R55ZDC
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | REF | Specification |
5.5 Monoaxial Reduction Screw | R55ZDC5030 | Ф5.0*30mm | |
R55ZDC5035 | Ф5.0*35mm | ||
R55ZDC5040 | Ф5.0*40mm | ||
R55ZDC5045 | Ф5.0*45mm | ||
R55ZDC5535 | Ф5.5*35mm | ||
R55ZDC5540 | Ф5.5*40mm | ||
R55ZDC5545 | Ф5.5*45mm | ||
R55ZDC5550 | Ф5.5*50mm | ||
R55ZDC6035 | Ф6.0*35mm | ||
R55ZDC6040 | Ф6.0*40mm | ||
R55ZDC6045 | Ф6.0*45mm | ||
R55ZDC6050 | Ф6.0*50mm | ||
R55ZDC6535 | Ф6.5*35mm | ||
R55ZDC6540 | Ф6.5*40mm | ||
R55ZDC6545 | Ф6.5*45mm | ||
R55ZDC6550 | Ф6.5*50mm | ||
R55ZDC7035 | Ф7.0*35mm | ||
R55ZDC7040 | Ф7.0*40mm | ||
R55ZDC7045 | Ф7.0*45mm | ||
R55ZDC7050 | Ф7.0*50mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 5.5 Monoaxial Reduction Screw Product Catalog.
2. Choose Your Interested 5.5 Monoaxial Reduction Screw Product.
3. Ask For A Sample To Test 5.5 Monoaxial Reduction Screw.
4.Make An Order Of XC Medico's 5.5 Monoaxial Reduction Screw.
5.Become A Dealer Of XC Medico's 5.5 Monoaxial Reduction Screw.
1.Better Purchase Prices Of 5.5 Monoaxial Reduction Screw.
2.100% The Highest Quality 5.5 Monoaxial Reduction Screw.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 5.5 Monoaxial Reduction Screw.
6. Quick And Easy Assessment Of XC Medico's 5.5 Monoaxial Reduction Screw.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 5.5 monoaxial reduction screw is an advanced orthopedic implant designed for precision and stability in spinal fixation systems. Its rigid design and reduction capabilities make it indispensable in addressing complex spinal conditions, including deformities and traumatic injuries. This guide delves into the features, advantages, and clinical applications of the 5.5 monoaxial reduction screw, providing detailed insights for medical professionals, students, and researchers.
A 5.5 monoaxial reduction screw is a specialized spinal implant used in surgeries to stabilize and align the vertebrae. The "5.5" refers to its compatibility with 5.5 mm rods, ensuring robust and reliable fixation. The "monoaxial" design offers a fixed-angle head, providing rigidity essential for precise alignment, while the "reduction" mechanism allows controlled correction of displaced vertebral segments. Made from biocompatible materials like titanium or cobalt-chromium, it is crucial in achieving optimal spinal alignment and stability.
Ensures stable and precise alignment during fixation.
Facilitates controlled repositioning of displaced vertebrae.
Constructed from titanium or cobalt-chromium for durability and biocompatibility.
Simplifies insertion by eliminating the need for pre-drilling.
Enhances anchorage in cortical and cancellous bone.
Prolongs the implant's lifespan in the physiological environment.
Provides robust fixation, essential for complex spinal deformities and trauma cases.
Facilitates accurate vertebral alignment and load distribution.
High-quality materials ensure long-term performance under mechanical stress.
The self-tapping design reduces surgical complexity and time.
Suitable for a range of spinal conditions and fixation systems.
Promotes quicker recovery and reduces the risk of complications.
Corrects scoliosis, kyphosis, and other alignment abnormalities.
Stabilizes fractures and dislocations in the thoracic and lumbar regions.
Provides support in spinal fusion procedures for conditions like spondylolisthesis and disc degeneration.
Ensures stability following vertebral tumor removal.
Adaptable for younger patients requiring deformity correction or trauma stabilization.
Postoperative infections, though rare, require medical intervention.
Improper placement or excessive stress can compromise fixation.
Altered spinal mechanics may impact neighboring vertebral levels.
Rare cases of screw or rod breakage under extreme stress necessitate revision surgery.
Hardware prominence can occasionally cause discomfort in certain patients.
Continuous innovations in materials, reduction mechanisms, and surgical techniques enhance performance.
Increasing incidences of spinal deformities, trauma, and degenerative conditions fuel adoption.
Compatibility with MIS techniques broadens its application.
Higher prevalence of spinal disorders among the elderly contributes to market expansion.
Improved healthcare infrastructure in developing regions supports market growth.
The 5.5 monoaxial reduction screw is a vital tool in modern spinal fixation, offering unparalleled stability, precision, and adaptability. Its advanced design and versatile applications make it an essential component in treating complex spinal conditions. With ongoing technological advancements and increasing global demand, the 5.5 monoaxial reduction screw is poised to play a pivotal role in enhancing surgical outcomes and improving patient care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | REF | Specification |
5.5 Monoaxial Reduction Screw | R55ZDC5030 | Ф5.0*30mm | |
R55ZDC5035 | Ф5.0*35mm | ||
R55ZDC5040 | Ф5.0*40mm | ||
R55ZDC5045 | Ф5.0*45mm | ||
R55ZDC5535 | Ф5.5*35mm | ||
R55ZDC5540 | Ф5.5*40mm | ||
R55ZDC5545 | Ф5.5*45mm | ||
R55ZDC5550 | Ф5.5*50mm | ||
R55ZDC6035 | Ф6.0*35mm | ||
R55ZDC6040 | Ф6.0*40mm | ||
R55ZDC6045 | Ф6.0*45mm | ||
R55ZDC6050 | Ф6.0*50mm | ||
R55ZDC6535 | Ф6.5*35mm | ||
R55ZDC6540 | Ф6.5*40mm | ||
R55ZDC6545 | Ф6.5*45mm | ||
R55ZDC6550 | Ф6.5*50mm | ||
R55ZDC7035 | Ф7.0*35mm | ||
R55ZDC7040 | Ф7.0*40mm | ||
R55ZDC7045 | Ф7.0*45mm | ||
R55ZDC7050 | Ф7.0*50mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 5.5 Monoaxial Reduction Screw Product Catalog.
2. Choose Your Interested 5.5 Monoaxial Reduction Screw Product.
3. Ask For A Sample To Test 5.5 Monoaxial Reduction Screw.
4.Make An Order Of XC Medico's 5.5 Monoaxial Reduction Screw.
5.Become A Dealer Of XC Medico's 5.5 Monoaxial Reduction Screw.
1.Better Purchase Prices Of 5.5 Monoaxial Reduction Screw.
2.100% The Highest Quality 5.5 Monoaxial Reduction Screw.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 5.5 Monoaxial Reduction Screw.
6. Quick And Easy Assessment Of XC Medico's 5.5 Monoaxial Reduction Screw.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 5.5 monoaxial reduction screw is an advanced orthopedic implant designed for precision and stability in spinal fixation systems. Its rigid design and reduction capabilities make it indispensable in addressing complex spinal conditions, including deformities and traumatic injuries. This guide delves into the features, advantages, and clinical applications of the 5.5 monoaxial reduction screw, providing detailed insights for medical professionals, students, and researchers.
A 5.5 monoaxial reduction screw is a specialized spinal implant used in surgeries to stabilize and align the vertebrae. The "5.5" refers to its compatibility with 5.5 mm rods, ensuring robust and reliable fixation. The "monoaxial" design offers a fixed-angle head, providing rigidity essential for precise alignment, while the "reduction" mechanism allows controlled correction of displaced vertebral segments. Made from biocompatible materials like titanium or cobalt-chromium, it is crucial in achieving optimal spinal alignment and stability.
Ensures stable and precise alignment during fixation.
Facilitates controlled repositioning of displaced vertebrae.
Constructed from titanium or cobalt-chromium for durability and biocompatibility.
Simplifies insertion by eliminating the need for pre-drilling.
Enhances anchorage in cortical and cancellous bone.
Prolongs the implant's lifespan in the physiological environment.
Provides robust fixation, essential for complex spinal deformities and trauma cases.
Facilitates accurate vertebral alignment and load distribution.
High-quality materials ensure long-term performance under mechanical stress.
The self-tapping design reduces surgical complexity and time.
Suitable for a range of spinal conditions and fixation systems.
Promotes quicker recovery and reduces the risk of complications.
Corrects scoliosis, kyphosis, and other alignment abnormalities.
Stabilizes fractures and dislocations in the thoracic and lumbar regions.
Provides support in spinal fusion procedures for conditions like spondylolisthesis and disc degeneration.
Ensures stability following vertebral tumor removal.
Adaptable for younger patients requiring deformity correction or trauma stabilization.
Postoperative infections, though rare, require medical intervention.
Improper placement or excessive stress can compromise fixation.
Altered spinal mechanics may impact neighboring vertebral levels.
Rare cases of screw or rod breakage under extreme stress necessitate revision surgery.
Hardware prominence can occasionally cause discomfort in certain patients.
Continuous innovations in materials, reduction mechanisms, and surgical techniques enhance performance.
Increasing incidences of spinal deformities, trauma, and degenerative conditions fuel adoption.
Compatibility with MIS techniques broadens its application.
Higher prevalence of spinal disorders among the elderly contributes to market expansion.
Improved healthcare infrastructure in developing regions supports market growth.
The 5.5 monoaxial reduction screw is a vital tool in modern spinal fixation, offering unparalleled stability, precision, and adaptability. Its advanced design and versatile applications make it an essential component in treating complex spinal conditions. With ongoing technological advancements and increasing global demand, the 5.5 monoaxial reduction screw is poised to play a pivotal role in enhancing surgical outcomes and improving patient care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact