RSSWP
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Pic | Screw | REF. | Spec. |
6.5mm Cancellous Screw Full-threaded | / | RSSWP6540 | 6.5*40mm | |
RSSWP6545 | 6.5*45mm | |||
RSSWP6550 | 6.5*50mm | |||
RSSWP6555 | 6.5*55mm | |||
RSSWP6560 | 6.5*60mm | |||
RSSWP6565 | 6.5*65mm | |||
RSSWP6570 | 6.5*70mm | |||
RSSWP6575 | 6.5*75mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 6.5mm Cancellous Screw Full-threaded Product Catalog.
2. Choose Your Interested 6.5mm Cancellous Screw Full-threaded Product.
3. Ask For A Sample To Test 6.5mm Cancellous Screw Full-threaded.
4.Make An Order Of XC Medico's 6.5mm Cancellous Screw Full-threaded.
5.Become A Dealer Of XC Medico's 6.5mm Cancellous Screw Full-threaded.
1.Better Purchase Prices Of 6.5mm Cancellous Screw Full-threaded.
2.100% The Highest Quality 6.5mm Cancellous Screw Full-threaded.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 6.5mm Cancellous Screw Full-threaded.
6. Quick And Easy Assessment Of XC Medico's 6.5mm Cancellous Screw Full-threaded.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 6.5mm Cancellous Screw Full-threaded is a crucial orthopedic implant used in the stabilization of fractures in cancellous (spongy) bone. This screw is designed with a full-threaded shaft to provide enhanced fixation and compression at fracture sites. Cancellous bone, being less dense than cortical bone, requires implants that offer a secure hold and promote rapid healing. The 6.5mm size is particularly effective for fractures in larger bones or those with compromised bone quality, such as osteoporotic bones. This guide provides an in-depth look into the features, advantages, surgical applications, risks, and the future of the 6.5mm Cancellous Screw Full-threaded.
The 6.5mm Cancellous Screw Full-threaded is a specialized orthopedic screw designed for use in cancellous bone. Cancellous bone is the porous, spongy bone found at the ends of long bones, such as the femur, tibia, and humerus, as well as in vertebrae. These screws are engineered to have a larger thread pitch to accommodate the softer, less dense structure of cancellous bone.
The 6.5mm size denotes the diameter of the screw, making it ideal for fractures in larger bones or areas with dense cancellous bone. The full-threaded design ensures maximum surface contact between the screw and bone, allowing for better compression and stability. The screw is typically made of materials such as titanium or stainless steel, which offer excellent biocompatibility, strength, and resistance to corrosion.
The screw's full-threaded design increases its surface contact with the cancellous bone, ensuring optimal fixation and better compression at the fracture site.
The self-tapping feature allows the screw to be inserted without the need for pre-tapping, reducing the time required for surgery and minimizing trauma to surrounding tissues.
Made from materials like titanium or stainless steel, the screw is highly biocompatible, reducing the risk of rejection or complications from foreign body reactions.
The screw has a larger thread pitch to accommodate the softer structure of cancellous bone. This allows for a secure grip, preventing loosening or migration.
The screw is available in a range of lengths to suit different fracture sites and patient anatomy, allowing surgeons to select the most appropriate size for each case.
The design of the screw ensures easy and smooth insertion, reducing the risk of complications during the procedure.
The full-threaded design enhances the screw’s ability to provide a strong hold in cancellous bone, preventing displacement or migration of the implant. This is crucial for promoting successful healing in fractures.
The screw creates a compressive force across the fracture site, which aids in reducing motion at the fracture ends and accelerates the healing process.
The 6.5mm Cancellous Screw Full-threaded is suitable for a wide range of fracture types and locations, including fractures in the femur, tibia, humerus, and vertebrae.
Due to the self-tapping feature, the screw eliminates the need for pre-tapping, speeding up the procedure and reducing surgical time, which is particularly beneficial in emergency cases or minimally invasive surgery.
The screw's design and the larger thread pitch help prevent screw loosening, which is especially important in patients with osteoporotic bone or compromised bone quality.
The strong fixation and effective compression provided by the screw lead to enhanced healing outcomes, reducing the risk of complications such as nonunion or malunion.
These screws are often used in hip fractures, including femoral neck fractures and intertrochanteric fractures. The screw provides reliable fixation in the cancellous bone of the femoral head, promoting faster healing and reducing the risk of complications.
In fractures of the distal radius, particularly those involving osteoporotic bone, the 6.5mm Cancellous Screw Full-threaded helps stabilize the fracture and ensures strong compression at the fracture site.
Patients with osteoporosis are at higher risk of fractures due to weakened bone structure. The 6.5mm Cancellous Screw Full-threaded is ideal for stabilizing these fractures, as its design accommodates the softer, less dense bone.
The screw is commonly used to treat fractures of the proximal humerus, where the cancellous bone is prevalent. The screw's ability to provide compression and stability is critical for promoting proper healing in these types of fractures.
In spinal fractures, especially those involving the vertebrae, the 6.5mm Cancellous Screw Full-threaded is used to stabilize the vertebral body and restore spinal alignment.
The screw is also used in the treatment of fractures of the tibial plateau, providing strong fixation and preventing the risk of collapse or malalignment during the healing process.
As with any implant, there is a risk of infection at the surgical site or around the implant. Proper sterilization techniques and post-operative care are essential to minimize this risk.
In patients with poor bone quality, particularly those with osteoporosis, there is a risk of the screw loosening over time, leading to loss of fracture fixation.
Improper placement of the screw or surgical complications can lead to injury to nearby nerves or blood vessels, resulting in postoperative complications.
If the screw fails to provide sufficient compression or if the fracture is not properly aligned, nonunion or malunion may occur, requiring additional surgery.
Rarely, screws can fail due to material fatigue, improper insertion, or bone complications, necessitating revision surgery.
Some patients may experience pain or discomfort around the surgical site, which can be managed with medication or further intervention if necessary.
As the global population ages, the incidence of fractures, especially osteoporotic fractures, is expected to rise, driving demand for strong and reliable fracture fixation implants.
Technological innovations, such as the development of bioactive coatings and improved screw designs, will likely increase the popularity of the 6.5mm Cancellous Screw Full-threaded.
The growing trend towards minimally invasive surgery will boost the demand for screws that can be inserted through smaller incisions, reducing recovery time and patient discomfort.
As healthcare infrastructure improves in emerging markets, access to advanced orthopedic implants, such as the 6.5mm Cancellous Screw Full-threaded, will expand.
The 6.5mm Cancellous Screw Full-threaded is a versatile and effective orthopedic implant designed for use in cancellous bone fractures. With its full-threaded design, self-tapping mechanism, and biocompatible materials, it provides superior fixation and compression, ensuring optimal healing outcomes for patients. While there are risks associated with its use, including infection and screw loosening, proper surgical technique and post-operative care can minimize these complications. As demand for orthopedic implants grows, particularly in aging populations, the 6.5mm Cancellous Screw Full-threaded will continue to play a crucial role in fracture management and rehabilitation.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Pic | Screw | REF. | Spec. |
6.5mm Cancellous Screw Full-threaded | / | RSSWP6540 | 6.5*40mm | |
RSSWP6545 | 6.5*45mm | |||
RSSWP6550 | 6.5*50mm | |||
RSSWP6555 | 6.5*55mm | |||
RSSWP6560 | 6.5*60mm | |||
RSSWP6565 | 6.5*65mm | |||
RSSWP6570 | 6.5*70mm | |||
RSSWP6575 | 6.5*75mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 6.5mm Cancellous Screw Full-threaded Product Catalog.
2. Choose Your Interested 6.5mm Cancellous Screw Full-threaded Product.
3. Ask For A Sample To Test 6.5mm Cancellous Screw Full-threaded.
4.Make An Order Of XC Medico's 6.5mm Cancellous Screw Full-threaded.
5.Become A Dealer Of XC Medico's 6.5mm Cancellous Screw Full-threaded.
1.Better Purchase Prices Of 6.5mm Cancellous Screw Full-threaded.
2.100% The Highest Quality 6.5mm Cancellous Screw Full-threaded.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 6.5mm Cancellous Screw Full-threaded.
6. Quick And Easy Assessment Of XC Medico's 6.5mm Cancellous Screw Full-threaded.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 6.5mm Cancellous Screw Full-threaded is a crucial orthopedic implant used in the stabilization of fractures in cancellous (spongy) bone. This screw is designed with a full-threaded shaft to provide enhanced fixation and compression at fracture sites. Cancellous bone, being less dense than cortical bone, requires implants that offer a secure hold and promote rapid healing. The 6.5mm size is particularly effective for fractures in larger bones or those with compromised bone quality, such as osteoporotic bones. This guide provides an in-depth look into the features, advantages, surgical applications, risks, and the future of the 6.5mm Cancellous Screw Full-threaded.
The 6.5mm Cancellous Screw Full-threaded is a specialized orthopedic screw designed for use in cancellous bone. Cancellous bone is the porous, spongy bone found at the ends of long bones, such as the femur, tibia, and humerus, as well as in vertebrae. These screws are engineered to have a larger thread pitch to accommodate the softer, less dense structure of cancellous bone.
The 6.5mm size denotes the diameter of the screw, making it ideal for fractures in larger bones or areas with dense cancellous bone. The full-threaded design ensures maximum surface contact between the screw and bone, allowing for better compression and stability. The screw is typically made of materials such as titanium or stainless steel, which offer excellent biocompatibility, strength, and resistance to corrosion.
The screw's full-threaded design increases its surface contact with the cancellous bone, ensuring optimal fixation and better compression at the fracture site.
The self-tapping feature allows the screw to be inserted without the need for pre-tapping, reducing the time required for surgery and minimizing trauma to surrounding tissues.
Made from materials like titanium or stainless steel, the screw is highly biocompatible, reducing the risk of rejection or complications from foreign body reactions.
The screw has a larger thread pitch to accommodate the softer structure of cancellous bone. This allows for a secure grip, preventing loosening or migration.
The screw is available in a range of lengths to suit different fracture sites and patient anatomy, allowing surgeons to select the most appropriate size for each case.
The design of the screw ensures easy and smooth insertion, reducing the risk of complications during the procedure.
The full-threaded design enhances the screw’s ability to provide a strong hold in cancellous bone, preventing displacement or migration of the implant. This is crucial for promoting successful healing in fractures.
The screw creates a compressive force across the fracture site, which aids in reducing motion at the fracture ends and accelerates the healing process.
The 6.5mm Cancellous Screw Full-threaded is suitable for a wide range of fracture types and locations, including fractures in the femur, tibia, humerus, and vertebrae.
Due to the self-tapping feature, the screw eliminates the need for pre-tapping, speeding up the procedure and reducing surgical time, which is particularly beneficial in emergency cases or minimally invasive surgery.
The screw's design and the larger thread pitch help prevent screw loosening, which is especially important in patients with osteoporotic bone or compromised bone quality.
The strong fixation and effective compression provided by the screw lead to enhanced healing outcomes, reducing the risk of complications such as nonunion or malunion.
These screws are often used in hip fractures, including femoral neck fractures and intertrochanteric fractures. The screw provides reliable fixation in the cancellous bone of the femoral head, promoting faster healing and reducing the risk of complications.
In fractures of the distal radius, particularly those involving osteoporotic bone, the 6.5mm Cancellous Screw Full-threaded helps stabilize the fracture and ensures strong compression at the fracture site.
Patients with osteoporosis are at higher risk of fractures due to weakened bone structure. The 6.5mm Cancellous Screw Full-threaded is ideal for stabilizing these fractures, as its design accommodates the softer, less dense bone.
The screw is commonly used to treat fractures of the proximal humerus, where the cancellous bone is prevalent. The screw's ability to provide compression and stability is critical for promoting proper healing in these types of fractures.
In spinal fractures, especially those involving the vertebrae, the 6.5mm Cancellous Screw Full-threaded is used to stabilize the vertebral body and restore spinal alignment.
The screw is also used in the treatment of fractures of the tibial plateau, providing strong fixation and preventing the risk of collapse or malalignment during the healing process.
As with any implant, there is a risk of infection at the surgical site or around the implant. Proper sterilization techniques and post-operative care are essential to minimize this risk.
In patients with poor bone quality, particularly those with osteoporosis, there is a risk of the screw loosening over time, leading to loss of fracture fixation.
Improper placement of the screw or surgical complications can lead to injury to nearby nerves or blood vessels, resulting in postoperative complications.
If the screw fails to provide sufficient compression or if the fracture is not properly aligned, nonunion or malunion may occur, requiring additional surgery.
Rarely, screws can fail due to material fatigue, improper insertion, or bone complications, necessitating revision surgery.
Some patients may experience pain or discomfort around the surgical site, which can be managed with medication or further intervention if necessary.
As the global population ages, the incidence of fractures, especially osteoporotic fractures, is expected to rise, driving demand for strong and reliable fracture fixation implants.
Technological innovations, such as the development of bioactive coatings and improved screw designs, will likely increase the popularity of the 6.5mm Cancellous Screw Full-threaded.
The growing trend towards minimally invasive surgery will boost the demand for screws that can be inserted through smaller incisions, reducing recovery time and patient discomfort.
As healthcare infrastructure improves in emerging markets, access to advanced orthopedic implants, such as the 6.5mm Cancellous Screw Full-threaded, will expand.
The 6.5mm Cancellous Screw Full-threaded is a versatile and effective orthopedic implant designed for use in cancellous bone fractures. With its full-threaded design, self-tapping mechanism, and biocompatible materials, it provides superior fixation and compression, ensuring optimal healing outcomes for patients. While there are risks associated with its use, including infection and screw loosening, proper surgical technique and post-operative care can minimize these complications. As demand for orthopedic implants grows, particularly in aging populations, the 6.5mm Cancellous Screw Full-threaded will continue to play a crucial role in fracture management and rehabilitation.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact