J007
Xcmedico
1 pcs (72 jam pengiriman)
Paduan Titanium
CE/ISO: 9001/ISO13485.ETC
Pengiriman 15 hari yang dibuat khusus (Tidak termasuk waktu pengiriman)
Fedex. Dhl.tnt.ems.etc
Tersedianya: | |
---|---|
Kuantitas: | |
Xn-ps femoral condylar | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5210-01011 | 1L# | Lebar 57.5mm | Cocrmo | |
5210-01012 | 1R# | Lebar 57.5mm | ||
5210-01021 | 2L# | Lebar 60.5mm | ||
5210-01022 | 2R# | Lebar 60.5mm | ||
5210-01031 | 3L# | Lebar 63mm | ||
5210-01032 | 3R# | Lebar 63mm | ||
5210-01041 | 4L# | Lebar 65mm | ||
5210-01042 | 4r# | Lebar 65mm | ||
5210-01051 | 5L# | Lebar 67.5mm | ||
5210-01052 | 5R# | Lebar 67.5mm | ||
5210-01061 | 6L# | Lebar 70.5mm | ||
5210-01062 | 6r# | Lebar 70.5mm | ||
5210-01071 | 7L# | lebar 75mm | ||
5210-01072 | 7r# | lebar 75mm | ||
5210-01081 | 8L# | Lebar 78.5mm | ||
5210-01082 | 8r# | Lebar 78.5mm | ||
Condylar femoralis Xn-cr | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5214-01011 | 1L# | Lebar 57.5mm | Cocrmo | |
5214-01012 | 1R# | Lebar 57.5mm | ||
5214-01021 | 2L# | Lebar 60.5mm | ||
5214-01022 | 2R# | Lebar 60.5mm | ||
5214-01031 | 3L# | Lebar 63mm | ||
5214-01032 | 3R# | Lebar 63mm | ||
5214-01041 | 4L# | Lebar 65mm | ||
5214-01042 | 4r# | Lebar 65mm | ||
5214-01051 | 5L# | Lebar 67.5mm | ||
5214-01052 | 5R# | Lebar 67.5mm | ||
5214-01061 | 6L# | Lebar 70.5mm | ||
5214-01062 | 6r# | Lebar 70.5mm | ||
5214-01071 | 7L# | lebar 75mm | ||
5214-01072 | 7r# | lebar 75mm | ||
5214-01081 | 8L# | Lebar 78.5mm | ||
5214-01082 | 8r# | Lebar 78.5mm | ||
Sisipan XN-PS | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5217-10011 | 1# | 10mm | Uhmwpe | |
5217-12011 | 12mm | |||
5217-14011 | 14mm | |||
5217-16011 | 16mm | |||
5217-18011 | 18mm | |||
5217-10021 | 2#/3#/4# | 10mm | ||
5217-12021 | 12mm | |||
5217-14021 | 14mm | |||
5217-16021 | 16mm | |||
5217-18021 | 18mm | |||
5217-10031 | 5#/6# | 10mm | ||
5217-12031 | 12mm | |||
5217-14031 | 14mm | |||
5217-16031 | 16mm | |||
5217-18031 | 18mm | |||
5217-10041 | 7#/8# | 10mm | ||
5217-12041 | 12mm | |||
5217-14041 | 14mm | |||
5217-16041 | 16mm | |||
5217-18041 | 18mm | |||
Xn-PS Sisipkan (ve) | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5217-10011 | 1# | 10mm | Vitamin E sangat crosslink | |
5217-12011 | 12mm | |||
5217-14011 | 14mm | |||
5217-16011 | 16mm | |||
5217-18011 | 18mm | |||
5217-10021 | 2#/3#/4# | 10mm | ||
5217-12021 | 12mm | |||
5217-14021 | 14mm | |||
5217-16021 | 16mm | |||
5217-18021 | 18mm | |||
5217-10031 | 5#/6# | 10mm | ||
5217-12031 | 12mm | |||
5217-14031 | 14mm | |||
5217-16031 | 16mm | |||
5217-18031 | 18mm | |||
5217-10041 | 7#/8# | 10mm | ||
5217-12041 | 12mm | |||
5217-14041 | 14mm | |||
5217-16041 | 16mm | |||
5217-18041 | 18mm | |||
Insert xn-cr | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5218-10011 | 1# | 10mm | Uhmwpe | |
5218-12011 | 12mm | |||
5218-14011 | 14mm | |||
5218-16011 | 16mm | |||
5218-18011 | 18mm | |||
5218-10021 | 2#/3#/4# | 10mm | ||
5218-12021 | 12mm | |||
5218-14021 | 14mm | |||
5218-16021 | 16mm | |||
5218-18021 | 18mm | |||
5218-10031 | 5#/6# | 10mm | ||
5218-12031 | 12mm | |||
5218-14031 | 14mm | |||
5218-16031 | 16mm | |||
5218-18031 | 18mm | |||
5218-10041 | 7#/8# | 10mm | ||
5218-12041 | 12mm | |||
5218-14041 | 14mm | |||
5218-16041 | 16mm | |||
5218-18041 | 18mm | |||
Insert xn-cr | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5218-10012 | 1# | 10mm | Vitamin E tinggi silang uhmwpe | |
