RSSWPB
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Pic | Screw | REF. | Spec. |
4.0mm Cancellous Screw Half-threaded | ![]() | / | RSSWPB4020 | 4.0*20mm |
RSSWPB4022 | 4.0*22mm | |||
RSSWPB4024 | 4.0*24mm | |||
RSSWPB4026 | 4.0*26mm | |||
RSSWPB4028 | 4.0*28mm | |||
RSSWPB4030 | 4.0*30mm | |||
RSSWPB4032 | 4.0*32mm | |||
RSSWPB4034 | 4.0*34mm | |||
RSSWPB4036 | 4.0*36mm | |||
RSSWPB4038 | 4.0*38mm | |||
RSSWPB4040 | 4.0*40mm | |||
RSSWPB4042 | 4.0*42mm | |||
RSSWPB4044 | 4.0*44mm | |||
RSSWPB4046 | 4.0*46mm | |||
RSSWPB4048 | 4.0*48mm | |||
RSSWPB4050 | 4.0*50mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 4.0mm Cancellous Screw Half-threaded Product Catalog.
2. Choose Your Interested 4.0mm Cancellous Screw Half-threaded Product.
3. Ask For A Sample To Test 4.0mm Cancellous Screw Half-threaded.
4.Make An Order Of XC Medico's 4.0mm Cancellous Screw Half-threaded.
5.Become A Dealer Of XC Medico's 4.0mm Cancellous Screw Half-threaded.
1.Better Purchase Prices Of 4.0mm Cancellous Screw Half-threaded.
2.100% The Highest Quality 4.0mm Cancellous Screw Half-threaded.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 4.0mm Cancellous Screw Half-threaded.
6. Quick And Easy Assessment Of XC Medico's 4.0mm Cancellous Screw Half-threaded.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 4.0mm Cancellous Screw Half-threaded is an essential orthopedic implant used for the stabilization and fixation of fractures in cancellous (spongy) bone. Designed to offer a secure hold in areas with softer, less dense bone, these screws play a critical role in promoting healing and maintaining fracture alignment. This guide provides an in-depth exploration of the 4.0mm Cancellous Screw Half-threaded, highlighting its features, advantages, applications in fracture treatment, and the risks associated with its use.
The 4.0mm Cancellous Screw Half-threaded is a specialized orthopedic screw used primarily in the treatment of fractures within cancellous bone. Cancellous bone, found at the ends of long bones such as the femur, tibia, and humerus, is less dense and more porous than cortical bone. As a result, screws designed for cancellous bone need to offer excellent grip and stability. The 4.0mm measurement refers to the diameter of the screw, making it suitable for medium-sized bone fractures.
The half-threaded design means that the screw features threads only on a portion of its shaft, typically along the distal part of the screw. This design allows for better purchase and fixation in the more cancellous bone while providing a smooth, unthreaded portion for the screw's head, ensuring a secure and stable insertion without damaging surrounding tissue. These screws are often made from titanium or stainless steel, both of which are known for their strength and biocompatibility, reducing the risk of complications such as infection or rejection.
The screw is partially threaded, with threads extending along the distal end of the shaft. This design is ideal for providing secure fixation in cancellous bone while minimizing trauma to surrounding tissues.
The self-tapping nature of the screw eliminates the need for pre-tapping the bone, reducing the surgical time and making the insertion process faster and less invasive.
The screw is typically made of high-quality titanium or stainless steel, which ensures that it will not react adversely with body tissues and minimizes the risk of inflammation or infection.
The screw is available in various lengths, allowing surgeons to select the most appropriate size for different fractures and anatomical regions.
The thread design is optimized for cancellous bone, with a larger thread pitch that provides better purchase in softer bone tissue, ensuring secure fixation.
The unthreaded portion of the screw shaft provides a smoother insertion, reducing the risk of damaging surrounding soft tissues and minimizing post-operative discomfort
The half-threaded design allows the screw to provide excellent compression across the fracture site, aiding in the alignment and stability of bone fragments during healing.
The screw's unique design maximizes its ability to securely fix fractures in cancellous bone, ensuring better fracture union and minimizing the risk of complications such as nonunion or malunion.
The self-tapping feature eliminates the need for pre-tapping, which helps speed up the surgical procedure, reducing overall operation time and minimizing patient exposure to anesthesia.
The smooth, unthreaded portion of the screw shaft protects the surrounding soft tissue, reducing the risk of damage during insertion and promoting faster recovery for the patient.
Suitable for a wide variety of fracture types in medium-sized bones such as the femur, tibia, humerus, and distal radius, the 4.0mm Cancellous Screw Half-threaded can be used in both trauma and elective orthopedic procedures.
By ensuring better fracture stability and compression, the screw contributes to faster and more predictable healing, reducing the likelihood of complications and the need for revision surgeries.
Used for femoral neck and intertrochanteric fractures, the 4.0mm Cancellous Screw Half-threaded provides excellent fixation in the soft cancellous bone of the femoral head, facilitating proper alignment and healing.
In fractures of the distal radius, the screw ensures strong fixation in the cancellous bone of the distal part of the forearm, preventing collapse and improving the alignment of fractured bone segments.
Osteoporotic bone is more fragile and prone to fractures. The 4.0mm Cancellous Screw Half-threaded offers reliable fixation and compression, essential for treating fractures in weakened bones, such as those in elderly patients.
The screw is used in the stabilization of tibial plateau fractures, where cancellous bone is present. Its unique design helps provide sufficient stability and compression to support healing.
The screw is also commonly used in the fixation of hand fractures, including metacarpal and phalangeal fractures, where the cancellous bone structure requires a reliable and stable implant.
In some cases, particularly in vertebral compression fractures, the 4.0mm Cancellous Screw Half-threaded can be used to stabilize fractured vertebrae, promoting alignment and enhancing healing outcomes.
Any surgical procedure carries a risk of infection, particularly around the screw site. Proper sterilization and post-operative care are crucial to minimizing this risk.
In patients with poor bone quality, such as those with osteoporosis, the screw may not achieve optimal fixation and may loosen over time, requiring revision surgery.
The screw's insertion near vital structures, such as nerves and blood vessels, can cause inadvertent injury, leading to postoperative complications like numbness or blood loss.
Inadequate compression or improper screw placement can lead to nonunion (failure to heal) or malunion (improper healing), which may necessitate further surgical intervention.
While rare, implants may fail due to material fatigue, improper insertion, or adverse reactions to the implant material, requiring revision surgery.
Some patients may experience pain around the surgical site, which may require pain management or further procedures for resolution.
As the global population ages, the incidence of osteoporotic fractures is increasing, which will drive demand for reliable implants like the 4.0mm Cancellous Screw Half-threaded.
With the rise of minimally invasive surgery and improvements in surgical tools, demand for screws that are easy to insert with minimal tissue damage is likely to increase.
The increasing availability of healthcare services in developing countries will contribute to a rise in the use of advanced orthopedic implants, including the 4.0mm Cancellous Screw Half-threaded.
Ongoing improvements in implant materials, design, and coating technologies will enhance the performance and longevity of the 4.0mm Cancellous Screw Half-threaded, further expanding its market.
The 4.0mm Cancellous Screw Half-threaded is a highly effective and versatile implant used in the fixation of fractures involving cancellous bone. Its unique design, featuring partial threading, ensures optimal compression and stability, aiding in the rapid healing of fractures. While there are risks involved in its use, including infection and screw loosening, these can be minimized with proper surgical technique and post-operative care. As the demand for orthopedic implants continues to rise, particularly in aging populations, the 4.0mm Cancellous Screw Half-threaded will remain a vital tool in orthopedic fracture management, contributing to better patient outcomes and faster recovery times.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Pic | Screw | REF. | Spec. |
4.0mm Cancellous Screw Half-threaded | ![]() | / | RSSWPB4020 | 4.0*20mm |
RSSWPB4022 | 4.0*22mm | |||
RSSWPB4024 | 4.0*24mm | |||
RSSWPB4026 | 4.0*26mm | |||
RSSWPB4028 | 4.0*28mm | |||
RSSWPB4030 | 4.0*30mm | |||
RSSWPB4032 | 4.0*32mm | |||
RSSWPB4034 | 4.0*34mm | |||
RSSWPB4036 | 4.0*36mm | |||
RSSWPB4038 | 4.0*38mm | |||
RSSWPB4040 | 4.0*40mm | |||
RSSWPB4042 | 4.0*42mm | |||
RSSWPB4044 | 4.0*44mm | |||
RSSWPB4046 | 4.0*46mm | |||
RSSWPB4048 | 4.0*48mm | |||
RSSWPB4050 | 4.0*50mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 4.0mm Cancellous Screw Half-threaded Product Catalog.
2. Choose Your Interested 4.0mm Cancellous Screw Half-threaded Product.
3. Ask For A Sample To Test 4.0mm Cancellous Screw Half-threaded.
4.Make An Order Of XC Medico's 4.0mm Cancellous Screw Half-threaded.
5.Become A Dealer Of XC Medico's 4.0mm Cancellous Screw Half-threaded.
1.Better Purchase Prices Of 4.0mm Cancellous Screw Half-threaded.
2.100% The Highest Quality 4.0mm Cancellous Screw Half-threaded.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 4.0mm Cancellous Screw Half-threaded.
6. Quick And Easy Assessment Of XC Medico's 4.0mm Cancellous Screw Half-threaded.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 4.0mm Cancellous Screw Half-threaded is an essential orthopedic implant used for the stabilization and fixation of fractures in cancellous (spongy) bone. Designed to offer a secure hold in areas with softer, less dense bone, these screws play a critical role in promoting healing and maintaining fracture alignment. This guide provides an in-depth exploration of the 4.0mm Cancellous Screw Half-threaded, highlighting its features, advantages, applications in fracture treatment, and the risks associated with its use.
The 4.0mm Cancellous Screw Half-threaded is a specialized orthopedic screw used primarily in the treatment of fractures within cancellous bone. Cancellous bone, found at the ends of long bones such as the femur, tibia, and humerus, is less dense and more porous than cortical bone. As a result, screws designed for cancellous bone need to offer excellent grip and stability. The 4.0mm measurement refers to the diameter of the screw, making it suitable for medium-sized bone fractures.
The half-threaded design means that the screw features threads only on a portion of its shaft, typically along the distal part of the screw. This design allows for better purchase and fixation in the more cancellous bone while providing a smooth, unthreaded portion for the screw's head, ensuring a secure and stable insertion without damaging surrounding tissue. These screws are often made from titanium or stainless steel, both of which are known for their strength and biocompatibility, reducing the risk of complications such as infection or rejection.
The screw is partially threaded, with threads extending along the distal end of the shaft. This design is ideal for providing secure fixation in cancellous bone while minimizing trauma to surrounding tissues.
The self-tapping nature of the screw eliminates the need for pre-tapping the bone, reducing the surgical time and making the insertion process faster and less invasive.
The screw is typically made of high-quality titanium or stainless steel, which ensures that it will not react adversely with body tissues and minimizes the risk of inflammation or infection.
The screw is available in various lengths, allowing surgeons to select the most appropriate size for different fractures and anatomical regions.
The thread design is optimized for cancellous bone, with a larger thread pitch that provides better purchase in softer bone tissue, ensuring secure fixation.
The unthreaded portion of the screw shaft provides a smoother insertion, reducing the risk of damaging surrounding soft tissues and minimizing post-operative discomfort
The half-threaded design allows the screw to provide excellent compression across the fracture site, aiding in the alignment and stability of bone fragments during healing.
The screw's unique design maximizes its ability to securely fix fractures in cancellous bone, ensuring better fracture union and minimizing the risk of complications such as nonunion or malunion.
The self-tapping feature eliminates the need for pre-tapping, which helps speed up the surgical procedure, reducing overall operation time and minimizing patient exposure to anesthesia.
The smooth, unthreaded portion of the screw shaft protects the surrounding soft tissue, reducing the risk of damage during insertion and promoting faster recovery for the patient.
Suitable for a wide variety of fracture types in medium-sized bones such as the femur, tibia, humerus, and distal radius, the 4.0mm Cancellous Screw Half-threaded can be used in both trauma and elective orthopedic procedures.
By ensuring better fracture stability and compression, the screw contributes to faster and more predictable healing, reducing the likelihood of complications and the need for revision surgeries.
Used for femoral neck and intertrochanteric fractures, the 4.0mm Cancellous Screw Half-threaded provides excellent fixation in the soft cancellous bone of the femoral head, facilitating proper alignment and healing.
In fractures of the distal radius, the screw ensures strong fixation in the cancellous bone of the distal part of the forearm, preventing collapse and improving the alignment of fractured bone segments.
Osteoporotic bone is more fragile and prone to fractures. The 4.0mm Cancellous Screw Half-threaded offers reliable fixation and compression, essential for treating fractures in weakened bones, such as those in elderly patients.
The screw is used in the stabilization of tibial plateau fractures, where cancellous bone is present. Its unique design helps provide sufficient stability and compression to support healing.
The screw is also commonly used in the fixation of hand fractures, including metacarpal and phalangeal fractures, where the cancellous bone structure requires a reliable and stable implant.
In some cases, particularly in vertebral compression fractures, the 4.0mm Cancellous Screw Half-threaded can be used to stabilize fractured vertebrae, promoting alignment and enhancing healing outcomes.
Any surgical procedure carries a risk of infection, particularly around the screw site. Proper sterilization and post-operative care are crucial to minimizing this risk.
In patients with poor bone quality, such as those with osteoporosis, the screw may not achieve optimal fixation and may loosen over time, requiring revision surgery.
The screw's insertion near vital structures, such as nerves and blood vessels, can cause inadvertent injury, leading to postoperative complications like numbness or blood loss.
Inadequate compression or improper screw placement can lead to nonunion (failure to heal) or malunion (improper healing), which may necessitate further surgical intervention.
While rare, implants may fail due to material fatigue, improper insertion, or adverse reactions to the implant material, requiring revision surgery.
Some patients may experience pain around the surgical site, which may require pain management or further procedures for resolution.
As the global population ages, the incidence of osteoporotic fractures is increasing, which will drive demand for reliable implants like the 4.0mm Cancellous Screw Half-threaded.
With the rise of minimally invasive surgery and improvements in surgical tools, demand for screws that are easy to insert with minimal tissue damage is likely to increase.
The increasing availability of healthcare services in developing countries will contribute to a rise in the use of advanced orthopedic implants, including the 4.0mm Cancellous Screw Half-threaded.
Ongoing improvements in implant materials, design, and coating technologies will enhance the performance and longevity of the 4.0mm Cancellous Screw Half-threaded, further expanding its market.
The 4.0mm Cancellous Screw Half-threaded is a highly effective and versatile implant used in the fixation of fractures involving cancellous bone. Its unique design, featuring partial threading, ensures optimal compression and stability, aiding in the rapid healing of fractures. While there are risks involved in its use, including infection and screw loosening, these can be minimized with proper surgical technique and post-operative care. As the demand for orthopedic implants continues to rise, particularly in aging populations, the 4.0mm Cancellous Screw Half-threaded will remain a vital tool in orthopedic fracture management, contributing to better patient outcomes and faster recovery times.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact