Please Choose Your Language

loading a ni

Share to:
facebook ah in share theih a ni
twitter hmanga share theih a ni
line sharing tih a ni
wechat hmanga insem theihna button a ni
linkedin a insem theihna tur a ni
pinterest hmanga insem theihna button
whatsapp share theihna tur a ni
sharethih hi share theih a ni

Femoral Condylus Buttress Plate-I chuan a rawn ti a

  • RPG2KZC a ni

  • XCmedico a ni

  • Femur a ni

  • 1 Pcs(Darkar 72 chhung a rawn thawn)

  • Titanium Alloy hmanga siam a ni

  • A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc

  • Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)

  • FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc

A awm theih dan:
Zat:

A rilru a buai em em a, a rilru a hah em em bawk a. Femoral Condylus Buttress Plate-I Video


A rilru a buai em em a, a rilru a hah em em bawk a. Plate-I PDF

        

A rilru a buai em em a, a rilru a hah em em bawk  a

Thilsiam Pic Inherh REF. Spec.
Femoral Condylus Buttress Plate-I chuan a rawn ti a Femoral Condylus Buttress Plate-I chuan a rawn ti a HA 4.5
HB 6.5 a ni
RPG2KZC5HL a ni 5H L. a ni
RPG2KZC6HL a ni 6H L. a ni
RPG2KZC7HL a ni 7H L. a ni
RPG2KZC8HL a ni 8H L. a ni
RPG2KZC9HL a ni 9H L. a ni
RPG2KZC10HL a ni 10H L. a ni
RPG2KZC11HL a ni 11H L. a ni
RPG2KZC5HR a ni 5H R. a ni
RPG2KZC6HR a ni 6H R. a ni
RPG2KZC7HR a ni 7H R. a ni
RPG2KZC8HR a ni 8H R. a ni
RPG2KZC9HR a ni 9H R. a ni
RPG2KZC10HR a ni 10H R. a ni
RPG2KZC11HR a ni 11H R. a ni



XC Medico thil siam thatna

Product processing hmasa ber a ni

      CNC Preliminary Processing neih a ni


Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk.


Polishing thil siam chhuah te

           Product Polishing a ni




Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni.

Quality Inspection neih a ni

          Quality Inspection neih a ni



Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni.

Product package a ni

          Product Package a awm bawk


Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni.

Productwarehouse ah hian thil siam chhuah a ni        Product Warehouse ah a awm a


Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan.

sample room-ah dah a ni           Sample Room ah dah a ni


Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni.



XC Medico nena thawhhona tha tak neih dan tur 

1. Xc Medico Team te hnenah Femoral Condylus Buttress Plate-I Product Catalog dil rawh.


2. I duhzawng Femoral Condylus Buttress Plate-I Product thlang rawh.


3. Femoral Condylus Buttress Plate-I Test nan Sample Dil rawh.


4.XC Medico-a Femoral Condylus Buttress Plate-I chu Order siam rawh.


5.XC Medico-a Femoral Condylus Buttress Plate-I Dealer ni rawh.



XC Medico Dealer emaw Wholesaler emaw Nih A thatna

1.Femoral Condylus Buttress Plate-I lei man tha zawk.


2.100% Femoral Condylus Buttress Plate-I tha ber ber a ni.


3. Order siam tumna tlem zawk.


4. Inremna hun chhung atan Price Stability.


5. Femoral Condylus Buttress Plate-I tling tawk a ni.


6. XC Medico-a Femoral Condylus Buttress Plate-I chu rang tak leh awlsam taka tehna.


7. Khawvel pum huapa hriat hlawh Brand - XC Medico.


8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.


9. XC Medico Team ten Quality Test an tih belh.


10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.



Femoral Condylus Buttress Plate-I: A rilru a hah lutuk chuan a rilru a buai em em a

Femoral Condylus Buttress Plate-I hi orthopedic implant thiam tak a ni a, distal femoral fracture, a bik takin femoral condyles-a awmte tan stabilization tihchakna tura siam a ni. Heng ruh tliak te hi a tlangpuiin trauma emaw degenerative changes, osteoarthritis emaw osteoporosis emaw avanga lo awm a ni a, a tha taka enkawl chu a harsa thei hle. Femoral Condylus Buttress Plate-I hian orthopaedic surgeon te tan solution hmasawn tak a pe a, damlote tan damna tha ber leh functional recovery a siamsak a ni.


He kaihhruaina kimchang tak hian Femoral Condylus Buttress Plate-I atana thil pawimawh tak tak, a thatna, enkawlna hman dan, hlauhawmna leh hmalam hun atana market thlirna a chhui a, fracture management lama inhnamhnawih medical professional-te tan chipchiar takin a tarlang a ni.



tih hi eng nge ni Femoral Condylus Buttress Plate-I

Femoral Condylus Buttress Plate-I hi orthopedic device hmasawn tak a ni a, distal femoral condyle-a fracture awm thin enkawlna atana siam bik a ni. Distal femoral condyles hi femur tawp hnuai lam, khup ruh hnaihah a awm a, weight-bearing leh khup articulation mumal tak neih nan a pawimawh hle. He biala fracture hian a tichak lo thei a, a tam zawkah chuan stabilization dik tak neih theih nan surgical intervention a ngai thin.


Femoral Condylus Buttress Plate-I hi a tlangpuiin titanium emaw stainless steel chakna sang tak hmanga siam a ni a, hei hian chakna leh biocompatibility a tichiang vek a ni. Plate hian ruh tliak chu buttress emaw support emaw turin hna a thawk a, displacement a veng a, a dam tha thei bawk. Screw emaw fixation device dang emaw nen hman dun a ni a, ruh chi hrang hrangte chu alignment dik taka vawn nan hman a ni.Plate design hi fracture fixation tha ber tura siam a ni a, chutih rualin a chhehvel tissue-te tihbuai loh nan leh khup ruh biomechanical integrity vawng reng turin a siam bawk.



Femoral Condylus Buttress Plate-I ah hian a awm a

Anatomical Design hmanga siam a ni

Plate hi distal femur natural curvature nena inmil turin anatomically contoured a ni a, hei hian fit dik tak a pe a, operation neih laiin adjustment tam lutuk a ngai lo.

Buttress Function a ni

Plate 'buttress' function hian distal femoral fragments te posterior leh lateral displacement a veng thei a, healing process chhung hian enhanced stability a pe a ni.

Locking Mechanism a ni

Plate hian locking screw mechanism a hmang fo thin a, chu chuan screw te chu ruh chhungah nghet taka a awm theih nan a enkawl thin. He feature hi osteoporotic bone nei damlote tan a hlawkpui hle a, chutah chuan screw pangngai chuan fixation tha tawk lo a pe thei lo mai thei.

Screw Hole tam tak a awm

Plate hi screw hole tam tak neia design a ni a, screw dahnaah flexibility a pe a, fracture pattern hrang hrang leh anatomical variation te a awm theih nan.

Profile hniam tak design a ni

Plate design hniam tak hian soft tissue irritation a ti tlem a, hei hi a dam chak zawk nan leh operation hnua harsatna tihziaawmna atan a pawimawh hle.

Material thlan dan tur

Plate hi titanium emaw stainless steel emaw atanga siam a ni a, an pahnih hian an chakna, an chhe thei lo leh mihring taksa nena an inmil avangin hriat hlawh tak an ni.

Smooth Edges te pawh a awm

A chhehvel tissue-te irritation emaw tihchhiat emaw ven nan plate kilte chu uluk taka siam a ni a, chu chuan hliam dehiscence emaw soft tissue tihchhiat emaw ang chi harsatna a thlen theihna a ti tlem a ni.



Femoral Condylus Buttress Plate-I A thatna te chu a tha hle

Fracture Stability tihchangtlun a ni

Buttress design hian posterior leh lateral displacement a veng a, traditional plate nena khaikhin chuan stability tha zawk a pe a, hei hi malalignment emaw non-union emaw venna atan a pawimawh hle thei a ni.

Biomechanical Function tihchak a ni

Plate-a anatomical contour hian femur leh knee joint-a natural biomechanics chu a vawng reng a, hei hi post-surgical recovery leh hun rei tak chhunga hnathawh theihna atan a pawimawh hle.

Soft Tissue chhiatna tih tlem

Low-profile design hian soft tissue irritation a ti tlem a, operation hnua natna, swelling leh rehabilitation rang zawka tihziaawmna a ni.

Fracture chi hrang hrang tan Versatility a ni

Femoral Condylus Buttress Plate-I hi a hman theih a, fracture chi hrang hrang tan hman theih a ni a, chung zingah chuan complex distal femoral fracture, supracondylar region inzawm fracture, leh periprosthetic fracture te pawh a tel.

Osteoporotic Patients te zingah Outcome tha zawk a awm

Locking screw mechanism hian ruh quality tha lo (eg, osteoporotic bone) nei damlote tan stability additional a pe a, implant failure emaw screw loosening emaw a ti tlem a ni.

Infection hlauhawmna tlem ber

Plate kil hrual leh dik tak hian irritation leh infection hlauhawmna a tiziaawm a, a bik takin implant site chhehvelah a pui a ni.

Recovery chak zawk

A fixation nghet leh tissue tihbuai tlem vangin damlote chuan an dam rei zawk fo a, harsatna an nei tlem zawk a, damdawi ina rei tak awm ngai lo an awm bawk



Femoral Condylus Buttress Plate-I hmanga ruh tliak chi hrang hrang enkawl dan

Distal Femoral Fractures a awm thin

Hengte hi khup ruh bula awm fracture a ni a, a tlangpuiin high-energy trauma emaw damlo tarte tlu emaw avanga lo awm a ni. Femoral Condylus Buttress Plate-I hian ruh tliak chu a ti nghet a, khup hnathawhna a vawng reng thei a ni.

Supracondylar Fractures a awm thin

Heng ruh tliak te hi khup ruh chung lam deuhah a awm a, trauma na tak nen a inzawm fo bawk. Buttress plate hian optimal support a pe a, distal femur collapse a veng a, outcome tha zawk a siam thei bawk.

Periarticular Fractures a awm thin

Joint surface vel a fracture awm hian joint instability a thlen thei. Femoral Condylus Buttress Plate-I hian ruh chi hrang hrangte chu a inmil reng theih nan a enkawl a, hei hian ruh natna emaw, ruh natna emaw a thlen theihna a ti tlem hle.

Complex Fractures te pawh a awm

Plate hi ruh tliak hian femur hmun tam tak a awm emaw, harsatna dang, ruh hloh emaw, ruh tihchhiat (ruh inthen) emaw a awm chuan hman theih a ni.



Femoral Condylus Buttress Plate-I Surgery neih a hlauhawmna

Kaichhawng

Orthopaedic surgery dang ang bawkin, operation hnua natna kai theihna a awm a, a bik takin comorbidities emaw, immune system tihchhiat emaw nei damlote tan chuan a hlauhawm hle.

Union ni lo emaw Malunion emaw

Plate hian stability a pe a, mahse ruh chu a dam dik lo thei a, chu chuan non-union (dam lohna) emaw malunion (improper alignment) emaw a thlen thei a ni.

Implant a hlawhchham

A tlem hle nachungin, implant hi a hlawhchham thei a, a bik takin ruh quality tha lo emaw, a dam zawh hmaa implant-a stress nasa lutuk nei emaw tan chuan a hlawhchham thei a ni.

Nerve emaw Vascular Injury emaw a awm thei

Surgery neih chhung hian a bul hnaia nerve emaw thisen kalna kawng emaw a chhiat theihna a awm a, a bik takin complex fracture-ah emaw, surgeon thiam takin surgery a tih loh chuan emaw a tichhia thei a ni.

Operation hnua harsatna awm thei

Harsatna dangte chu deep vein thrombosis (DVT), thisen zam, leh hliam dam lo, a bik takin tar emaw, damlo chak lo emaw te a ni.



Femoral Condylus Buttress Plate-I hmalam hun chhinchhiahna

Mipui tar chak lutuk

Khawvel puma tar an pun zel avangin ruh tliak (fracture) a pung zel a, a bik takin ruh natna leh kum upat lam nena inzawm natna dangte nen a inzawm tlat a ni. He demographic shift hian Femoral Condylus Buttress Plate-I ang chi implant mamawhna a tipung mai thei.

Technology lama hmasawnna te

Material science lama hmasawnna kal zel, alloy rit lo, chak zawk siam chhuah te, implant design lama thil thar siam te hian Femoral Condylus Buttress Plate-I hnathawh leh himna a tipung dawn a ni.

Minimally Invasive Techniques hmanga thil tih theih a ni

Surgeon-te chuan fracture fixation atan minimally invasive approach an hmang nasa hle a, Femoral Condylus Buttress Plate-I hi heng technique te nen hian a inmil a, nakin lawkah pawh mamawh chhunzawm zel a ni.

Khawvel pum huapa Healthcare Access tihpun

Ram changkang zawka healthcare infrastructure a ṭhat chhoh zel avangin, advanced orthopedic implant mamawhna a sang chho zel dawn a, hei hian Femoral Condylus Buttress Plate-I market potential a tizau dawn a ni.



Khaihtawi

Femoral Condylus Buttress Plate-I hi distal femoral fracture enkawlna atana implant pawimawh tak a ni a, stability tha zawk a pe a, fracture chi hrang hrangah pawh damna tha ber a siam bawk. Anatomical design, locking mechanism, leh soft tissue tihbuai tlem ber avangin he plate hi surgeon leh damlo tan pawh solution rintlak tak a ni. Risk thenkhat, infection emaw implant failure emaw nena inzawm a nih laiin, Femoral Condylus Buttress Plate-I hian thatna tam tak a pe a, chung zingah chuan fracture stability tihchangtlun, dam chak zawk, leh osteoporotic patient-te tan outcome tha zawk a awm


Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.

Hma chiah: 
Dawtchiah: 

Product Category hrang hrang a awm

Khawvel pum huapa rintlak tak angin Orthopedic Implants Manufacturer , XC Medico hian damdawi lam solution tha tak tak, Trauma, Spine, Joint Reconstruction, leh Sports Medicine implants te pawh a pe chhuak nasa hle. Kum 18 chuang zet kan thiamna leh ISO 13485 certification neiin khawvel puma distributor, hospital, leh OEM/ODM partner-te hnena precision-engineered surgical instrument leh implant supply turin kan inpe a ni.

Quick Links te pawh a awm

Inbepawp

China ram Changzhou-a Changwu Middle Road-a Tianan Cyber ​​City-ah hian mipui an pungkhawm nasa hle
86- 17315089100 ah biak theih a ni

In Inbiak reng rawh

XC Medico chungchang hrechiang duh tan kan Youtube channel hi subscribe la, a nih loh leh Linkedin emaw Facebook ah min lo follow ve dawn nia. Kan information te chu kan update zel ang che.
© COPYRIGHT 2024 CHANGZHOU XC MEDICO TECHNOLOGY CO., LTD., a hlawhtlinna chu a hlawhtlinna a ni. DIKNA ENGKIM A NI.