RQG2D01
XcMedico
1 PCs (72 Stunden Lieferung)
Femoral
Medizinischer Edelstahl
CE/ISO: 9001/ISO13485.ETC
Sonderangebot 15 Tage Lieferung (ohne Versandzeit)
FedEx. Dhl.tnt.ems.etc
Verfügbarkeit: | |
---|---|
Menge: | |
Produkte | Bilder | Details | ||||
Umgekehrter Femoral- und Gama Intramedullarynail Instrument Set (PN: RQG2D01) | ![]() | 1 | N-04-01 | Solid Reamer Ø9 | 1 | |
2 | N-04-02 | Solid Reamer Ø10 | 1 | |||
3 | N-04-03 | Solid Reamer Ø11 | 1 | |||
4 | N-04-04 | Solid Reamer Ø12 | 1 | |||
5 | N-04-05 | Solid Reamer Ø13 | 1 | |||
6 | N-04-06 | Bohrer | 1 | |||
7 | N-04-07 | Fadenk-Wire | 2 | |||
8 | N-04-08 | K-Draht | 2 | |||
9 | N-04-09 | Tiefe Gague 0-90 mm | 1 | |||
10 | N-04-10 | Schlüssel | 1 | |||
11 | N-04-11 | Schnelle Kopplung von T-Handle | 1 | |||
12 | N-04-12 | Sechsschraubendreher SW3.5 | 1 | |||
13 | N-04-13 | Bohrbit Ø4.5 | 1 | |||
14 | N-04-14 | Bohrbit Ø4.5 mit Stopper | 1 | |||
15 | N-04-15 | Offener Schraubenschlüssel | 1 | |||
16 | N-04-16 | Bohrlevel | 1 | |||
17 | N-04-17 | Bohrlevel | 1 | |||
18 | N-04-18 | Bohrlevel | 1 | |||
19 | N-04-19 | AHLE | 1 | |||
20 | N-04-20 | Hammer | 1 | |||
21 | N-04-21 | T-Handle Solid Reamer | 1 | |||
22 | N-04-22 | Ärmel | 1 | |||
23 | N-04-23 | Ärmel | 1 | |||
24 | N-04-24 | Standortkraft | 1 | |||
25 | N-04-25 | Ärmel | 1 | |||
26 | N-04-26 | Ärmel | 1 | |||
27 | N-04-27 | Klopfen | 1 | |||
28 | N-04-28 | Unverfestliches Gelenk | 1 | |||
29 | N-04-29 | Standortkraft | 1 | |||
30 | N-04-30 | Guider Bar | 1 | |||
31 | N-04-31 | Sechskantschlüssel groß | 1 | |||
32 | N-04-32 | Sechskantschlüssel klein | 1 | |||
33 | N-04-33 | Kegel kurz zwingen | 1 | |||
34 | N-04-34 | Kegel lang erzwingen | 1 | |||
35 | N-04-35 | Stecker | 1 | |||
36 | N-04-36 | Stecker | 1 | |||
37 | N-04-37 | Guider Griff | 1 | |||
38 | N-04-38 | Bolzen | 1 | |||
39 | N-04-39 | Bolzen | 1 | |||
40 | N-04-40 | Aluminiumbox | 1 |
Vorläufige Verarbeitung von CNC Die numerische Kontrolltechnologie Computer wird verwendet, um orthopädische Produkte genau zu verarbeiten. Dieser Prozess hat die Eigenschaften von hoher Präzision, hoher Effizienz und Wiederholbarkeit. Es kann schnell maßgeschneiderte medizinische Geräte herstellen, die der anatomischen Struktur der menschlichen Struktur entsprechen und Patienten personalisierte Behandlungspläne zur Verfügung stellen. | Produktpolieren Der Zweck von orthopädischen Produkten Polieren besteht darin, den Kontakt zwischen Implantat und menschlichem Gewebe zu verbessern, die Stresskonzentration zu verringern und die langfristige Stabilität des Implantats zu verbessern. | Qualitätsinspektion Der mechanische Eigenschaftenstest von orthopädischen Produkten soll die Spannungsbedingungen menschlicher Knochen simulieren, die tragende Kapazität und Haltbarkeit von Implantaten im menschlichen Körper bewerten und ihre Sicherheit und Zuverlässigkeit gewährleisten. |
Produktpaket Orthopädische Produkte werden in einem sterilen Raum verpackt, um sicherzustellen, dass das Produkt in einer sauberen, sterilen Umgebung eingekapselt ist, um mikrobielle Kontaminationen zu verhindern und die chirurgische Sicherheit zu gewährleisten. |
Die Speicherung von orthopädischen Produkten erfordert ein strengeres Management und eine Qualitätskontrolle, um die Produktverfolglichkeit zu gewährleisten und Ablauf oder falsche Versand zu verhindern. |
Der Probenraum wird verwendet, um verschiedene orthopädische Produkte für den Austausch und die Schulung von Produkttechnologie zu speichern, anzuzeigen und zu verwalten. |
1. Fragen Sie das XC Medico -Team für umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrument -Set
Produktkatalog.
2. Wählen Sie Ihr interessierte umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrument -Set
Produkt.
3.. Bitten Sie um eine Probe zum Testen umgekehrter Femoral- und Gama -Intramedullary -Nagelinstrument -Set
Qualität.
4. Machen Sie eine Reihenfolge der umgekehrten Femoral- und Gama -Intramedullary -Nagelinstrumenten -Set von XC Medico.
5.Become ein Händler des umgekehrten Femoral- und Gama -Intramedullary -Nagelinstruments -Sets von XC Medico.
1. Bessere Kaufpreise für umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrumenten -Set.
2,100% Die intramedulläre Nagelinstrumenten -Set mit intramedullärem Femoral und Gama von höchster Qualität.
3. weniger Bestellbemühungen.
4. Preisstabilität für den Zeitraum der Vereinbarung.
5. Ausreichende umgekehrte femorale und gama intramedulläre Nagelinstrumentset.
6. Schnelle und einfache Bewertung des umgekehrten Femoral- und Gama -Intramedullary -Nagelinstruments -Sets von XC Medico.
7. Eine global anerkannte Marke - XC Medico.
8. Schneller Zugriffszeit zum XC Medico -Verkaufsteam.
9. Zusätzlicher Qualitätstest vom XC Medico Team.
10. Verfolgen Sie Ihre XC Medico -Bestellung von Anfang bis Ende.
Umgekehrter Femoral- und Gamma -Set intramedullary Nagelinstrument ist ein spezielles chirurgisches Toolkit, mit dem umgekehrte femorale intramedulläre Nägel eingesetzt und repariert werden sollen, die zur Behandlung von Frakturen des Femurs und des Oberschenkelknochens verwendet werden. Diese Sets umfassen in der Regel eine Vielzahl von Instrumenten wie Reibahlen, Treiber, Insertionsinstrumente usw., mit denen Frakturen innerhalb des medullären Kanals des Femurs stabilisiert werden. insbesondere bei hochenergetischen Frakturen und Frakturen bei älteren Erwachsenen mit geschwächter Knochenqualität aufgrund von Osteoporose.
Die Instrumente sollten mit verschiedenen Arten von umgekehrten Femur- und Gamma-intramedullären Nägeln kompatibel sein, einschließlich Verriegelung und nicht sperren Nägeln.
Die Instrumente sollten auf Komfort und Benutzerfreundlichkeit ausgelegt sein, die die Ermüdung der Chirurgen verringern und die chirurgische Präzision verbessern.
Die Instrumente sollten aus hochwertigen Materialien hergestellt werden, die den strengen chirurgischen Eingriffen wie Titan und Chirurgie-Edelstahl standhalten können.
Das Instrument-Merkmal dieses Satzes ist das mehrdimensionale Targeting-System, das die genaue platzierende platzierende und proximale Verriegelungsschrauben zur Sicherung des intramedullären Nagels hilft.
Das intramedulläre Nagelinstrumenten -Set femorale Rekonstruktion bietet mehrere Vorteile, die es zu einer bevorzugten Wahl für komplexe femorale Bruchbehandlungen und -rekonstruktionen machen. Einer der Hauptvorteile ist die minimalinvasive Natur des intramedullären Nagels, bei dem kleinere Einschnitte und weniger Weichgewebestörungen im Vergleich zu offenen Operationen beinhalten. Dies führt zu verringerten postoperativen Schmerzen und schnelleren Erholungszeiten.
Durch das Platzieren des Nagels in den medullären Kanal des Knochens ist die Fixierung biomechanisch stabil und in der Lage, zusammen mit dem Femur Gewicht zu tragen, sodass die Patienten im Rahmen ihrer Rehabilitation frühes Gewichtsstrahlung beginnen können. Diese interne Fixierungsmethode unterstützt den natürlichen Heilungsprozess und verringert die Wahrscheinlichkeit von Komplikationen.
Das Set ist so konzipiert, dass sie verschiedene femorale Anatomien und Frakturarten unterbringen, darunter gehandelte, segmentale und pathologische Frakturen. Diese Flexibilität ermöglicht Chirurgen, die Instrumente anzupassen, um die spezifischen Anforderungen jedes Patienten zu erfüllen und eine optimale Ausrichtung und Stabilität zu gewährleisten.
Die Aufrechterhaltung der Sterilität ist entscheidend für die Vorbeugung von Infektionen. Die Instrumente müssen sorgfältig sterilisiert und gemäß aseptischen chirurgischen Protokollen behandelt werden, und Chirurgen müssen sicherstellen, dass jede Komponente vor der Verwendung ordnungsgemäß gereinigt und sterilisiert wird.
Regelmäßige Wartung und Kalibrierung der Instrumente sind wichtig, um ihre Genauigkeit und Zuverlässigkeit sicherzustellen.
Als Auswahl der korrekten Nagellänge und der richtigen Durchmesser basierend auf der Anatomie und dem Frakturmuster der Patienten ist für erfolgreiche Ergebnisse von entscheidender Bedeutung. Ein nicht ordnungsgemäß großer Nagel kann zu Komplikationen wie Implantatversagen, Malalignment oder sogar zusätzlichen Frakturen führen.
Sollte auch Vorsicht walten lassen, wenn Sie den Oberschenkelkanal bewegen und eine übermäßige Entfernung von Knochenmaterial vermeiden, um eine Schwächung der Knochenstruktur zu verhindern und das Risiko iatrogener Frakturen zu minimieren.
Der umgekehrte Markt für intramedulläre Nagelinstrumente mit Femoral & Gama wird in den kommenden Jahren aufgrund der Fortschritte in der orthopedischen Technologie, einer alternden Bevölkerung, einer Zunahme der Anzahl der Frakturen und der Notwendigkeit einer minimal invasiven orthopädischen chirurgischen Lösungen in den kommenden Jahren ein signifikantes Wachstum verzeichnen. Diese Faktoren verformern die Landschaft der Traumaversorgung und orthopädische Chirurgie und positionieren das umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrument als wesentliche Bestandteil des Frakturmanagements in den kommenden Jahren.
Zusammenfassend sind umgekehrte intramedulläre Nagelinstrumentsets für femorale und gama wesentliche Werkzeuge für orthopädische Chirurgen, die Tibia -Frakturen behandeln. Durch die Auswahl eines hochwertigen Instrumentensatzes können Chirurgen die Effizienz, Genauigkeit und Ergebnisse ihrer Verfahren verbessern.
Produkte | Bilder | Details | ||||
Umgekehrter Femoral- und Gama Intramedullarynail Instrument Set (PN: RQG2D01) | ![]() | 1 | N-04-01 | Solid Reamer Ø9 | 1 | |
2 | N-04-02 | Solid Reamer Ø10 | 1 | |||
3 | N-04-03 | Solid Reamer Ø11 | 1 | |||
4 | N-04-04 | Solid Reamer Ø12 | 1 | |||
5 | N-04-05 | Solid Reamer Ø13 | 1 | |||
6 | N-04-06 | Bohrer | 1 | |||
7 | N-04-07 | Fadenk-Wire | 2 | |||
8 | N-04-08 | K-Draht | 2 | |||
9 | N-04-09 | Tiefe Gague 0-90 mm | 1 | |||
10 | N-04-10 | Schlüssel | 1 | |||
11 | N-04-11 | Schnelle Kopplung von T-Handle | 1 | |||
12 | N-04-12 | Sechsschraubendreher SW3.5 | 1 | |||
13 | N-04-13 | Bohrbit Ø4.5 | 1 | |||
14 | N-04-14 | Bohrbit Ø4.5 mit Stopper | 1 | |||
15 | N-04-15 | Offener Schraubenschlüssel | 1 | |||
16 | N-04-16 | Bohrlevel | 1 | |||
17 | N-04-17 | Bohrlevel | 1 | |||
18 | N-04-18 | Bohrlevel | 1 | |||
19 | N-04-19 | AHLE | 1 | |||
20 | N-04-20 | Hammer | 1 | |||
21 | N-04-21 | T-Handle Solid Reamer | 1 | |||
22 | N-04-22 | Ärmel | 1 | |||
23 | N-04-23 | Ärmel | 1 | |||
24 | N-04-24 | Standortkraft | 1 | |||
25 | N-04-25 | Ärmel | 1 | |||
26 | N-04-26 | Ärmel | 1 | |||
27 | N-04-27 | Klopfen | 1 | |||
28 | N-04-28 | Unverfestliches Gelenk | 1 | |||
29 | N-04-29 | Standortkraft | 1 | |||
30 | N-04-30 | Guider Bar | 1 | |||
31 | N-04-31 | Sechskantschlüssel groß | 1 | |||
32 | N-04-32 | Sechskantschlüssel klein | 1 | |||
33 | N-04-33 | Kegel kurz zwingen | 1 | |||
34 | N-04-34 | Kegel lang erzwingen | 1 | |||
35 | N-04-35 | Stecker | 1 | |||
36 | N-04-36 | Stecker | 1 | |||
37 | N-04-37 | Guider Griff | 1 | |||
38 | N-04-38 | Bolzen | 1 | |||
39 | N-04-39 | Bolzen | 1 | |||
40 | N-04-40 | Aluminiumbox | 1 |
Vorläufige Verarbeitung von CNC Die numerische Kontrolltechnologie Computer wird verwendet, um orthopädische Produkte genau zu verarbeiten. Dieser Prozess hat die Eigenschaften von hoher Präzision, hoher Effizienz und Wiederholbarkeit. Es kann schnell maßgeschneiderte medizinische Geräte herstellen, die der anatomischen Struktur der menschlichen Struktur entsprechen und Patienten personalisierte Behandlungspläne zur Verfügung stellen. | Produktpolieren Der Zweck von orthopädischen Produkten Polieren besteht darin, den Kontakt zwischen Implantat und menschlichem Gewebe zu verbessern, die Stresskonzentration zu verringern und die langfristige Stabilität des Implantats zu verbessern. | Qualitätsinspektion Der mechanische Eigenschaftenstest von orthopädischen Produkten soll die Spannungsbedingungen menschlicher Knochen simulieren, die tragende Kapazität und Haltbarkeit von Implantaten im menschlichen Körper bewerten und ihre Sicherheit und Zuverlässigkeit gewährleisten. |
Produktpaket Orthopädische Produkte werden in einem sterilen Raum verpackt, um sicherzustellen, dass das Produkt in einer sauberen, sterilen Umgebung eingekapselt ist, um mikrobielle Kontaminationen zu verhindern und die chirurgische Sicherheit zu gewährleisten. |
Die Speicherung von orthopädischen Produkten erfordert ein strengeres Management und eine Qualitätskontrolle, um die Produktverfolglichkeit zu gewährleisten und Ablauf oder falsche Versand zu verhindern. |
Der Probenraum wird verwendet, um verschiedene orthopädische Produkte für den Austausch und die Schulung von Produkttechnologie zu speichern, anzuzeigen und zu verwalten. |
1. Fragen Sie das XC Medico -Team für umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrument -Set
Produktkatalog.
2. Wählen Sie Ihr interessierte umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrument -Set
Produkt.
3.. Bitten Sie um eine Probe zum Testen umgekehrter Femoral- und Gama -Intramedullary -Nagelinstrument -Set
Qualität.
4. Machen Sie eine Reihenfolge der umgekehrten Femoral- und Gama -Intramedullary -Nagelinstrumenten -Set von XC Medico.
5.Become ein Händler des umgekehrten Femoral- und Gama -Intramedullary -Nagelinstruments -Sets von XC Medico.
1. Bessere Kaufpreise für umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrumenten -Set.
2,100% Die intramedulläre Nagelinstrumenten -Set mit intramedullärem Femoral und Gama von höchster Qualität.
3. weniger Bestellbemühungen.
4. Preisstabilität für den Zeitraum der Vereinbarung.
5. Ausreichende umgekehrte femorale und gama intramedulläre Nagelinstrumentset.
6. Schnelle und einfache Bewertung des umgekehrten Femoral- und Gama -Intramedullary -Nagelinstruments -Sets von XC Medico.
7. Eine global anerkannte Marke - XC Medico.
8. Schneller Zugriffszeit zum XC Medico -Verkaufsteam.
9. Zusätzlicher Qualitätstest vom XC Medico Team.
10. Verfolgen Sie Ihre XC Medico -Bestellung von Anfang bis Ende.
Umgekehrter Femoral- und Gamma -Set intramedullary Nagelinstrument ist ein spezielles chirurgisches Toolkit, mit dem umgekehrte femorale intramedulläre Nägel eingesetzt und repariert werden sollen, die zur Behandlung von Frakturen des Femurs und des Oberschenkelknochens verwendet werden. Diese Sets umfassen in der Regel eine Vielzahl von Instrumenten wie Reibahlen, Treiber, Insertionsinstrumente usw., mit denen Frakturen innerhalb des medullären Kanals des Femurs stabilisiert werden. insbesondere bei hochenergetischen Frakturen und Frakturen bei älteren Erwachsenen mit geschwächter Knochenqualität aufgrund von Osteoporose.
Die Instrumente sollten mit verschiedenen Arten von umgekehrten Femur- und Gamma-intramedullären Nägeln kompatibel sein, einschließlich Verriegelung und nicht sperren Nägeln.
Die Instrumente sollten auf Komfort und Benutzerfreundlichkeit ausgelegt sein, die die Ermüdung der Chirurgen verringern und die chirurgische Präzision verbessern.
Die Instrumente sollten aus hochwertigen Materialien hergestellt werden, die den strengen chirurgischen Eingriffen wie Titan und Chirurgie-Edelstahl standhalten können.
Das Instrument-Merkmal dieses Satzes ist das mehrdimensionale Targeting-System, das die genaue platzierende platzierende und proximale Verriegelungsschrauben zur Sicherung des intramedullären Nagels hilft.
Das intramedulläre Nagelinstrumenten -Set femorale Rekonstruktion bietet mehrere Vorteile, die es zu einer bevorzugten Wahl für komplexe femorale Bruchbehandlungen und -rekonstruktionen machen. Einer der Hauptvorteile ist die minimalinvasive Natur des intramedullären Nagels, bei dem kleinere Einschnitte und weniger Weichgewebestörungen im Vergleich zu offenen Operationen beinhalten. Dies führt zu verringerten postoperativen Schmerzen und schnelleren Erholungszeiten.
Durch das Platzieren des Nagels in den medullären Kanal des Knochens ist die Fixierung biomechanisch stabil und in der Lage, zusammen mit dem Femur Gewicht zu tragen, sodass die Patienten im Rahmen ihrer Rehabilitation frühes Gewichtsstrahlung beginnen können. Diese interne Fixierungsmethode unterstützt den natürlichen Heilungsprozess und verringert die Wahrscheinlichkeit von Komplikationen.
Das Set ist so konzipiert, dass sie verschiedene femorale Anatomien und Frakturarten unterbringen, darunter gehandelte, segmentale und pathologische Frakturen. Diese Flexibilität ermöglicht Chirurgen, die Instrumente anzupassen, um die spezifischen Anforderungen jedes Patienten zu erfüllen und eine optimale Ausrichtung und Stabilität zu gewährleisten.
Die Aufrechterhaltung der Sterilität ist entscheidend für die Vorbeugung von Infektionen. Die Instrumente müssen sorgfältig sterilisiert und gemäß aseptischen chirurgischen Protokollen behandelt werden, und Chirurgen müssen sicherstellen, dass jede Komponente vor der Verwendung ordnungsgemäß gereinigt und sterilisiert wird.
Regelmäßige Wartung und Kalibrierung der Instrumente sind wichtig, um ihre Genauigkeit und Zuverlässigkeit sicherzustellen.
Als Auswahl der korrekten Nagellänge und der richtigen Durchmesser basierend auf der Anatomie und dem Frakturmuster der Patienten ist für erfolgreiche Ergebnisse von entscheidender Bedeutung. Ein nicht ordnungsgemäß großer Nagel kann zu Komplikationen wie Implantatversagen, Malalignment oder sogar zusätzlichen Frakturen führen.
Sollte auch Vorsicht walten lassen, wenn Sie den Oberschenkelkanal bewegen und eine übermäßige Entfernung von Knochenmaterial vermeiden, um eine Schwächung der Knochenstruktur zu verhindern und das Risiko iatrogener Frakturen zu minimieren.
Der umgekehrte Markt für intramedulläre Nagelinstrumente mit Femoral & Gama wird in den kommenden Jahren aufgrund der Fortschritte in der orthopedischen Technologie, einer alternden Bevölkerung, einer Zunahme der Anzahl der Frakturen und der Notwendigkeit einer minimal invasiven orthopädischen chirurgischen Lösungen in den kommenden Jahren ein signifikantes Wachstum verzeichnen. Diese Faktoren verformern die Landschaft der Traumaversorgung und orthopädische Chirurgie und positionieren das umgekehrte Femoral- und Gama -Intramedullary -Nagelinstrument als wesentliche Bestandteil des Frakturmanagements in den kommenden Jahren.
Zusammenfassend sind umgekehrte intramedulläre Nagelinstrumentsets für femorale und gama wesentliche Werkzeuge für orthopädische Chirurgen, die Tibia -Frakturen behandeln. Durch die Auswahl eines hochwertigen Instrumentensatzes können Chirurgen die Effizienz, Genauigkeit und Ergebnisse ihrer Verfahren verbessern.
Kontakt