RQG2D01
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Medical Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Products | Pictures | Details | ||||
Reversed Femoral & Gama IntramedullaryNail Instrument Set (PN:RQG2D01) | 1 | N-04-01 | Solid Reamer Ø9 | 1 | ||
2 | N-04-02 | Solid Reamer Ø10 | 1 | |||
3 | N-04-03 | Solid Reamer Ø11 | 1 | |||
4 | N-04-04 | Solid Reamer Ø12 | 1 | |||
5 | N-04-05 | Solid Reamer Ø13 | 1 | |||
6 | N-04-06 | Drill Bit | 1 | |||
7 | N-04-07 | Threaded K-wire | 2 | |||
8 | N-04-08 | K-wire | 2 | |||
9 | N-04-09 | Depth Gague 0-90mm | 1 | |||
10 | N-04-10 | Wrench | 1 | |||
11 | N-04-11 | Quick Coupling T-handle | 1 | |||
12 | N-04-12 | Hex Screwdriver SW3.5 | 1 | |||
13 | N-04-13 | Drill Bit Ø4.5 | 1 | |||
14 | N-04-14 | Drill Bit Ø4.5 with Stopper | 1 | |||
15 | N-04-15 | Open Wrench | 1 | |||
16 | N-04-16 | Drill Sleeve | 1 | |||
17 | N-04-17 | Drill Sleeve | 1 | |||
18 | N-04-18 | Drill Sleeve | 1 | |||
19 | N-04-19 | AWL | 1 | |||
20 | N-04-20 | Hammer | 1 | |||
21 | N-04-21 | T-handle Solid Reamer | 1 | |||
22 | N-04-22 | Sleeve | 1 | |||
23 | N-04-23 | Sleeve | 1 | |||
24 | N-04-24 | Location Forcep | 1 | |||
25 | N-04-25 | Sleeve | 1 | |||
26 | N-04-26 | Sleeve | 1 | |||
27 | N-04-27 | Tap | 1 | |||
28 | N-04-28 | Unversal Joint | 1 | |||
29 | N-04-29 | Location Forcep | 1 | |||
30 | N-04-30 | Guider Bar | 1 | |||
31 | N-04-31 | Hex Key Large | 1 | |||
32 | N-04-32 | Hex Key Small | 1 | |||
33 | N-04-33 | Forcing Cone Short | 1 | |||
34 | N-04-34 | Forcing Cone Long | 1 | |||
35 | N-04-35 | Connector | 1 | |||
36 | N-04-36 | Connector | 1 | |||
37 | N-04-37 | Guider Handle | 1 | |||
38 | N-04-38 | Bolt | 1 | |||
39 | N-04-39 | Bolt | 1 | |||
40 | N-04-40 | Aluminium Box | 1 |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Reversed Femoral & Gama Intramedullary Nail Instrument Set
Product Catalog.
2. Choose Your Interested Reversed Femoral & Gama Intramedullary Nail Instrument Set
Product.
3. Ask For A Sample To Test Reversed Femoral & Gama Intramedullary Nail Instrument Set
Quality.
4.Make An Order Of Xc Medico's Reversed Femoral & Gama Intramedullary Nail Instrument Set.
5.Become A Dealer Of Xc Medico's Reversed Femoral & Gama Intramedullary Nail Instrument Set.
1. Better Purchase Prices Of Reversed Femoral & Gama Intramedullary Nail Instrument Set.
2.100% The Highest Quality Reversed Femoral & Gama Intramedullary Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Reversed Femoral & Gama Intramedullary Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's Reversed Femoral & Gama Intramedullary Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Reversed femoral and gamma intramedullary nail instrument set is a specialized surgical toolkit designed to insert and fix reverse femoral intramedullary nails, which are used to treat fractures of the femur and the thigh bone. These sets typically include a variety of instruments, such as reamers, drivers, insertion instruments, etc. which are used to stabilize fractures within the femur's medullary canal. particularly for high-energy fractures and fractures in older adults with weakened bone quality due to osteoporosis.
The instruments should be compatible with various types of reversed femoral and gamma intramedullary nails, including locking and non-locking nails.
The instruments should be designed for comfort and ease of use, reducing surgeon fatigue and improving surgical precision.
The instruments should be made from high-quality materials that can withstand the rigors of surgical procedures like titanium and surgical-grade stainless steel.
The instrument's feature of this set is the multi-dimensional targeting system, which aids in accurately placing distal and proximal locking screws to secure the intramedullary nail.
The Femoral Reconstruction Intramedullary Nail Instrument Set offers several advantages that make it a preferred choice for complex femoral fracture treatments and reconstructions. One of the main benefits is the minimally invasive nature of intramedullary nailing, which involves smaller incisions and less soft tissue disruption compared to open surgeries. This leads to reduced post-operative pain and quicker recovery times.
By placing the nail within the bone’s medullary canal, the fixation is biomechanically stable and able to bear weight along with the femur, allowing patients to begin early weight-bearing as part of their rehabilitation. This internal fixation method supports the natural healing process and reduces the likelihood of complications.
The set is designed to accommodate various femoral anatomies and fracture types, including comminuted, segmental, and pathological fractures. This flexibility enables surgeons to adapt the instruments to meet the specific requirements of each patient, ensuring optimal alignment and stability.
Maintaining sterility is critical to preventing infections. The instruments must be meticulously sterilized and handled according to aseptic surgical protocols, and surgeons must ensure that each component is cleaned and sterilized properly before use.
Regular maintenance and calibration of the instruments are essential to ensure their accuracy and reliability.
as selecting the correct nail length and diameter based on patient anatomy and fracture pattern is vital for successful outcomes. An improperly sized nail can lead to complications such as implant failure, malalignment, or even additional fractures.
should also exercise caution when reaming the femoral canal, avoiding excessive removal of bone material to prevent weakening of the bone structure and minimizing the risk of iatrogenic fractures.
The reversed femoral & gama intramedullary nail instrument set market will witness significant growth in the coming years due to advancements in orthopedic technology, an aging population, an increase in the number of fractures, and the need for minimally invasive orthopedic surgical solutions. These factors are reshaping the landscape of trauma care and orthopedic surgery, positioning the reversed femoral & gama intramedullary nail instrument set as an essential component of fracture management in the coming years.
In conclusion, reversed femoral & gama intramedullary nail instrument sets are essential tools for orthopedic surgeons treating tibial fractures. By selecting a high-quality instrument set, surgeons can improve the efficiency, accuracy, and outcomes of their procedures.
Products | Pictures | Details | ||||
Reversed Femoral & Gama IntramedullaryNail Instrument Set (PN:RQG2D01) | 1 | N-04-01 | Solid Reamer Ø9 | 1 | ||
2 | N-04-02 | Solid Reamer Ø10 | 1 | |||
3 | N-04-03 | Solid Reamer Ø11 | 1 | |||
4 | N-04-04 | Solid Reamer Ø12 | 1 | |||
5 | N-04-05 | Solid Reamer Ø13 | 1 | |||
6 | N-04-06 | Drill Bit | 1 | |||
7 | N-04-07 | Threaded K-wire | 2 | |||
8 | N-04-08 | K-wire | 2 | |||
9 | N-04-09 | Depth Gague 0-90mm | 1 | |||
10 | N-04-10 | Wrench | 1 | |||
11 | N-04-11 | Quick Coupling T-handle | 1 | |||
12 | N-04-12 | Hex Screwdriver SW3.5 | 1 | |||
13 | N-04-13 | Drill Bit Ø4.5 | 1 | |||
14 | N-04-14 | Drill Bit Ø4.5 with Stopper | 1 | |||
15 | N-04-15 | Open Wrench | 1 | |||
16 | N-04-16 | Drill Sleeve | 1 | |||
17 | N-04-17 | Drill Sleeve | 1 | |||
18 | N-04-18 | Drill Sleeve | 1 | |||
19 | N-04-19 | AWL | 1 | |||
20 | N-04-20 | Hammer | 1 | |||
21 | N-04-21 | T-handle Solid Reamer | 1 | |||
22 | N-04-22 | Sleeve | 1 | |||
23 | N-04-23 | Sleeve | 1 | |||
24 | N-04-24 | Location Forcep | 1 | |||
25 | N-04-25 | Sleeve | 1 | |||
26 | N-04-26 | Sleeve | 1 | |||
27 | N-04-27 | Tap | 1 | |||
28 | N-04-28 | Unversal Joint | 1 | |||
29 | N-04-29 | Location Forcep | 1 | |||
30 | N-04-30 | Guider Bar | 1 | |||
31 | N-04-31 | Hex Key Large | 1 | |||
32 | N-04-32 | Hex Key Small | 1 | |||
33 | N-04-33 | Forcing Cone Short | 1 | |||
34 | N-04-34 | Forcing Cone Long | 1 | |||
35 | N-04-35 | Connector | 1 | |||
36 | N-04-36 | Connector | 1 | |||
37 | N-04-37 | Guider Handle | 1 | |||
38 | N-04-38 | Bolt | 1 | |||
39 | N-04-39 | Bolt | 1 | |||
40 | N-04-40 | Aluminium Box | 1 |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Reversed Femoral & Gama Intramedullary Nail Instrument Set
Product Catalog.
2. Choose Your Interested Reversed Femoral & Gama Intramedullary Nail Instrument Set
Product.
3. Ask For A Sample To Test Reversed Femoral & Gama Intramedullary Nail Instrument Set
Quality.
4.Make An Order Of Xc Medico's Reversed Femoral & Gama Intramedullary Nail Instrument Set.
5.Become A Dealer Of Xc Medico's Reversed Femoral & Gama Intramedullary Nail Instrument Set.
1. Better Purchase Prices Of Reversed Femoral & Gama Intramedullary Nail Instrument Set.
2.100% The Highest Quality Reversed Femoral & Gama Intramedullary Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Reversed Femoral & Gama Intramedullary Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's Reversed Femoral & Gama Intramedullary Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Reversed femoral and gamma intramedullary nail instrument set is a specialized surgical toolkit designed to insert and fix reverse femoral intramedullary nails, which are used to treat fractures of the femur and the thigh bone. These sets typically include a variety of instruments, such as reamers, drivers, insertion instruments, etc. which are used to stabilize fractures within the femur's medullary canal. particularly for high-energy fractures and fractures in older adults with weakened bone quality due to osteoporosis.
The instruments should be compatible with various types of reversed femoral and gamma intramedullary nails, including locking and non-locking nails.
The instruments should be designed for comfort and ease of use, reducing surgeon fatigue and improving surgical precision.
The instruments should be made from high-quality materials that can withstand the rigors of surgical procedures like titanium and surgical-grade stainless steel.
The instrument's feature of this set is the multi-dimensional targeting system, which aids in accurately placing distal and proximal locking screws to secure the intramedullary nail.
The Femoral Reconstruction Intramedullary Nail Instrument Set offers several advantages that make it a preferred choice for complex femoral fracture treatments and reconstructions. One of the main benefits is the minimally invasive nature of intramedullary nailing, which involves smaller incisions and less soft tissue disruption compared to open surgeries. This leads to reduced post-operative pain and quicker recovery times.
By placing the nail within the bone’s medullary canal, the fixation is biomechanically stable and able to bear weight along with the femur, allowing patients to begin early weight-bearing as part of their rehabilitation. This internal fixation method supports the natural healing process and reduces the likelihood of complications.
The set is designed to accommodate various femoral anatomies and fracture types, including comminuted, segmental, and pathological fractures. This flexibility enables surgeons to adapt the instruments to meet the specific requirements of each patient, ensuring optimal alignment and stability.
Maintaining sterility is critical to preventing infections. The instruments must be meticulously sterilized and handled according to aseptic surgical protocols, and surgeons must ensure that each component is cleaned and sterilized properly before use.
Regular maintenance and calibration of the instruments are essential to ensure their accuracy and reliability.
as selecting the correct nail length and diameter based on patient anatomy and fracture pattern is vital for successful outcomes. An improperly sized nail can lead to complications such as implant failure, malalignment, or even additional fractures.
should also exercise caution when reaming the femoral canal, avoiding excessive removal of bone material to prevent weakening of the bone structure and minimizing the risk of iatrogenic fractures.
The reversed femoral & gama intramedullary nail instrument set market will witness significant growth in the coming years due to advancements in orthopedic technology, an aging population, an increase in the number of fractures, and the need for minimally invasive orthopedic surgical solutions. These factors are reshaping the landscape of trauma care and orthopedic surgery, positioning the reversed femoral & gama intramedullary nail instrument set as an essential component of fracture management in the coming years.
In conclusion, reversed femoral & gama intramedullary nail instrument sets are essential tools for orthopedic surgeons treating tibial fractures. By selecting a high-quality instrument set, surgeons can improve the efficiency, accuracy, and outcomes of their procedures.
Contact