RPG2PR a ni
XCmedico a ni
Femur a ni
1 Pcs(Darkar 72 chhung a rawn thawn)
A rilru a hah lutuk chuan a rilru a buai em em a. CE/ISO:9001/ISO13485.Etc
Titanium Alloy hmanga siam a ni
Custom-Made Ni 15 chhung Delivery(Shipping Hun tel lovin)
FedEx chuan a rawn ti a. DHL.TNT.EMS.Etc
| A awm theih dan: | |
|---|---|
| Zat: | |
| Thilsiam | Pic | Inherh | REF. | Spec. |
| A hnaih ber Femur Condylus Plate a awm | ![]() |
HA 4.5 HB 6.5 a ni |
RPG2PR5H a ni | 5H a ni |
| RPG2PR6H a ni | 6H a ni | |||
| RPG2PR7H a ni | 7H a ni | |||
| RPG2PR8H a ni | 8H a ni | |||
| RPG2PR9H a ni | 9H a ni | |||
| RPG2PR10H a ni | 10H a ni | |||
| RPG2PR12H a ni | 12H a ni | |||
| RPG2PR14H a ni | 14H a ni |
CNC Preliminary Processing neih a ni Computer numerical control technology hmang hian orthopaedic products te chu chiang takin an process thei a ni. Hetiang kalphung hian precision sang tak, efficiency sang tak, leh repeatability sang tak a nei a. Mihring taksa peng hrang hrangte nena inmil, damdawi hmanrua siam chhuah rang takin a siam thei a, damlote tan pawh mimal enkawlna ruahmanna a pe thei bawk. |
Product Polishing a ni Orthopaedic products polishing hian a tum ber chu implant leh mihring tissue inzawmna siam that a, stress concentration tihziaawm a, implant hun rei tak chhunga a stability tihchangtlun a ni. |
Quality Inspection neih a ni Orthopaedic products-a mechanical properties test hi mihring ruhte stress condition simulate nan siam a ni a, mihring taksaa implant-te load-bearing capacity leh durability endik a, an him leh rintlakzia enfiah a ni. |
Product Package a awm bawk Orthopaedic products hi sterile room-ah dah a ni a, hei hian microbial contamination ven nan leh surgical safety a nih theih nan product chu sterile environment thianghlim leh sterile-ah encapsulated a nih theih nan a pui a ni. |
Orthopaedic products dahkhawmna atan hian in-and-out management leh quality control khauh tak a ngai a, hei hian product traceability a neih theih nan leh expiration emaw shipment dik lo emaw a veng thei a ni. |
Sample room hi product technology exchange leh training atan orthopaedic product hrang hrang sample dahkhawmna, phochhuahna leh enkawl nan hman a ni. |
1. Xc Medico Team te hnenah Proximal Femur Condylus Plate Product Catalog zawt rawh.
2. I duhzawng Proximal Femur Condylus Plate Product thlang rawh.
3. Proximal Femur Condylus Plate Test turin Sample Dil rawh.
4.XC Medico-a Proximal Femur Condylus Plate Order siam rawh.
5.XC Medico-a Proximal Femur Condylus Plate Dealer ni rawh.
1.Proximal Femur Condylus Plate lei man tha zawk.
2.100% Proximal Femur Condylus Plate Quality sang ber a ni.
3. Order siam tumna tlem zawk.
4. Inremna hun chhung atan Price Stability.
5. Proximal Femur Condylus Plate tling tawk.
6. XC Medico-in Proximal Femur Condylus Plate a siam dan awlsam leh awlsam taka tehna.
7. Khawvel pum huapa hriat hlawh Brand - XC Medico.
8. XC Medico Sales Team tan Fast Access Hun hman theih a ni.
9. XC Medico Team ten Quality Test an tih belh.
10. I XC Medico Order kha a tir atanga a tawp thlengin track rawh.
Proximal Femur Condylus Plate hi orthopedic implant specialized tak a ni a, proximal femur, a bik takin condylar region-a fracture leh deformities enkawlna atana hman thin a ni. He implant hian hip joint bula fracture awmte enkawlna kawngah hmun pawimawh tak a chang a, ruh taksa peng hrang hrang leh ruh hnathawh humhalh a ngaih avangin enkawl a harsa fo thin. He kaihhruaina kimchang takah hian Proximal Femur Condylus Plate nena inzawm thil pawimawh tak takte, a thatna te, fracture enkawlna hman dan te, a hlauhawmna te, leh nakin lawka market trend te kan chhui dawn a ni.
Proximal Femur Condylus Plate hi orthopedic implant chi khat a ni a, a bik takin femur-a proximal condylar region-a fracture awmte chu internal fixation pe turin siam a ni. Femur hi taksaa ruh lian ber leh chak ber zinga mi a nih avangin rit phurh leh kal theihna kawngah hmun pawimawh tak a chang a ni. Proximal femur hi hip joint bula awm a ni a, chutah chuan femoral head, neck leh condyles te a tel a ni. He hmuna ruh tliak a awm hian ruh chi hrang hrang (complex bone fragments), a hmun dang (displaced structures) leh ruh inzawmna (joint instability) a awm fo thin.
He implant hi a tlangpuiin titanium emaw stainless steel emaw ang chi thil chhe thei lo, biocompatible hmanga siam a ni a, chu chuan ruh damna dik tak neih theihna tura chakna, nghet leh dam rei theihna a tichiang a ni. Condylus plate hi femur proximal end anatomical shape-a contour turin siam a ni a, chu chuan plate chu ruh-a anchor tu screw hmangin secure fixation a pe a ni. Comprehensive stabilization atan hmanraw dang intramedullary nail emaw hip screw emaw nen hman dun a ni fo thin.
Plate hi proximal femur anatomical curve nena inmil turin a bik takin siam a ni a, hei hian precise fit leh optimal stabilization a tichiang a ni.
Plate-ah hian screw holes strategically placed a awm a, hei hian surgeon-te chuan screw-te chu fixation tha zawk neih theih nan angle tha ber berah an dah thei a ni. Screw holes hian cortical leh cancellous bone screw pahnih a siam thei a, chu chu a ruh tliak chi leh ruh density a zirin a ni.
Proximal Femur Condylus Plate design thenkhatah chuan screw fixation atan locking mechanism a awm a, hei hian hun kal zelah screw a lo chhuah loh nan stability a pe belh a, a bik takin osteoporotic bone-ah chuan.
Titanium alloy ang chi thil chakna sang tak hmanga siam niin, plate hi a chhe thei lo a, implant tihchhiat theihna a ti tlem a, hun rei tak chhung a daih thei bawk.
Implant hi a low-profile thei ang bera siam a ni a, a chhehvel soft tissue-a irritation tih tlem bakah hliam natna emaw, nuam lo emaw ang chi complication awm theihna a ti tlem bawk.
Plate hi fracture chi hrang hrang atan hman theih a ni a, simple atanga comminuted fracture thlengin, fixation device dang nen pawh hman theih a ni a, a bik takin complex case-ah chuan stability tihchangtlun theih a ni bawk.
Anatomical design leh multiple screw holes te hian fracture alignment dik tak leh stable fixation a siam thei a, hei hi damna tha tak neih nan a pawimawh hle.
Design hniam tak leh corrosion-resistant materials te hian soft tissue irritation, infection leh implant failure te a ti tlem a ni. Hei hian hun rei tak chhunga result tha zawk a awm theih nan a pui thin.
Plate hi secure fixation a nih avangin ruhte chu a awmna tur dik takah dah a ni a, hei hian a dam chak zawk a, non-union emaw malunion emaw a thlen theihna a ti tlem bawk.
Fracture chu simple emaw comminuted emaw pawh nise, plate chu stabilization chak tak pe turin a insiamrem thei a ni. Tin, a versatile tawk bawk a, a bik takin complex fracture atan fixation device dang nen pawh hman theih a ni.
Anatomical design hian surgical procedure invasive lo zawk a siam thei a, hei hian soft tissue chhiatna a ti tlem a, post-operative recovery time a ti tha bawk.
Fixation nghet tak a pek avangin Proximal Femur Condylus Plate hian damlote chu enkawlna kawng nghet lo zawk nena khaikhin chuan damlote chu an hnathawh leh an kal theihna tur a siam rang zawk a ni.
Heng ruh tliak te hi femoral condyles chung lam deuhah a awm a, tlu emaw motor accident emaw ang chi trauma vang a ni fo thin. Plate hian heng fracture chi hrang hrangte tan hian stabilization tha tak a pe a ni.
Femur hi a chi hrang hranga a inthen chuan stabilization hi a harsa thei hle. Proximal Femur Condylus Plate-a screw hole tam tak leh anatomical fit te hian heng complex fracture te tan hian fixation tul tak tak a thlen theih nan a pui a ni.
Heng fracture te hian joint surface a huam a, joint alignment a awm reng theih nan uluk taka enkawl a ngai a ni. Plate hian joint congruency siam that nan reduction leh fixation dik tak a enkawl a ni.
Femur chu dislocation nena inzawm a fracture a nih chuan Proximal Femur Condylus Plate hian ruh leh ruh pahnih a ti nghet thei a, prognosis pumpui a ti tha hle.
Osteoporosis emaw metastatic bone disease ang chi underlying conditions avanga fracture lo awm tan chuan Proximal Femur Condylus Plate hian osteoporotic emaw weaked bones-a a tul thei tur stabilization chak tak a pe a ni.
Surgery dang ang bawkin, incision site emaw, implant chhehvelah emaw natna kai theihna a awm. Hetiang hlauhawmna tihziaawmna atan hian sterile technique dik tak leh post-operative care a pawimawh hle.
Secure fixation awm mahse, fracture te chu a dam tha thei lo (non-union) emaw, alignment dik lo (malunion) ah a dam thei a, chu chuan hnathawh a tichhe thei a, surgery dang neih belh a ngai thei bawk.
Screw emaw plate emaw chu a lo chhuak thei a, a chhe thei bawk a, a bik takin ruh chu beisei angin a dam loh emaw, plate chu a stress lutuk emaw a nih chuan.
He biala femoral artery leh nerve te hnaih lutuk hian operation neih laiin hliam a thlen theihna a tipung a, a bik takin plate chu a awmna tur dik taka dah a nih loh chuan a tipung a ni.
Surgery neih chhung hian a chhehvel taksa ruh, ligament emaw, tendon emaw a chhiat thei a, chu chuan hun rei tak a dam leh thei a, hnathawh a tichhe thei bawk.
A tlem hle nachungin, taksain implant a hnawl theihna chance tlemte a awm a, a bik takin damloin metals a sensitivity a neih emaw, infection a set in emaw a nih chuan.
Khawvel pumah mihring an upa chho zel a, hip leh femur fracture hi a pung zel tura ngaih a ni a, a bik takin kum upa lam zingah chuan orthopaedic implant mamawhna a sang chho zel a ni.
Biomaterials chungchanga zirchianna kalpui mek, bioresorbable implants leh advanced titanium alloy te hian Proximal Femur Condylus Plate version thar zawk siam a nih a rinawm a, hei hian healing rates a tichangtlung a, complications a ti tlem bawk.
Minimally invasive surgery technique te chu a lar chho zel a, chutiang tih awlsamna tur implant, low-profile Proximal Femur Condylus Plate ang chi chu a pawimawh zual zel dawn a ni.
Ram thang mektea healthcare infrastructure tihpun hian orthopedic solution hmasawn tak tak mamawhna a tipung dawn a, hei hian Proximal Femur Condylus Plate market a tipung dawn a ni.
Proximal Femur Condylus Plate hi orthopedic implant tha tak a ni a, femoral condylar region-a fracture awmte chinfelna atana siam a ni. A anatomical design, a durability leh versatility te hian proximal femur complex fracture enkawlna atan duhthlanna tha ber a ni. A hmannaah hian hlauhawmna a awm a, chung zingah chuan infection leh hardware chhiat te pawh a tel a, mahse uluk taka surgical technique leh post-operative care hian heng harsatnate hi a tiziaawm thei a ni. He implant nakin lawka market hi a nghet hle a, hei hi material lama hmasawnna te, khawvel pum huapa mihring upa tawh lutuk te, leh minimally invasive surgical technique hman chhunzawm zel vang te a ni.
A pum puiin, Proximal Femur Condylus Plate hi orthopaedic surgeon-te tan hmanraw pawimawh tak a la ni reng a, femoral fracture nei damlote tan stabilization rintlak leh tangkai tak a pe a, dam chak zawk leh hun rei tak chhunga result tha zawk siamna kawngah a pui bawk.
Warm reminder: He thuziak hi reference atan chauh a ni a, doctor-in professional advice a thlak thei lo. Zawhna i neih chuan i attending physician rawn zawt rawh.
Quality, delivery leh after-sales support huamtu venhimna thuthlung kimchang zawng chhuak rawh.
Tunah hian Support hmu rawhcontent a hring vek!
Inbepawp