R55ZDC a ni
XCmedico a ni
Thoracolumbar Spine a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Thilsiam | Milem | REF | A sawifiahna |
| 5.5 Monoaxial tihtlem dan Screw hmanga siam | ![]() |
R55ZDC5030 a ni | Ф5.0*30mm a ni |
| R55ZDC5035 a ni | Ф5.0*35mm a ni | ||
| R55ZDC5040 a ni | Ф5.0*40mm a ni | ||
| R55ZDC5045 a ni | Ф5.0*45mm a ni | ||
| R55ZDC5535 a ni | Ф5.5*35mm a ni | ||
| R55ZDC5540 a ni | Ф5.5*40mm a ni | ||
| R55ZDC5545 a ni | Ф5.5*45mm a ni | ||
| R55ZDC5550 a ni | Ф5.5*50mm a ni | ||
| R55ZDC6035 a ni | Ф6.0*35mm a ni | ||
| R55ZDC6040 a ni | Ф6.0*40mm a ni | ||
| R55ZDC6045 a ni | Ф6.0*45mm a ni | ||
| R55ZDC6050 a ni | Ф6.0*50mm a ni | ||
| R55ZDC6535 a ni | Ф6.5*35mm a ni | ||
| R55ZDC6540 a ni | Ф6.5*40mm a ni | ||
| R55ZDC6545 a ni | Ф6.5*45mm a ni | ||
| R55ZDC6550 a ni | Ф6.5*50mm a ni | ||
| R55ZDC7035 a ni | Ф7.0*35mm a ni | ||
| R55ZDC7040 a ni | Ф7.0*40mm a ni | ||
| R55ZDC7045 a ni | Ф7.0*45mm a ni | ||
| R55ZDC7050 a ni | Ф7.0*50mm a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team hnenah 5.5 Monoaxial Reduction Screw Product Catalog zawt rawh.
2. I duhzawng 5.5 Monoaxial Reduction Screw Product thlang rawh.
3. Test turin Sample Dil rawh 5.5 Monoaxial Reduction Screw.
4.XC Medico 5.5 Monoaxial Reduction Screw Order siam rawh.
5.XC Medico-a 5.5 Monoaxial Reduction Screw Dealer ni rawh.
1.Monoaxial Reduction Screw 5.5 lei man tha zawk.
2.100% Quality sang ber 5.5 Monoaxial Reduction Screw hmanga siam a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. 5.5 Monoaxial Reduction Screw tling tawk.
6. XC Medico-a 5.5 Monoaxial Reduction Screw hman awlsam leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.

5.5 monoaxial reduction screw hi orthopedic implant hmasawn tak a ni a, spinal fixation system-a precision leh stability atana siam a ni. A rigid design leh reduction theihna avang hian spinal condition complex tak tak, deformities leh traumatic injuries te pawh a hmachhawn theih nan a pawimawh hle. He guide hian 5.5 monoaxial reduction screw features, a thatna leh clinical application te a zirchiang a, medical professional, zirlai leh zirchiangtute tan hriatna chipchiar tak a pe a ni.
5.5 monoaxial reduction screw hi specialized spinal implant a ni a, surgery-a hman thin a ni a, vertebrae te stabilize leh align a ni. '5.5' tih hian 5.5 mm rod nena a inmilna a kawk a, fixation nghet leh rintlak tak a siam thei a ni. 'monoaxial' design hian fixed-angle head a pe a, alignment dik tak neih theihna tura rigidity pawimawh tak a pe a, 'reduction' mechanism erawh chuan displaced vertebral segments controlled correction a phal thung. Titanium emaw cobalt-chromium ang chi biocompatible material atanga siam niin, spinal alignment leh stability tha ber neih theihna turin a pawimawh hle.
Fixation laiin alignment nghet leh dik tak a siam thei.
Displaced vertebrae te controlled repositioning a siam awlsam.
Titanium emaw cobalt-chromium emaw atanga siam a ni a, a chhe thei lo tur leh biocompatibility atan a ni.
Pre-drilling ngai tawh lovin insertion a ti awlsam.
Cortical leh cancellous bone ah anchorage a tichak.
Physiological environment-ah implant dam chhung a ti rei thei.
Fixation nghet tak a pe a, complex spinal deformities leh trauma cases tan a pawimawh hle.
Vertebral alignment dik tak leh load distribution dik tak a siamsak.
Material quality sang tak hian mechanical stress hnuaiah hun rei tak chhung a thawk thei a ni.
Self-tapping design hian surgical complexity leh hun a ti tlem hle.
Spinal condition hrang hrang leh fixation system hrang hrang atan a tha.
Dam chak zawk a tichak a, harsatna awm theihna a ti tlem bawk.
Scoliosis, kyphosis, leh alignment dik lo dangte a siam tha.
Thoracic leh lumbar region-a fracture leh dislocation te chu a stabilize thin.
Spondylolisthesis leh disc degeneration ang chi condition hrang hrangte tan spinal fusion procedure-ah tanpuina a pe thin.
Vertebral tumor lakchhuah hnuah stability a tichiang.
Deformity correction emaw trauma stabilization emaw mamawh damlo naupang zawk tan pawh a hman theih.
Postoperative infection hi a tlem hle nachungin damdawi lam enkawlna a ngai a ni.
Placement dik lo emaw, stress lutuk emaw hian fixation a tichhe thei a ni.
Spinal mechanics danglam hian a kianga vertebral level a nghawng thei a ni.
Stress nasa tak hnuaia screw emaw rod emaw a chhiat tam loh chuan revision surgery a ngai thin.
Hardware prominence hian damlo thenkhatah harsatna a thlen fo thin.
Materials, reduction mechanism, leh surgical techniques lama thil thar siam chhunzawm zel hian performance a tichak a ni.
Spinal deformities, trauma, leh degenerative conditions te pung zel hian adoption a tichak hle.
MIS technique nena inmilna chuan a hmanna a tizau hle.
Tarte zingah spinal disorder vei tam zawk hian market a tizau hle.
Hmasawnna hmuna healthcare infrastructure tihchangtlun hian market tihhmasawn a pui a ni.
5.5 monoaxial reduction screw hi tunlai spinal fixation-a hmanraw pawimawh tak a ni a, stability, precision leh adaptability danglam bik a pe a ni. A design hmasawn tak leh a hman dan hrang hrang avang hian spinal condition buaithlak tak tak enkawlna atana thil pawimawh tak a ni. Technology lama hmasawnna kal zel leh khawvel puma mamawh a pun zel avangin 5.5 monoaxial reduction screw hian surgical outcome tihsan leh damlo enkawlna tihchangtlunna kawngah hmun pawimawh tak a chang dawn a ni.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp