RP1H
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
1.5 Maxillofacial Micro Y-Plate | RP1H624Y1 | 6 holes, 0.6mm, 24mm | |
RP1H728Y | 7 holes, 0.6mm, 28mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Maxillofacial Micro Y-Plate Product Catalog.
2. Choose Your Interested 1.5 Maxillofacial Micro Y-Plate Product.
3. Ask For A Sample To Test 1.5 Maxillofacial Micro Y-Plate.
4.Make An Order Of XC Medico's 1.5 Maxillofacial Micro Y-Plate.
5.Become A Dealer Of XC Medico's 1.5 Maxillofacial Micro Y-Plate.
1.Better Purchase Prices Of 1.5 Maxillofacial Micro Y-Plate.
2.100% The Highest Quality 1.5 Maxillofacial Micro Y-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Maxillofacial Micro Y-Plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Maxillofacial Micro Y-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 1.5 Maxillofacial Micro Y-Plate is a precision-engineered orthopedic implant designed specifically for the treatment of maxillofacial fractures. Its Y-shaped design offers exceptional stability, adaptability, and ease of use in the reconstruction of delicate facial structures. This guide provides an in-depth understanding of the 1.5 Maxillofacial Micro Y-Plate, covering its features, advantages, clinical applications, and market potential.
The 1.5 Maxillofacial Micro Y-Plate is a small titanium implant used in maxillofacial surgery to stabilize fractures in the delicate bones of the face. The "Y" shape provides multiple fixation points, ensuring secure stabilization of bone fragments. Its 1.5mm thickness allows for minimally invasive application, making it ideal for use in areas such as the mandible, zygomatic bone, and orbital rim.
The plate is specifically designed to work with 1.5mm screws, ensuring optimal fixation in both adult and pediatric cases. Its compact size and versatile design make it an indispensable tool for surgeons working to restore the structure, function, and aesthetics of the facial skeleton.
The unique Y-configuration provides three arms for fixation, offering superior stability and resistance to rotational forces. This design is particularly useful in multi-fragmentary fractures.
Made from high-grade titanium, the plate is lightweight, corrosion-resistant, and integrates seamlessly with bone, minimizing the risk of allergic reactions or implant rejection.
At just 1.5mm thick, the plate ensures minimal disruption to surrounding soft tissues, reducing postoperative discomfort and inflammation.
The plate is pre-contoured to fit the anatomical curvature of facial bones, reducing intraoperative adjustment time.
Titanium's radiolucent properties allow for clear postoperative imaging, ensuring effective monitoring of fracture healing.
The plate includes multiple screw holes strategically placed to maximize fixation strength while accommodating 1.5mm screws.
The Y-shape provides multiple fixation points, ensuring that bone fragments remain securely aligned throughout the healing process.
Its thin profile reduces the size of surgical incisions, minimizing soft tissue disruption and promoting faster recovery.
The pre-contoured design ensures a snug fit, reducing the need for extensive intraoperative modifications and allowing surgeons to achieve accurate alignment.
The plate is suitable for a wide range of fracture types, including complex and multi-fragmentary fractures, making it a highly adaptable tool.
Titanium's strength and resistance to corrosion ensure the plate maintains its structural integrity even under mechanical stress.
By restoring the natural contours of the facial skeleton, the plate helps achieve superior cosmetic results, which is critical in maxillofacial surgery.
The plate stabilizes fractures in the lower jaw, ensuring proper alignment and restoring chewing and speaking functions.
For fractures in the cheekbone area, the plate provides secure fixation, helping to restore facial symmetry and function.
In orbital fractures, the plate helps maintain the structure of the eye socket, reducing the risk of complications such as enophthalmos (sunken eye) or double vision.
Its small size and compatibility with 1.5mm screws make it ideal for use in children, where smaller and more delicate implants are required.
The Y-shaped design provides excellent stabilization for fractures involving multiple bone fragments, preventing displacement and promoting effective healing.
The plate is also used in procedures to correct congenital deformities or acquired skeletal abnormalities in the facial bones.
Like any surgical procedure, there is a risk of infection at the implant site. This can be minimized with proper aseptic techniques and postoperative care.
Rarely, excessive stress or poor fixation may lead to implant failure, necessitating revision surgery.
Although designed to minimize irritation, improper placement or excessive pressure may cause discomfort or inflammation.
In some cases, screws may loosen over time, compromising the stability of the fixation and requiring further intervention.
If the plate does not provide adequate stabilization or if bone fragments are not properly aligned, the fracture may fail to heal or heal incorrectly.
Improper placement of the plate or screws could potentially damage nearby nerves or blood vessels, leading to complications such as numbness or impaired function.
Increasing rates of road traffic accidents, sports injuries, and workplace injuries are driving demand for advanced maxillofacial fixation devices.
The growing adoption of minimally invasive techniques is increasing the use of small, versatile implants like the 1.5 Maxillofacial Micro Y-Plate.
As the population ages, the prevalence of fractures and reconstructive surgeries is expected to rise, boosting demand for durable and effective implants.
Continuous improvements in implant design and materials are enhancing the performance and accessibility of maxillofacial plates.
Improved healthcare infrastructure in emerging markets is increasing access to advanced surgical solutions, contributing to global market growth.
The 1.5 Maxillofacial Micro Y-Plate is a highly specialized implant designed to provide secure fixation for a variety of maxillofacial fractures. Its Y-shaped design, biocompatible material, and minimally invasive profile make it a preferred choice for surgeons aiming to restore both functionality and aesthetics in facial trauma cases.
While potential risks such as infection and implant failure must be carefully managed, the plate's advantages—including enhanced stability, precision fit, and versatility—make it an invaluable tool in modern maxillofacial surgery. As advancements in technology and surgical techniques continue, the 1.5 Maxillofacial Micro Y-Plate is expected to play a pivotal role in the future of facial fracture management.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
1.5 Maxillofacial Micro Y-Plate | RP1H624Y1 | 6 holes, 0.6mm, 24mm | |
RP1H728Y | 7 holes, 0.6mm, 28mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Maxillofacial Micro Y-Plate Product Catalog.
2. Choose Your Interested 1.5 Maxillofacial Micro Y-Plate Product.
3. Ask For A Sample To Test 1.5 Maxillofacial Micro Y-Plate.
4.Make An Order Of XC Medico's 1.5 Maxillofacial Micro Y-Plate.
5.Become A Dealer Of XC Medico's 1.5 Maxillofacial Micro Y-Plate.
1.Better Purchase Prices Of 1.5 Maxillofacial Micro Y-Plate.
2.100% The Highest Quality 1.5 Maxillofacial Micro Y-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Maxillofacial Micro Y-Plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Maxillofacial Micro Y-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 1.5 Maxillofacial Micro Y-Plate is a precision-engineered orthopedic implant designed specifically for the treatment of maxillofacial fractures. Its Y-shaped design offers exceptional stability, adaptability, and ease of use in the reconstruction of delicate facial structures. This guide provides an in-depth understanding of the 1.5 Maxillofacial Micro Y-Plate, covering its features, advantages, clinical applications, and market potential.
The 1.5 Maxillofacial Micro Y-Plate is a small titanium implant used in maxillofacial surgery to stabilize fractures in the delicate bones of the face. The "Y" shape provides multiple fixation points, ensuring secure stabilization of bone fragments. Its 1.5mm thickness allows for minimally invasive application, making it ideal for use in areas such as the mandible, zygomatic bone, and orbital rim.
The plate is specifically designed to work with 1.5mm screws, ensuring optimal fixation in both adult and pediatric cases. Its compact size and versatile design make it an indispensable tool for surgeons working to restore the structure, function, and aesthetics of the facial skeleton.
The unique Y-configuration provides three arms for fixation, offering superior stability and resistance to rotational forces. This design is particularly useful in multi-fragmentary fractures.
Made from high-grade titanium, the plate is lightweight, corrosion-resistant, and integrates seamlessly with bone, minimizing the risk of allergic reactions or implant rejection.
At just 1.5mm thick, the plate ensures minimal disruption to surrounding soft tissues, reducing postoperative discomfort and inflammation.
The plate is pre-contoured to fit the anatomical curvature of facial bones, reducing intraoperative adjustment time.
Titanium's radiolucent properties allow for clear postoperative imaging, ensuring effective monitoring of fracture healing.
The plate includes multiple screw holes strategically placed to maximize fixation strength while accommodating 1.5mm screws.
The Y-shape provides multiple fixation points, ensuring that bone fragments remain securely aligned throughout the healing process.
Its thin profile reduces the size of surgical incisions, minimizing soft tissue disruption and promoting faster recovery.
The pre-contoured design ensures a snug fit, reducing the need for extensive intraoperative modifications and allowing surgeons to achieve accurate alignment.
The plate is suitable for a wide range of fracture types, including complex and multi-fragmentary fractures, making it a highly adaptable tool.
Titanium's strength and resistance to corrosion ensure the plate maintains its structural integrity even under mechanical stress.
By restoring the natural contours of the facial skeleton, the plate helps achieve superior cosmetic results, which is critical in maxillofacial surgery.
The plate stabilizes fractures in the lower jaw, ensuring proper alignment and restoring chewing and speaking functions.
For fractures in the cheekbone area, the plate provides secure fixation, helping to restore facial symmetry and function.
In orbital fractures, the plate helps maintain the structure of the eye socket, reducing the risk of complications such as enophthalmos (sunken eye) or double vision.
Its small size and compatibility with 1.5mm screws make it ideal for use in children, where smaller and more delicate implants are required.
The Y-shaped design provides excellent stabilization for fractures involving multiple bone fragments, preventing displacement and promoting effective healing.
The plate is also used in procedures to correct congenital deformities or acquired skeletal abnormalities in the facial bones.
Like any surgical procedure, there is a risk of infection at the implant site. This can be minimized with proper aseptic techniques and postoperative care.
Rarely, excessive stress or poor fixation may lead to implant failure, necessitating revision surgery.
Although designed to minimize irritation, improper placement or excessive pressure may cause discomfort or inflammation.
In some cases, screws may loosen over time, compromising the stability of the fixation and requiring further intervention.
If the plate does not provide adequate stabilization or if bone fragments are not properly aligned, the fracture may fail to heal or heal incorrectly.
Improper placement of the plate or screws could potentially damage nearby nerves or blood vessels, leading to complications such as numbness or impaired function.
Increasing rates of road traffic accidents, sports injuries, and workplace injuries are driving demand for advanced maxillofacial fixation devices.
The growing adoption of minimally invasive techniques is increasing the use of small, versatile implants like the 1.5 Maxillofacial Micro Y-Plate.
As the population ages, the prevalence of fractures and reconstructive surgeries is expected to rise, boosting demand for durable and effective implants.
Continuous improvements in implant design and materials are enhancing the performance and accessibility of maxillofacial plates.
Improved healthcare infrastructure in emerging markets is increasing access to advanced surgical solutions, contributing to global market growth.
The 1.5 Maxillofacial Micro Y-Plate is a highly specialized implant designed to provide secure fixation for a variety of maxillofacial fractures. Its Y-shaped design, biocompatible material, and minimally invasive profile make it a preferred choice for surgeons aiming to restore both functionality and aesthetics in facial trauma cases.
While potential risks such as infection and implant failure must be carefully managed, the plate's advantages—including enhanced stability, precision fit, and versatility—make it an invaluable tool in modern maxillofacial surgery. As advancements in technology and surgical techniques continue, the 1.5 Maxillofacial Micro Y-Plate is expected to play a pivotal role in the future of facial fracture management.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.