RP4HS a ni.
xcmedico 1000 a ni.
1 PCs-Darkar 72 chhunga pek chhuah theih!
Titanium alloy a ni a.
CE/ISO:9001/ISO13485.etc
Ni 15 chhunga an duh ang anga siam chhuah theihna-thawn hun chhung tel lo)
Fe
A awm theihna: | |
---|---|
Zat: | |
Hming | Milem | Item no. | Specification 100 a ni. |
2.4 Locking siam thar lehna flat straight plate . | ![]() ![]() |
RP4HS8CZ a ni. | 8 holes, 2.4mm, 69mm a ni. |
RP4HS10CZ a ni. | 10 holes, 2.4mm, 86mm a ni. | ||
RP4HS12CZ a ni. | 12 holes, 2.4mm, 103mm a ni. | ||
RP4HS14CZ a ni. | 14holes, 2.4mm, 120mm a ni. | ||
RP4HS16CZ a ni. | A rilru a buai em em a, a rilru a hah em em bawk a. 2.4mm, 137mm | ||
RP4HS18CZ a ni. | 18 holes, 2.4mm, 154mm a ni. | ||
RP4HS20CZ a ni. | 20 a awm a, 2.4mm, 171mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 2.4 Locking Reconstruction Flat Straight Plate Product Catalogue lock turin zawt rawh.
2. I duh duh thlang rawh 2.4 Locking Reconstruction Flat Straight Plate product.
3. Sample pakhat chu test turin dil la 2.4 Locking Reconstruction Flat Straight Plate.
4.XC Medico-a 2.4 locking reconstruction flat straight plate order siam.
5.XC Medico-a 2.4 locking reconstruction flat straight plate-a dealer ni rawh.
1.A lei man tha zawk 2.4 Locking reconstruction flat straight plate.
2.100% Quality sang ber 2.4 Locking Reconstruction flat straight plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tawk 2.4 Locking Reconstruction flat straight plate.
6. XC Medico-in 2.4 locking reconstruction flat straight plate a siam dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
2.4 locking reconstruction flat straight plate hi orthopedic surgery-a hmanraw pawimawh tak a ni a, a bik takin ruh tliakte siam thar leh stabilization atan a pawimawh hle. He versatile leh durable implant hian structural support leh biomechanical stability pahnih a pe a, hei hian fracture chi hrang hrang enkawlna atana duhthlanna hlu tak a ni. He guide kimchang takah hian 2.4 Locking Reconstruction Flat Straight Plate-a design, features, advantages, clinical applications, risks, leh nakin lawka market trends te kan zirchiang ang a, tunlai orthopedic procedure-a a chanvo hriatthiamna famkim kan pe ang. He guide hi orthopedic surgeon, medical zirlai, leh trauma leh fracture management nena thawk healthcare professional te tan a tangkai hle.
2.4 locking reconstruction flat straight plate hi strength sang tak, anatomically contoured metal plate a ni a, ruh sei leh ruhro hmun danga ruh tliakte fixation-a hman a ni. '2.4' designation tih hian plate lian tham tak a kawk a, chu chu screw diameter 2.4 millimeters nei te nen a inmil a ni. He plate hi a bik takin simple leh complex fractures-ah stable fixation pe thei tura siam a ni a, a bik takin anatomical realignment leh long-term stabilization mamawh te chu a ni.
Plate-a 'locking' feature hian a hmanna tur atana hman tur specialized screws a kawk a ni. Heng locking screw te hian plate-a pre-drilled screw holes te chu engage a, ruh chhunga locking hmangin rigid fixation a siam a ni. He design hian screw loosening risk a ti tlem a, a dam chhungin stability leh mechanical support tha zawk a pe a ni.
2.4 locking reconstruction flat straight plate hi a tlangpuiin medical-grade stainless steel emaw titanium alloy ang chi thil hmanga siam a ni. Heng thilte hian biocompatibility sang tak, chakna leh corrosion do theihna a siam a, hei hi hun rei tak chhunga dinhmun nghet leh damlo himna atana pawimawh tak a ni.
Plate hian a flat, straight shape a nei a, chu chuan fracture hrang hrangah a hnawih theih a, ruh tliak awlsam tak atanga complex reconstruction thlengin a hmang thei a ni. A design dik tak chuan anatomical region hrang hrangah hman theih a ni tih a tichiang a ni.
Plate hian locking screw mechanism a hmang a, chu chuan rigid fixation a pe a ni. Screw te chu plate chhungah direct-in an lock a, hun kal zelah a lo chhuak emaw, a inthlak danglam emaw a veng a, mechanical stress sang tak a awm pawhin.
Plate hi pre-drilled screw holes hmanga siam a ni a, hei hian screw dahna tur dik tak a siam thei a, operation-a hun hman pawh a ti tlem thei bawk. Screw holes te hian customized fixation atan angle hrang hranga locking screw te an dah thei a.
Titanium emaw stainless steel emaw atanga siam niin, plate hian biocompatibility tha tak a pe a, taksa nena inzawm tha tak a nih theih nan leh natna kai emaw, hnawl emaw ang chi harsatna a tihziaawm theih nan a pui bawk.
2.4 locking reconstruction flat straight plate atana hman tur materials te hian tensile strength sang tak a pe thei a, hei hi fractures stabilization leh dam laiin ruh displacement venna atan a pawimawh hle.
Plate hi orthopedic application hrang hrangah hman a ni a, fracture fixation atanga reconstructive surgery thlengin hman a ni. A design hian anatomical region hrang hrang atan a customized theih avangin simple leh complex fractures tan pawh a tha hle.
Plate version thenkhatah chuan ruh natural curvature nena inmil zawk turin anatomical contour tlemte a awm a, hei hian snug fit a tichiang a, fixation overall stability a ti tha bawk.
Locking screw system hian traditional plate nena khaikhin chuan fixation tihchangtlun a pe a, hei hian hun kal zelah screw te chu a lo chhuak lo tih a tichiang a, high-stress activity a awm pawhin.
Pre-drilled holes leh locking mechanism te hian screw te chu chiang takin a dah a, chu chuan malalignment awm theihna a ti tlem a, ruh tliak te chu a tidam tha hle bawk.
Locking mechanism hlawkna pawimawh tak pakhat chu screw loosening venna a ni a, hei hi non-locking screw-a thil awm dan tlangpui a ni. Hei hian fracture site-a hun rei tak chhunga dinhmun nghet tak a neih theihna turin a pui a ni.
2.4 locking reconstruction flat straight plate atanga rigid fixation pek hian ruh dam chak zawk a thlen thei a, a tawpah chuan damlote tan dam leh hun a ti tlem thei a ni.
Plate hian hmun nghet, nghet tak a pek avangin, surgical site-a natna kai theihna chu a tlem phah hle.
Chubakah, plate-a biocompatible materials te hian taksaa adverse reaction awm theihna a ti tlem bawk.
Bones fractured te alignment dik tak a awm theih nan plate hian functional recovery tha zawk a siam a, damlo range of motion a siam tha leh a, hun rei tak chhunga disability awm theihna a ti tlem bawk.
Plate design hian minimally invasive surgery a siam thei a, chu chuan incisions te zawk a thlen a, soft tissue disruption a tlem zawk a, natna kai leh dam rei ang chi complication hlauhawmna a hniam zawk bawk.
Plate hi femur, tibia, leh humerus te ruh tliakna atan hman a ni tlangpui a, chutah chuan alignment dik tak leh stabilization dik tak chu damna dik leh hnathawh thatna atan a pawimawh hle.
Ruh chi hrang hrang inzawmkhawma ruh tliakte tan chuan, locking plate hian ruh fragment te chu a hmuna vawn tlat theihna tur support mamawh a pe a, chu chuan damna tha zawk a siamsak thei a ni.
Ruh a inthlakna hmuna fracture-ah chuan 2.4 locking reconstruction flat straight plate hian alignment dik tak a vawng reng a, a dam chhunga ruh a inthlak loh nan a pui bawk.
Plate hi pelvic bones-a fractures stabilizing-ah a tangkai hle a, chutah chuan anatomical precision hi restoring function atan a pawimawh hle a, deformity emaw impaired mobility emaw ang chi complication awm thei tur venna atan a pawimawh hle bawk.
Bone density chak lo, osteoporosis nei te tan chuan locking plate system hian stability dang a pe belh a, a chhan chu screw loosening a awlsam lo zawk a, fixation rintlak zawk a siam thei bawk.
Plate hmang hian joint area-a ruh tliakte tihngheh nan hman theih a ni a, joint function humhalh a nih theih nan leh hun rei tak chhunga harsatna awm thei, arthritis emaw stiffness emaw a awm loh nan hman theih a ni.
Biocompatible materials hmang mah se, eng surgery-ah pawh natna kai theihna hi ngaihtuahawm a la ni reng. He risk tih tlem nan hian surgical technique dik tak leh post-operative care te hi a pawimawh hle.
Taksa hmun tam takah nerve pawimawh tak tak an hnaih zia ngaihtuah chuan, an tih lai hian nerve tihchhiat theihna a awm thei a ni. Hei hian a natna hmuna a rilru a hah, chak lohna, a nih loh leh hnathawh a hloh thei a ni.
A then phei chuan ruh tliak hi a dam tha lo thei (nonunion) emaw, a dinhmun dik lo (malunion) a dam thei bawk. Hei hian surgical intervention dang a mamawh belh thei bawk.
A tlem hle nachungin, plate chu stress nasa lutuk emaw, ruh damna ṭha lo emaw avângin, revision surgery a ngai a ni.
A then phei chuan damlote chuan plate-a hman tur metal, titanium emaw stainless steel emaw te chu allergy an nei thei bawk. Symptoms te chu implant site-a a hring, a sen emaw, a na emaw a ni thei.
Plate dahnaah hian soft tissue manipulation a ngai a, chu chuan a châng chuan ruh tliakna hmuna ruh, tendon emaw, ligament emaw a chhiat emaw, a dam rei emaw a thlen thei a ni.
Khawvel mipui pung zel, a bik takin kum upa lam demographics-a an pun zel avangin kum lama natna vei, ruh natna (osteoporosis) ang chi natna avanga ruh tliak a pung zel dawn a ni. Hei hian a lehlamah, fracture fixation devices mamawhna a tipung dawn a ni.
Orthopedic material leh surgical technique lama hmasawnna kal zel chuan 2.4 locking reconstruction flat straight plate hman tangkai dan a tichak zel dawn a, surgeon tan pawh duhthlan tur ngaihnawm zawk a ni.
Traffic accident leh sports lama hliam a tam zel avangin fracture fixation system rintlak leh tangkai tak mamawhna a sang chho zel dawn a, hei hian 2.4 locking reconstruction flat straight plate mamawhna a thlawp dawn a ni.
Asia leh Africa-a emerging market-a healthcare access tihpun hian orthopedic device siamtute tan hun remchang thar a siam dawn a, hei hian khawvel puma fracture fixation implant quality sang tak mamawhna a tipung lehzual dawn a ni.
Personalized medicine a lo chhuah takah chuan, nakin lawka orthopedic implant market-ah chuan damlo pakhat zel taksa peng hrang hrangte mamawh bikte ngaihtuah turin custom-tailored devices, locking plate te pawh a tel thei a ni.
2.4 locking reconstruction flat straight plate hi tunlai orthopedic surgery-a thil pawimawh tak a ni a, fracture chi hrang hrang enkawlnaah fixation stability sang zawk, durability, leh versatility a pe a ni. A locking screw mechanism, biocompatible materials, leh fracture hrang hrang atana customized theihna te hian complex trauma cases, long bone fractures, leh reconstructions te tan duhthlanna tha tak a siam a ni. Chutianga tih dan chuan hlauhawmna a keng tel a, chu chu natna hrik kai, nerve chhiatna, leh implant hlawhchhamna te a ni a, a hlawkna chu damna tha zawk, functional recovery, leh complication rates tihtlem kawngah a ni a, 2.4 locking reconstruction flat straight plate chu orthopedic surgeon arsenal-a hmanraw pawimawh tak a ni. Technology lama hmasawnna chhunzawm zel leh healthcare hman theihna a pun zel avangin, he implant hmalam hun tur market chu hmasawnna nasa tak atan a inpeih tawh a, chu chuan orthopedic fracture management-ah investment hlu tak a siam a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Hming | Milem | Item no. | Specification 100 a ni. |
2.4 Locking siam thar lehna flat straight plate . | ![]() ![]() |
RP4HS8CZ a ni. | 8 holes, 2.4mm, 69mm a ni. |
RP4HS10CZ a ni. | 10 holes, 2.4mm, 86mm a ni. | ||
RP4HS12CZ a ni. | 12 holes, 2.4mm, 103mm a ni. | ||
RP4HS14CZ a ni. | 14holes, 2.4mm, 120mm a ni. | ||
RP4HS16CZ a ni. | A rilru a buai em em a, a rilru a hah em em bawk a. 2.4mm, 137mm | ||
RP4HS18CZ a ni. | 18 holes, 2.4mm, 154mm a ni. | ||
RP4HS20CZ a ni. | 20 a awm a, 2.4mm, 171mm a ni. |
CNC Preliminary Processing . Computer numerical control technology hmang hian orthopedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability te mizia a nei a ni. Mihring taksa bung hrang hrang nena inmil tur damdawi hmanrua (customized medical devices) a siam nghal vat thei a, damlote tan mimal enkawlna tur ruahmanna a pe thei bawk. |
Product Polishing 1000 a ni. Orthopedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawmna tur leh implant hun rei tak chhunga dinhmun nghet zawk siam a ni. |
Quality inspection . Orthopedic products mechanical properties test hi mihring ruhte stress conditions simulate na tur a ni a, mihring taksaa implant load-bearing capacity leh durability te endik a, an himna leh rintlakna tur a ni. |
Product Package 1000 a ni. Orthopaedic products te hi sterile room-ah an dah a, chu chuan microbial contamination awm loh nan leh surgery safety a awm loh nan hmun thianghlim leh sterile-a encapsulate a nih theih nan a enkawl a ni. |
Orthopedic products dahkhawmna hian product traceability a awm theih nan leh expiry emaw shipment dik lo emaw a awm loh nan in-and-out management leh quality control khauh tak a mamawh a ni. |
Sample room hi product technology exchange leh training atana orthopedic products sample hrang hrang dahkhawm, phochhuah leh enkawl nan hman a ni. |
1. XC Medico Team hnenah 2.4 Locking Reconstruction Flat Straight Plate Product Catalogue lock turin zawt rawh.
2. I duh duh thlang rawh 2.4 Locking Reconstruction Flat Straight Plate product.
3. Sample pakhat chu test turin dil la 2.4 Locking Reconstruction Flat Straight Plate.
4.XC Medico-a 2.4 locking reconstruction flat straight plate order siam.
5.XC Medico-a 2.4 locking reconstruction flat straight plate-a dealer ni rawh.
1.A lei man tha zawk 2.4 Locking reconstruction flat straight plate.
2.100% Quality sang ber 2.4 Locking Reconstruction flat straight plate.
3. Ordering lama hmalakna tlem zawk.
4. Inremna hun chhung atan man a nghet.
5. A tawk 2.4 Locking Reconstruction flat straight plate.
6. XC Medico-in 2.4 locking reconstruction flat straight plate a siam dan awlsam leh rang taka tehna.
7. Khawvel pum huapa hriat hlawh brand - XC Medico.
8. XC Medico sales team-a kal theihna hun rang tak.
9. XC Medico team ten quality test an neih belh leh theih loh.
10. I XC Medico order chu a tir atanga a tawp thlengin track rawh.
2.4 locking reconstruction flat straight plate hi orthopedic surgery-a hmanraw pawimawh tak a ni a, a bik takin ruh tliakte siam thar leh stabilization atan a pawimawh hle. He versatile leh durable implant hian structural support leh biomechanical stability pahnih a pe a, hei hian fracture chi hrang hrang enkawlna atana duhthlanna hlu tak a ni. He guide kimchang takah hian 2.4 Locking Reconstruction Flat Straight Plate-a design, features, advantages, clinical applications, risks, leh nakin lawka market trends te kan zirchiang ang a, tunlai orthopedic procedure-a a chanvo hriatthiamna famkim kan pe ang. He guide hi orthopedic surgeon, medical zirlai, leh trauma leh fracture management nena thawk healthcare professional te tan a tangkai hle.
2.4 locking reconstruction flat straight plate hi strength sang tak, anatomically contoured metal plate a ni a, ruh sei leh ruhro hmun danga ruh tliakte fixation-a hman a ni. '2.4' designation tih hian plate lian tham tak a kawk a, chu chu screw diameter 2.4 millimeters nei te nen a inmil a ni. He plate hi a bik takin simple leh complex fractures-ah stable fixation pe thei tura siam a ni a, a bik takin anatomical realignment leh long-term stabilization mamawh te chu a ni.
Plate-a 'locking' feature hian a hmanna tur atana hman tur specialized screws a kawk a ni. Heng locking screw te hian plate-a pre-drilled screw holes te chu engage a, ruh chhunga locking hmangin rigid fixation a siam a ni. He design hian screw loosening risk a ti tlem a, a dam chhungin stability leh mechanical support tha zawk a pe a ni.
2.4 locking reconstruction flat straight plate hi a tlangpuiin medical-grade stainless steel emaw titanium alloy ang chi thil hmanga siam a ni. Heng thilte hian biocompatibility sang tak, chakna leh corrosion do theihna a siam a, hei hi hun rei tak chhunga dinhmun nghet leh damlo himna atana pawimawh tak a ni.
Plate hian a flat, straight shape a nei a, chu chuan fracture hrang hrangah a hnawih theih a, ruh tliak awlsam tak atanga complex reconstruction thlengin a hmang thei a ni. A design dik tak chuan anatomical region hrang hrangah hman theih a ni tih a tichiang a ni.
Plate hian locking screw mechanism a hmang a, chu chuan rigid fixation a pe a ni. Screw te chu plate chhungah direct-in an lock a, hun kal zelah a lo chhuak emaw, a inthlak danglam emaw a veng a, mechanical stress sang tak a awm pawhin.
Plate hi pre-drilled screw holes hmanga siam a ni a, hei hian screw dahna tur dik tak a siam thei a, operation-a hun hman pawh a ti tlem thei bawk. Screw holes te hian customized fixation atan angle hrang hranga locking screw te an dah thei a.
Titanium emaw stainless steel emaw atanga siam niin, plate hian biocompatibility tha tak a pe a, taksa nena inzawm tha tak a nih theih nan leh natna kai emaw, hnawl emaw ang chi harsatna a tihziaawm theih nan a pui bawk.
2.4 locking reconstruction flat straight plate atana hman tur materials te hian tensile strength sang tak a pe thei a, hei hi fractures stabilization leh dam laiin ruh displacement venna atan a pawimawh hle.
Plate hi orthopedic application hrang hrangah hman a ni a, fracture fixation atanga reconstructive surgery thlengin hman a ni. A design hian anatomical region hrang hrang atan a customized theih avangin simple leh complex fractures tan pawh a tha hle.
Plate version thenkhatah chuan ruh natural curvature nena inmil zawk turin anatomical contour tlemte a awm a, hei hian snug fit a tichiang a, fixation overall stability a ti tha bawk.
Locking screw system hian traditional plate nena khaikhin chuan fixation tihchangtlun a pe a, hei hian hun kal zelah screw te chu a lo chhuak lo tih a tichiang a, high-stress activity a awm pawhin.
Pre-drilled holes leh locking mechanism te hian screw te chu chiang takin a dah a, chu chuan malalignment awm theihna a ti tlem a, ruh tliak te chu a tidam tha hle bawk.
Locking mechanism hlawkna pawimawh tak pakhat chu screw loosening venna a ni a, hei hi non-locking screw-a thil awm dan tlangpui a ni. Hei hian fracture site-a hun rei tak chhunga dinhmun nghet tak a neih theihna turin a pui a ni.
2.4 locking reconstruction flat straight plate atanga rigid fixation pek hian ruh dam chak zawk a thlen thei a, a tawpah chuan damlote tan dam leh hun a ti tlem thei a ni.
Plate hian hmun nghet, nghet tak a pek avangin, surgical site-a natna kai theihna chu a tlem phah hle.
Chubakah, plate-a biocompatible materials te hian taksaa adverse reaction awm theihna a ti tlem bawk.
Bones fractured te alignment dik tak a awm theih nan plate hian functional recovery tha zawk a siam a, damlo range of motion a siam tha leh a, hun rei tak chhunga disability awm theihna a ti tlem bawk.
Plate design hian minimally invasive surgery a siam thei a, chu chuan incisions te zawk a thlen a, soft tissue disruption a tlem zawk a, natna kai leh dam rei ang chi complication hlauhawmna a hniam zawk bawk.
Plate hi femur, tibia, leh humerus te ruh tliakna atan hman a ni tlangpui a, chutah chuan alignment dik tak leh stabilization dik tak chu damna dik leh hnathawh thatna atan a pawimawh hle.
Ruh chi hrang hrang inzawmkhawma ruh tliakte tan chuan, locking plate hian ruh fragment te chu a hmuna vawn tlat theihna tur support mamawh a pe a, chu chuan damna tha zawk a siamsak thei a ni.
Ruh a inthlakna hmuna fracture-ah chuan 2.4 locking reconstruction flat straight plate hian alignment dik tak a vawng reng a, a dam chhunga ruh a inthlak loh nan a pui bawk.
Plate hi pelvic bones-a fractures stabilizing-ah a tangkai hle a, chutah chuan anatomical precision hi restoring function atan a pawimawh hle a, deformity emaw impaired mobility emaw ang chi complication awm thei tur venna atan a pawimawh hle bawk.
Bone density chak lo, osteoporosis nei te tan chuan locking plate system hian stability dang a pe belh a, a chhan chu screw loosening a awlsam lo zawk a, fixation rintlak zawk a siam thei bawk.
Plate hmang hian joint area-a ruh tliakte tihngheh nan hman theih a ni a, joint function humhalh a nih theih nan leh hun rei tak chhunga harsatna awm thei, arthritis emaw stiffness emaw a awm loh nan hman theih a ni.
Biocompatible materials hmang mah se, eng surgery-ah pawh natna kai theihna hi ngaihtuahawm a la ni reng. He risk tih tlem nan hian surgical technique dik tak leh post-operative care te hi a pawimawh hle.
Taksa hmun tam takah nerve pawimawh tak tak an hnaih zia ngaihtuah chuan, an tih lai hian nerve tihchhiat theihna a awm thei a ni. Hei hian a natna hmuna a rilru a hah, chak lohna, a nih loh leh hnathawh a hloh thei a ni.
A then phei chuan ruh tliak hi a dam tha lo thei (nonunion) emaw, a dinhmun dik lo (malunion) a dam thei bawk. Hei hian surgical intervention dang a mamawh belh thei bawk.
A tlem hle nachungin, plate chu stress nasa lutuk emaw, ruh damna ṭha lo emaw avângin, revision surgery a ngai a ni.
A then phei chuan damlote chuan plate-a hman tur metal, titanium emaw stainless steel emaw te chu allergy an nei thei bawk. Symptoms te chu implant site-a a hring, a sen emaw, a na emaw a ni thei.
Plate dahnaah hian soft tissue manipulation a ngai a, chu chuan a châng chuan ruh tliakna hmuna ruh, tendon emaw, ligament emaw a chhiat emaw, a dam rei emaw a thlen thei a ni.
Khawvel mipui pung zel, a bik takin kum upa lam demographics-a an pun zel avangin kum lama natna vei, ruh natna (osteoporosis) ang chi natna avanga ruh tliak a pung zel dawn a ni. Hei hian a lehlamah, fracture fixation devices mamawhna a tipung dawn a ni.
Orthopedic material leh surgical technique lama hmasawnna kal zel chuan 2.4 locking reconstruction flat straight plate hman tangkai dan a tichak zel dawn a, surgeon tan pawh duhthlan tur ngaihnawm zawk a ni.
Traffic accident leh sports lama hliam a tam zel avangin fracture fixation system rintlak leh tangkai tak mamawhna a sang chho zel dawn a, hei hian 2.4 locking reconstruction flat straight plate mamawhna a thlawp dawn a ni.
Asia leh Africa-a emerging market-a healthcare access tihpun hian orthopedic device siamtute tan hun remchang thar a siam dawn a, hei hian khawvel puma fracture fixation implant quality sang tak mamawhna a tipung lehzual dawn a ni.
Personalized medicine a lo chhuah takah chuan, nakin lawka orthopedic implant market-ah chuan damlo pakhat zel taksa peng hrang hrangte mamawh bikte ngaihtuah turin custom-tailored devices, locking plate te pawh a tel thei a ni.
2.4 locking reconstruction flat straight plate hi tunlai orthopedic surgery-a thil pawimawh tak a ni a, fracture chi hrang hrang enkawlnaah fixation stability sang zawk, durability, leh versatility a pe a ni. A locking screw mechanism, biocompatible materials, leh fracture hrang hrang atana customized theihna te hian complex trauma cases, long bone fractures, leh reconstructions te tan duhthlanna tha tak a siam a ni. Chutianga tih dan chuan hlauhawmna a keng tel a, chu chu natna hrik kai, nerve chhiatna, leh implant hlawhchhamna te a ni a, a hlawkna chu damna tha zawk, functional recovery, leh complication rates tihtlem kawngah a ni a, 2.4 locking reconstruction flat straight plate chu orthopedic surgeon arsenal-a hmanraw pawimawh tak a ni. Technology lama hmasawnna chhunzawm zel leh healthcare hman theihna a pun zel avangin, he implant hmalam hun tur market chu hmasawnna nasa tak atan a inpeih tawh a, chu chuan orthopedic fracture management-ah investment hlu tak a siam a ni.
Warm Reminder: He thuziak hi reference atan chauh a ni a, doctor professional advice pawh a thlak thei lo. Zawhna i neih chuan i attending physician te zawt la.
Inbepawp