RG2NXSD nisqa.
XCMedico .
1 pcs) 72 horasta apachiy)
Femoral .
Aleación de titanio o acero inoxidable .
CE/ISO:9001/ISO13485.
Rurasqa 15 p'unchawkuna apachiy (mana apachiy pacha)
Fedex. DHL.TNT.EMS.ETC .
Kawsay: | |
---|---|
Hayka: | |
Ruru | Rikchay | Ref Titanio Aleación . | Especificación nisqa. |
Reverse femoral intramedular uña tupachiy 4.5mm tornillo de bloqueo hunt'a-roscado | ![]() | RG2NXSD09200. | ф9×200. |
RG2NXSD09220. | ф9×220. | ||
RG2NXSD09240. | ф9×240. | ||
RG2NXSD09260. | ф9×260. | ||
RG2NXSD09280. | ф9×280. | ||
RG2NXSD09300. | ф9×300. | ||
RG2NXSD10200. | ф10×200. | ||
RG2NXSD10220. | ф10×220. | ||
RG2NXSD10240. | ф10×240. | ||
RG2NXSD10260. | ф10×260. | ||
RG2NXSD10280. | ф10×280. | ||
RG2NXSD10300. | ф10×300. | ||
RG2NXSD11200. | ф11×200. | ||
RG2NXSD11220. | ф11×220. | ||
RG2NXSD11240. | ф11×240. | ||
RG2NXSD11260. | ф11×260. | ||
RG2NXSD11280. | ф11×280. | ||
RG2NXSD11300. | ф11×300. |
Inserto de uña inversamanta qunqurmanta .Kay llamp’u tejido chanta periósteo k’irisqa kay fractura muyuriqpi pisiyachisqa kay invertido femoral intramedular clavota kay qunqur articulación kaqmanta churaspa. |
Aswan akllanakuna .Material, Diámetro, Largo . ·Material: Titanio & acero inoxidable . ·Diámetro: 9mm/10mm/11mm nisqamanta. .largo: 200mm/220mm/240mm/260mm/280mm/ 300mm ·Tornillo:4.5mm Tornillo de bloqueo de rosca completa |
Diseño canulado .Perforaspa clavo sólido nisqa huk cansado nisqaman, asegura la fuerza y dureza de la clava intramedular femoral invertida. |
CNC ñawpaq ruway . Computadora yupay control tecnologiaqa ortopédico nisqa rurukunata allinta ruwanapaqmi llamk'achinku. Kay ruwayqa hatun precisión, hatun eficiencia, repetibilidad nisqakunap imayna kayninmi. Chayqa usqhaylla ruwayta atin kay ruwasqa hampi aparatokunata kay runap estructura anatómica kaqninman hina chanta kay unqusqakunaman kay planes de tratamiento personalizados kaqwan qun. | Rurukuna llimp'iy . Kay ortopédico rurukuna llimp’ikuna kaqpa munayninqa kay implante kaqwan runap tejidonwan tupayta allinchaypaq, kay estrés concentración kaqta pisiyachinapaq, chanta kay implante kaqpa unay pachapaq estabilidadninta allinchaypaq. | Calidad nisqa qhaway . Chay prueba de propiedades mecánicas de productos ortopédicos nisqa ruwasqa kachkan, runapa tullunkunapa estrés nisqapa condicionninkunata simulananpaq, chay capacidad de carga de carga y durabilidad de los implantes en el cuerpo humano nisqa chaninchananpaq, chaynallataqmi seguridad nisqatapas, confiabilidad nisqatapas garantizananpaq. |
Paquete de Producto . Ortopédicos nisqa rurukunaqa huk cuarto estéril nisqapin paqueteasqa kanku, chaywanmi chay productoqa ch’uya, estéril nisqapi encapsulasqa kashan, chaywanmi mana microbial contaminación nisqa kananpaq, seguridad quirúrgica nisqa kananpaq. |
Ortopédico rurukuna waqaychayqa sinchi ukhupi-and-hawa kamachiy chaymanta calidad kamachiyta munan, ruru qatiy atiy kananpaq chaymanta tukukuy utaq pantasqa apachiy hark'anapaq. |
Chay muestra ruwana wasiqa imaymana ortopédico rurukuna muestrakuna waqaychaypaq, qhawaypaq chaymanta kamachiypaq llamk'achisqa, ruru tecnologia intercambios kaqpaq chaymanta yachachiypaq. |
1. XC Medico equipota tapuy revertido femoral intramedular uña producto catálogo.
2. Akllay interesado inverso femoral intramedular uña producto.
3. Mañakuy huk muestra pruebapaq invertido femoral intramedular uña calidad kaqmanta.
4.Huk orden de XC Medicopa uña intramedular femoral invertida nisqamanta ruway.
5.Huk qhatuqman tukupuy XC Medicopa invertido femoral intramedular clavomanta.
1. Aswan allin rantiy chaninkuna invertido femoral intramedular clavo.
2.100% Kay aswan allin calidad kaqmanta kay uña intramedular femoral kaqmanta kutichisqa.
3. Aswan pisi kamachiy kallpachakuy.
4. Rimanakuy pachapaq chanin takyasqa.
5. suficiente inventario de uñas intramedular femoral invertida 5. .
6. Utqaylla hinaspa mana sasachakuspalla chaninchay XC Medicopa revertido femoral intramedular clavomanta.
7. Tukuy pacha riqsisqa marka - XC Medico.
8. XC Medico rantiq equipoman utqaylla yaykuy pacha.
9. Prueba adicional de calidad por XC Medico equipo.
10. XC Medico kamachiyniykita qallariymanta tukukuykama qatipay.
Uña intramedular femoral invertida nisqaqa huk especial tipo de uña intramedular nisqa, chaywanmi fracturas femoral distal nisqakunata hampinapaq. Allin estabilidad mecánica nisqayuqmi hinaspapas allintam controlanman desplazamiento posterior nisqatapas chaynallataq desplazamiento rotacional nisqatapas chay fracturapa extremo distal nisqamanta. Mana hinachu tradicional uñas intramedular femoral nisqakuna, chaykunan churasqa kanku fémur (qunqur) distal puntanmanta), chay clavo inverso nisqa churasqa kan chay punta proximal (cadera) nisqamanta.
Chay clavoqa churakunmi chay fémurpa puntan proximal (cadera) nisqamanta, chaymi aswan allin takyasqa kayta atin fracturas nisqapi cadera articulación nisqapa hichpanpi.
Uñas invertidas sapa kuti huk pisi hukniray diseño utaq curvaturayuq kanku kay punto de inserción proximal kaqninta acomodarpaq chaymanta allin alineación kaqta qunankupaq.
Chaykunaqa ñawpaqpi kaq clavokuna hina, tornillos de bloqueo nisqa hina, chay clavota tulluman allinta watanankupaq, chaypaqqa kikin mecanismos de bloqueo nisqakunatam servichikunmanku.
Uñas invertidas nisqakunaqa típicamente ruwasqa kanku kikin materialkunamanta ñawpaq uñakuna hina, ahinataq acero inoxidable utaq titanio, asegurando kallpata hinallataq biocompatibilidad nisqatapas.
Imaynachus tradicional uñakuna, uñas inversos ruwasqa kankuman kay hatun kayninpi, sayayninpi, chanta diseño kaqpi ima sapa unqusqapa necesidadninman hina chaymanta fractura patrón kaqman hina.
Kay punto de inserción proximal kaqqa aswan allin estabilidadta qunman kay fracturas kaqpi kay articulación cadera qayllapi, aswanta kay casos kaqpi maypichus kay tradicional uñas kaqkunaqa sasachakunkuman kay alineación kaqta waqaychaypaq.
Wakin kutikunapi, kay enfoque invertido kaqqa kay riesgota pisiyachinman kay complicaciones kaqmanta kayhina mana sindicato utaq malunión kaqmanta, particularmente kay fracturas complejas kaqpi.
Kay enfoque invertido kaqqa aswan pisi pasos quirúrgicos kaqta munanman kay tradicional clavos kaqwan kikinchasqa, potencialmente pisiyachispa kay riesgo complicaciones kaqmanta chanta kay resultados de pacientes kaqmanta allinchayta.
Chay invertido ruwayqa wakin kutipiqa aswan allin tullu hampiyta kallpachanmanmi wakin f nisqapi .
Chay uña intramedular femoral (IM) nisqaqa huk implante ortopédico nisqa, chaywanmi fracturas nisqakunata estabilizanku chay fémur nisqapi, piernas tullupi. Kay hamut’ayqa hap’inmi huk suni q’illay varilla churaypi chay fémurpa canal medular hueco nisqa ukhupi, chaymi yanapan alinear y estabilizar el hueso durante el proceso de curación.
Huk huch’uy incisión ruwakun cadera articulación qayllapi.
Chay clavo intramedular invertido nisqataqa canal medular nisqamanmi churanku, chay centroqa fémur nisqapa uchkunmi.
Tornillos de bloqueo nisqakunatam churanku fractura nisqapa hawanpi hinaspa urayninpi, chaynapi clavota allinta takyachinankupaq hinaspa mana kuyunanpaq.
Chay incisión nisqa wisq’asqa kachkan puntadas nisqawan utaq cola quirúrgica nisqawan.
Ratay
Mana sindicato utaq tarda sindicato .
Anterior qunqur nanay y rigidez .
Nervio y vascular lesión .
Síndrome de compartimiento .
Trombosis (yawar coágulos) .
Hip articulación involucramiento .
Pisi pisimanta llasaq kaywan, kuyuywan ima .
Terapia Física .
Síndrome de compartimiento nisqapaq qhaway .
Yawarpa ch'unchulmanta hark'akuynin .
Mana hatun ruwayniyuq ruwaykunamanta karunchakuy .
Cuidado postoperatorio kaqmanta kay invertido femoral intramedular (IM) uñakuna cirugía kaqmantaqa ancha allinmi hampiyta kallpachanapaq, complicaciones pisiyachiypaq, chanta huk allin allinyachiypaq. Chay enfoqueqa nanay kamachiymi、 cuidado de heridas、Peso-portado y movilidad、terapia física、 restricciones de actividad、Monitoring para complicaciones、Qatiy-up nombramientos、Nutrición y estilo de vida、Recuperación y rehabilitación de largo plazo.
Kay pacha llikata ruwayman kutiypaq kay invertido femoral intramedular uña operación kaqmanta qhipaman dependen kay laya fractura kaqmanta, estabilidad kaqmanta kay allichaymanta, chanta sapan hampiymanta ñawpaqman puriymanta. Generalmente, recuperación chaymanta niveles de actividad kaqwan pusasqa kanku kay cirujano kaqniykiwan chanta kay terapeuta físico kaqwan, kay normales actividades kaqmantaqa 6 killamanta wakmanta qallarikunman.
Apolpa investigacionninman hinaqa, 2023 watapi Global Intramedular Uñas qhatu rantikuyninqa yaqa 470 hunu US$ nisqa kanqa, chaymi suyakun wiñananta CAGR (Tasa de Crecimiento Anual de Compuesto) nisqapi 3,82% masnin 2024-2030 watapi. Kayqa rikuchin kay intramedular uña qhatu, kay invertido femoral intramedular uñakuna kaqwan, tukuy pachantinpi mast’arikunqa, huk hatun qhatu espaciota qun ruwaqkunapaq chaymanta suministradorkunapaq.
Clavado intramedular femoral inverso huk allin hampikuy método kaq, aswanta wakin laya fracturas femoral kaqpaq. Allin estabilidad kaqwan chanta pisi riesgo complicaciones kaqwan ima ventajasniyuq. Ichaqa, sichus akllakunman huk clavo inversata llamk’achiyta, chaytataq cirujano ortopédico kaqwan tanteanan tiyan kay unqusqap específicas situación kaqpi.
Q’uñi yuyarichiy: Kay qillqasqaqa referenciallapaqmi, manataqmi doctorpa profesional consejontaqa cambiayta atinchu. Ima tapukuyniykipas kaptinqa, ama hina kaspa, hamuq hampiqniykiwan rimanakuy.
Ruru | Rikchay | Ref Titanio Aleación . | Especificación nisqa. |
Reverse femoral intramedular uña tupachiy 4.5mm tornillo de bloqueo hunt'a-roscado | ![]() | RG2NXSD09200. | ф9×200. |
RG2NXSD09220. | ф9×220. | ||
RG2NXSD09240. | ф9×240. | ||
RG2NXSD09260. | ф9×260. | ||
RG2NXSD09280. | ф9×280. | ||
RG2NXSD09300. | ф9×300. | ||
RG2NXSD10200. | ф10×200. | ||
RG2NXSD10220. | ф10×220. | ||
RG2NXSD10240. | ф10×240. | ||
RG2NXSD10260. | ф10×260. | ||
RG2NXSD10280. | ф10×280. | ||
RG2NXSD10300. | ф10×300. | ||
RG2NXSD11200. | ф11×200. | ||
RG2NXSD11220. | ф11×220. | ||
RG2NXSD11240. | ф11×240. | ||
RG2NXSD11260. | ф11×260. | ||
RG2NXSD11280. | ф11×280. | ||
RG2NXSD11300. | ф11×300. |
Inserto de uña inversamanta qunqurmanta .Kay llamp’u tejido chanta periósteo k’irisqa kay fractura muyuriqpi pisiyachisqa kay invertido femoral intramedular clavota kay qunqur articulación kaqmanta churaspa. |
Aswan akllanakuna .Material, Diámetro, Largo . ·Material: Titanio & acero inoxidable . ·Diámetro: 9mm/10mm/11mm nisqamanta. .largo: 200mm/220mm/240mm/260mm/280mm/ 300mm ·Tornillo:4.5mm Tornillo de bloqueo de rosca completa |
Diseño canulado .Perforaspa clavo sólido nisqa huk cansado nisqaman, asegura la fuerza y dureza de la clava intramedular femoral invertida. |
CNC ñawpaq ruway . Computadora yupay control tecnologiaqa ortopédico nisqa rurukunata allinta ruwanapaqmi llamk'achinku. Kay ruwayqa hatun precisión, hatun eficiencia, repetibilidad nisqakunap imayna kayninmi. Chayqa usqhaylla ruwayta atin kay ruwasqa hampi aparatokunata kay runap estructura anatómica kaqninman hina chanta kay unqusqakunaman kay planes de tratamiento personalizados kaqwan qun. | Rurukuna llimp'iy . Kay ortopédico rurukuna llimp’ikuna kaqpa munayninqa kay implante kaqwan runap tejidonwan tupayta allinchaypaq, kay estrés concentración kaqta pisiyachinapaq, chanta kay implante kaqpa unay pachapaq estabilidadninta allinchaypaq. | Calidad nisqa qhaway . Chay prueba de propiedades mecánicas de productos ortopédicos nisqa ruwasqa kachkan, runapa tullunkunapa estrés nisqapa condicionninkunata simulananpaq, chay capacidad de carga de carga y durabilidad de los implantes en el cuerpo humano nisqa chaninchananpaq, chaynallataqmi seguridad nisqatapas, confiabilidad nisqatapas garantizananpaq. |
Paquete de Producto . Ortopédicos nisqa rurukunaqa huk cuarto estéril nisqapin paqueteasqa kanku, chaywanmi chay productoqa ch’uya, estéril nisqapi encapsulasqa kashan, chaywanmi mana microbial contaminación nisqa kananpaq, seguridad quirúrgica nisqa kananpaq. |
Ortopédico rurukuna waqaychayqa sinchi ukhupi-and-hawa kamachiy chaymanta calidad kamachiyta munan, ruru qatiy atiy kananpaq chaymanta tukukuy utaq pantasqa apachiy hark'anapaq. |
Chay muestra ruwana wasiqa imaymana ortopédico rurukuna muestrakuna waqaychaypaq, qhawaypaq chaymanta kamachiypaq llamk'achisqa, ruru tecnologia intercambios kaqpaq chaymanta yachachiypaq. |
1. XC Medico equipota tapuy revertido femoral intramedular uña producto catálogo.
2. Akllay interesado inverso femoral intramedular uña producto.
3. Mañakuy huk muestra pruebapaq invertido femoral intramedular uña calidad kaqmanta.
4.Huk orden de XC Medicopa uña intramedular femoral invertida nisqamanta ruway.
5.Huk qhatuqman tukupuy XC Medicopa invertido femoral intramedular clavomanta.
1. Aswan allin rantiy chaninkuna invertido femoral intramedular clavo.
2.100% Kay aswan allin calidad kaqmanta kay uña intramedular femoral kaqmanta kutichisqa.
3. Aswan pisi kamachiy kallpachakuy.
4. Rimanakuy pachapaq chanin takyasqa.
5. suficiente inventario de uñas intramedular femoral invertida 5. .
6. Utqaylla hinaspa mana sasachakuspalla chaninchay XC Medicopa revertido femoral intramedular clavomanta.
7. Tukuy pacha riqsisqa marka - XC Medico.
8. XC Medico rantiq equipoman utqaylla yaykuy pacha.
9. Prueba adicional de calidad por XC Medico equipo.
10. XC Medico kamachiyniykita qallariymanta tukukuykama qatipay.
Uña intramedular femoral invertida nisqaqa huk especial tipo de uña intramedular nisqa, chaywanmi fracturas femoral distal nisqakunata hampinapaq. Allin estabilidad mecánica nisqayuqmi hinaspapas allintam controlanman desplazamiento posterior nisqatapas chaynallataq desplazamiento rotacional nisqatapas chay fracturapa extremo distal nisqamanta. Mana hinachu tradicional uñas intramedular femoral nisqakuna, chaykunan churasqa kanku fémur (qunqur) distal puntanmanta), chay clavo inverso nisqa churasqa kan chay punta proximal (cadera) nisqamanta.
Chay clavoqa churakunmi chay fémurpa puntan proximal (cadera) nisqamanta, chaymi aswan allin takyasqa kayta atin fracturas nisqapi cadera articulación nisqapa hichpanpi.
Uñas invertidas sapa kuti huk pisi hukniray diseño utaq curvaturayuq kanku kay punto de inserción proximal kaqninta acomodarpaq chaymanta allin alineación kaqta qunankupaq.
Chaykunaqa ñawpaqpi kaq clavokuna hina, tornillos de bloqueo nisqa hina, chay clavota tulluman allinta watanankupaq, chaypaqqa kikin mecanismos de bloqueo nisqakunatam servichikunmanku.
Uñas invertidas nisqakunaqa típicamente ruwasqa kanku kikin materialkunamanta ñawpaq uñakuna hina, ahinataq acero inoxidable utaq titanio, asegurando kallpata hinallataq biocompatibilidad nisqatapas.
Imaynachus tradicional uñakuna, uñas inversos ruwasqa kankuman kay hatun kayninpi, sayayninpi, chanta diseño kaqpi ima sapa unqusqapa necesidadninman hina chaymanta fractura patrón kaqman hina.
Kay punto de inserción proximal kaqqa aswan allin estabilidadta qunman kay fracturas kaqpi kay articulación cadera qayllapi, aswanta kay casos kaqpi maypichus kay tradicional uñas kaqkunaqa sasachakunkuman kay alineación kaqta waqaychaypaq.
Wakin kutikunapi, kay enfoque invertido kaqqa kay riesgota pisiyachinman kay complicaciones kaqmanta kayhina mana sindicato utaq malunión kaqmanta, particularmente kay fracturas complejas kaqpi.
Kay enfoque invertido kaqqa aswan pisi pasos quirúrgicos kaqta munanman kay tradicional clavos kaqwan kikinchasqa, potencialmente pisiyachispa kay riesgo complicaciones kaqmanta chanta kay resultados de pacientes kaqmanta allinchayta.
Chay invertido ruwayqa wakin kutipiqa aswan allin tullu hampiyta kallpachanmanmi wakin f nisqapi .
Chay uña intramedular femoral (IM) nisqaqa huk implante ortopédico nisqa, chaywanmi fracturas nisqakunata estabilizanku chay fémur nisqapi, piernas tullupi. Kay hamut’ayqa hap’inmi huk suni q’illay varilla churaypi chay fémurpa canal medular hueco nisqa ukhupi, chaymi yanapan alinear y estabilizar el hueso durante el proceso de curación.
Huk huch’uy incisión ruwakun cadera articulación qayllapi.
Chay clavo intramedular invertido nisqataqa canal medular nisqamanmi churanku, chay centroqa fémur nisqapa uchkunmi.
Tornillos de bloqueo nisqakunatam churanku fractura nisqapa hawanpi hinaspa urayninpi, chaynapi clavota allinta takyachinankupaq hinaspa mana kuyunanpaq.
Chay incisión nisqa wisq’asqa kachkan puntadas nisqawan utaq cola quirúrgica nisqawan.
Ratay
Mana sindicato utaq tarda sindicato .
Anterior qunqur nanay y rigidez .
Nervio y vascular lesión .
Síndrome de compartimiento .
Trombosis (yawar coágulos) .
Hip articulación involucramiento .
Pisi pisimanta llasaq kaywan, kuyuywan ima .
Terapia Física .
Síndrome de compartimiento nisqapaq qhaway .
Yawarpa ch'unchulmanta hark'akuynin .
Mana hatun ruwayniyuq ruwaykunamanta karunchakuy .
Cuidado postoperatorio kaqmanta kay invertido femoral intramedular (IM) uñakuna cirugía kaqmantaqa ancha allinmi hampiyta kallpachanapaq, complicaciones pisiyachiypaq, chanta huk allin allinyachiypaq. Chay enfoqueqa nanay kamachiymi、 cuidado de heridas、Peso-portado y movilidad、terapia física、 restricciones de actividad、Monitoring para complicaciones、Qatiy-up nombramientos、Nutrición y estilo de vida、Recuperación y rehabilitación de largo plazo.
Kay pacha llikata ruwayman kutiypaq kay invertido femoral intramedular uña operación kaqmanta qhipaman dependen kay laya fractura kaqmanta, estabilidad kaqmanta kay allichaymanta, chanta sapan hampiymanta ñawpaqman puriymanta. Generalmente, recuperación chaymanta niveles de actividad kaqwan pusasqa kanku kay cirujano kaqniykiwan chanta kay terapeuta físico kaqwan, kay normales actividades kaqmantaqa 6 killamanta wakmanta qallarikunman.
Apolpa investigacionninman hinaqa, 2023 watapi Global Intramedular Uñas qhatu rantikuyninqa yaqa 470 hunu US$ nisqa kanqa, chaymi suyakun wiñananta CAGR (Tasa de Crecimiento Anual de Compuesto) nisqapi 3,82% masnin 2024-2030 watapi. Kayqa rikuchin kay intramedular uña qhatu, kay invertido femoral intramedular uñakuna kaqwan, tukuy pachantinpi mast’arikunqa, huk hatun qhatu espaciota qun ruwaqkunapaq chaymanta suministradorkunapaq.
Clavado intramedular femoral inverso huk allin hampikuy método kaq, aswanta wakin laya fracturas femoral kaqpaq. Allin estabilidad kaqwan chanta pisi riesgo complicaciones kaqwan ima ventajasniyuq. Ichaqa, sichus akllakunman huk clavo inversata llamk’achiyta, chaytataq cirujano ortopédico kaqwan tanteanan tiyan kay unqusqap específicas situación kaqpi.
Q’uñi yuyarichiy: Kay qillqasqaqa referenciallapaqmi, manataqmi doctorpa profesional consejontaqa cambiayta atinchu. Ima tapukuyniykipas kaptinqa, ama hina kaspa, hamuq hampiqniykiwan rimanakuy.
Tupaqmasi