RJSG
Xcmedico
1 copë (72 orë dorëzim
Humerus
Aliazh titan ose çelik inox
CE/ISO: 9001/ISO13485.ETC
Dorëzimi i bërë me porosi 15 ditë (duke përjashtuar kohën e transportit
FedEx. Dhl.tnt.ems.etc
Disponueshmëria: | |
---|---|
Sasia: | |
Produkte | Pikturë | Modele specifike | Specifikim |
Humerus multi Bllokoj intramedullary Thonjtë |
![]() |
Rjsg18160r | 8.0 × 160r |
RJSG18160L | 8.0 × 160L | ||
Rjsg19160r | 9.0 × 160r | ||
RJSG19160L | 9.0 × 160L | ||
Rjsg17180r | 7.0 × 180 | ||
Rjsg17195r | 7.0 × 195 | ||
RJSG17210R | 7.0 × 210 | ||
Rjsg17225r | 7.0 × 225 | ||
Rjsg17240r | 7.0 × 240 | ||
Rjsg17255r | 7.0 × 255 | ||
Rjsg18180r | 8.0 × 180 | ||
Rjsg18195r | 8.0 × 195 | ||
RJSG18210R | 8.0 × 210 | ||
Rjsg18225r | 8.0 × 225 | ||
Rjsg18240r | 8.0 × 240 | ||
Rjsg18255r | 8.0 × 255 | ||
RJSG17180L | 7.0 × 180 | ||
RJSG17195L | 7.0 × 195 | ||
RJSG17210L | 7.0 × 210 | ||
RJSG17225L | 7.0 × 225 | ||
RJSG17240L | 7.0 × 240 | ||
RJSG17255L | 7.0 × 255 | ||
RJSG18180L | 8.0 × 180 | ||
RJSG18195L | 8.0 × 195 | ||
RJSG18210L | 8.0 × 210 | ||
RJSG18225L | 8.0 × 225 | ||
RJSG18240L | 8.0 × 240 | ||
RJSG18255L | 8.0 × 255 | ||
Arrë me vidë | ![]() |
Rjsg1wm0 | 0 |
Rjsg1wm2 | 2 | ||
Rjsg1wm5 | 5 | ||
Rjsg1wm10 | 10 | ||
Rjsg1wm15 | 15 | ||
Bllokimi i vidhos-i | ![]() |
Rjsg1ld4530 | 4.5 × 30 |
Rjsg1ld4532 | 4.5 × 32 | ||
Rjsg1ld4534 | 4.5 × 34 | ||
RJSG1LD4536 | 4.5 × 36 | ||
RJSG1LD4538 | 4.5 × 38 | ||
Rjsg1ld4540 | 4.5 × 40 | ||
Rjsg1ld4542 | 4.5 × 42 | ||
Rjsg1ld4544 | 4.5 × 44 | ||
RJSG1LD4546 | 4.5 × 46 | ||
Rjsg1ld4548 | 4.5 × 48 | ||
Rjsg1ld4550 | 4.5 × 50 | ||
Rjsg1ld4552 | 4.5 × 52 | ||
RJSG1LD4554 | 4.5 × 54 | ||
RJSG1LD4556 | 4.5 × 56 | ||
RJSG1LD4558 | 4.5 × 58 | ||
Rjsg1ld4560 | 4.5 × 60 | ||
Bllokimi i vidhos-II | ![]() |
Rjsg1ld3526 | 3.5 × 26 |
Rjsg1ld3528 | 3.5 × 28 | ||
Rjsg1ld3530 | 3.5 × 30 | ||
Rjsg1ld3532 | 3.5 × 32 | ||
Rjsg1ld3534 | 3.5 × 34 | ||
Rjsg1ld3536 | 3.5 × 36 | ||
Rjsg1ld3538 | 3.5 × 38 | ||
Rjsg1ld3540 | 3.5 × 40 | ||
Rjsg1ld3542 | 3.5 × 42 | ||
Rjsg1ld3544 | 3.5 × 44 | ||
RJSG1LD3546 | 3.5 × 46 | ||
Rjsg1ld3548 | 3.5 × 48 | ||
Rjsg1ld3550 | 3.5 × 50 | ||
Bllokimi i vidhos-III | ![]() |
RJSG1LD4018 | 4.0 × 18 |
RJSG1LD4020 | 4.0 × 20 | ||
Rjsg1ld4022 | 4.0 × 22 | ||
RJSG1LD4024 | 4.0 × 24 | ||
RJSG1LD4026 | 4.0 × 26 | ||
RJSG1LD4028 | 4.0 × 28 | ||
Rjsg1ld4030 | 4.0 × 30 | ||
Rjsg1ld4032 | 4.0 × 32 | ||
Rjsg1ld4034 | 4.0 × 34 | ||
RJSG1LD4036 | 4.0 × 36 | ||
RJSG1LD4038 | 4.0 × 38 | ||
Rjsg1ld4040 | 4.0 × 40 | ||
Rjsg1ld4042 | 4.0 × 42 | ||
RJSG1LD4044 | 4.0 × 44 | ||
RJSG1LD4046 | 4.0 × 46 | ||
RJSG1LD4048 | 4.0 × 48 | ||
Rjsg1ld4050 | 4.0 × 50 | ||
Rjsg1ld4052 | 4.0 × 52 | ||
RJSG1LD4054 | 4.0 × 54 | ||
RJSG1LD4056 | 4.0 × 56 | ||
RJSG1LD4058 | 4.0 × 58 | ||
RJSG1LD4060 | 4.0 × 60 |
1. Dizajni i thonjve për pikën qendrore të futjes.
|
Përpunimi paraprak i CNC Teknologjia e kontrollit numerik të kompjuterit përdoret për të përpunuar saktësisht produktet ortopedike. Ky proces ka karakteristikat e saktësisë së lartë, efikasitetit të lartë dhe përsëritshmërisë. Ai mund të prodhojë shpejt pajisje mjekësore të personalizuara që përputhen me strukturën anatomike të njeriut dhe t'u sigurojnë pacientëve plane të personalizuara të trajtimit. |
Lustrim produkti Qëllimi i lustrimit të produkteve ortopedike është të përmirësojë kontaktin midis implantit dhe indit njerëzor, të zvogëlojë përqendrimin e stresit dhe të përmirësojë qëndrueshmërinë afatgjatë të implantit. |
Inspektim cilësor Testi i vetive mekanike të produkteve ortopedike është krijuar për të simuluar kushtet e stresit të eshtrave të njeriut, për të vlerësuar aftësinë e ngarkesës dhe qëndrueshmërinë e implanteve në trupin e njeriut dhe për të siguruar sigurinë dhe besueshmërinë e tyre. |
Pako produkti Produktet ortopedike janë të paketuara në një dhomë sterile për të siguruar që produkti është i kapsuluar në një mjedis të pastër, steril për të parandaluar ndotjen mikrobike dhe për të siguruar sigurinë kirurgjikale. |
Ruajtja e produkteve ortopedike kërkon menaxhim të rreptë brenda dhe jashtë dhe kontroll të cilësisë për të siguruar gjurmueshmërinë e produktit dhe për të parandaluar skadimin ose dërgesën e gabuar. |
Dhoma e mostrës përdoret për të ruajtur, shfaqur dhe menaxhuar mostra të ndryshme të produkteve ortopedike për shkëmbimet dhe trajnimet e teknologjisë së produkteve. |
1. Pyetni ekipin XC Medico për Katalogun e Produkteve të Thonjve me shumë bllokime Humerus Intramedullary.
2. Zgjidhni produktin tuaj të interesuar me shumë bllokime Humerus Intramedullary.
3 Kërkoni një mostër për të provuar cilësinë e thonjve me shumë bllokime Humerus.
4.Përkeni një urdhër të XC Multi-Lock Humerus gozhdë intramedullary.
5. Bërja e një tregtari të gozhdës intramedullare me shumë bllokime të XC Medico.
1. Pricesmimet më të mira të blerjes së Humerus Multi-Lock Thonj Intramedullary.
2.100% Humerus me shumë bllokim me cilësi më të lartë Humerus Intramedullary.
