RP2G2PR a ni
XCmedico a ni
Femur a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
Titanium Alloy hmanga siam a ni
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Thilsiam | Pic | Inherh | REF. | Spec. |
| A hnaih ber Femur Condylus Plate-II | ![]() |
HA 4.5 HB 6.5 a ni |
RP2G2PR5H a ni | 5H a ni |
| RP2G2PR6H a ni | 6H a ni | |||
| RP2G2PR7H a ni | 7H a ni | |||
| RP2G2PR8H a ni | 8H a ni | |||
| RP2G2PR9H a ni | 9H a ni | |||
| RP2G2PR10H a ni | 10H a ni | |||
| RP2G2PR12H a ni | 12H a ni | |||
| RP2G2PR14H a ni | 14H a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrang nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlak loh enfiah nan ruahman a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a awm theih nan hmun thianghlim leh sterile-ah a dah a ni. |
Orthopaedic products dahkhawmnaah hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw, shipment dik lo emaw a awm loh nan. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team te hnenah Proximal Femur Condylus Plate-II Product Catalog zawt rawh.
2. I duhzawng Proximal Femur Condylus Plate-II Product thlang rawh.
3. Proximal Femur Condylus Plate-II Test turin Sample Dil rawh.
4.XC Medico-a Proximal Femur Condylus Plate-II Order siam rawh.
5.XC Medico-a Proximal Femur Condylus Plate-II Dealer ni rawh.
1.Proximal Femur Condylus Plate-II lei man tha zawk.
2.100% A Quality sang ber Proximal Femur Condylus Plate-II.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Proximal Femur Condylus Plate-II tling tawk.
6. XC Medico-in Proximal Femur Condylus Plate-II a neih dan awlsam leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
Proximal Femur Condylus Plate-II hi advanced orthopedic implant a ni a, proximal femur-a fracture awmte fixation atana siam bik a ni a, a bik takin condylar region vel a ni. Complex fracture-ah pawh hman a ni nasa hle a, high-energy trauma case-a thleng pawh a tel a, stable fixation pek, damna tihhmasawn leh function siam that a tum a ni. He kaihhruaina kimchang takah hian Proximal Femur Condylus Plate-II nena inzawm features, advantages, treatment applications, risks, leh future trends te kan chhui dawn a, tunlai orthopaedic trauma management-a hmanraw pawimawh tak a nih chhan êng kan pe ang.
Proximal Femur Condylus Plate-II hi orthopedic implant thar tak a ni a, proximal femoral condyle-a ruh tliak te fixation atana siam a ni. He bial hi hip joint bulah a awm a, taksa rihna phurh nan leh inkalpawhna awlsam zawk nan a pawimawh hle. Proximal femoral fractures hian complex pattern hrang hrang a keng tel thei a, chung zingah chuan intertrochanteric, subtrochanteric, leh condylar fractures te pawh a tel a, hei hian an enkawl dan a ti harsa hle.
Heng ruh tliak te hi Proximal Femur Condylus Plate-II hmang hian heng ruh tliak te hi tihngheh nan hman a ni a, chu chuan ruh tliak te chu a dam chhungin a alignment tha ber a pe a ni. Plate hi a tlangpuiin titanium alloy emaw stainless steel emaw ang chi thil chak tak tak hmanga siam a ni a, hei hian a kal leh rit phurh chhuahna kawngah femur-a mechanical load lian tak tak dah chu a tuar thei tih a tichiang a ni. He implant thlah hnihna (Proximal Femur Condylus Plate-II) hian screw fixation tihchangtlun, anatomical design, leh load distribution tha zawk tihchangtlunna te a nei a, hei hian a dam chak zawk nan leh hun rei tak chhunga hnathawh thatna tur a pui a ni.
Plate hi proximal femur natural curvature nena inmil tura siam a ni a, hei hian precise fit a ti awlsam a, implant failure emaw misalignment emaw a awm theihna a ti tlem bawk.
Plate hian screw hole tam tak a nei a, hei hian screw te chu angle tha ber berah him taka dah theihna a siamsak a ni. Hei hian fracture chi hrang hrang tan fixation tha tak leh stability tha zawk a siam thei a ni.
Screw hole-a locking mechanism dah hian hun kal zelah screw a tizau thei lo va, a dam chhung zawngin a ruh chu a nghet reng thei a ni. Hei hi ruh natna (osteoporotic bone) nei damlote tan chuan a pawimawh hle.
Titanium leh stainless steel hman hian plate chu a chhe thei lo va, a chhe thei lo va, mihring tissue nen pawh a inmil thei a, allergic reaction emaw implant rejection emaw a awm thei lo.
Plate hi a hniam thei ang bera siam a ni a, soft tissue irritation leh post-operative recovery-a infection emaw discomfort ang chi complication awm theihna a tiziaawm a ni.
Proximal Femur Condylus Plate-II hian self-tapping locking screw hmangin grip leh chakna tha zawk a pe a, hei hi ruh quality tha lo emaw, osteoporotic patient-te ruh tliak emaw a nih chuan a pawimawh hle.
Plate-a anatomical design bakah hian screw fixation option tam tak a awm bawk a, hei hian ruh chi hrang hrangte chu a dam chhungin a inrem leh nghet reng a, fracture union rates a ti tha zawk a ni.
Locking screw system hian screw loosening risk nasa takin a ti tlem a, hei hian implant failure emaw secondary procedure emaw a thlen thei a ni.
Secure fixation a pek avangin plate hian natural healing process a thlawp a, non-union, malunion, emaw delayed healing hlauhawmna a ti tlem a ni.
Fracture hi simple emaw comminuted emaw pawh nise, Proximal Femur Condylus Plate-II hi fracture pattern hrang hrang tan fixation tha tak pe turin a siam danglam thei a ni.
Low-profile design hian implantation neih laiin soft tissue dissection tlem ber a siam thei a, surgical trauma a tihziaawm bakah recovery time pawh a ti tawi thei bawk.
Proximal Femur Condylus Plate-II-in a pek stability hian damlo chu a hmaa mobilization a siam thei a, hei hian rehabilitation rang zawk leh functional outcome tha zawk a thlen thei a ni.
Complex fractures a awm a, chutah chuan femur chu fragment tam takah a inthen a. Plate hian heng fragment te hi a vawn tlat theih nan a enkawl a, chu chuan ruh damna dik tak a awm theihna tur a ti sang a ni.
Femoral condyles chung lam deuhah a awm a, heng fracture te hi khup leh hip joint hnathawh dan pangngaia awm leh turin alignment dik tak a ngai fo thin. Plate hian damna tichak turin stabilization tul tak a pe a ni.
Femur trochanters lian leh te inkar a fracture a, hei hi damlo kum upa zawkah chuan tlu vang a ni. Proximal Femur Condylus Plate-II hian heng ruh tliak te hi fixation chak tak a pe a ni.
Hip replacement implants chhehvela fracture awm thin, chu chu enkawl harsa tak a ni thei. Proximal Femur Condylus Plate-II hian heng ruh tliak te hi a ti nghet thei a, ruh hnathawh a vawng reng thei bawk.
Femur trochanteric region hnuai chiaha awm fractures. Heng ruh tliak te hi a dam leh theihna tur leh a siamthat theihna turin stable fixation a ngai fo thin.
Surgery dang ang bawkin, incision site emaw, implant chhehvelah emaw natna kai theihna a awm. Sterile technique zawm leh post-operative care dik tak enkawl hian he hlauhawmna hi a tihziaawm thei a ni.
Secure fixation awm mahse, ruh chu a dam tha lo emaw, alignment dik loah emaw a dam thei a, chu chuan non-union emaw malunion emaw a thlen thei a ni.
Beisei angin a ruh tliak chu a dam lo emaw, implant chu mechanical stress nasa lutuk a nih chuan screw emaw plate emaw a chhe thei a ni.
Proximal femoral fractures hi thisen kalna kawng leh nerve lian tak takte hnaih takah a awm a, surgery hian heng structure te hi a tihchhiat theihna chance tlemte a keng tel a ni.
Surgery neih chhung hian a chhehvel taksa ruh, tendon emaw ligament emaw a chhiat theihna a awm a, chu chuan hun rei tak a dam leh thei a, hnathawh a tichhe thei bawk.
Khawvel pumah mihring an upa chho zel a, hip leh femoral fracture vei an pung zel a, hei hian Proximal Femur Condylus Plate-II ang chi orthopedic solution tha tak tak mamawhna a tipung hle.
Materials science leh surgical technique lama hmasawnna kal zel hian he implant hi a hlawk zawk leh a thar zawka siam a nih a rinawm a, biointegration tihchangtlun leh mechanical property tihchangtlun ang chi features a awm bawk ang.
Minimally invasive surgical technique a lo thang zel avangin heng procedure-a hlawhtling taka hman theih tur implant mamawhna a sang chho zel dawn a, hei vang hian Proximal Femur Condylus Plate-II hi duhthlan tur ngaihnawm tak a ni ang.
Ram thang mektea healthcare infrastructure lo thang chho zel hian Proximal Femur Condylus Plate-II ang chi ruh enkawlna hmanrua hmasawn tak takte chu nasa taka hman theihna hun remchang a siam a ni.
Proximal Femur Condylus Plate-II hi orthopedic implant pawimawh tak a ni a, proximal femur, a bik takin condylar region-a fracture awmte stabilize nan hman a ni. A thil siam chhuah hmasawn tak tak, anatomical design, locking screw system, leh biocompatible materials te hian fracture chi hrang hrang tan stability tha zawk leh healing condition tha zawk a pe a ni. A hmannaah hian hlauhawmna a awm a, chung zingah chuan infection leh implant failure te pawh a tel a, mahse surgical technique dik tak leh post-operative care hian heng risk te hi nasa takin a tihziaawm thei a ni.
Proximal Femur Condylus Plate-II hmalam hun chu a eng hle niin a lang a, hei hi mipui tar chak lutuk leh technology lama hmasawnna avanga orthopaedic implant mamawhna sang zel vang a ni. A pum puiin, Proximal Femur Condylus Plate-II hian orthopedic trauma surgery-a hmanraw pawimawh tak a entir a, femoral fracture-te tan solution rintlak leh tangkai tak a pe a, damlote hlawhtlinna tha zawkah a pui bawk.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Inbepawp