5218-12012 | 12mm | |||
5218-14012 | 14mm | |||
5218-16012 | 16mm | |||
5218-18012 | 18mm | |||
5218-10022 | 2#/3#/4# | 10mm | ||
5218-12022 | 12mm | |||
5218-14022 | 14mm | |||
5218-16022 | 16mm | |||
5218-18022 | 18mm | |||
5218-10032 | 5#/6# | 10mm | ||
5218-12032 | 12mm | |||
5218-14032 | 14mm | |||
5218-16032 | 16mm | |||
5218-18032 | 18mm | |||
5218-10042 | 7#/8# | 10mm | ||
5218-12042 | 12mm | |||
5218-14042 | 14mm | |||
5218-16042 | 16mm | |||
5218-18042 | 18mm | |||
Xn-ps/cr nampan tibialis universal | ||||
Kode | Ukuran | Bahan | ![]() | |
5216-01010 | Baki Tibial 1# | Cocrmo | ||
5216-01020 | Baki Tibial 2# | |||
5216-01030 | Baki Tibial 3# | |||
5216-01040 | Baki Tibial 4# | |||
5216-01050 | Baki Tibial 5# | |||
5216-01060 | Baki Tibial 6# | |||
5216-01070 | Baki Tibial 7# | |||
5216-01080 | Baki Tibial 8# | |||
XN Patellar | ||||
Kode | Ketebalan | Diameter | Bahan | ![]() |
5213-08260 | 8mm | 26mm | Uhmwpe | |
5213-08280 | 28mm | |||
5213-08300 | 30mm | |||
5213-08320 | 32mm | |||
5213-10260 | 10mm | 26mm | ||
5213-10280 | 28mm | |||
5213-10300 | 30mm | |||
5213-10320 | 32mm | |||
5213-12260 | 12mm | 26mm | ||
5213-12280 | 28mm | |||
5213-12300 | 30mm | |||
5213-12320 | 32mm | |||
XM-PS Femoral Condylar | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5110-03021 | 2L# | Lebar 57mm | Cocrmo | |
5110-03022 | 2R# | Lebar 57mm | ||
5110-03031 | 3L# | lebar 60mm | ||
5110-03032 | 3R# | lebar 60mm | ||
5110-03041 | 4L# | lebar 62mm | ||
5110-03042 | 4r# | lebar 62mm | ||
5110-03051 | 5L# | Lebar 65mm | ||
5110-03052 | 5R# | Lebar 65mm | ||
5110-03061 | 6L# | Lebar 67mm | ||
5110-03062 | 6r# | Lebar 67mm | ||
5110-03071 | 7L# | lebar 70mm | ||
5110-03072 | 7r# | lebar 70mm | ||
5110-03081 | 8L# | lebar 72mm | ||
5110-03082 | 8r# | lebar 72mm | ||
5110-03101 | 10L# | lebar 77mm | ||
5110-03102 | 10R# | lebar 77mm | ||
XM-PS Femoral Condylar | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5114-03011 | 2L# | Lebar 57mm | Cocrmo | |
5114-03012 | 2R# | Lebar 57mm | ||
5114-03021 | 3L# | lebar 60mm | ||
5114-03022 | 3R# | lebar 60mm | ||
5114-03031 | 4L# | lebar 62mm | ||
5114-03032 | 4r# | lebar 62mm | ||
5114-03041 | 5L# | Lebar 65mm | ||
5114-03042 | 5R# | Lebar 65mm | ||
5114-03051 | 6L# | Lebar 67mm | ||
5114-03052 | 6r# | Lebar 67mm | ||
5114-03061 | 7L# | lebar 70mm | ||
5114-03062 | 7r# | lebar 70mm | ||
5114-03071 | 8L# | lebar 72mm | ||
5114-03072 | 8r# | lebar 72mm | ||
5114-03091 | 10L# | lebar 77mm | ||
5114-03092 | 10R# | lebar 77mm | ||
Sisipan XM-PS | ||||
Kode | Ukuran | Ketebalan/lebar | Bahan | ![]() |
5112-09021 | 2# | 9mm/62mm | UHMWPE / HXLPE / VE-HXL | |
5112-11021 | 11mm/62mm | |||
5112-13021 | 13mm/62mm | |||
5112-15021 | 15mm/62mm | |||
5112-17021 | 17mm/62mm | |||
5112-19021 | 19mm/62mm | |||
5112-09041 | 3/4# | 9mm/67mm | ||
5112-11041 | 11mm/67mm | |||
5112-13041 | 13mm/67mm | |||
5112-15041 | 15mm/67mm | |||
5112-17041 | 17mm/67mm | |||
5112-19041 | 19mm/67mm | |||
5112-09061 | 5/6# | 9mm/72mm | ||
5112-11061 | 11mm/72mm | |||
5112-13061 | 13mm/72mm | |||
5112-15061 | 15mm/72mm | |||
5112-17061 | 17mm/72mm | |||
5112-19061 | 19mm/72mm | |||
5112-09081 | 7/8# | 9mm/77mm | ||
5112-11081 | 11mm/77mm | |||
5112-13081 | 13mm/77mm | |||
5112-15081 | 15mm/77mm | |||
5112-17081 | 17mm/77mm | |||
5112-19081 | 19mm/77mm | |||
5112-09101 | 10# | 9mm/82mm | ||
5112-11101 | 11mm/82mm | |||
5112-13101 | 13mm/82mm | |||
5112-15101 | 15mm/82mm | |||
5112-17101 | 17mm/82mm | |||
5112-19101 | 19mm/82mm | |||
Insert xm-cr | ||||
Kode | Ukuran | Ketebalan/lebar | Bahan | ![]() |
5115-09011 | 2# | 9mm/62mm | UHMWPE / HXLPE / VE-HXL | |
5115-11011 | 11mm/62mm | |||
5115-13011 | 13mm/62mm | |||
5115-15011 | 15mm/62mm | |||
5115-17011 | 17mm/62mm | |||
5115-19011 | 19mm/62mm | |||
5115-09031 | 3/4# | 9mm/67mm | ||
5115-11031 | 11mm/67mm | |||
5115-13031 | 13mm/67mm | |||
5115-15031 | 15mm/67mm | |||
5115-17031 | 17mm/67mm | |||
5115-19031 | 19mm/67mm | |||
5115-09051 | 5/6# | 9mm/72mm | ||
5115-11051 | 11mm/72mm | |||
5115-13051 | 13mm/72mm | |||
5115-15051 | 15mm/72mm | |||
5115-17051 | 17mm/72mm | |||
5115-19051 | 19mm/72mm | |||
5115-09071 | 7/8# | 9mm/77mm | ||
5115-11071 | 11mm/77mm | |||
5115-13071 | 13mm/77mm | |||
5115-15071 | 15mm/77mm | |||
5115-17071 | 17mm/77mm | |||
5115-19071 | 19mm/77mm | |||
5115-09091 | 10# | 9mm/82mm | ||
5115-11091 | 11mm/82mm | |||
5115-13091 | 13mm/82mm | |||
5115-15091 | 15mm/82mm | |||
5115-17091 | 17mm/82mm | |||
5115-19091 | 19mm/82mm | |||
XM Tibia Tray Cr & PS Baki Tibial (Cljmc) | ||||
Kode | Ukuran | Bahan | ![]() | |
5111-01020 | 2#, 62mm | Cocrmo | ||
5111-01030 | 3#, 65mm | |||
5111-01040 | 4#, 67mm | |||
5111-01050 | 5#, 70mm | |||
5111-01060 | 6#, 71mm | |||
5111-01070 | 7#, 75mm | |||
5111-01080 | 8#, 76mm | |||
5111-01100 | 10#, 82mm | |||
XM Patellar | ||||
Kode | Ketebalan | Diameter | Bahan | ![]() |
5214-08260 | 8mm | 26mm | UHMWPE / HXLPE / VE-HXL | |
5214-08290 | 29mm | |||
5214-08320 | 32mm | |||
5214-08350 | 35mm | |||
5214-10260 | 10mm | 26mm | ||
5214-10290 | 29mm | |||
5214-10320 | 32mm | |||
5214-10350 | 35mm | |||
5214-12260 | 12mm | 26mm | ||
5214-12290 | 29mm | |||
5214-12320 | 32mm | |||
5214-12350 | 35mm |
Pemrosesan pendahuluan CNC Teknologi kontrol numerik komputer digunakan untuk memproses produk ortopedi secara tepat. Proses ini memiliki karakteristik presisi tinggi, efisiensi tinggi, dan pengulangan. Ini dapat dengan cepat menghasilkan perangkat medis khusus yang sesuai dengan struktur anatomi manusia dan memberikan pasien dengan rencana perawatan yang dipersonalisasi. | Pemolesan produk Tujuan pemolesan produk ortopedi adalah untuk meningkatkan kontak antara implan dan jaringan manusia, mengurangi konsentrasi stres, dan meningkatkan stabilitas jangka panjang implan. | Inspeksi Kualitas Uji sifat mekanik produk ortopedi dirancang untuk mensimulasikan kondisi stres tulang manusia, mengevaluasi kapasitas penahan beban dan daya tahan implan dalam tubuh manusia, dan memastikan keamanan dan keandalannya. |
Paket produk Produk ortopedi dikemas di ruang steril untuk memastikan bahwa produk dienkapsulasi dalam lingkungan yang bersih dan steril untuk mencegah kontaminasi mikroba dan memastikan keamanan bedah. |
Penyimpanan produk ortopedi membutuhkan manajemen masuk-dan-keluar yang ketat dan kontrol kualitas untuk memastikan keterlacakan produk dan mencegah kedaluwarsa atau pengiriman yang salah. |
Ruang sampel digunakan untuk menyimpan, menampilkan, dan mengelola berbagai sampel produk ortopedi untuk pertukaran dan pelatihan teknologi produk. |
1. Minta tim XC Medico untuk katalog produk lutut total utama.
2. Pilih produk lutut total utama Anda yang tertarik.
3. Minta sampel untuk menguji total lutut primer.
4. Buat pesanan lutut total utama XC Medico.
5. Berdasarkan dealer lutut total utama XC Medico.
1. Harga pembelian lebih baik dari total lutut primer.
2,100% Lutut total primer berkualitas tinggi.
3. Upaya pemesanan yang lebih sedikit.
4. Stabilitas harga untuk periode perjanjian.
5. Lutut total primer yang cukup.
6. Penilaian cepat dan mudah dari lutut total utama XC Medico.
7. Merek yang diakui secara global - XC Medico.
8. Waktu akses cepat ke tim penjualan XC Medico.
9. Tes kualitas tambahan oleh tim XC Medico.
10. Lacak pesanan XC Medico Anda dari awal hingga akhir.
Operasi penggantian lutut telah menjadi landasan perawatan ortopedi, secara signifikan meningkatkan mobilitas dan kualitas hidup bagi jutaan pasien. Penggantian lutut total primer (TKR) adalah prosedur yang dilakukan secara luas yang dirancang untuk mengatasi kerusakan sendi lutut yang parah yang disebabkan oleh radang sendi, trauma, atau kondisi degeneratif. Panduan ini menyediakan eksplorasi mendalam dari penggantian lutut total primer, termasuk fitur, keunggulan, aplikasi, risiko, dan tren pasar di masa depan.
Penggantian lutut total primer mengacu pada prosedur bedah awal yang dilakukan untuk menggantikan sendi lutut yang rusak dengan implan prostetik. Prosedur ini umumnya diindikasikan untuk pasien yang menderita nyeri yang melemahkan dan keterbatasan fungsional karena kondisi seperti osteoartritis, rheumatoid arthritis, atau arthritis pasca-trauma. Tujuan utama adalah untuk mengembalikan fungsi sendi, mengurangi rasa sakit, dan meningkatkan mobilitas keseluruhan, memungkinkan pasien untuk kembali ke aktivitas sehari -hari.
Biasanya terdiri dari komponen femoral, tibial, dan patellar untuk fleksibilitas dan kustomisasi.
Implan terbuat dari bahan biokompatibel seperti paduan kobalt-kromium, titanium, atau polietilen untuk memastikan umur panjang dan meminimalkan keausan.
Dirancang untuk meniru gerakan alami lutut, mengurangi gesekan dan memastikan mobilitas yang halus.
Disesuaikan dengan kebutuhan masing -masing pasien, dengan bantalan seluler memberikan peningkatan fleksibilitas dan stabilitas.
Implan yang lebih baru memfasilitasi teknik bedah invasif minimal, mengurangi gangguan jaringan lunak.
Pilihan semen atau tanpa semen tersedia untuk mengakomodasi berbagai kualitas tulang dan preferensi bedah.
Mengurangi nyeri kronis yang disebabkan oleh kerusakan sendi, secara signifikan meningkatkan kualitas hidup.
Memungkinkan pasien untuk mendapatkan kembali pergerakan dan melakukan aktivitas sehari -hari tanpa batasan.
Desain implan lanjutan memastikan stabilitas dan meminimalkan risiko dislokasi sendi.
Bahan dan teknik modern memberikan implan dengan masa hidup yang diperluas dan kinerja yang andal.
Komponen modular dan spesifik ukuran memungkinkan pendekatan yang disesuaikan untuk memenuhi kebutuhan anatomi individu.
Teknik invasif minimal dan desain implan yang ditingkatkan mengurangi durasi pemulihan dan meningkatkan hasil.
Fraktur parah di tulang paha distal mungkin memerlukan penggantian lutut ketika metode fiksasi tradisional tidak cukup.
Penggantian lutut total dapat diindikasikan untuk fraktur yang membahayakan integritas sendi.
Pada pasien usia lanjut dengan kualitas tulang yang buruk, TKR memberikan solusi yang stabil dan andal.
Kasus di mana fiksasi fraktur sebelumnya gagal mungkin memerlukan konversi ke penggantian lutut total.
Infeksi pasca operasi dapat terjadi dan mungkin memerlukan intervensi tambahan.
Seiring waktu, implan dapat menjadi longgar, yang mengarah ke rasa sakit dan berkurangnya fungsi.
Deep Vein Trombosis (DVT) adalah komplikasi potensial setelah operasi penggantian lutut.
Contoh langka cedera pada saraf di sekitarnya atau pembuluh darah dapat terjadi.
Beberapa pasien mungkin mengalami kekakuan residual atau berkurangnya rentang gerak.
Reaksi hipersensitivitas yang jarang terhadap bahan implan dapat muncul.
Presisi yang ditingkatkan dan hasil yang lebih baik melalui prosedur penggantian lutut yang dibantu robot.
Kemajuan dalam pencetakan 3D dan pencitraan memungkinkan produksi implan spesifik pasien untuk kecocokan optimal.
Teknologi yang muncul menggabungkan sensor untuk memantau kinerja implan dan aktivitas pasien.
Inovasi berkelanjutan dalam pendekatan bedah mengurangi waktu pemulihan dan meningkatkan kepuasan pasien.
Memperluas akses ke perawatan kesehatan di pasar negara berkembang mendorong peningkatan permintaan untuk prosedur penggantian lutut.
Penelitian tentang bahan bioresorbable dan terapi regeneratif dapat menawarkan opsi alternatif atau tambahan di masa depan.
Penggantian lutut total primer adalah prosedur transformatif yang memberikan penghilang rasa sakit yang signifikan dan peningkatan mobilitas untuk pasien dengan kerusakan sendi lutut yang parah. Dengan fitur-fitur seperti komponen modular, material durabilitas tinggi, dan metode fiksasi canggih, ini memastikan kinerja yang andal dan manfaat jangka panjang. Sementara risiko ada, keuntungannya jauh lebih besar daripada tantangan, menjadikannya landasan perawatan ortopedi modern. Karena tren teknologi dan pasar terus berkembang, masa depan penggantian lutut total primer memiliki potensi besar untuk inovasi dan peningkatan hasil pasien.
Pengingat Hangat: Artikel ini hanya untuk referensi dan tidak dapat menggantikan saran profesional dokter. Jika Anda memiliki pertanyaan, silakan berkonsultasi dengan dokter yang hadir.
Xn-ps femoral condylar | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5210-01011 | 1L# | Lebar 57.5mm | Cocrmo | |
5210-01012 | 1R# | Lebar 57.5mm | ||
5210-01021 | 2L# | Lebar 60.5mm | ||
5210-01022 | 2R# | Lebar 60.5mm | ||
5210-01031 | 3L# | Lebar 63mm | ||
5210-01032 | 3R# | Lebar 63mm | ||
5210-01041 | 4L# | Lebar 65mm | ||
5210-01042 | 4r# | Lebar 65mm | ||
5210-01051 | 5L# | Lebar 67.5mm | ||
5210-01052 | 5R# | Lebar 67.5mm | ||
5210-01061 | 6L# | Lebar 70.5mm | ||
5210-01062 | 6r# | Lebar 70.5mm | ||
5210-01071 | 7L# | lebar 75mm | ||
5210-01072 | 7r# | lebar 75mm | ||
5210-01081 | 8L# | Lebar 78.5mm | ||
5210-01082 | 8r# | Lebar 78.5mm | ||
Condylar femoralis Xn-cr | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5214-01011 | 1L# | Lebar 57.5mm | Cocrmo | |
5214-01012 | 1R# | Lebar 57.5mm | ||
5214-01021 | 2L# | Lebar 60.5mm | ||
5214-01022 | 2R# | Lebar 60.5mm | ||
5214-01031 | 3L# | Lebar 63mm | ||
5214-01032 | 3R# | Lebar 63mm | ||
5214-01041 | 4L# | Lebar 65mm | ||
5214-01042 | 4r# | Lebar 65mm | ||
5214-01051 | 5L# | Lebar 67.5mm | ||
5214-01052 | 5R# | Lebar 67.5mm | ||
5214-01061 | 6L# | Lebar 70.5mm | ||
5214-01062 | 6r# | Lebar 70.5mm | ||
5214-01071 | 7L# | lebar 75mm | ||
5214-01072 | 7r# | lebar 75mm | ||
5214-01081 | 8L# | Lebar 78.5mm | ||
5214-01082 | 8r# | Lebar 78.5mm | ||
Sisipan XN-PS | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5217-10011 | 1# | 10mm | Uhmwpe | |
5217-12011 | 12mm | |||
5217-14011 | 14mm | |||
5217-16011 | 16mm | |||
5217-18011 | 18mm | |||
5217-10021 | 2#/3#/4# | 10mm | ||
5217-12021 | 12mm | |||
5217-14021 | 14mm | |||
5217-16021 | 16mm | |||
5217-18021 | 18mm | |||
5217-10031 | 5#/6# | 10mm | ||
5217-12031 | 12mm | |||
5217-14031 | 14mm | |||
5217-16031 | 16mm | |||
5217-18031 | 18mm | |||
5217-10041 | 7#/8# | 10mm | ||
5217-12041 | 12mm | |||
5217-14041 | 14mm | |||
5217-16041 | 16mm | |||
5217-18041 | 18mm | |||
Xn-PS Sisipkan (ve) | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5217-10011 | 1# | 10mm | Vitamin E sangat crosslink | |
5217-12011 | 12mm | |||
5217-14011 | 14mm | |||
5217-16011 | 16mm | |||
5217-18011 | 18mm | |||
5217-10021 | 2#/3#/4# | 10mm | ||
5217-12021 | 12mm | |||
5217-14021 | 14mm | |||
5217-16021 | 16mm | |||
5217-18021 | 18mm | |||
5217-10031 | 5#/6# | 10mm | ||
5217-12031 | 12mm | |||
5217-14031 | 14mm | |||
5217-16031 | 16mm | |||
5217-18031 | 18mm | |||
5217-10041 | 7#/8# | 10mm | ||
5217-12041 | 12mm | |||
5217-14041 | 14mm | |||
5217-16041 | 16mm | |||
5217-18041 | 18mm | |||
Insert xn-cr | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5218-10011 | 1# | 10mm | Uhmwpe | |
5218-12011 | 12mm | |||
5218-14011 | 14mm | |||
5218-16011 | 16mm | |||
5218-18011 | 18mm | |||
5218-10021 | 2#/3#/4# | 10mm | ||
5218-12021 | 12mm | |||
5218-14021 | 14mm | |||
5218-16021 | 16mm | |||
5218-18021 | 18mm | |||
5218-10031 | 5#/6# | 10mm | ||
5218-12031 | 12mm | |||
5218-14031 | 14mm | |||
5218-16031 | 16mm | |||
5218-18031 | 18mm | |||
5218-10041 | 7#/8# | 10mm | ||
5218-12041 | 12mm | |||
5218-14041 | 14mm | |||
5218-16041 | 16mm | |||
5218-18041 | 18mm | |||
Insert xn-cr | ||||
Kode | Ukuran | Ketebalan | Bahan | ![]() |
5218-10012 | 1# | 10mm | Vitamin E tinggi silang uhmwpe | |
5218-12012 | 12mm | |||
5218-14012 | 14mm | |||
5218-16012 | 16mm | |||
5218-18012 | 18mm | |||
5218-10022 | 2#/3#/4# | 10mm | ||
5218-12022 | 12mm | |||
5218-14022 | 14mm | |||
5218-16022 | 16mm | |||
5218-18022 | 18mm | |||
5218-10032 | 5#/6# | 10mm | ||
5218-12032 | 12mm | |||
5218-14032 | 14mm | |||
5218-16032 | 16mm | |||
5218-18032 | 18mm | |||
5218-10042 | 7#/8# | 10mm | ||
5218-12042 | 12mm | |||
5218-14042 | 14mm | |||
5218-16042 | 16mm | |||
5218-18042 | 18mm | |||
Xn-ps/cr nampan tibialis universal | ||||
Kode | Ukuran | Bahan | ![]() | |
5216-01010 | Baki Tibial 1# | Cocrmo | ||
5216-01020 | Baki Tibial 2# | |||
5216-01030 | Baki Tibial 3# | |||
5216-01040 | Baki Tibial 4# | |||
5216-01050 | Baki Tibial 5# | |||
5216-01060 | Baki Tibial 6# | |||
5216-01070 | Baki Tibial 7# | |||
5216-01080 | Baki Tibial 8# | |||
XN Patellar | ||||
Kode | Ketebalan | Diameter | Bahan | ![]() |
5213-08260 | 8mm | 26mm | Uhmwpe | |
5213-08280 | 28mm | |||
5213-08300 | 30mm | |||
5213-08320 | 32mm | |||
5213-10260 | 10mm | 26mm | ||
5213-10280 | 28mm | |||
5213-10300 | 30mm | |||
5213-10320 | 32mm | |||
5213-12260 | 12mm | 26mm | ||
5213-12280 | 28mm | |||
5213-12300 | 30mm | |||
5213-12320 | 32mm | |||
XM-PS Femoral Condylar | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5110-03021 | 2L# | Lebar 57mm | Cocrmo | |
5110-03022 | 2R# | Lebar 57mm | ||
5110-03031 | 3L# | lebar 60mm | ||
5110-03032 | 3R# | lebar 60mm | ||
5110-03041 | 4L# | lebar 62mm | ||
5110-03042 | 4r# | lebar 62mm | ||
5110-03051 | 5L# | Lebar 65mm | ||
5110-03052 | 5R# | Lebar 65mm | ||
5110-03061 | 6L# | Lebar 67mm | ||
5110-03062 | 6r# | Lebar 67mm | ||
5110-03071 | 7L# | lebar 70mm | ||
5110-03072 | 7r# | lebar 70mm | ||
5110-03081 | 8L# | lebar 72mm | ||
5110-03082 | 8r# | lebar 72mm | ||
5110-03101 | 10L# | lebar 77mm | ||
5110-03102 | 10R# | lebar 77mm | ||
XM-PS Femoral Condylar | ||||
Kode | Ukuran | Keterangan | Bahan | ![]() |
5114-03011 | 2L# | Lebar 57mm | Cocrmo | |
5114-03012 | 2R# | Lebar 57mm | ||
5114-03021 | 3L# | lebar 60mm | ||
5114-03022 | 3R# | lebar 60mm | ||
5114-03031 | 4L# | lebar 62mm | ||
5114-03032 | 4r# | lebar 62mm | ||
5114-03041 | 5L# | Lebar 65mm | ||
5114-03042 | 5R# | Lebar 65mm | ||
5114-03051 | 6L# | Lebar 67mm | ||
5114-03052 | 6r# | Lebar 67mm | ||
5114-03061 | 7L# | lebar 70mm | ||
5114-03062 | 7r# | lebar 70mm | ||
5114-03071 | 8L# | lebar 72mm | ||
5114-03072 | 8r# | lebar 72mm | ||
5114-03091 | 10L# | lebar 77mm | ||
5114-03092 | 10R# | lebar 77mm | ||
Sisipan XM-PS | ||||
Kode | Ukuran | Ketebalan/lebar | Bahan | ![]() |
5112-09021 | 2# | 9mm/62mm | UHMWPE / HXLPE / VE-HXL | |
5112-11021 | 11mm/62mm | |||
5112-13021 | 13mm/62mm | |||
5112-15021 | 15mm/62mm | |||
5112-17021 | 17mm/62mm | |||
5112-19021 | 19mm/62mm | |||
5112-09041 | 3/4# | 9mm/67mm | ||
5112-11041 | 11mm/67mm | |||
5112-13041 | 13mm/67mm | |||
5112-15041 | 15mm/67mm | |||
5112-17041 | 17mm/67mm | |||
5112-19041 | 19mm/67mm | |||
5112-09061 | 5/6# | 9mm/72mm | ||
5112-11061 | 11mm/72mm | |||
5112-13061 | 13mm/72mm | |||
5112-15061 | 15mm/72mm | |||
5112-17061 | 17mm/72mm | |||
5112-19061 | 19mm/72mm | |||
5112-09081 | 7/8# | 9mm/77mm | ||
5112-11081 | 11mm/77mm | |||
5112-13081 | 13mm/77mm | |||
5112-15081 | 15mm/77mm | |||
5112-17081 | 17mm/77mm | |||
5112-19081 | 19mm/77mm | |||
5112-09101 | 10# | 9mm/82mm | ||
5112-11101 | 11mm/82mm | |||
5112-13101 | 13mm/82mm | |||
5112-15101 | 15mm/82mm | |||
5112-17101 | 17mm/82mm | |||
5112-19101 | 19mm/82mm | |||
Insert xm-cr | ||||
Kode | Ukuran | Ketebalan/lebar | Bahan | ![]() |
5115-09011 | 2# | 9mm/62mm | UHMWPE / HXLPE / VE-HXL | |
5115-11011 | 11mm/62mm | |||
5115-13011 | 13mm/62mm | |||
5115-15011 | 15mm/62mm | |||
5115-17011 | 17mm/62mm | |||
5115-19011 | 19mm/62mm | |||
5115-09031 | 3/4# | 9mm/67mm | ||
5115-11031 | 11mm/67mm | |||
5115-13031 | 13mm/67mm | |||
5115-15031 | 15mm/67mm | |||
5115-17031 | 17mm/67mm | |||
5115-19031 | 19mm/67mm | |||
5115-09051 | 5/6# | 9mm/72mm | ||
5115-11051 | 11mm/72mm | |||
5115-13051 | 13mm/72mm | |||
5115-15051 | 15mm/72mm | |||
5115-17051 | 17mm/72mm | |||
5115-19051 | 19mm/72mm | |||
5115-09071 | 7/8# | 9mm/77mm | ||
5115-11071 | 11mm/77mm | |||
5115-13071 | 13mm/77mm | |||
5115-15071 | 15mm/77mm | |||
5115-17071 | 17mm/77mm | |||
5115-19071 | 19mm/77mm | |||
5115-09091 | 10# | 9mm/82mm | ||
5115-11091 | 11mm/82mm | |||
5115-13091 | 13mm/82mm | |||
5115-15091 | 15mm/82mm | |||
5115-17091 | 17mm/82mm | |||
5115-19091 | 19mm/82mm | |||
XM Tibia Tray Cr & PS Baki Tibial (Cljmc) | ||||
Kode | Ukuran | Bahan | ![]() | |
5111-01020 | 2#, 62mm | Cocrmo | ||
5111-01030 | 3#, 65mm | |||
5111-01040 | 4#, 67mm | |||
5111-01050 | 5#, 70mm | |||
5111-01060 | 6#, 71mm | |||
5111-01070 | 7#, 75mm | |||
5111-01080 | 8#, 76mm | |||
5111-01100 | 10#, 82mm | |||
XM Patellar | ||||
Kode | Ketebalan | Diameter | Bahan | ![]() |
5214-08260 | 8mm | 26mm | UHMWPE / HXLPE / VE-HXL | |
5214-08290 | 29mm | |||
5214-08320 | 32mm | |||
5214-08350 | 35mm | |||
5214-10260 | 10mm | 26mm | ||
5214-10290 | 29mm | |||
5214-10320 | 32mm | |||
5214-10350 | 35mm | |||
5214-12260 | 12mm | 26mm | ||
5214-12290 | 29mm | |||
5214-12320 | 32mm | |||
5214-12350 | 35mm |
Pemrosesan pendahuluan CNC Teknologi kontrol numerik komputer digunakan untuk memproses produk ortopedi secara tepat. Proses ini memiliki karakteristik presisi tinggi, efisiensi tinggi, dan pengulangan. Ini dapat dengan cepat menghasilkan perangkat medis khusus yang sesuai dengan struktur anatomi manusia dan memberikan pasien dengan rencana perawatan yang dipersonalisasi. | Pemolesan produk Tujuan pemolesan produk ortopedi adalah untuk meningkatkan kontak antara implan dan jaringan manusia, mengurangi konsentrasi stres, dan meningkatkan stabilitas jangka panjang implan. | Inspeksi Kualitas Uji sifat mekanik produk ortopedi dirancang untuk mensimulasikan kondisi stres tulang manusia, mengevaluasi kapasitas penahan beban dan daya tahan implan dalam tubuh manusia, dan memastikan keamanan dan keandalannya. |
Paket produk Produk ortopedi dikemas di ruang steril untuk memastikan bahwa produk dienkapsulasi dalam lingkungan yang bersih dan steril untuk mencegah kontaminasi mikroba dan memastikan keamanan bedah. |
Penyimpanan produk ortopedi membutuhkan manajemen masuk-dan-keluar yang ketat dan kontrol kualitas untuk memastikan keterlacakan produk dan mencegah kedaluwarsa atau pengiriman yang salah. |
Ruang sampel digunakan untuk menyimpan, menampilkan, dan mengelola berbagai sampel produk ortopedi untuk pertukaran dan pelatihan teknologi produk. |
1. Minta tim XC Medico untuk katalog produk lutut total utama.
2. Pilih produk lutut total utama Anda yang tertarik.
3. Minta sampel untuk menguji total lutut primer.
4. Buat pesanan lutut total utama XC Medico.
5. Berdasarkan dealer lutut total utama XC Medico.
1. Harga pembelian lebih baik dari total lutut primer.
2,100% Lutut total primer berkualitas tinggi.
3. Upaya pemesanan yang lebih sedikit.
4. Stabilitas harga untuk periode perjanjian.
5. Lutut total primer yang cukup.
6. Penilaian cepat dan mudah dari lutut total utama XC Medico.
7. Merek yang diakui secara global - XC Medico.
8. Waktu akses cepat ke tim penjualan XC Medico.
9. Tes kualitas tambahan oleh tim XC Medico.
10. Lacak pesanan XC Medico Anda dari awal hingga akhir.
Operasi penggantian lutut telah menjadi landasan perawatan ortopedi, secara signifikan meningkatkan mobilitas dan kualitas hidup bagi jutaan pasien. Penggantian lutut total primer (TKR) adalah prosedur yang dilakukan secara luas yang dirancang untuk mengatasi kerusakan sendi lutut yang parah yang disebabkan oleh radang sendi, trauma, atau kondisi degeneratif. Panduan ini menyediakan eksplorasi mendalam dari penggantian lutut total primer, termasuk fitur, keunggulan, aplikasi, risiko, dan tren pasar di masa depan.
Penggantian lutut total primer mengacu pada prosedur bedah awal yang dilakukan untuk menggantikan sendi lutut yang rusak dengan implan prostetik. Prosedur ini umumnya diindikasikan untuk pasien yang menderita nyeri yang melemahkan dan keterbatasan fungsional karena kondisi seperti osteoartritis, rheumatoid arthritis, atau arthritis pasca-trauma. Tujuan utama adalah untuk mengembalikan fungsi sendi, mengurangi rasa sakit, dan meningkatkan mobilitas keseluruhan, memungkinkan pasien untuk kembali ke aktivitas sehari -hari.
Biasanya terdiri dari komponen femoral, tibial, dan patellar untuk fleksibilitas dan kustomisasi.
Implan terbuat dari bahan biokompatibel seperti paduan kobalt-kromium, titanium, atau polietilen untuk memastikan umur panjang dan meminimalkan keausan.
Dirancang untuk meniru gerakan alami lutut, mengurangi gesekan dan memastikan mobilitas yang halus.
Disesuaikan dengan kebutuhan masing -masing pasien, dengan bantalan seluler memberikan peningkatan fleksibilitas dan stabilitas.
Implan yang lebih baru memfasilitasi teknik bedah invasif minimal, mengurangi gangguan jaringan lunak.
Pilihan semen atau tanpa semen tersedia untuk mengakomodasi berbagai kualitas tulang dan preferensi bedah.
Mengurangi nyeri kronis yang disebabkan oleh kerusakan sendi, secara signifikan meningkatkan kualitas hidup.
Memungkinkan pasien untuk mendapatkan kembali pergerakan dan melakukan aktivitas sehari -hari tanpa batasan.
Desain implan lanjutan memastikan stabilitas dan meminimalkan risiko dislokasi sendi.
Bahan dan teknik modern memberikan implan dengan masa hidup yang diperluas dan kinerja yang andal.
Komponen modular dan spesifik ukuran memungkinkan pendekatan yang disesuaikan untuk memenuhi kebutuhan anatomi individu.
Teknik invasif minimal dan desain implan yang ditingkatkan mengurangi durasi pemulihan dan meningkatkan hasil.
Fraktur parah di tulang paha distal mungkin memerlukan penggantian lutut ketika metode fiksasi tradisional tidak cukup.
Penggantian lutut total dapat diindikasikan untuk fraktur yang membahayakan integritas sendi.
Pada pasien usia lanjut dengan kualitas tulang yang buruk, TKR memberikan solusi yang stabil dan andal.
Kasus di mana fiksasi fraktur sebelumnya gagal mungkin memerlukan konversi ke penggantian lutut total.
Infeksi pasca operasi dapat terjadi dan mungkin memerlukan intervensi tambahan.
Seiring waktu, implan dapat menjadi longgar, yang mengarah ke rasa sakit dan berkurangnya fungsi.
Deep Vein Trombosis (DVT) adalah komplikasi potensial setelah operasi penggantian lutut.
Contoh langka cedera pada saraf di sekitarnya atau pembuluh darah dapat terjadi.
Beberapa pasien mungkin mengalami kekakuan residual atau berkurangnya rentang gerak.
Reaksi hipersensitivitas yang jarang terhadap bahan implan dapat muncul.
Presisi yang ditingkatkan dan hasil yang lebih baik melalui prosedur penggantian lutut yang dibantu robot.
Kemajuan dalam pencetakan 3D dan pencitraan memungkinkan produksi implan spesifik pasien untuk kecocokan optimal.
Teknologi yang muncul menggabungkan sensor untuk memantau kinerja implan dan aktivitas pasien.
Inovasi berkelanjutan dalam pendekatan bedah mengurangi waktu pemulihan dan meningkatkan kepuasan pasien.
Memperluas akses ke perawatan kesehatan di pasar negara berkembang mendorong peningkatan permintaan untuk prosedur penggantian lutut.
Penelitian tentang bahan bioresorbable dan terapi regeneratif dapat menawarkan opsi alternatif atau tambahan di masa depan.
Penggantian lutut total primer adalah prosedur transformatif yang memberikan penghilang rasa sakit yang signifikan dan peningkatan mobilitas untuk pasien dengan kerusakan sendi lutut yang parah. Dengan fitur-fitur seperti komponen modular, material durabilitas tinggi, dan metode fiksasi canggih, ini memastikan kinerja yang andal dan manfaat jangka panjang. Sementara risiko ada, keuntungannya jauh lebih besar daripada tantangan, menjadikannya landasan perawatan ortopedi modern. Karena tren teknologi dan pasar terus berkembang, masa depan penggantian lutut total primer memiliki potensi besar untuk inovasi dan peningkatan hasil pasien.
Pengingat Hangat: Artikel ini hanya untuk referensi dan tidak dapat menggantikan saran profesional dokter. Jika Anda memiliki pertanyaan, silakan berkonsultasi dengan dokter yang hadir.
Konten kosong!
Kontak