3. Përpjekjet më pak të porositjes.
4. Stabiliteti i çmimit për periudhën e marrëveshjes.
5. Humerus i mjaftueshëm me shumë bllokime gozhdë intramedullare.
6. Vlerësimi i shpejtë dhe i lehtë i gozhdës intramedullare të XC me shumë bllokime të XC.
7. Një markë e njohur globalisht - XC Medico.
8. Koha e shpejtë e hyrjes në ekipin e shitjeve XC Medico.
9. Testi shtesë i cilësisë nga ekipi XC Medico.
10. Ndiqni porosinë tuaj XC Medico nga fillimi në fund.
Gozhda intramedullare me shumë bllokim Humerus është një implant kirurgjikal i krijuar për të stabilizuar frakturat e kockës Humerus në krahun e sipërm. Isshtë një shufër e gjatë, e hollë e bërë nga titani ose çeliku inox që futet në zgavrën medullare të humerusit. Gozhda është e siguruar në vend me vida mbyllëse që futen në kockë dhe vetë gozhdë.
Gozhda përfshin disa pika të mbylljes proksimale dhe distale që ofrojnë fiksim të sigurt. Kjo veçori lejon fleksibilitet në trajtimin e llojeve të ndryshme të frakturave, duke përfshirë fraktura tërthore, të zhdrejtë dhe të kominuar.
Me një dizajn ergonomik që lehtëson lehtësinë e futjes dhe pozicionimit, gozhda zvogëlon kohën kirurgjikale dhe mundëson përafrim të saktë me rregullime minimale.
E ndërtuar nga titani i shkallës së lartë, gozhda është e lehtë, rezistente ndaj korrozionit dhe biokompatibile, e bërë nga materiale biokompatibile që tolerohen mirë nga trupi, duke zvogëluar rrezikun e komplikimeve pas operacionit dhe duke siguruar jetëgjatësi.
Zvogëlon rrezikun e acarimit dhe infeksionit të indeve.
Sistemi shumë-bllokues siguron një stabilitet të zgjeruar, duke zvogëluar rrezikun e paqëndrueshmërisë rrotulluese dhe duke siguruar fiksim të sigurt të frakturës, veçanërisht të dobishëm në frakturat e kominuara.
Natyra e saj minimale invazive zvogëlon prishjen e indeve të buta, duke rezultuar në më pak dhimbje pas operacionit, rrezik më të ulët të infeksionit dhe shërim më të shpejtë për pacientët.
Pacientët shpesh rimarrin lëvizshmërinë më shpejt për shkak të aftësive të ndarjes së ngarkesës së gozhdës, të cilat mbështesin mbajtjen e peshës së hershme, thelbësore për zvogëlimin e komplikimeve të lidhura me imobilizimin e zgjatur.
Përputhshmëria e saj me modele të ndryshme të frakturave dhe anatomive humale e bën atë një zgjedhje të gjithanshme për kirurgët e traumës, duke siguruar nivele të larta suksesi në një sërë rastesh.
Përfshirë historinë e detajuar mjekësore, ekzaminimin fizik, ekzaminimin e imazhit (X-ray, CT, etj.) Për të vlerësuar llojin dhe shkallën e frakturës dhe gjendjen e indeve të buta përreth.
Sipas të dhënave të imazhit, është formuluar një plan i detajuar kirurgjikal, duke përfshirë zgjedhjen e qasjes, modelin e thonjve intramedullar, numrin dhe pozicionin e vidhave të mbylljes, etj.
Blloku i plexusit brachial ose anestezia e përgjithshme përdoret zakonisht.
Kjo është qasja më e përdorur, përmes prerjes në muskulin deltoid anterior, humerusi proksimal është i ekspozuar.
Për disa lloje të veçanta të frakturave, mund të kërkohen qasje të tjera, siç është qasja nënkoracoid.
Nën drejtimin e një makine me rreze X të krahut C, fragmentet e kockave të thyera reduktohen në pozicionin anatomik me manipulim ose me ndihmën e instrumenteve.
Për fraktura komplekse, ulja e hapur mund të kërkohet përmes një prerje të vogël.
Zgavra medulare gradualisht zmadhohet duke përdorur një ekspansion të zgavrës medullare për të akomoduar diametrin e thonjve intramedullary.
Nën drejtimin e makinës me rreze X të krahut C, gjilpëra udhëzuese futet në zgavrën medullare nga koka humale ose tuberoziteti më i madh deri në fundin distal të frakturës.
Vendosni gozhdën intramedullare përgjatë gjilpërës udhëzuese derisa të arrijë në pozicionin e paracaktuar.
