head.
Fractures between the greater and lesser trochanters (the bony prominences of the femur) are common in elderly patients and often result from low-energy falls. The 135° DHS Plate provides stable fixation for these fractures, allowing for early weight-bearing and a quicker recovery.
These fractures occur near the trochanteric region and are typically complex in nature. The 135° DHS Plate is especially beneficial in such cases, offering a stable fixation system and enabling the proper healing of the fracture.
In elderly patients with weakened bone density, fractures in the femoral neck or intertrochanteric region can occur with minimal trauma. The locking mechanism of the 135° DHS Plate offers better stabilization for these fragile bones, reducing the likelihood of non-union or implant failure.
As with any orthopedic surgery, there is a risk of infection at the incision site or around the implant, especially if proper sterile techniques are not followed during surgery.
Although the plate provides excellent stabilization, there is still a possibility that the fracture may not heal properly, resulting in non-union or malunion (misalignment of the fracture during healing).
In some cases, especially in patients with poor bone quality (e.g., osteoporotic bone), the screws or the plate may fail to provide adequate fixation, leading to implant loosening or fracture displacement.
During the surgical procedure, there is a risk of inadvertently damaging blood vessels or nerves, particularly in complex fractures near the hip joint.
Prolonged immobility after surgery may increase the risk of deep vein thrombosis (DVT), particularly in older patients or those with other underlying health conditions.
With the global population aging, particularly in developed countries, the incidence of osteoporotic fractures and femoral fractures in elderly patients is rising, driving the demand for orthopedic implants like the 135° DHS Plate.
Continued improvements in implant materials, such as the development of stronger, more lightweight alloys, will enhance the performance of the 135° DHS Plate, further expanding its usage in clinical practice.
Surgeons are increasingly adopting minimally invasive surgical techniques, which can reduce recovery time and surgical complications. The 135° DHS Plate is compatible with these techniques, ensuring its relevance in future orthopedic practice.
As healthcare infrastructures improve in emerging markets, there will be a greater demand for high-quality orthopedic implants, expanding the market potential for the 135° DHS Plate in these regions.
The 135° DHS Plate is a crucial component of the dynamic hip screw system used to treat femoral neck fractures, intertrochanteric fractures, and other hip injuries. Its unique 135-degree angle, anatomical design, and dynamic locking mechanism provide superior stability and promote healing, making it a reliable choice for both patients and orthopedic surgeons. While there are some risks associated with surgery, the advantages of the 135° DHS Plate far outweigh the potential drawbacks, especially in elderly or osteoporotic patients. With its proven track record, versatility, and growing market demand, the 135° DHS Plate will continue to play a vital role in orthopedic fracture management for years to come.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact