Low-Profile Spinal Fixation hmanga tihdam theih a ni
XC Medico chuan a rawn ti a
Thoracolumbar Spine a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Orthopaedic surgery tih a ni
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
Khawvel hmun hrang hranga orthopaedic surgeon duhthlanna rintlak tak. Premium low-profile (5.5/6.0 dual-purpose) spinal fixation system, a stability danglam tak, soft tissue irritation tihziaawmna, leh anatomical alignment tha ber tura engineer a ni.
Lumbar fixation-a Reduction Polyaxial Pedicle Screw System hman dan dik tak en rawh.
Low-notch core design hian soft tissue irritation, postoperative pain a ti tlem a, anatomical adhesions awm theihna a ti tlem bawk.
Clinically preferred size (5.5/6.0 dual-purpose) hian routine surgical procedure 90% vel a huam a, inventory a ti tha hle.
Integrated low-profile locking design hian anti-rotation stability nasa takin a ti tha a, fixation nghet leh him tak a siam bawk.
He screw hian thread segment hrang hrang pathum a nei a, pitch pawh a danglam thei a, cortical purchase leh stability a tichak hle. Surgical fixation trajectories tam tak a support kim vek a, spinal anatomy hrang hrangah a insiamrem tha hle.
Postoperative X-ray-ah hian segmental stability danglam tak a awm tih hmuhchhuah a ni. Spinal alignment rintlak tak leh operation hnua intervertebral support tha tak a pe bawk.
Pedicle screw fixation hmanlai nena khaikhin chuan Cortical Bone Trajectory (CBT) technique hmang hian incision tenau zawk siam theih a ni. Posterior screw dah tam zawk a nih chuan a chhehvel soft tissue te chhiatna a ti tlem a ni.
Integrated breakaway nut hian MIS Curved Rod nena inzawmna tight, secure, leh visually clear a siam a, construct stability tha ber a tichiang a ni.
Lumbar spondylolisthesis a awm thin
Degenerative disc natna leh instability nei lo
PLIF / TLIF / OLIF hmanga tih dan tur
Thoracolumbar vertebral ruh tliak a awm
Scoliosis leh kyphosis siamthatna
Laminectomy/discectomy hnua ruhro (spinal instability) a awm
✓ Product zawng zawng hian GB/T 13810-2017 nena inmil titanium alloy an hmang vek.
✓ TC4 siam chhuah thiam, mechanical property tha tak leh hahna laka invenna tha tak nei.
✓ Mechanical test te hi kum 3+ chhung archive a ni a, full process traceability a awm theih nan.
✓ Control khauh tak nen ≥98.9% quality rate-ah vawn reng a ni.
✓ Products te hi fine polishing, grinding, leh oxidation te an paltlang a, a rawng leh a roughness a awm reng theih nan.
✓ Sub-micron surgical accuracy atan CNC Turning, Milling, leh Wire EDM te tihchhuah a ni.
✓ Anodizing, Electropolishing, leh Matte/Mirror Finishing te hi a hmasawn ber a ni.
✓ Polyaxial head ang chi complex parts te chu high-strength joining leh meticulous fitting.
5.5mm Spinal Pedicle Screw System insertion awlsam zawk nan hmanraw kimchang tak, optional instrument set a awm a, chubakah spine implant hman theih zawng zawng a awm bawk.
Inbepawp