RPJPW1S.
XCMedico .
1 pcs) 72 horasta apachiy)
Aleación de Titanio .
CE/ISO:9001/ISO13485.
Rurasqa 15 p'unchawkuna apachiy (mana apachiy pacha)
Fedex. DHL.TNT.EMS.ETC .
Kawsay: | |
---|---|
Hayka: | |
Ruru | Rikchay | Ref . | Especificación nisqa. | Tornillo |
Plateo de la meseta tibial placa de bloqueo-I . | ![]() | RPJPW1S5HR . | 5 H R . | HA4,5 HC5,0. |
RPJPW1S5HL . | 5 H L . | HA4,5 HC5,0. | ||
RPJPW1S7HR . | 7 H R . | HA4,5 HC5,0. | ||
RPJPW1S7HL . | 7 H L . | HA4,5 HC5,0. | ||
RPJPW1S9HR . | 9 h r. | HA4,5 HC5,0. | ||
RPJPW1S9HL . | 9 h l. | HA4,5 HC5,0. | ||
RPJPW1S11HR . | 11 h r . | HA4,5 HC5,0. | ||
RPJPW1S11HL . | 11 H L . | HA4,5 HC5,0. | ||
RPJPW1S13HR . | 13 H R . | HA4,5 HC5,0. | ||
RPJPW1S13HL . | 13 H L . | HA4,5 HC5,0. |
CNC ñawpaq ruway . Computadora yupay control tecnologiaqa ortopédico nisqa rurukunata allinta ruwanapaqmi llamk'achinku. Kay ruwayqa hatun precisión, hatun eficiencia, repetibilidad nisqakunap imayna kayninmi. Chayqa usqhaylla ruwayta atin kay ruwasqa hampi aparatokunata kay runap estructura anatómica kaqninman hina chanta kay unqusqakunaman kay planes de tratamiento personalizados kaqwan qun. | Rurukuna llimp'iy . Kay ortopédico rurukuna llimp’ikuna kaqpa munayninqa kay implante kaqwan runap tejidonwan tupayta allinchaypaq, kay estrés concentración kaqta pisiyachinapaq, chanta kay implante kaqpa unay pachapaq estabilidadninta allinchaypaq. | Calidad nisqa qhaway . Chay prueba de propiedades mecánicas de productos ortopédicos nisqa ruwasqa kachkan, runapa tullunkunapa estrés nisqapa condicionninkunata simulananpaq, chay capacidad de carga de carga y durabilidad de los implantes en el cuerpo humano nisqa chaninchananpaq, chaynallataqmi seguridad nisqatapas, confiabilidad nisqatapas garantizananpaq. |
Paquete de Producto . Ortopédicos nisqa rurukunaqa huk cuarto estéril nisqapin paqueteasqa kanku, chaywanmi chay productoqa ch’uya, estéril nisqapi encapsulasqa kashan, chaywanmi mana microbial contaminación nisqa kananpaq, seguridad quirúrgica nisqa kananpaq. |
Ortopédico rurukuna waqaychayqa sinchi ukhupi-and-hawa kamachiy chaymanta calidad kamachiyta munan, ruru qatiy atiy kananpaq chaymanta tukukuy utaq pantasqa apachiy hark'anapaq. |
Chay muestra ruwana wasiqa imaymana ortopédico rurukuna muestrakuna waqaychaypaq, qhawaypaq chaymanta kamachiypaq llamk'achisqa, ruru tecnologia intercambios kaqpaq chaymanta yachachiypaq. |
1. Mañakuy XC Medico equipomanta tibial meseta lateral bloqueo placa-I catálogo de producto.
2. Akllay interesado tibial meseta lateral bloqueo placa-I producto.
3. Mañakuy huk muestra pruebapaq tibial meseta lateral bloqueo placa-I.
4.Haz una orden de XC Medicopa meseta tibial lateral de bloqueo-I.
5.Huk qhatuqman tukupuy XC Medicopa tibial meseta lateral bloqueo placa-I.
1.aswan allin rantiy chaninkuna tibial meseta lateral bloqueo placa-I.
2.100% Aswan allin calidad tibial meseta lateral bloqueo placa-I.
3. Aswan pisi kamachiy kallpachakuy.
4. Rimanakuy pachapaq chanin takyasqa.
5. Placa de bloqueo lateral de la meseta tibial suficiente-I.
6. Utqaylla hinaspa mana sasa chaninchay XC Medicopa tibial meseta lateral bloqueo placa-I.
7. Tukuy pacha riqsisqa marka - XC Medico.
8. XC Medico rantiq equipoman utqaylla yaykuy pacha.
9. Prueba adicional de calidad por XC Medico equipo.
10. XC Medico kamachiyniykita qallariymanta tukukuykama qatipay.
Kay placa de bloqueo lateral de la meseta tibial-I nisqaqa huk implante ortopédico especializada nisqa, chaymi ruwasqa estabilizar y promover la curación en las fracturas que afectan al aspecto lateral de la meseta tibial. Chayqa hukllachinmi principios biomecánicos puntales nisqakunata, contorno anatómico preciso nisqakunata, chaymanta tecnología de bloqueo avanzada nisqatapas, chaynapi fijación confiable nisqa kananpaq. Congruencia articular kaqmanta kutichispa chanta kay movilización temprana kaqta yanapaspa, kay implanteqa allin unqusqakunap ruwayninta chanta unay pachapaq conjunto qhali kayta yanapan.
Kay tibial meseta lateral bloqueo placa-I huk meticulosamente ingeniería ukhupi fijación dispositivo dirigido abordar fracturas de la meseta tibial lateral. Es distinto de los sistemas de chapa convencionales debido a su mecanismo de bloqueo y adaptación anatómica, iskayninku allinchanku estabilidadta hinallataq pisiyachinku riesgota implantewan tupaq complicaciones nisqamanta. Diseñado para su uso en fracturas intraarticulares y periarticulares complejos, kay placaqa cirujanosman atichin congruencia articularta kutichiyta, hark’anman cambios artriticos secundarios nisqakunata, chantapis mantener la capacidad de carga-aportación de rodilla.
Adecuado para tipos de fracturas diversos, incluyendo patrones comminutos, deprimidos y intra-articulares.
pre-formado para coincidir la única curvatura de la meseta tibial lateral, minimizando flexión intraoperatoria.
Fijo-ángulo tornillo uchkukuna huk rígido, takyasqa ruwayta ruwanku osteopenía tullupipas, micromoción riesgota pisiyachispa.
Tornillos de ángulo variable acomodar patrones de fracturas complejos, permitiendo cirujanos estrategias de fijación de sastrer.
Diseño anatómico,la forma de la placa acomoda a anatomía tibial meseta,fits cerca de minimizar irración de tejido blando.
Diseño limitado-contacto,con ventajas como preservación de suministro de sangre a tejido blando y tullu,reunión de las fracturas de tullu,etc.
combinación de bloqueo y compresión uchkukuna(combi uchkukuna),kay estabilidad angular utaq compresión llamk'achispa requisitos nisqaman hina.
Punta cónico nisqaqa inserción nisqapaqmi llamk’achinku viabilidad tisular nisqa kananpaq.
Congruencia articular kaqmanta kutichin, hark’an kay paso-offs kaqta kay artritis kaqman apayta atin.
Askha tullu t’aqakunata kamachin huk qaqa, hukllachasqa ruwayta ruwaspa, chaymi callo ruwayta yanapan.
eleva y estabiliza fragmentos deprimidos, manteniendo el perfil de superficie articulación.
Tornillos de bloqueo nisqa allin fijación nisqatam qun tullu calidad comprometida nisqapi, chaymi pisiyachin riesgota suchuchiyta.
Ofrece trayectorias de tornillo versatil para manejar geometrías de fractura complejas.
Mana allin pisiyachiy utaq biomecánicos factores hark’anman allin qhali kayta.
Hatun vasokunaman, nerviokunaman qaylla kayninqa, allinta qhawarikuq disección nisqatam necesitan.
Pisi perfilniyuq placas kaqpas wakin casospi mana allin kayta utaq tendón impingement kaqta ruwanman.
Reacciones de hipersensibilidad raras kay materiales de implantes kaqmanqa kay hardware hurquyta munanman.
Hamuq pacha paisaje para la placa de bloqueo lateral de la meseta tibial-I evolucionanqa tecnología hinallataq técnicas quirúrgicas ñawpaqman purisqanman hina, ofrecen oportunidades para mejorar el cuidado de los pacientes más.Morecimientos en materiales, como los revestimientos bioresorbables o bioactivos, pueden mejorar las osseointegración y reducir riesgos de infección. Kaywan kuskachasqa kay implantes específicos de paciente kaqwan kay 3D imprenta kaqwan chanta kay operación yanapasqa robot kaqwan, kay ñawpaqman puriykuna prometenku aswan precisión kaqwan, aswan pisi operativo pachakunawan chanta allinchasqa ruwaykunawan ima. Imaynatachus kay pachantinpi mañakuy allin calidad ortopédico kaqmanta wiñan, qhatuqa ñawpaqchasqa bloqueo placakuna mast’arikunqa, mask’aykunata chanta wiñachiyta kallpachanqa aswan allin chanta allin solucionkunaman tibial meseta fractura kamachiypaq.
Tukuchinapaq, kay tibial meseta lateral bloqueo placa-I epitomiza kay moderno principios de la innovación ortopédica kaqmanta —provechando robusta, biológicamente apoyo fijación kaqmanta kay unqusqakunata kallpachan kay movilidad chaymanta función kaqmanta ruwanankupaq. Entender sus características, concepto, ventajas, y futuro dirección equipa profesionales ortopédicos con las insights necesarias para optimizar el cuidado de los pacientes y establecer nuevas referencias en tratamiento de fractura.
Q’uñi yuyarichiy: Kay qillqasqaqa referenciallapaqmi, manataqmi doctorpa profesional consejontaqa cambiayta atinchu. Ima tapukuyniykipas kaptinqa, ama hina kaspa, hamuq hampiqniykiwan rimanakuy.
Ruru | Rikchay | Ref . | Especificación nisqa. | Tornillo |
Plateo de la meseta tibial placa de bloqueo-I . | ![]() | RPJPW1S5HR . | 5 H R . | HA4,5 HC5,0. |
RPJPW1S5HL . | 5 H L . | HA4,5 HC5,0. | ||
RPJPW1S7HR . | 7 H R . | HA4,5 HC5,0. | ||
RPJPW1S7HL . | 7 H L . | HA4,5 HC5,0. | ||
RPJPW1S9HR . | 9 h r. | HA4,5 HC5,0. | ||
RPJPW1S9HL . | 9 h l. | HA4,5 HC5,0. | ||
RPJPW1S11HR . | 11 h r . | HA4,5 HC5,0. | ||
RPJPW1S11HL . | 11 H L . | HA4,5 HC5,0. | ||
RPJPW1S13HR . | 13 H R . | HA4,5 HC5,0. | ||
RPJPW1S13HL . | 13 H L . | HA4,5 HC5,0. |
CNC ñawpaq ruway . Computadora yupay control tecnologiaqa ortopédico nisqa rurukunata allinta ruwanapaqmi llamk'achinku. Kay ruwayqa hatun precisión, hatun eficiencia, repetibilidad nisqakunap imayna kayninmi. Chayqa usqhaylla ruwayta atin kay ruwasqa hampi aparatokunata kay runap estructura anatómica kaqninman hina chanta kay unqusqakunaman kay planes de tratamiento personalizados kaqwan qun. | Rurukuna llimp'iy . Kay ortopédico rurukuna llimp’ikuna kaqpa munayninqa kay implante kaqwan runap tejidonwan tupayta allinchaypaq, kay estrés concentración kaqta pisiyachinapaq, chanta kay implante kaqpa unay pachapaq estabilidadninta allinchaypaq. | Calidad nisqa qhaway . Chay prueba de propiedades mecánicas de productos ortopédicos nisqa ruwasqa kachkan, runapa tullunkunapa estrés nisqapa condicionninkunata simulananpaq, chay capacidad de carga de carga y durabilidad de los implantes en el cuerpo humano nisqa chaninchananpaq, chaynallataqmi seguridad nisqatapas, confiabilidad nisqatapas garantizananpaq. |
Paquete de Producto . Ortopédicos nisqa rurukunaqa huk cuarto estéril nisqapin paqueteasqa kanku, chaywanmi chay productoqa ch’uya, estéril nisqapi encapsulasqa kashan, chaywanmi mana microbial contaminación nisqa kananpaq, seguridad quirúrgica nisqa kananpaq. |
Ortopédico rurukuna waqaychayqa sinchi ukhupi-and-hawa kamachiy chaymanta calidad kamachiyta munan, ruru qatiy atiy kananpaq chaymanta tukukuy utaq pantasqa apachiy hark'anapaq. |
Chay muestra ruwana wasiqa imaymana ortopédico rurukuna muestrakuna waqaychaypaq, qhawaypaq chaymanta kamachiypaq llamk'achisqa, ruru tecnologia intercambios kaqpaq chaymanta yachachiypaq. |
1. Mañakuy XC Medico equipomanta tibial meseta lateral bloqueo placa-I catálogo de producto.
2. Akllay interesado tibial meseta lateral bloqueo placa-I producto.
3. Mañakuy huk muestra pruebapaq tibial meseta lateral bloqueo placa-I.
4.Haz una orden de XC Medicopa meseta tibial lateral de bloqueo-I.
5.Huk qhatuqman tukupuy XC Medicopa tibial meseta lateral bloqueo placa-I.
1.aswan allin rantiy chaninkuna tibial meseta lateral bloqueo placa-I.
2.100% Aswan allin calidad tibial meseta lateral bloqueo placa-I.
3. Aswan pisi kamachiy kallpachakuy.
4. Rimanakuy pachapaq chanin takyasqa.
5. Placa de bloqueo lateral de la meseta tibial suficiente-I.
6. Utqaylla hinaspa mana sasa chaninchay XC Medicopa tibial meseta lateral bloqueo placa-I.
7. Tukuy pacha riqsisqa marka - XC Medico.
8. XC Medico rantiq equipoman utqaylla yaykuy pacha.
9. Prueba adicional de calidad por XC Medico equipo.
10. XC Medico kamachiyniykita qallariymanta tukukuykama qatipay.
Kay placa de bloqueo lateral de la meseta tibial-I nisqaqa huk implante ortopédico especializada nisqa, chaymi ruwasqa estabilizar y promover la curación en las fracturas que afectan al aspecto lateral de la meseta tibial. Chayqa hukllachinmi principios biomecánicos puntales nisqakunata, contorno anatómico preciso nisqakunata, chaymanta tecnología de bloqueo avanzada nisqatapas, chaynapi fijación confiable nisqa kananpaq. Congruencia articular kaqmanta kutichispa chanta kay movilización temprana kaqta yanapaspa, kay implanteqa allin unqusqakunap ruwayninta chanta unay pachapaq conjunto qhali kayta yanapan.
Kay tibial meseta lateral bloqueo placa-I huk meticulosamente ingeniería ukhupi fijación dispositivo dirigido abordar fracturas de la meseta tibial lateral. Es distinto de los sistemas de chapa convencionales debido a su mecanismo de bloqueo y adaptación anatómica, iskayninku allinchanku estabilidadta hinallataq pisiyachinku riesgota implantewan tupaq complicaciones nisqamanta. Diseñado para su uso en fracturas intraarticulares y periarticulares complejos, kay placaqa cirujanosman atichin congruencia articularta kutichiyta, hark’anman cambios artriticos secundarios nisqakunata, chantapis mantener la capacidad de carga-aportación de rodilla.
Adecuado para tipos de fracturas diversos, incluyendo patrones comminutos, deprimidos y intra-articulares.
pre-formado para coincidir la única curvatura de la meseta tibial lateral, minimizando flexión intraoperatoria.
Fijo-ángulo tornillo uchkukuna huk rígido, takyasqa ruwayta ruwanku osteopenía tullupipas, micromoción riesgota pisiyachispa.
Tornillos de ángulo variable acomodar patrones de fracturas complejos, permitiendo cirujanos estrategias de fijación de sastrer.
Diseño anatómico,la forma de la placa acomoda a anatomía tibial meseta,fits cerca de minimizar irración de tejido blando.
Diseño limitado-contacto,con ventajas como preservación de suministro de sangre a tejido blando y tullu,reunión de las fracturas de tullu,etc.
combinación de bloqueo y compresión uchkukuna(combi uchkukuna),kay estabilidad angular utaq compresión llamk'achispa requisitos nisqaman hina.
Punta cónico nisqaqa inserción nisqapaqmi llamk’achinku viabilidad tisular nisqa kananpaq.
Congruencia articular kaqmanta kutichin, hark’an kay paso-offs kaqta kay artritis kaqman apayta atin.
Askha tullu t’aqakunata kamachin huk qaqa, hukllachasqa ruwayta ruwaspa, chaymi callo ruwayta yanapan.
eleva y estabiliza fragmentos deprimidos, manteniendo el perfil de superficie articulación.
Tornillos de bloqueo nisqa allin fijación nisqatam qun tullu calidad comprometida nisqapi, chaymi pisiyachin riesgota suchuchiyta.
Ofrece trayectorias de tornillo versatil para manejar geometrías de fractura complejas.
Mana allin pisiyachiy utaq biomecánicos factores hark’anman allin qhali kayta.
Hatun vasokunaman, nerviokunaman qaylla kayninqa, allinta qhawarikuq disección nisqatam necesitan.
Pisi perfilniyuq placas kaqpas wakin casospi mana allin kayta utaq tendón impingement kaqta ruwanman.
Reacciones de hipersensibilidad raras kay materiales de implantes kaqmanqa kay hardware hurquyta munanman.
Hamuq pacha paisaje para la placa de bloqueo lateral de la meseta tibial-I evolucionanqa tecnología hinallataq técnicas quirúrgicas ñawpaqman purisqanman hina, ofrecen oportunidades para mejorar el cuidado de los pacientes más.Morecimientos en materiales, como los revestimientos bioresorbables o bioactivos, pueden mejorar las osseointegración y reducir riesgos de infección. Kaywan kuskachasqa kay implantes específicos de paciente kaqwan kay 3D imprenta kaqwan chanta kay operación yanapasqa robot kaqwan, kay ñawpaqman puriykuna prometenku aswan precisión kaqwan, aswan pisi operativo pachakunawan chanta allinchasqa ruwaykunawan ima. Imaynatachus kay pachantinpi mañakuy allin calidad ortopédico kaqmanta wiñan, qhatuqa ñawpaqchasqa bloqueo placakuna mast’arikunqa, mask’aykunata chanta wiñachiyta kallpachanqa aswan allin chanta allin solucionkunaman tibial meseta fractura kamachiypaq.
Tukuchinapaq, kay tibial meseta lateral bloqueo placa-I epitomiza kay moderno principios de la innovación ortopédica kaqmanta —provechando robusta, biológicamente apoyo fijación kaqmanta kay unqusqakunata kallpachan kay movilidad chaymanta función kaqmanta ruwanankupaq. Entender sus características, concepto, ventajas, y futuro dirección equipa profesionales ortopédicos con las insights necesarias para optimizar el cuidado de los pacientes y establecer nuevas referencias en tratamiento de fractura.
Q’uñi yuyarichiy: Kay qillqasqaqa referenciallapaqmi, manataqmi doctorpa profesional consejontaqa cambiayta atinchu. Ima tapukuyniykipas kaptinqa, ama hina kaspa, hamuq hampiqniykiwan rimanakuy.
Tupaqmasi