Nën drejtimin e makinës me rreze X të krahut C, një vrimë është shpuar në kokën humerale ose tuberozitet më të madh përmes një mëngë të veçantë shpimi, dhe më pas futet një vidhos mbyllës.
Stërvitni një vrimë në skajin distal të frakturës dhe futni një vidë mbyllëse.
Përforcimi i vidhave: Numri i vidhave të mbylljes mund të rritet sipas llojit dhe stabilitetit të frakturës.
Pas hemostazës së plotë, indi i butë është shtresa e mbyllur me shtresë.
Vendosni një tub kullimi nëse është e nevojshme.
Fashë plagën me një salcë sterile.
Pas operacionit, gjymtyrët e prekura zakonisht duhet të fiksohen në një fashë trekëndore ose të përdorin një shtrëngim shpatullash.
Ushtrimet funksionale të bashkimit të shpatullave fillohen herët pas operacionit për të parandaluar ngurtësinë e nyjeve.
Për të parandaluar infeksionin, antibiotikët jepen pas operacionit.
Ndjekja e rregullt për të monitoruar shërimin e frakturës.
Edhe pse e rrallë, migrimi i thonjve mund të ndodhë nëse nuk është i bllokuar në mënyrë të sigurt, kështu që kirurgët duhet të verifikojnë që të gjitha pikat e mbylljes janë të angazhuar siç duhet gjatë operacionit.
Protokollet e duhura të sterilizimit duhet të ndiqen në mënyrë rigoroze për të parandaluar infeksionet pas operacionit, veçanërisht duke pasur parasysh natyrën minimale invazive të procedurës.
Përdorimi i forcës së kontrolluar gjatë futjes ndihmon në parandalimin e copëzimit të kockave ose zgjerimit të tepërt të kanalit, i cili mund të çojë në komplikime ose shërimin e vonuar.
NSAID dhe qetësuesit e tjerë të dhimbjes zakonisht përdoren për të menaxhuar dhimbjen pas operacionit, me terapi shtesë sipas nevojës për të siguruar rehati të pacientit.
Terapia fizike e mbikëqyrur mund të prezantohet pas 4-6 javësh për të rivendosur forcën e muskujve, fleksibilitetin dhe gamën e lëvizjes, duke ndihmuar pacientin të rimarrë funksionin normal të krahut.
Pacientët këshillohen të shikojnë për shenja të infeksionit në vendin e prerjes, të tilla si skuqje ose ënjtje, dhe të ndjekin kontrolle të rregullta.
Imazhe të rregullta kryhen për të ndjekur shërimin e kockave dhe për të siguruar që gozhda të mbetet në pozicionin e duhur, i cili është thelbësor për një rikuperim të suksesshëm.
Afati kohor për kthimin në aktivitete normale ndryshon në varësi të frakturës specifike, shkallës së shërimit individual dhe procedurës kirurgjikale. Shtë thelbësore të ndiqni këshillat e kirurgut tuaj dhe të shmangni aktivitetin e tepërt fizik gjatë fazës fillestare të shërimit. Ndërsa kocka shërohet, ju mund të rritni gradualisht nivelin e aktivitetit tuaj, duke përfshirë gamën e butë të ushtrimeve të lëvizjes dhe ushtrimet e forcimit.
Tregu i ardhshëm për Humerus Multi-Lock thonjtë intramedullary është vendosur të rritet, i nxitur nga përparimet në teknologjitë ortopedike, rritja e kërkesës për zgjidhje minimale invazive dhe zgjerimi në tregjet në zhvillim.
Thonjtë intramedullarë me shumë bllokime Humerus janë implantet kirurgjikale efektive për stabilizimin e frakturave të humerusit. Ata ofrojnë disa avantazhe, duke përfshirë invazivitetin minimal, shërimin më të shpejtë dhe rezultatet e përmirësuara funksionale. Sidoqoftë, është e rëndësishme të kuptohen rreziqet dhe komplikimet e mundshme që lidhen me këtë procedurë. Duke ndjekur teknikat e duhura kirurgjikale dhe kujdesin pas operacionit, pacientët mund të arrijnë shërimin dhe shërimin optimal.
Kujtesë e ngrohtë: Ky artikull është vetëm për referencë dhe nuk mund të zëvendësojë këshillat profesionale të mjekut. Nëse keni ndonjë pyetje, ju lutemi këshillohuni me mjekun tuaj që merr pjesë.
Produkte | Pikturë | Modele specifike | Specifikim |
Humerus multi Bllokoj intramedullary Thonjtë |
![]() |
Rjsg18160r | 8.0 × 160r |
RJSG18160L | 8.0 × 160L | ||
Rjsg19160r | 9.0 × 160r | ||
RJSG19160L | 9.0 × 160L | ||
Rjsg17180r | 7.0 × 180 | ||
Rjsg17195r | 7.0 × 195 | ||
RJSG17210R | 7.0 × 210 | ||
Rjsg17225r | 7.0 × 225 | ||
Rjsg17240r | 7.0 × 240 | ||
Rjsg17255r | 7.0 × 255 | ||
Rjsg18180r | 8.0 × 180 | ||
Rjsg18195r | 8.0 × 195 | ||
RJSG18210R | 8.0 × 210 | ||
Rjsg18225r | 8.0 × 225 | ||
Rjsg18240r | 8.0 × 240 | ||
Rjsg18255r | 8.0 × 255 | ||
RJSG17180L | 7.0 × 180 | ||
RJSG17195L | 7.0 × 195 | ||
RJSG17210L | 7.0 × 210 | ||
RJSG17225L | 7.0 × 225 | ||
RJSG17240L | 7.0 × 240 | ||
RJSG17255L | 7.0 × 255 | ||
RJSG18180L | 8.0 × 180 | ||
RJSG18195L | 8.0 × 195 | ||
RJSG18210L | 8.0 × 210 | ||
RJSG18225L | 8.0 × 225 | ||
RJSG18240L | 8.0 × 240 | ||
RJSG18255L | 8.0 × 255 | ||
Arrë me vidë | ![]() |
Rjsg1wm0 | 0 |
Rjsg1wm2 | 2 | ||
Rjsg1wm5 | 5 | ||
Rjsg1wm10 | 10 | ||
Rjsg1wm15 | 15 | ||
Bllokimi i vidhos-i | ![]() |
Rjsg1ld4530 | 4.5 × 30 |
Rjsg1ld4532 | 4.5 × 32 | ||
Rjsg1ld4534 | 4.5 × 34 | ||
RJSG1LD4536 | 4.5 × 36 | ||
RJSG1LD4538 | 4.5 × 38 | ||
Rjsg1ld4540 | 4.5 × 40 | ||
Rjsg1ld4542 | 4.5 × 42 | ||
Rjsg1ld4544 | 4.5 × 44 | ||
RJSG1LD4546 | 4.5 × 46 | ||
Rjsg1ld4548 | 4.5 × 48 | ||
Rjsg1ld4550 | 4.5 × 50 | ||
Rjsg1ld4552 | 4.5 × 52 | ||
RJSG1LD4554 | 4.5 × 54 | ||
RJSG1LD4556 | 4.5 × 56 | ||
RJSG1LD4558 | 4.5 × 58 | ||
Rjsg1ld4560 | 4.5 × 60 | ||
Bllokimi i vidhos-II | ![]() |
Rjsg1ld3526 | 3.5 × 26 |
Rjsg1ld3528 | 3.5 × 28 | ||
Rjsg1ld3530 | 3.5 × 30 | ||
Rjsg1ld3532 | 3.5 × 32 | ||
Rjsg1ld3534 | 3.5 × 34 | ||
Rjsg1ld3536 | 3.5 × 36 | ||
Rjsg1ld3538 | 3.5 × 38 | ||
Rjsg1ld3540 | 3.5 × 40 | ||
Rjsg1ld3542 | 3.5 × 42 | ||
Rjsg1ld3544 | 3.5 × 44 | ||
RJSG1LD3546 | 3.5 × 46 | ||
Rjsg1ld3548 | 3.5 × 48 | ||
Rjsg1ld3550 | 3.5 × 50 | ||
Bllokimi i vidhos-III | ![]() |
RJSG1LD4018 | 4.0 × 18 |
RJSG1LD4020 | 4.0 × 20 | ||
Rjsg1ld4022 | 4.0 × 22 | ||
RJSG1LD4024 | 4.0 × 24 | ||
RJSG1LD4026 | 4.0 × 26 | ||
RJSG1LD4028 | 4.0 × 28 | ||
Rjsg1ld4030 | 4.0 × 30 | ||
Rjsg1ld4032 | 4.0 × 32 | ||
Rjsg1ld4034 | 4.0 × 34 | ||
RJSG1LD4036 | 4.0 × 36 | ||
RJSG1LD4038 | 4.0 × 38 | ||
Rjsg1ld4040 | 4.0 × 40 | ||
Rjsg1ld4042 | 4.0 × 42 | ||
RJSG1LD4044 | 4.0 × 44 | ||
RJSG1LD4046 | 4.0 × 46 | ||
RJSG1LD4048 | 4.0 × 48 | ||
Rjsg1ld4050 | 4.0 × 50 | ||
Rjsg1ld4052 | 4.0 × 52 | ||
RJSG1LD4054 | 4.0 × 54 | ||
RJSG1LD4056 | 4.0 × 56 | ||
RJSG1LD4058 | 4.0 × 58 | ||
RJSG1LD4060 | 4.0 × 60 |
1. Dizajni i thonjve për pikën qendrore të futjes.
|
Përpunimi paraprak i CNC Teknologjia e kontrollit numerik të kompjuterit përdoret për të përpunuar saktësisht produktet ortopedike. Ky proces ka karakteristikat e saktësisë së lartë, efikasitetit të lartë dhe përsëritshmërisë. Ai mund të prodhojë shpejt pajisje mjekësore të personalizuara që përputhen me strukturën anatomike të njeriut dhe t'u sigurojnë pacientëve plane të personalizuara të trajtimit. |
Lustrim produkti Qëllimi i lustrimit të produkteve ortopedike është të përmirësojë kontaktin midis implantit dhe indit njerëzor, të zvogëlojë përqendrimin e stresit dhe të përmirësojë qëndrueshmërinë afatgjatë të implantit. |
Inspektim cilësor Testi i vetive mekanike të produkteve ortopedike është krijuar për të simuluar kushtet e stresit të eshtrave të njeriut, për të vlerësuar aftësinë e ngarkesës dhe qëndrueshmërinë e implanteve në trupin e njeriut dhe për të siguruar sigurinë dhe besueshmërinë e tyre. |
Pako produkti Produktet ortopedike janë të paketuara në një dhomë sterile për të siguruar që produkti është i kapsuluar në një mjedis të pastër, steril për të parandaluar ndotjen mikrobike dhe për të siguruar sigurinë kirurgjikale. |
Ruajtja e produkteve ortopedike kërkon menaxhim të rreptë brenda dhe jashtë dhe kontroll të cilësisë për të siguruar gjurmueshmërinë e produktit dhe për të parandaluar skadimin ose dërgesën e gabuar. |
Dhoma e mostrës përdoret për të ruajtur, shfaqur dhe menaxhuar mostra të ndryshme të produkteve ortopedike për shkëmbimet dhe trajnimet e teknologjisë së produkteve. |
1. Pyetni ekipin XC Medico për Katalogun e Produkteve të Thonjve me shumë bllokime Humerus Intramedullary.
2. Zgjidhni produktin tuaj të interesuar me shumë bllokime Humerus Intramedullary.
3 Kërkoni një mostër për të provuar cilësinë e thonjve me shumë bllokime Humerus.
4.Përkeni një urdhër të XC Multi-Lock Humerus gozhdë intramedullary.
5. Bërja e një tregtari të gozhdës intramedullare me shumë bllokime të XC Medico.
1. Pricesmimet më të mira të blerjes së Humerus Multi-Lock Thonj Intramedullary.
2.100% Humerus me shumë bllokim me cilësi më të lartë Humerus Intramedullary.
3. Përpjekjet më pak të porositjes.
4. Stabiliteti i çmimit për periudhën e marrëveshjes.
5. Humerus i mjaftueshëm me shumë bllokime gozhdë intramedullare.
6. Vlerësimi i shpejtë dhe i lehtë i gozhdës intramedullare të XC me shumë bllokime të XC.
7. Një markë e njohur globalisht - XC Medico.
8. Koha e shpejtë e hyrjes në ekipin e shitjeve XC Medico.
9. Testi shtesë i cilësisë nga ekipi XC Medico.
10. Ndiqni porosinë tuaj XC Medico nga fillimi në fund.
Gozhda intramedullare me shumë bllokim Humerus është një implant kirurgjikal i krijuar për të stabilizuar frakturat e kockës Humerus në krahun e sipërm. Isshtë një shufër e gjatë, e hollë e bërë nga titani ose çeliku inox që futet në zgavrën medullare të humerusit. Gozhda është e siguruar në vend me vida mbyllëse që futen në kockë dhe vetë gozhdë.
Gozhda përfshin disa pika të mbylljes proksimale dhe distale që ofrojnë fiksim të sigurt. Kjo veçori lejon fleksibilitet në trajtimin e llojeve të ndryshme të frakturave, duke përfshirë fraktura tërthore, të zhdrejtë dhe të kominuar.
Me një dizajn ergonomik që lehtëson lehtësinë e futjes dhe pozicionimit, gozhda zvogëlon kohën kirurgjikale dhe mundëson përafrim të saktë me rregullime minimale.
E ndërtuar nga titani i shkallës së lartë, gozhda është e lehtë, rezistente ndaj korrozionit dhe biokompatibile, e bërë nga materiale biokompatibile që tolerohen mirë nga trupi, duke zvogëluar rrezikun e komplikimeve pas operacionit dhe duke siguruar jetëgjatësi.
Zvogëlon rrezikun e acarimit dhe infeksionit të indeve.
Sistemi shumë-bllokues siguron një stabilitet të zgjeruar, duke zvogëluar rrezikun e paqëndrueshmërisë rrotulluese dhe duke siguruar fiksim të sigurt të frakturës, veçanërisht të dobishëm në frakturat e kominuara.
Natyra e saj minimale invazive zvogëlon prishjen e indeve të buta, duke rezultuar në më pak dhimbje pas operacionit, rrezik më të ulët të infeksionit dhe shërim më të shpejtë për pacientët.
Pacientët shpesh rimarrin lëvizshmërinë më shpejt për shkak të aftësive të ndarjes së ngarkesës së gozhdës, të cilat mbështesin mbajtjen e peshës së hershme, thelbësore për zvogëlimin e komplikimeve të lidhura me imobilizimin e zgjatur.
Përputhshmëria e saj me modele të ndryshme të frakturave dhe anatomive humale e bën atë një zgjedhje të gjithanshme për kirurgët e traumës, duke siguruar nivele të larta suksesi në një sërë rastesh.
Përfshirë historinë e detajuar mjekësore, ekzaminimin fizik, ekzaminimin e imazhit (X-ray, CT, etj.) Për të vlerësuar llojin dhe shkallën e frakturës dhe gjendjen e indeve të buta përreth.
Sipas të dhënave të imazhit, është formuluar një plan i detajuar kirurgjikal, duke përfshirë zgjedhjen e qasjes, modelin e thonjve intramedullar, numrin dhe pozicionin e vidhave të mbylljes, etj.
Blloku i plexusit brachial ose anestezia e përgjithshme përdoret zakonisht.
Kjo është qasja më e përdorur, përmes prerjes në muskulin deltoid anterior, humerusi proksimal është i ekspozuar.
Për disa lloje të veçanta të frakturave, mund të kërkohen qasje të tjera, siç është qasja nënkoracoid.
Nën drejtimin e një makine me rreze X të krahut C, fragmentet e kockave të thyera reduktohen në pozicionin anatomik me manipulim ose me ndihmën e instrumenteve.
Për fraktura komplekse, ulja e hapur mund të kërkohet përmes një prerje të vogël.
Zgavra medulare gradualisht zmadhohet duke përdorur një ekspansion të zgavrës medullare për të akomoduar diametrin e thonjve intramedullary.
Nën drejtimin e makinës me rreze X të krahut C, gjilpëra udhëzuese futet në zgavrën medullare nga koka humale ose tuberoziteti më i madh deri në fundin distal të frakturës.
Vendosni gozhdën intramedullare përgjatë gjilpërës udhëzuese derisa të arrijë në pozicionin e paracaktuar.
Nën drejtimin e makinës me rreze X të krahut C, një vrimë është shpuar në kokën humerale ose tuberozitet më të madh përmes një mëngë të veçantë shpimi, dhe më pas futet një vidhos mbyllës.
Stërvitni një vrimë në skajin distal të frakturës dhe futni një vidë mbyllëse.
Përforcimi i vidhave: Numri i vidhave të mbylljes mund të rritet sipas llojit dhe stabilitetit të frakturës.
Pas hemostazës së plotë, indi i butë është shtresa e mbyllur me shtresë.
Vendosni një tub kullimi nëse është e nevojshme.
Fashë plagën me një salcë sterile.
Pas operacionit, gjymtyrët e prekura zakonisht duhet të fiksohen në një fashë trekëndore ose të përdorin një shtrëngim shpatullash.
Ushtrimet funksionale të bashkimit të shpatullave fillohen herët pas operacionit për të parandaluar ngurtësinë e nyjeve.
Për të parandaluar infeksionin, antibiotikët jepen pas operacionit.
Ndjekja e rregullt për të monitoruar shërimin e frakturës.
Edhe pse e rrallë, migrimi i thonjve mund të ndodhë nëse nuk është i bllokuar në mënyrë të sigurt, kështu që kirurgët duhet të verifikojnë që të gjitha pikat e mbylljes janë të angazhuar siç duhet gjatë operacionit.
Protokollet e duhura të sterilizimit duhet të ndiqen në mënyrë rigoroze për të parandaluar infeksionet pas operacionit, veçanërisht duke pasur parasysh natyrën minimale invazive të procedurës.
Përdorimi i forcës së kontrolluar gjatë futjes ndihmon në parandalimin e copëzimit të kockave ose zgjerimit të tepërt të kanalit, i cili mund të çojë në komplikime ose shërimin e vonuar.
NSAID dhe qetësuesit e tjerë të dhimbjes zakonisht përdoren për të menaxhuar dhimbjen pas operacionit, me terapi shtesë sipas nevojës për të siguruar rehati të pacientit.
Terapia fizike e mbikëqyrur mund të prezantohet pas 4-6 javësh për të rivendosur forcën e muskujve, fleksibilitetin dhe gamën e lëvizjes, duke ndihmuar pacientin të rimarrë funksionin normal të krahut.
Pacientët këshillohen të shikojnë për shenja të infeksionit në vendin e prerjes, të tilla si skuqje ose ënjtje, dhe të ndjekin kontrolle të rregullta.
Imazhe të rregullta kryhen për të ndjekur shërimin e kockave dhe për të siguruar që gozhda të mbetet në pozicionin e duhur, i cili është thelbësor për një rikuperim të suksesshëm.
Afati kohor për kthimin në aktivitete normale ndryshon në varësi të frakturës specifike, shkallës së shërimit individual dhe procedurës kirurgjikale. Shtë thelbësore të ndiqni këshillat e kirurgut tuaj dhe të shmangni aktivitetin e tepërt fizik gjatë fazës fillestare të shërimit. Ndërsa kocka shërohet, ju mund të rritni gradualisht nivelin e aktivitetit tuaj, duke përfshirë gamën e butë të ushtrimeve të lëvizjes dhe ushtrimet e forcimit.
Tregu i ardhshëm për Humerus Multi-Lock thonjtë intramedullary është vendosur të rritet, i nxitur nga përparimet në teknologjitë ortopedike, rritja e kërkesës për zgjidhje minimale invazive dhe zgjerimi në tregjet në zhvillim.
Thonjtë intramedullarë me shumë bllokime Humerus janë implantet kirurgjikale efektive për stabilizimin e frakturave të humerusit. Ata ofrojnë disa avantazhe, duke përfshirë invazivitetin minimal, shërimin më të shpejtë dhe rezultatet e përmirësuara funksionale. Sidoqoftë, është e rëndësishme të kuptohen rreziqet dhe komplikimet e mundshme që lidhen me këtë procedurë. Duke ndjekur teknikat e duhura kirurgjikale dhe kujdesin pas operacionit, pacientët mund të arrijnë shërimin dhe shërimin optimal.
Kujtesë e ngrohtë: Ky artikull është vetëm për referencë dhe nuk mund të zëvendësojë këshillat profesionale të mjekut. Nëse keni ndonjë pyetje, ju lutemi këshillohuni me mjekun tuaj që merr pjesë.
Kontakt