RSSTKJ
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Pic | Screw | REF. | Spec. |
6.0mm Double Ends Cannulated Compression Screw | / | RSSTKJ6060 | 6.0*60mm | |
RSSTKJ6065 | 6.0*65mm | |||
RSSTKJ6070 | 6.0*70mm | |||
RSSTKJ6075 | 6.0*75mm | |||
RSSTKJ6080 | 6.0*80mm | |||
RSSTKJ6085 | 6.0*85mm | |||
RSSTKJ6090 | 6.0*90mm | |||
RSSTKJ6095 | 6.0*95mm | |||
RSSTKJ60100 | 6.0*100mm | |||
RSSTKJ60105 | 6.0*105mm | |||
RSSTKJ60110 | 6.0*110mm | |||
RSSTKJ60115 | 6.0*115mm | |||
RSSTKJ60120 | 6.0*120mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 6.0mm Double Ends Cannulated Compression Screw Product Catalog.
2. Choose Your Interested 6.0mm Double Ends Cannulated Compression Screw Product.
3. Ask For A Sample To Test 6.0mm Double Ends Cannulated Compression Screw.
4.Make An Order Of XC Medico's 6.0mm Double Ends Cannulated Compression Screw.
5.Become A Dealer Of XC Medico's 6.0mm Double Ends Cannulated Compression Screw.
1.Better Purchase Prices Of 6.0mm Double Ends Cannulated Compression Screw.
2.100% The Highest Quality 6.0mm Double Ends Cannulated Compression Screw.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 6.0mm Double Ends Cannulated Compression Screw.
6. Quick And Easy Assessment Of XC Medico's 6.0mm Double Ends Cannulated Compression Screw.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Orthopedic surgery has seen remarkable advancements with the development of specialized implants designed to promote faster healing and minimize complications. Among these innovations, the 6.0mm Double Ends Cannulated Compression Screw stands out as an essential tool for managing fractures, particularly in cases requiring controlled compression. This article provides an in-depth look into the features, advantages, and future potential of the 6.0mm Double Ends Cannulated Compression Screw, with a focus on its clinical utility and performance.
The 6.0mm Double Ends Cannulated Compression Screw is a medical device designed for the stabilization of fractures, especially those involving long bones such as the femur, tibia, and humerus. This screw is unique in that it features a double-ended design, which allows for the application of compressive forces from both ends of the fracture site, thereby facilitating improved alignment and healing. The cannulated design refers to the central hollow core of the screw, which allows it to be inserted over a guidewire, offering greater precision during surgery.
Typically used in intramedullary applications, the 6.0mm double-ended cannulated compression screw combines the benefits of ease of insertion, precise alignment, and optimal compression to enhance the healing process of bone fractures.
The hollow core allows for the easy insertion of the screw over a guidewire, ensuring accurate placement and reducing surgical trauma.
Two compression points help distribute forces evenly, enhancing fracture stability and promoting healing.
These threads cut into the bone, allowing for easier insertion without the need for pre-tapping, reducing surgery time.
The material is lightweight, biocompatible, and resistant to corrosion, ensuring long-lasting stability within the body.
The screw comes in various lengths to accommodate different bone sizes and fracture types, offering surgeons versatility.
Each screw is individually packaged and sterile, ensuring that it is safe for immediate use during surgery.
The unique double-ended compression mechanism promotes superior fracture stability by applying compression from both sides of the fracture, facilitating proper bone alignment and faster healing.
The cannulated design allows for precise placement over a guidewire, significantly reducing the time spent during surgery. Surgeons can work with greater confidence and accuracy, leading to improved patient outcomes.
The use of a cannulated screw allows for smaller incisions and minimal soft tissue dissection, contributing to quicker recovery times and reduced postoperative pain for patients.
Titanium alloy is known for its biocompatibility, which means that the screw will integrate well with bone tissue and is less likely to cause adverse reactions or infections.
With its range of lengths and sizes, the 6.0mm Double Ends Cannulated Compression Screw is suitable for managing a wide variety of fracture types, from simple bone fractures to complex multi-part fractures.
The screw is often used in fractures of the femur, tibia, and humerus, where controlled compression is needed for optimal bone healing.
In cases where the bone is broken into multiple pieces, the double-ended compression screw helps align and stabilize the fragments, ensuring proper healing.
For elderly patients with weakened bone structure, this screw offers enhanced stability to allow better fracture management and prevent secondary complications.
When a fracture fails to heal properly, the screw can be used as part of a revision surgery to help re-establish proper alignment and encourage union.
As with any implant, there is a risk of infection at the surgical site. Proper sterile techniques are essential to minimize this risk.
If the screw is not properly positioned or if the fracture does not heal as expected, there is a risk of the bone not healing correctly, leading to non-union or malunion.
While titanium is highly durable, there is still a slight risk that the screw may fail, especially in high-stress fractures or in patients with underlying bone diseases.
The placement of the screw near critical nerves or blood vessels can result in inadvertent injury during the procedure.
Although rare, some patients may experience persistent pain around the screw, particularly if there is irritation or friction.
The future of the 6.0mm Double Ends Cannulated Compression Screw looks promising, especially in light of advancements in orthopedic implant technology. The increasing prevalence of fractures, particularly in aging populations, is expected to drive the demand for high-quality, reliable implant solutions. The growing trend of minimally invasive surgeries is also likely to fuel the adoption of cannulated screws in clinical practice.
In addition, technological innovations such as 3D printing of personalized implants, biodegradable materials, and smart implants may further enhance the performance and application of the 6.0mm Double Ends Cannulated Compression Screw. As orthopedic surgeries continue to evolve, so too will the devices used to support recovery and healing.
The 6.0mm Double Ends Cannulated Compression Screw is a vital component of modern orthopedic surgery, offering numerous advantages, including enhanced fracture stability, reduced surgical time, and minimal invasiveness. Its versatility in treating various types of fractures and its use of biocompatible materials make it a trusted choice among orthopedic surgeons worldwide. While the risks associated with its use should not be overlooked, with proper surgical technique and patient selection, the 6.0mm Double Ends Cannulated Compression Screw can significantly improve patient outcomes and facilitate faster recovery. As the field of orthopedic implants continues to evolve, this screw is likely to remain a cornerstone in fracture management for years to come.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Pic | Screw | REF. | Spec. |
6.0mm Double Ends Cannulated Compression Screw | / | RSSTKJ6060 | 6.0*60mm | |
RSSTKJ6065 | 6.0*65mm | |||
RSSTKJ6070 | 6.0*70mm | |||
RSSTKJ6075 | 6.0*75mm | |||
RSSTKJ6080 | 6.0*80mm | |||
RSSTKJ6085 | 6.0*85mm | |||
RSSTKJ6090 | 6.0*90mm | |||
RSSTKJ6095 | 6.0*95mm | |||
RSSTKJ60100 | 6.0*100mm | |||
RSSTKJ60105 | 6.0*105mm | |||
RSSTKJ60110 | 6.0*110mm | |||
RSSTKJ60115 | 6.0*115mm | |||
RSSTKJ60120 | 6.0*120mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 6.0mm Double Ends Cannulated Compression Screw Product Catalog.
2. Choose Your Interested 6.0mm Double Ends Cannulated Compression Screw Product.
3. Ask For A Sample To Test 6.0mm Double Ends Cannulated Compression Screw.
4.Make An Order Of XC Medico's 6.0mm Double Ends Cannulated Compression Screw.
5.Become A Dealer Of XC Medico's 6.0mm Double Ends Cannulated Compression Screw.
1.Better Purchase Prices Of 6.0mm Double Ends Cannulated Compression Screw.
2.100% The Highest Quality 6.0mm Double Ends Cannulated Compression Screw.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 6.0mm Double Ends Cannulated Compression Screw.
6. Quick And Easy Assessment Of XC Medico's 6.0mm Double Ends Cannulated Compression Screw.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Orthopedic surgery has seen remarkable advancements with the development of specialized implants designed to promote faster healing and minimize complications. Among these innovations, the 6.0mm Double Ends Cannulated Compression Screw stands out as an essential tool for managing fractures, particularly in cases requiring controlled compression. This article provides an in-depth look into the features, advantages, and future potential of the 6.0mm Double Ends Cannulated Compression Screw, with a focus on its clinical utility and performance.
The 6.0mm Double Ends Cannulated Compression Screw is a medical device designed for the stabilization of fractures, especially those involving long bones such as the femur, tibia, and humerus. This screw is unique in that it features a double-ended design, which allows for the application of compressive forces from both ends of the fracture site, thereby facilitating improved alignment and healing. The cannulated design refers to the central hollow core of the screw, which allows it to be inserted over a guidewire, offering greater precision during surgery.
Typically used in intramedullary applications, the 6.0mm double-ended cannulated compression screw combines the benefits of ease of insertion, precise alignment, and optimal compression to enhance the healing process of bone fractures.
The hollow core allows for the easy insertion of the screw over a guidewire, ensuring accurate placement and reducing surgical trauma.
Two compression points help distribute forces evenly, enhancing fracture stability and promoting healing.
These threads cut into the bone, allowing for easier insertion without the need for pre-tapping, reducing surgery time.
The material is lightweight, biocompatible, and resistant to corrosion, ensuring long-lasting stability within the body.
The screw comes in various lengths to accommodate different bone sizes and fracture types, offering surgeons versatility.
Each screw is individually packaged and sterile, ensuring that it is safe for immediate use during surgery.
The unique double-ended compression mechanism promotes superior fracture stability by applying compression from both sides of the fracture, facilitating proper bone alignment and faster healing.
The cannulated design allows for precise placement over a guidewire, significantly reducing the time spent during surgery. Surgeons can work with greater confidence and accuracy, leading to improved patient outcomes.
The use of a cannulated screw allows for smaller incisions and minimal soft tissue dissection, contributing to quicker recovery times and reduced postoperative pain for patients.
Titanium alloy is known for its biocompatibility, which means that the screw will integrate well with bone tissue and is less likely to cause adverse reactions or infections.
With its range of lengths and sizes, the 6.0mm Double Ends Cannulated Compression Screw is suitable for managing a wide variety of fracture types, from simple bone fractures to complex multi-part fractures.
The screw is often used in fractures of the femur, tibia, and humerus, where controlled compression is needed for optimal bone healing.
In cases where the bone is broken into multiple pieces, the double-ended compression screw helps align and stabilize the fragments, ensuring proper healing.
For elderly patients with weakened bone structure, this screw offers enhanced stability to allow better fracture management and prevent secondary complications.
When a fracture fails to heal properly, the screw can be used as part of a revision surgery to help re-establish proper alignment and encourage union.
As with any implant, there is a risk of infection at the surgical site. Proper sterile techniques are essential to minimize this risk.
If the screw is not properly positioned or if the fracture does not heal as expected, there is a risk of the bone not healing correctly, leading to non-union or malunion.
While titanium is highly durable, there is still a slight risk that the screw may fail, especially in high-stress fractures or in patients with underlying bone diseases.
The placement of the screw near critical nerves or blood vessels can result in inadvertent injury during the procedure.
Although rare, some patients may experience persistent pain around the screw, particularly if there is irritation or friction.
The future of the 6.0mm Double Ends Cannulated Compression Screw looks promising, especially in light of advancements in orthopedic implant technology. The increasing prevalence of fractures, particularly in aging populations, is expected to drive the demand for high-quality, reliable implant solutions. The growing trend of minimally invasive surgeries is also likely to fuel the adoption of cannulated screws in clinical practice.
In addition, technological innovations such as 3D printing of personalized implants, biodegradable materials, and smart implants may further enhance the performance and application of the 6.0mm Double Ends Cannulated Compression Screw. As orthopedic surgeries continue to evolve, so too will the devices used to support recovery and healing.
The 6.0mm Double Ends Cannulated Compression Screw is a vital component of modern orthopedic surgery, offering numerous advantages, including enhanced fracture stability, reduced surgical time, and minimal invasiveness. Its versatility in treating various types of fractures and its use of biocompatible materials make it a trusted choice among orthopedic surgeons worldwide. While the risks associated with its use should not be overlooked, with proper surgical technique and patient selection, the 6.0mm Double Ends Cannulated Compression Screw can significantly improve patient outcomes and facilitate faster recovery. As the field of orthopedic implants continues to evolve, this screw is likely to remain a cornerstone in fracture management for years to come.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact